20 MHz-3 GHz Programmable Chirp Spread Spectrum Generator for a Wideband Radio Jamming Application

  • Kim, Sun-Ryoul;Ryu, Hyuk;Ha, Keum-Won;Kim, Jeong-Geun;Baek, Donghyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.771-776
    • /
    • 2014
  • In this paper, an agile programmable chirp spread spectrum generator for wideband frequency-jamming applications from 20 MHz to 3 GHz is proposed. A frequency-mixing architecture using two voltage-controlled oscillators is used to achieve a wideband operating frequency range, and the direct digital synthesizer (DDS)-based chirping method with a two-point modulation technique is employed to provide a programmable and consistent chirp bandwidth. The proposed signal generator provides the various programmable FM signals from 20 MHz to 3 GHz with a modulation bandwidth from 0 to 400 MHz. The prototype successfully demonstrates arbitrary sequential jamming operation with a fast band-to-band hopping time of < 10 ${\mu}sec$.

Generating Characteristics of a Cantilever Type Piezoelectric Generator for Changeable Frequency (주파수 가변용 외팔보형 압전발전기의 발전특성)

  • Jeong, Seong-Su;Park, Choong-Hyo;Kang, Shin-Chul;Kim, Jong-Wook;Lim, Jung-Hoon;Kim, Myong-Ho;Park, Tae-Gone
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.11
    • /
    • pp.865-869
    • /
    • 2011
  • A cantilever-type piezoelectric generator has advantages of simple structure, ease of fabrication and large displacement by transverse vibration of a beam. It is easy to control the natural frequency, and also possible to increase the output power by changing the length, width, and thickness of the generator. In particular, the length increases, the natural frequency sharply decreases, and vice versa. Hence, the natural frequency can widely be controlled by using change in the length of elastic body. In this paper, the generator was designed and fabricated to change natural frequency using the slides of the case. In addition, the generating characteristics were confirmed through finite element analyses and vibration experiment. As a result, the maximum output characteristics could be generated due to resonance phenomenon although any frequency of external force was applied.

Permanent magnet excitation generator Voltage fluctuation suppression control method (영구자석 여자기형 발전기의 전압변동 억제 제어방식)

  • Jo, YeongJun;Kwak, YunChang;Lee, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.74-75
    • /
    • 2017
  • This paper proposes a control scheme of the voltage ripple suppression for the permanent magnet exciter generator. The output voltage of the permanent magnet excitation generator is affected by the field current, load current and the engine speed. The engine speed can be controlled by the governor. But, the actual frequency is changed at the starting and a sudden load variation. As a result, output voltage overshoot and undershoot can decrease the power quality in the grid system. The proposed control scheme uses a frequency factor to control the field current of the generator for the voltage ripple reduction. Because of the linkage flux is proportional to the frequency, the instantaneous frequency can consider the linkage flux. The proposed control method shows the improved control performance for the permanent magnet excitation generator through simulation.

  • PDF

Wide-area Frequency-based Tripped Generator Locating Method for Interconnected Power Systems

  • Kook, Kyung-Soo;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.776-785
    • /
    • 2011
  • Since the Internet-based real-time Global Positioning System(GPS) synchronized widearea power system frequency monitoring network (FNET) was proposed in 2001, it has been monitoring the power system frequency in interconnected United States power systems and numerous interesting behaviors have been observed, including frequency excursion propagation. We address the consistency of a frequency excursion detection order of frequency disturbance recorders in FNET in relation to the same generation trip, as well as the ability to recreate by power systems dynamic simulation. We also propose a new method, as an application of FNET measurement, to locate a tripped generator using power systems dynamic simulation and wide-area frequency measurement. The simulation database of all the possible trips of generators in the interconnected power systems is created using the off-line power systems dynamic simulation. When FNET detects a sudden drop in the monitoring frequency, which is most likely due to a generation trip in power systems, the proposed algorithm locates a tripped generator by finding the best matching case of the measured frequency excursion in the simulation database in terms of the frequency drop detection order and the time of monitoring points.

Design and fabrication of driving generator for ultrasonic motors (초음파 모터 구동용 발진회로의 설계 및 제작)

  • 심성훈;백동수;윤석진;김현재
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.129-131
    • /
    • 1999
  • Driving generator of USMs(ultrasonic motors) with low noise, high efficiency was designed and fabricated. It was focused on merits such as size-reduction, thermal resistance, To control revolution speed, input frequency was varied. Output of generator had frequency range of 39.1 ∼ 43.5 MHz and voltage of 120 V. USM with resonant frequency 40.3 kHz exhibited a maximum torque of 2.5 kg $.$ cm and a maximum revolution speed of about 130 rpm.

  • PDF

Dynamic Study of Co-generator System Using EMTDC (EMTDC를 이용한 자가용 계통 해석)

  • Kim, H.M.;Kim, D.H.;Chun, Y.H.;Kim, J.W.;Jeon, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.295-297
    • /
    • 2001
  • This paper deals with dynamic study of co-generator system with derived dynamic models of generator, excitation system, and turbine/governor from field tests. Mainly this study concentrates on frequency control of demand users that have co-generator by under-frequency relay. We simulates dynamic study of co-generator system using EMTDC.

  • PDF

Microcomputer-Based Constant Frequency Control of Generating System Driven by Hydraulic Power -Pump Displacement Control Type - (마이크로컴퓨터에 의한 유압구동식 발전장치의 정주파수 제어)

  • 정용길;이일영;김상봉;양주호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.53-63
    • /
    • 1991
  • This study suggests a new type shaft generator driven by hydraulic power suitable for small size vessels. Since the shaft generator system is very easy to be affected by disturbances such as speed variation of main engine and load variation of the generator, a robust servo control must be implemented to obtain stable electric power with constant frequency. Thus, in this study two types of controller design method-the reference following optimal control method and robust servo control method-are adopted to the controller design. In the experiment, static and dynamic characteristics of the shaft generator system according to the variation of input frequency setting, the speed variation of the pump and the load variation of the generator are investigated. From the considerations on the computer simulation results and experimental results, it is ascertained that the shaft generator system proposed in this study has good control performances.

  • PDF

Experimental Study on Frequency Support of Variable Speed Wind Turbine Based on Electromagnetic Coupler

  • You, Rui;Chai, Jianyun;Sun, Xudong;Bi, Daqiang;Wu, Xinzhen
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.195-203
    • /
    • 2018
  • In the variable speed Wind Turbine based on ElectroMagnetic Coupler (WT-EMC), a synchronous generator is coupled directly to the grid. Therefore, like conventional power plants, WT-EMC is able to inherently support grid frequency. However, due to the reduced inertia of the synchronous generator, WT-EMC is expected to be controlled to increase its output power in response to a grid frequency drop to support grid frequency. Similar to the grid frequency support control of Type 3 or Type 4 wind turbine, inertial control and droop control can be used to calculate the WT-EMC additional output power reference according to the synchronous generator speed. In this paper, an experimental platform is built to study the grid frequency support from WT-EMC with inertial control and droop control. Two synchronous generators, driven by two induction motors controlled by two converters, are used to emulate the synchronous generators in conventional power plants and in WT-EMCs respectively. The effectiveness of the grid frequency support from WT-EMC with inertial control and droop control responding to a grid frequency drop is validated by experimental results. The selection of the grid frequency support controller and its gain for WT-EMC is analyzed briefly.

An Analysis of Power System Stability(PSS) Effect with 135MVA Hydro Generator (135MVA 수력 발전기의 전력 시스템 안정화 장치 적용 효과 분석)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Byun, Ill-Hwan;Oh, Sueg-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1100-1104
    • /
    • 2009
  • As national power consumption every year increases, the power plant which is in the process of planning tries to establish high-capacity generator. The power system tends to become a large size. With the progress of electronic components, the control systems of the generator have been digitalized and rapid-response control system is possible. However, the minute frequency vibration of grid occurred with the effect of rapid-response control system. To solve these problem, PPS(Power System Stability) has been introduced since 2004, and it has being installed and applied to the thermal and nuclear power plant which are high-capacity, over 800MVA. However the minute frequency vibration is gradually changed to the bigger frequency vibration by fast-action control system, and this regional frequency fluctuation might be diffused wide area. Therefore, it is applied to the hydro generator which is small with fast-action governor system, and it is necessary to control the minute frequency vibration to prevent to diffuse. In this paper, the effect will be proved by establishing PSS on the Hydro-Generator which has both digital excitation and governor system for the first time in Korea.

The Characteristics of Fluid Flow in a Channel by Oscillating Vortex Generator (가진되는 와류발생기에 의한 채널내의 유동 특성)

  • Bang, Chang-Hoon;Kim, Jung-Soo;Choo, Hong-Lok
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.2 s.80
    • /
    • pp.1-7
    • /
    • 2007
  • A problem of a unsteady time-dependent flow in a channel is of practical importance and widely considered in the design of devices such as heat exchangers, duct, and electronic equipments. The characteristics of fluid flow in channel with oscillating vortex generator was investigated experimentally. The main object of this study was to investigate the effect of the excited frequency, the excited amplitude, and Reynolds numbers on the generated frequency. Flow patterns were visualized using smoke generator and generated frequencies were measured using hot wire anemometer. When the excited frequency is increased, excited amplitude decreased and Reynolds number increased, the strength of PSD of generated frequency is decreased.