• 제목/요약/키워드: Frequency Generation

검색결과 2,074건 처리시간 0.032초

회전자 속도에 따라 변동하는 풍력발전단지 주파수 편차 루프 제어 연구 (Control of the Wind Power Plant Frequency Variance Loop with Respect to Rotor Speed)

  • 이창민;최현준;박지훈;김성환
    • 신재생에너지
    • /
    • 제20권2호
    • /
    • pp.55-64
    • /
    • 2024
  • To ensure the frequency stability of wind power generation, we analyzedd the existing technology and proposedd a method for changing the gain value with respect to to the rotor speed by adding the MPPT reference value and output reference value that reflect the system frequency. The MPPT control and output were compared and calculated for performance verification. Subsequently, the application of the proposed algorithm led to an increased output when compared with that of the existing control method.

전압 및 주파수 변화에 따른 저압 콘덴서 열 분포 해석 (Analysis for Thermal Distribution of Low-voltage Condenser by the Variance of Voltage & Frequency)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제24권4호
    • /
    • pp.43-49
    • /
    • 2010
  • 콘덴서는 유도성 부하의 늦은 역률 보상으로도 사용되며, 비선형 부하에서 발생하는 고조파를 저감하기 위해 리액터에 직렬로 연결하여 사용되기도 한다. 전압, 전류의 증가와 열의 발생은 콘덴서 수명에 많은 영향을 준다. 전압이 증가할 경우 전류가 증가하고, 주파수의 증가도 전류의 증가로 이어지기 때문에 전압과 주파수의 증가는 바로 열의 증가로 콘덴서 절연에 스트레스로 작용하여 고장의 원인을 제공할 수 있다. 본 연구에서는 전압의 크기와 주파수를 변화시킬 경우 콘덴서에서 발생하는 열의 분포도를 열화상 카메라로 측정하였다. 측정결과 전압과 주파수의 증가는 높은 열을 발생시켜 콘덴서의 수명을 단축시키는 요소로 작용함을 확인할 수 있었다.

A Medium-Voltage Matrix Converter Topology for Wind Power Conversion with Medium Frequency Transformers

  • Gu, Chunyang;Krishnamoorthy, Harish S.;Enjeti, Prasad N.;Zheng, Zedong;Li, Yongdong
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1166-1177
    • /
    • 2014
  • A new type of topology with medium-frequency-transformer (MFT) isolation for medium voltage wind power generation systems is proposed in this paper. This type of converter is a high density power conversion system, with high performance features suitable for next generation wind power systems in either on-shore or off-shore applications. The proposed topology employs single-phase cascaded multi-level AC-AC converters on the grid side and three phase matrix converters on the generator side, which are interfaced by medium frequency transformers. This avoids DC-Link electrolytic capacitors and/or resonant L-C components in the power flow path thereby improving the power density and system reliability. Several configurations are given to fit different applications. The modulation and control strategy has been detailed. As two important part of the whole system, a novel single phase AC-AC converter topology with its reliable six-step switching technique and a novel symmetrical 11-segment modulation strategy for two stage matrix converter (TSMC) is proposed at the special situation of medium frequency chopping. The validity of the proposed concept has been verified by simulation results and experiment waveforms from a scaled down laboratory prototype.

A D-Band Integrated Signal Source Based on SiGe 0.18μm BiCMOS Technology

  • Jung, Seungyoon;Yun, Jongwon;Rieh, Jae-Sung
    • Journal of electromagnetic engineering and science
    • /
    • 제15권4호
    • /
    • pp.232-238
    • /
    • 2015
  • This work describes the development of a D-band (110-170 GHz) signal source based on a SiGe BiCMOS technology. This D-band signal source consists of a V-band (50-75 GHz) oscillator, a V-band amplifier, and a D-band frequency doubler. The V-band signal from the oscillator is amplified for power boost, and then the frequency is doubled for D-band signal generation. The V-band oscillator showed an output power of 2.7 dBm at 67.3 GHz. Including a buffer stage, it had a DC power consumption of 145 mW. The peak gain of the V-band amplifier was 10.9 dB, which was achieved at 64.0 GHz and consumed 110 mW of DC power. The active frequency doubler consumed 60 mW for D-band signal generation. The integrated D-band source exhibited a measured output oscillation frequency of 133.2 GHz with an output power of 3.1 dBm and a phase noise of -107.2 dBc/Hz at 10 MHz offset. The chip size is $900{\times}1,890{\mu}m^2$, including RF and DC pads.

독립형 마이크로그리드내 풍력발전출력이 주파수 품질에 미치는 영향 분석 (Study on Impact of Wind Power in Grid Frequency Quality of Stand-alone Microgrid)

  • 허재선;김재철
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.79-85
    • /
    • 2016
  • This paper analyzed the influence of wind power fluctuations in grid frequency of a stand-alone microgrid that is hybrid generation system with diesel generator, wind turbine, and Battery Energy Storage System (BESS). The existing island area power system consists of only diesel generators. So the grid frequency can be controllable from load change. But hybrid generation system with Renewable Energy Sources (RES) such as wind energy that has the intermittent output can bring power quality problems. BESS is one of the ways to improve the intermittent output of the RES. In this paper, we analyzed the role of BESS in a stand-alone microgrid. We designed a modelling of wind power system with squirrel-cage induction generator, diesel power system with synchronous generator, and BESS using transient analysis program PSCAD/EMTDC. And we analyzed the variation of the grid frequency according to the output of BESS.

Sinusoidal, Pulse, Triangular Oscillator Using Second Generation Current Conveyor

  • Choi, Jin-Ho
    • Journal of information and communication convergence engineering
    • /
    • 제8권5호
    • /
    • pp.566-569
    • /
    • 2010
  • This paper describes the sinusoidal, pulse, triangular oscillator using second generation current conveyor. To obtain the sinusoidal waveform the circuit blocks are constructed by using all pass filter and integrator. The pulse and the triangular waveforms are obtained from the output of sinusoidal oscillator. The peak-to-peak voltages of sinusoidal and triangular waveforms can be easily controlled by the dc offset voltage. Also the output frequency of the oscillator can be controlled by varying passive elements. The designed circuit is verified by HSPICE simulation.

PWM 쵸퍼와 전류형 인버터를 이용한 계통연계형 태양광발전시스템 (A Utility Interactive Photovoltaic Generation System using PWM Chopper and Current Source Inverter)

  • 이승환;성낙규;오봉환;검성남;이훈구;김용주;한경희
    • 전력전자학회논문지
    • /
    • 제3권4호
    • /
    • pp.323-329
    • /
    • 1998
  • 계통연계형 태양광발전시스템을 PWM 쵸퍼와 전류형 인버터로 구성하였다. 전류형 인버터의 직류리액터를 경감하는 방법으로, 직류측에 병렬공진회로를 삽입함에 따라 맥동전력의 일부를 교류 전해콘덴서에 축적하여 직류전류의 맥동을 억제하는 방법과, 쵸퍼의 변조파를 전원주파수의 2배로 제어하여 직류전류의 맥동을 억제하는 것을 비교 검토하였다. 그리고 태양전지전류와 쵸퍼의 변조율만을 이용하여 태양전지가 항상 최대출력점에서 동작하도록 하였다. 계통과 연계함으로서 출력전력이 부하전력보다 큰 경우에는 잉영전력을 계통전원에 공급하고, 발전전력 부하전력에 대해 부족한 경우에는 계통전원이 부족분을 공급하는 것을 확인하였다.

  • PDF

영구자석형 풍력-디젤-BESS 복합발전시스템 모델링 및 운전제어 알고리즘에 관한 연구 (Modeling & Operating Algorithm of Hybrid Generation System with PMSG Wind Turbine, Diesel Generator and BESS)

  • 오준석;정의용;박종호;박민수;김재언
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.724-729
    • /
    • 2016
  • Nowadays high-cost energy storage system using flywheel or secondary battery is applying to hybrid generation system with WT(Wind Turbine) and diesel generator in island areas for stable operation. This paper proposes an operating algorithm and modeling method of the hybrid generation system that can operate for variable wind speed and load, which is composed of energy storage system, variable-speed PMSG(Permanent Magnet Synchronous Generator) WT and diesel generator applied in island areas. Initially, the operating algorithm was proposed for frequency and voltage to be maintained within the proper ranges for load and wind speed changes. Also, the modeling method is proposed for variable speed PMSG WT, diesel generator and BESS(Battery Energy Storage System). The proposed operating algorithm and modeling method were applied to a typical island area. The frequency and voltage was kept within the permissible ranges and the proposed method was proven to be appropriate through simulations.

고체로켓 내부에서의 Roll 발생 현상 3D LES (Large Eddy Simulation for the investigation of Roll Development Process in a Solid Rocket Motor)

  • 김종찬;홍지석;염효원;문희장;김진곤;성홍계
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.253-257
    • /
    • 2011
  • 고체로켓에서 발생하는 vortex shedding 현상 중 인히비터로 인해 발생하는 연소실내 와류(vortex)의 특성을 조사하기 위해 Large Eddy Simulation을 수행하였다. 해석의 결과는 기존 연구자들의 결과와 잘 일치하며 정략적 및 정성적 분석을 수행하였다. 인히비터 후방에서 발생하는 vortex는 Flow-acoustic coupling 에 의해 주기적으로 반복되며 생성, 소멸이 이루어지는 것을 확인 할 수 있었으며, 발생 주기는 연소실내 mode 2의 주파수와 일치하는 것을 확인하였다. 3차원 해석결과 인히비터 후방에서 Roll 발생은 비균일한 노즐 유동을 발생시킨다.

  • PDF

소형풍력발전을 위한 3상 단일전력단 교류-직류 컨버터 (3-Phase Single Stage AC-DC Converter for Small Wind Turbine System)

  • 문유진;박범수;김상규;김은수;임덕진
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.68-75
    • /
    • 2023
  • This paper proposes a three-phase single-stage AC-DC converter for the small wind generation system. Input power factor improvement and insulated output can be implemented with the proposed three-phase single-stage AC-DC converter under the wide power generation voltage (80-260 Vac) and frequency (10-42 Hz) in a small wind power generation (WPG) system. The proposed converter is also capable of zero-voltage switching in the primary-side switches and zero-current switching in the secondary-side diodes by phase-shift control at a fixed switching frequency. In addition, it is possible to control a wide output voltage (Vo: 39 VDC-60 VDC) by varying the link voltage and improving the input power factor (PF) and the total harmonic distortion factor (THDi). Simulation and experimental results verified the validity of the proposed converter.