• 제목/요약/키워드: Frequency (Hz)

검색결과 5,141건 처리시간 0.032초

샘플링율이 맥박변이도 시간 및 주파수 영역 분석에 미치는 영향 (An Effect of Sampling Rate to the Time and Frequency Domain Analysis of Pulse Rate Variability)

  • 양윤라;신항식
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1247-1251
    • /
    • 2016
  • This study aims to investigate the effect of sampling frequency to the time domain and frequency domain analysis of pulse rate variability (PRV). Typical time domain variables - AVNN, SDNN, SDSD, RMSSD, NN50 count and pNN50 - and frequency domain variables - VLF, LF, HF, LF/HF, Total Power, nLF and nHF - were derived from 7 down-sampled (250 Hz, 100 Hz, 50 Hz, 25 Hz, 20 Hz, 15 Hz, 10 Hz) PRVs and compared with the result of heart rate variability of 10 kHz-sampled electrocardiogram. Result showed that every variable of time domain analysis of PRV was significant at 25 Hz or higher sampling frequency. Also, in frequency domain analysis, every variable of PRV was significant at 15 Hz or higher sampling frequency.

가두리 양식장 주변의 수중환경소음과 생물소음의 특성에 관한 연구 (A Study on the Characteristics of the Underwater Ambient Noise and Biological Noise in Fish Farm Cages)

  • 박태건
    • 수산해양기술연구
    • /
    • 제35권1호
    • /
    • pp.41-49
    • /
    • 1999
  • This paper describes to analyze the underwater ambient noise and biological noise of cultivating fishes in the fish farm cages at the seawater Tongyong-kun, KyongNam and lake of Chungju, Chech'on, ChungBuk from 10 to 19 Oct. 1997, in order to find out the characteristics of these noises. The results obtained were as follows; (1) The ambient noise around the fish farm cages at lake of Chungju was 10~200Hz frequency range, 70~105dB spectrum level. The central frequency was 50~70Hz, changing of ambient noise was getting bigger than 10~200Hz in 200Hz~2kKz frequency by wind, water current. (2) The frequency of noise source around the fish farm cage at the seawater of Tongyong-kun was 20~200Hz, spectrum level was 80~100dB while feed factory was working around the fish farm cage. When feed factory did not work, noise source was 10~600Hz frequency range, 70~90dB spectrum level. It was 10dB less than that of while feed factory was working, and then the central frequency was 70Hz. (3) The vessel noise of excursion ship had changed largely at 100dB spectrum level in 10~500Hz frequency band, and the fishing boat had 20Hz~2kHz frequency range. (4) The biological noise in the fish farm cage at lake of Chungju, which was feeding of Cyprinus carpio, 2was 10~30Hz frequency, 70~104dB spectrum level. The central frequency was 75Hz. The biological noises in the fish farm cage at the seawater of Tongyong-kun, which were feeding and swimming noise, had very different spectrum pattern by species, and the frequency band was 10~800Hz.

  • PDF

가청 주파수 영역의 고주파와 순환 중복 검사를 이용한 무선 데이터 전송 알고리즘 (Wireless Data Transmission Algorithm Using Cyclic Redundancy Check and High Frequency of Audible Range)

  • 정명범
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제4권9호
    • /
    • pp.321-326
    • /
    • 2015
  • 본 논문에서는 가청 주파수 영역 중 사람들에게 거의 들리지 않는 고주파와 순환 중복 검사 기법을 이용하여 스마트 기기 간의 신뢰성 있는 데이터를 무선으로 전송하는 알고리즘을 제안한다. 제안 알고리즘은 스마트 기기의 내장 스피커에서 출력할 수 있는 가청 주파수 영역(20 Hz~22 kHz) 중 고주파 영역인 18 kHz~22 kHz를 사용한다. 이때 데이터의 전송량을 높이기 위해 고주파 영역 1(18.0 kHz~21.2 kHz)에서 여러 개의 주파수를 혼합하여 전달하며, 이와 동시에 전송 데이터의 정확성을 높이기 위해 고주파 영역 2(21.2 kHz~22.0 kHz)에서 순환 중복 검사를 위한 체크섬을 전달한다. 제안 방법의 데이터 전송 속도와 정확성을 확인하기 위해 스마트 북과 스마트 기기 간에 데이터 전달 실험을 하였다. 그 결과 평균 235 ms에 32 bits 데이터를 전송할 수 있었으며, 전송 성공률은 99.47%, 그리고 순환 중복 검사에 의한 에러 검출률은 0.53%인 것을 확인하였다. 따라서 제안 방법은 스마트 기기 간에 무선으로 데이터를 전송할 수 있는 유용한 기술이 될 것이다.

천부 탄성파 반사법 자료의 주파수 특성 - 강원도 삼척시 도계지역 (Frequency Characteristics of Shallow Seismic Reflection Data - Dogye, Samchuck, Kangwon)

  • 고광범;이두성
    • 지구물리와물리탐사
    • /
    • 제3권1호
    • /
    • pp.19-24
    • /
    • 2000
  • 28 Hz와 100 Hz 지오폰을 사용하여 탄광 채굴공동에 의한 지반침하 지역에서 탄성파자료를 획득하고 지오폰에 따른 탄성파 자료의 주파수 특성을 고찰하였다. 파동의 전파거리가 짧아 고주파수 성분의 감쇠가 적은 근거리 오프셋($1\~10m$) 에서는 100 Hz 지오폰 자료가 28 Hz 지오폰 자료에 비하여 상당히 높은 주파수 성분(최대 300 Hz)을 보유하며 중거리 오프셋($11\~39m$)에서는 28Hz 지오폰 자료의 신호대역 주파수 특성은 근거리 오프셋 자료와 전체적으로 유사하고 100 Hz 지오폰의 경우는 신호로 간주할 수 있는 최대 주파수는 높은 반면 상대적으로 높은 수준의 고주파 잡음이 존재하며, 원거리 오프셋($\geq40\;m$)에서는 150 Hz 이상의 영역에서 신호가 대부분 잡음수준까지 감쇠된 결과를 보여주었다.

  • PDF

60Hz 절연변압기가 없는 고주파링크방식 계통연계형 태양광발전시스템 고찰 (Study of 60Hz Transformer-less High Frequency Linked Grid-Connected Power Conditioners for Photovoltaic Power System)

  • 유권종;정영석;최주엽
    • 전력전자학회논문지
    • /
    • 제7권6호
    • /
    • pp.563-569
    • /
    • 2002
  • 본 연구는 60Hz 절연변압기가 없는 형태의 고주파링크방식의 계통연계형 PCS(Power Conditioning System)를 개발하였다. 본 시스템은 고주파 DC-DC 컨버터, 고주파 절연변압기, 풀브리지 다이오드 정류기, DC filter, 저주파 인버터, LC 필터로 구성되어 있다. 고주파 DC-DC 컨버터는 20kHz의 bipolar PWM 펄스를 발생시키며, 이 펄스는 고주파 절연변압기를 통해 승압되고, 풀브리지 다이오드를 통해 정류된다. 마지막으로 저주파 인버터를 통해 정현파 전류가 계통에 유입되게 된다. 제안한 고주파링크방식의 시스템은 기존의 60Hz 절연변압기를 사용하는 시스템 보다 많은 스위칭 소자가 사용되지만, 60Hz 절연변압기를 생략함으로서 시스템의 소형경량화 및 저가화를 이룰 수 있었다.

시-주파수 분석을 이용한 심실세동시 심전도 분석을 통한 제세동 예측에 관한 연구 (Prediction of Defibrillation Success of Ventricular Fibrillation ECG Signals using Time-Frequency Analysis)

  • 성홍모;신재우;이현숙;황성오;윤영로
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권4호
    • /
    • pp.181-188
    • /
    • 2006
  • The purpose of this study is to predict the defibrillation success of a ventricular Fibrillation ECG signal using time-frequency analysis. During CPR, coronary perfusion pressure and electrocardiogram were measured. Parameters extracted from time-frequency domain were served as predictor of resuscitation success. Time frequency distribution(TFD) of ECG signals was estimated from the smoothed pseudo Wigner-Ville distribution(SPWVD). Median frequency, peak frequency, 1/f slope, frequency band ratios$(2{\sim}4Hz,\;4{\sim}6Hz,\;6{\sim}8Hz,\;8{\sim}10Hz,\;10{\sim}12Hz,\;12{\sim}15Hz)$ were extracted from each TFD as function of time. Paired t-test was used to determine the differences in ROSC and non-ROSC groups. In the statistical results, we selected four significant parameters - median frequency, 1/f slope, $2{\sim}4Hz$ band ratio, $8{\sim}10Hz$ band ratio. We made an attempt to predict defibrillation success by combining features extracted from time frequency distribution. Independent t-test was used to determine the differences ROSC and non-ROSC groups. Consequently, we selected four significant parameters-median frequency, 1/f slope, $2{\sim}4Hz$ band ratio, $8{\sim}10Hz$ band ratio. The relationship between coronary perfusion pressure and ECG parameters was analyzed with linear regression analysis. R-square value was 55%. 1/f slope and $8{\sim}10Hz$ band ratio had the significant relationship with coronary perfusion pressure.

상용전원 주파수(60Hz)를 사용한 중전력 무선전력전송 연구 (Research on Medium-power Wireless Power Transmission using Commercial Power Frequency (60Hz))

  • 이기범
    • 한국전자통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.497-506
    • /
    • 2024
  • 본 논문에서는 상용전원 주파수(60 Hz)를 사용하여 중전력 무선전력전송을 구현한 것이다. 일반적인 자기유도 무선전력전송 장치는 수십 kHz 이상 사용하기 때문에 상용전원 주파수(60 Hz)를 그대로 사용할 수 없고, 교류/직류 변환기를 사용하여 60 Hz 전원주파수를 DC로 만들고, 고주파 파워앰프를 사용하여 DC를 수십 KHz로 만들어서 사용한다. 자기유도 무선전력전송에서 교류/직류 변환기와 고주파 파워앰프를 제거하고, 송전 공진탱크, 송전코일, 수전 공진탱크, 수전코일 만으로 구성한 상용전원 주파수를 사용하는 극저주파 무선전력전송 시스템을 구현하고, 무선전력전송 실험으로 검증하였다.

36kHz 초음파 반응기에서의 원주파수 및 파생주파수의 음압 분포 분석 (The Analysis of Acoustic Emission Spectra in a 36 kHz Sonoreactor)

  • 손영규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권6호
    • /
    • pp.128-134
    • /
    • 2016
  • Acoustic emission spectra was analyzed to investigate the distribution of sound pressure in a 36 kHz sonoreactor. The sound pressure of fundamental frequency (f: 36 kHz), harmonics (2f: 72 kHz, 3f: 108 kHz, 4f: 144 kHz, 5f: 180 kHz, 6f: 216 kHz), and subharmonics (1.5f: 54 kHz, 2.5f: 90 kHz, 3.5f: 126 kHz, 4.5f: 162 kHz, 5.5f: 198 kHz, 6.5f; 234 kHz) was measured at every 5 cm from the ultrasonic transducer using a hydrophone and a spectrum analyzer. It was revealed that the input power of ultrasound, the application of mechanical mixing, and the concentration of SDS affected the sound pressure distributions of the fundamental frequency and total detected frequencies frequencies significantly. Moreover a linear relationship was found between the average total sound pressure and the degree of sonochemical oxidation while there was no significant linear relationship between the average sound pressure of fundamental frequency and the degree of sonochemical oxidation.

혐기성 소화 효율 향상을 위한 초음파 주파수의 순차적 적용에 대한 연구 (A Study on Sequential-Frequency Sonication for Improving Anaerobic Digestion)

  • 황규대;박성한
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.893-906
    • /
    • 2011
  • The effect of ultrasound pretreatment on sludge degragability was investigated at different condotions: ultrasonic frequency(28, 40, 50kHz), intensity(10, 25, 50W), sonication time(10, 20, 30, 60min). Total suspended solid(TSS) and soluble chemical oxygen demand(SCOD) concentration were measured for the evaluation of pretreatment efficiency. The pretreated sludge was used as the feedstock for anaerobic digestion process. Biogas production and volatile suspended solid(VSS) removal were determined for evaluating the process performance. 1. TSS concentration of the sludge decreased at a constant rate as sonication operation was applied. The degradation rate of TSS increased when ultrasound frequency was decreased from 50kHz to 28kHz and intensity was increased from 10W to 50W. Efficiency of TSS degradation per input energy increased as ultrasonic frequency and intensity were decreased. At the frequency of 28 and 40kHz, SCOD concentration rapidly increased during the initial 30min of sonication time, and then it gradually increased. At 50kHz, SCOD concentration constantly increased for 60min of the sonication time. The SCOD production rate increased with increasing intensity under all ultrasound frequencies. 2. The optimum condition of ultrasound treatment was 28kHz, 50W and 60min for maximizing the biogas production, methane fraction, VSS removal. The highest values in biogas production, methane fraction in biogas, VSS removal were 370ml, 70%, 2.45g, respectively. Methane production rate per input energy increased at ultrasonic frequency and intensity decreased. 3. When raw sludge was pretreated at the condition of ultrasonic frequency of 28 and 40kHz in series, sequential-frequency sonication, intensity of 50W and 60min, biogas production, methane fraction, VSS removal were about the same that of 28kHz single-frequency sonication. When sequential-frequency sonication of 28 and 50kHz was applied in series, biogas production, methane fraction, VSS removal were 356 ~ 423ml, 69 ~ 71%, 2.41 ~ 2.78g, respectively. The pretreatment efficiency of 28-50kHz sequential-frequency sonication which sonication time of 28kHz and 50kHz was 40min and 20min was higher than that of 28kHz single-frequency sonication.

한국 성인 음성의 음도인식에 관한 연구 (A Study on Pitch Perception of Normal Korean)

  • 정옥란;김형순;김영태;서장수
    • 음성과학
    • /
    • 제1권
    • /
    • pp.315-323
    • /
    • 1997
  • This study attempts to determine the fundamental frequency level of male and female voices that Koreans perceive as normal. Seventy-three college students majoring in Speech Pathology participated in the study on a voluntary basis. The subjects listened to a male voice with fundamental frequency of 60 Hz, 80 Hz, 100 Hz, 120 Hz, 140 Hz, 160 Hz, 180 Hz, and 200 Hz, and a female voice with fundamental frequency of 140 Hz, 160 Hz, 180 Hz, 200 Hz, 220 Hz, 240 Hz, 260 Hz, and 280 Hz. The PSOLA (Pitch Synchronous Overlap). method and harmonic modeling method of speech signal were used to change pitch in the 20 Hz interval. The voices were presented in a random order to prevent listener bias. The results were as follows; Firstly, $46.6\%$ judged male voice with 120 Hz as normal, and $19.2\%$ judged 140 Hz as normal, and another $19.2\%$ judged 160 Hz as normal. Secondly, $50.7\%$ perceived female voice with 220 Hz as normal, and $32.9\%\;and\;30.1\%$ responded to 200 Hz and 240 Hz, respectively. The problems and recommendations for a future investigation are discussed.

  • PDF