• Title/Summary/Keyword: Frequency Domain Reflectometry

Search Result 98, Processing Time 0.021 seconds

Comparisons of Soil Water Retention Characteristics and FDR Sensor Calibration of Field Soils in Korean Orchards (노지 과수원 토성별 수분보유 특성 및 FDR 센서 보정계수 비교)

  • Lee, Kiram;Kim, Jongkyun;Lee, Jaebeom;Kim, Jongyun
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.401-408
    • /
    • 2022
  • As research on a controlled environment system based on crop growth environment sensing for sustainable production of horticultural crops and its industrial use has been important, research on how to properly utilize soil moisture sensors for outdoor cultivation is being actively conducted. This experiment was conducted to suggest the proper method of utilizing the TEROS 12, an FDR (frequency domain reflectometry) sensor, which is frequently used in industry and research fields, for each orchard soil in three regions in Korea. We collected soils from each orchard where fruit trees were grown, investigated the soil characteristics and soil water retention curve, and compared TEROS 12 sensor calibration equations to correlate the sensor output to the corresponding soil volumetric water content through linear and cubic regressions for each soil sample. The estimated value from the calibration equation provided by the manufacturer was also compared. The soil collected from all three orchards showed different soil characteristics and volumetric water content values by each soil water retention level across the soil samples. In addition, the cubic calibration equation for TEROS 12 sensor showed the highest coefficient of determination higher than 0.95, and the lowest RMSE for all soil samples. When estimating volumetric water contents from TEROS 12 sensor output using the calibration equation provided by the manufacturer, their calculated volumetric water contents were lower than the actual volumetric water contents, with the difference up to 0.09-0.17 m3·m-3 depending on the soil samples, indicating an appropriate calibration for each soil should be preceded before FDR sensor utilization. Also, there was a difference in the range of soil volumetric water content corresponding to the soil water retention levels across the soil samples, suggesting that the soil water retention information should be required to properly interpret the volumetric water content value of the soil. Moreover, soil with a high content of sand had a relatively narrow range of volumetric water contents for irrigation, thus reducing the accuracy of an FDR sensor measurement. In conclusion, analyzing soil water retention characteristics of the target soil and the soil-specific calibration would be necessary to properly quantify the soil water status and determine their adequate irrigation point using an FDR sensor.

Effect of Drainpipe Height and Media Composition on Growth and Yield of Soilless Cultivated Cut Rose in Container Culture (절화장미 용기재배 시 배수구 높이, 배지조성이 생육과 수량에 미치는 영향)

  • Choi, Gyeong-Lee;Cho, Myeong-Whan;Cheong, Jae-Woan;Roh, Mi-Young;Rhee, Han-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.240-245
    • /
    • 2010
  • The objective of this study was to determine the effect of different height of drainpipe and growing media soilless cultivated cut rose in container culture. Two experiment were to examine the effect of the drainpipe height and media composition on yield and quality of cut rose, Four different drainpipe height (0, 3, 6, 9 cm) were treated to determine of optimal container type. Yield was the highest at 3 cm drainpipe height, but quality was not significantly affected by drainpipe height. Survival rate of rose was 100%, 100%, 92%, and 92%, respectively. Two different drainpipe height (0, 3 cm) and 7 media composition (pure coir and pelite, and mixed with two media 3 : 1, 2 : 1, 1 : 1, 1 : 2, 1 : 3 v/v) was treated to determine of media composition related to drainpipe height. The supply of nutrient solution was controlled by the signal of water potential at -5 kPa using frequency domain reflectometry (FDR) sensor in mixed coir with pelite 3 : 1, 1 : 1, 1 : 3 (v/v), respectively. Irrigation frequency reduced in high ratio of coir media and 3 cm height of drainpipe. Quality of cut rose except for flower weight and yield until 2nd harvest was not significantly affected by drainpipe height, but yield after 3rd was higher at 3 cm than 0 cm height of darinpipe. In the media composition, yield and qulity of cut rose was increased at high ratio of coir media.

Partial Discharge Characteristics and Localization of Void Defects in XLPE Cable (XLPE 케이블에서 보이드 결함의 부분방전 특성과 위치추정)

  • Park, Seo-Jun;Hwang, Seong-Cheol;Wang, Guoming;Kil, Gyung-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.203-209
    • /
    • 2017
  • Research on condition monitoring and diagnosis of power facilities has been conducted to improve the safety and reliability of electric power supply. Although insulation diagnostic techniques for unit equipment such as gas-insulated switchgears and transformers have been developed rapidly, studies on monitoring of cables have only included aspects such as whether defects exist and partial discharge (PD) detection; other characteristics and features have not been discussed. Therefore, this paper dealt with PD characteristics against void sizes and positions, and with defect localization in XLPE cable. Four types of defects with different sizes and positions were simulated and PD pulses were detected using a high frequency current transformer (HFCT) with a frequency range of 150kHz~30MHz. The results showed that the apparent charge increased when the defect was adjacent to the conductor; the pulse count in the negative half of the applied voltage was about 20% higher than that in the positive half. In addition, the defect location was calculated by time-domain reflectometry (TDR) method, it was revealed that the defect could be localized with an error of less than1m in a 50m cable.

Effect of EC Level of Nutrient Solution on the Yield and Quality of Cut Rose Based on Mixed Coir and Perlite (코이어와 펄라이트 혼합배지를 이용한 절화장미 수경재배 시급액농도가 수량 및 품질에 미치는 영향)

  • Choi, Gyeong-Lee;Cho, Myeong-Whan;Seo, Tae-Cheol;Roh, Mi-Young;Rhee, Han-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.18 no.4
    • /
    • pp.348-353
    • /
    • 2009
  • Organic materials reveal the remarkable absorption and high buffer capacity for nutrient. Hence, organic materials need some different nutrient management skill from inorganic one. The objective of this study was to evaluate the effect of EC level of nutrient solution on the yield and quality of cut rose grown in the mixed substrate of coir and perlite. 3 EC levels of nutrient solution was treated, which were 0.7, 1.0, 1.3 times of standard solution (Aichiken solution, Japan) for cut rose hydroponics. EC of the standard solution was changed by season following as 1.4 (Apr.~June), 1.0 (July~Aug.), 1.4 (Sep.~Oct.), and $1.6dS{\cdot}m^{-1}$ (Nov.~Mar.) subsequently. The supply of nutrient solution was controlled by the signal of water potential at -5kPa using frequency domain reflectometry (FDR) sensor. As the results, marketable yield was similar for all treatments until 3rd harvest, but was decreased in high EC level from 4th harvest to 7th harvest as final. 0.7 times of standard solution decreased the ratio of unmarketable rose having short stem below 70cm and increased the ratio of high quality rose having long stem above 91cm. The flower weight and stem diameter of cut rose was higher in the low EC treatment than the others.

Moisture Contents Setting according to Growth Stages of when the Cultivation of Gastrodia elata in Indoor Facilities (천마 실내시설재배 시 생육단계별 수분함량 설정)

  • Kim, Chang Su;Kim, Hyo Jin;Seo, Sang Young;Ahn, Min Sil;Kim, Hee Jun;Lee, Wang Hyu
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2018.10a
    • /
    • pp.77-77
    • /
    • 2018
  • 천마(Gastrodia elata)는 연중생산을 위해 실내시설 재배 시 생육모델을 구죽하고, 생육단계에 따른 온도, 수분, $CO_2$ 등 환경 조건 설정이 필요하다. 본 연구는 천마의 생육단계 중 괴경형성기와 괴경비대기의 수분함량을 설정하여 최적의 환경조건을 찾기 위해 수행하였다. 먼저 괴경형성기 수분함량 공급은 괴경형성기에 -20kPa, -30kPa, -40kPa로 처리하여 120일간 배양한 뒤, 괴경비대기를 -40kPa로 고정하여 60일간 배양하였다. 반면, 괴경비대기 수분함량 공급은 괴경형성기를 -30kPa로 고정하여 120일간 배양한 뒤 괴경비대기에 -20kPa, -30kPa, -40kPa, -50kPa로 처리하여 60일간 배양하였다. Tensiometer(토양수분장력계)기를 설치하여 수분을 공급하였고, FDR센서 (UbiMas, CoCo sensor, Frequency domain reflectometry type)를 배양토의 깊이 5 cm와 15 cm에 2개를 설치하여 평균값으로 수분함량을 측정하였으며, 전체수량, 성마율, 종마율 등을 조사하였다. FDR센서로 수분함량을 측정한 결과, -20 kPa은 43.3%, -30 kPa은 34.7%, -40 kPa은 29.8%, -50 kPa은 25.3%로 측정되었다. 괴경형성기 수분함량 처리 후 수확기의 상자 당 전체수량은 -30 kPa일 때 985 g으로 가장 많았고, -40 kPa일 때 912 g, -20 kPa일 때 703 g으로 처리간의 유의적인 차이를 보였다. 성마율은 수분함량처리별 각각 25, 34, 30% 이었고, 종마율은 수분함량처리별 각각 53, 73, 65%로 나타났다. 따라서 -30 kPa 처리구가 다른 처리구에 비해 전체수량, 성마율, 종마율 등이 유의적으로 우수하였다. 괴경비대기 수분 함량 처리 후 수확기의 상자 당 전체수량은 -40 kPa일 때 992 g으로 가장 많았고, -50 kPa일 때 955 g, -30 kPa일 때 903 g, -20 kPa일 때 686 g 순으로 나타났다. -30 kPa에서 -50 kPa 사이에서는 전체 수량의 유의성 차이는 없었다. 성마율은 수분함량처리별 각각 20, 30, 35, 33%이었고, 종마율은 수분함량처리별 각각 45, 65, 75, 68%로 나타났다. 따라서 -40 kPa 처리구가 다른 처리구에 비해 전체수량, 성마율, 종마율 등이 유의적으로 우수하였다. 반면 -20 kPa 처리구는 과도한 수분으로 천마가 오히려 부패될 수 있는 환경조건이 조성됨에 따라 성마율, 종마율 등 전체적인 수량 감소에 영향을 미친 것으로 판단되었다.

  • PDF

Effect of Plant Growth and Production of Tomato on the Water Content Control in Rockwool Culture (암면배지의 수분제어가 토마토의 생육 및 생산성에 미치는 영향)

  • Moon, Doo-Gyung;Kim, So-Hee;Cho, Myeng-Whan;Yu, In-Ho;Ryu, Hee-Ryong;Choi, Kyung-Hee;Kwon, Yong-Hee;Lee, So-Jin
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.2
    • /
    • pp.183-189
    • /
    • 2018
  • This study was carried out to investigate the effect of plant growth and production of tomato (Lycopersicon Esculentum Mill cv. Tefunis) according to the water content of non-recycled rockwool culture in high-rise tomato greenhouse. Daily irrigation amount was 3.8 times higher in the irrigation control by Integrated Solar Radiation (ISR) than in the Frequency Domain Reflectometry (FDR) sensor. Water content of ISR and FDR was 90-95 and 60-65%, respectively. Plant height and weight of tomato fruit was 1.2-1.9 times longer and 1.2-2.0 times heavier in the ISR than in the FDR sensor, respectively. No significantly differed to sugar content of tomato by treatments. Marketable fruits were the higher 1.3 times in the ISR compared with the FDR sensor. Cracking percentage in the ISR was also the higher 2.0 times compared with FDR sensor. Therefore, Irrigation control by ISR was appropriate to improve of plant growth and production of tomato with non-recycled rockwool culture in greenhouse during long-term cultivation.

Irrigation Control for Improving Irrigation Efficiency in Coir Substrate Hydroponic System (코이어 배지 수경재배에서 관수효율 향상을 위한 급액 제어)

  • Yoo, Hyung-Joo;Choi, Eun-Young;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.153-160
    • /
    • 2015
  • The objectives of this study were to determine optimal length of off-time between irrigation cycles to improve irrigation efficiency using a frequency domain reflectometry (FDR) sensor-automated irrigation (FAI) system for tomato (Solanum lycopersicum L.) cultivation aimed at minimizing effluent from coir substrate hydroponics. For treatments, the 5-minute off-time length between 3-minute run-times (defined as 3R5F), 10-minute off-time length between 3-minute run-times (defined as 3R10F), or 15-minute off-time length between 5-minute run-times (defined as 5R15F) were set. During the 3-minute or 5-minute run-time, a 60mL or 80mL of nutrient solution was irrigated to each plant, respectively. Until 62 days after transplant (DAT) during the autumn to winter cultivation, daily irrigation volume was in the order of 3R5F (858mL) > 5R15F (409mL) > 3R10F (306mL) treatment, and daily drainage ratio was in the order of 3R5F (44%) > 5R15F (23%) > 3R10F (14%). Between 63 and 102 DAT, daily irrigated volume was in the order of 5R15F (888mL) > 3R5F (695mL) > 3R10F (524mL) with the highest drainage ratio, 19% (${\pm}2.6$), at the 5R15F treatment. During the spring to summer cultivation, daily irrigation volume and drainage ratio per plant was higher in the 3R5F treatment than that of the 3R10F treatment. For both cultivations, a higher water use efficiency (WUE) was observed under the 3R10F treatment. Integrated all the data suggest that the optimal off-time length is 10 minutes.

Comparisons in Volumes of Irrigation and Drainage, Plant Growth and Fruit Yield under FDR Sensor-, Integrated Solar Radiation-, and Timer-Automated Irrigation Systems for Production of Tomato in a Coir Substrate Hydroponic System (토마토 코이어 수경재배에서 FDR센서, 적산일사량센서 및 타이머 급액방식에 따른 급배액량, 생육 및 과실수량 비교)

  • Choi, Eun-Young;Kim, Hee-Yong;Choi, Ki-Young;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.25 no.1
    • /
    • pp.63-70
    • /
    • 2016
  • Water drainage from the open hydroponics often causes significant environmental pollution due to agrochemicals and loss of water and nutrients. The objectives of this study were to show the potential application of an irrigation schedule based on threshold values of volumetric substrate water content for tomato (Solanum lycopersicum L. 'Samsamgu') cultivation in a commercial hydroponic farm during spring to summer cultivation. This study was performed for minimizing effluent from coir substrate hydroponics using a frequency domain reflectometry (FDR) sensor-automated irrigation, as compared with an integrated solar-radiation (IR) and conventional timer-irrigation (TIMER) after transplanting. In results, no significant difference in daily irrigation volume was found among the treatments until 88 days after transplant (DAT). However, during the 88 to 107 DAT, the daily irrigation volume was in the order of IR (2125 mL) > TIMER (2063 mL) > FDR (1983 mL), and during the 108 to 120 DAT, it was in the order of IR (2000 mL) > TIMER (1664 mL) > FDR (1500 mL). The lowest drainage volume was observed in the FDR treatment with the order of IR (12~19%) > TIMER (4~12%) > FDR (0~7%) during the entire growing period. A lower irrigation volume in the FDR treatment after 88 DAT may be due to the sensor's detecting capacity for less water absorption by plant after completing fruit maturity with apical pruning and removal of lower leaves, while a higher irrigation volume in the IR treatment may be due to gradual increase in integrated solar-radiation amount as closer to summer season. There was no significant difference in plant growth and fruit yield among the treatments; however, a 11% and 18% of higher soluble sugar content was observed in the FDR than that of TIMER and IR treatment. respectively.