• 제목/요약/키워드: Freezing temperature

검색결과 909건 처리시간 0.03초

Three Cases with the Multiple Occurrences of Freezing Rain in One Day in Korea (12 January 2006; 11 January 2008; and 22 February 2009)

  • Park, Chang-Kyun;Byun, Hi-Ryong
    • 대기
    • /
    • 제25권1호
    • /
    • pp.31-49
    • /
    • 2015
  • From the hourly data of 75 Korean weather stations over a 12-year period (2001~2012), this study has chosen three cases (January 12, 2006; January 11, 2008; and February 22, 2009) of multiple freezing rains and investigated the atmospheric circulations that seemed to cause the events. As a result, the receding high pressure type (2006), prevailing high pressure type (2008), and warm front type (2009) are confirmed as synoptic patterns. In all three cases, freezing rain was found in regions with a strong ascending current near the end point of a low-level jet that carried the warm humid air from low latitudes. The strong ascending current resulted from lower-level convergence and upper-level divergence. In 2006 and 2009, the melting process was confirmed. In 2008, the supercooled warm rain process (SWRP) was confirmed. In contrast to existing SWRP theory, it was found that the cool air produced at the middle atmosphere and near the earth's surface led to the formation of freezing rain. The sources of this cool air were supposed to be the evaporative latent heat and the cold advection coming from the northeast. On the other hand, a special case was detected, in which the freezing rain occurred when both the soil surface temperature and surface air temperature were above $0^{\circ}C$. The thickness distributions related to freezing rain in Korea were found to be similar to those in North America. A P-type nomogram was considered for freezing rain forecasting; however, it was not relevant enough to Korea, and few modifications were needed.

동결건조 시스템에서 동결속도가 향미물질 보존에 미치는 영향 (Influence of Freezing Rate on the Aroma Retention in a Freeze Drying System)

  • 변명희;최미정;이성;민상기
    • 한국축산식품학회지
    • /
    • 제18권2호
    • /
    • pp.176-184
    • /
    • 1998
  • The objective of this study was to investigate the effects of freezing rate on aroma retention and to examine the mechanism of aroma retention during freeze drying process. Our experiments were carried out with self-manufactured freeze-dryer. Gelatin gels (2% w / w, 80${\times}$20mm) containing diacetyl(2mg/ml) were frozen unidirectionally (Neumann's model) from the bottom at -45, -30, -20, and -15$^{\circ}C$ and followed with freeze-drying. Under the upper conditions we measured freezing rate and the change of temperature and pressure during freeze drying. Freeze-dried gelatins were cut horizontally into 5 mm thickness from the bottom measured and diacetly contents. Besides, we observed the effect of the relative humidity of the diacetyl contents freeze-dried gelatin during storage. The retained diacetyl content was increased at high freezing temperature and in order of 0∼5, 5∼10, 10∼15, 15∼20 mm section from the bottom of the sample. It was observed that the retained diacetyl content was high in 15∼20 mm section. The retained diacetyl content and freeze-dried gelatin stored in the condition of high relative humidity was decreased significantly but in the low relative humidity case, was it decreased in small amount. The results of our experiment resents that the low temperature freezing and low humidity storing condition is effective for preserving aroma compound in food.

  • PDF

Experimental and numerical investigation of closure time during artificial ground freezing with vertical flow

  • Jin, Hyunwoo;Go, Gyu-Hyun;Ryu, Byung Hyun;Lee, Jangguen
    • Geomechanics and Engineering
    • /
    • 제27권5호
    • /
    • pp.433-445
    • /
    • 2021
  • Artificial ground freezing (AGF) is a commonly used geotechnical support technique that can be applied in any soil type and has low environmental impact. Experimental and numerical investigations have been conducted to optimize AGF for application in diverse scenarios. Precise simulation of groundwater flow is crucial to improving the reliability these investigations' results. Previous experimental research has mostly considered horizontal seepage flow, which does not allow accurate calculation of the groundwater flow velocity due to spatial variation of the piezometric head. This study adopted vertical seepage flow-which can maintain a constant cross-sectional area-to eliminate the limitations of using horizontal seepage flow. The closure time is a measure of the time taken for an impermeable layer to begin to form, this being the time for a frozen soil-ice wall to start forming adjacent to the freeze pipes; this is of great importance to applied AGF. This study reports verification of the reliability of our experimental apparatus and measurement system using only water, because temperature data could be measured while freezing was observed visually. Subsequent experimental AFG tests with saturated sandy soil were also performed. From the experimental results, a method of estimating closure time is proposed using the inflection point in the thermal conductivity difference between pore water and pore ice. It is expected that this estimation method will be highly applicable in the field. A further parametric study assessed factors influencing the closure time using a two-dimensional coupled thermo-hydraulic numerical analysis model that can simulate the AGF of saturated sandy soil considering groundwater flow. It shows that the closure time is affected by factors such as hydraulic gradient, unfrozen permeability, particle thermal conductivity, and freezing temperature. Among these factors, changes in the unfrozen permeability and particle thermal conductivity have less effect on the formation of frozen soil-ice walls when the freezing temperature is sufficiently low.

내한제 및 단열거푸집을 이용한 한중콘크리트의 모의구조체 적용에 관한 실험 연구 (An Experimental Study on the Mock-up Test of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form)

  • 김경민;손성운;김기철;오선교;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.663-668
    • /
    • 2002
  • In this paper, insulating effects and strength development of concrete placed at mock up model structure are discussed using anti freezing agent and insulating forms. According to test results, concrete containing 8% of anti freezing agent shows lower freezing temperature, earlier setting time and higher strength development than plain concrete. As for the temperature history of mock up structures, when plain concrete is placed at euro form, the temperature drops to -4${\circ}$ before early 24 hours, and when concrete containing anti freeze agent at euro form, it to -3${\circ}$ before early 24 hours. Nevertheless, when concrete containing anti freeze agent is placed at insulating form, it does not go below zero, and the concrete containing anti freeze agent enhances higher strength development.

  • PDF

2차원 직사각형 덕트 내부에 돌기부를 갖는 흐름의 동결특성에 관한 연구 (Freezing Characteristics in a Horizontal Rectangular Channel with the Two-Dimensional Protuberances)

  • 오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.721-727
    • /
    • 2003
  • Freezing of turbulent water flow between two horizontal cooled parallel plates with the separated region has been investigated experimentally. The flow separation was induced by vertical plates (two-dimensional plates) situated at the inlet of the rectangular channel. The degree of flow separation was varied by employing vertical thin plates with various heights. Three kinds of the vertical plates with 8.0, 9.8 and 12.5 mm in height were utilized. The Reynolds number and cooling temperature ratio were ranged from $3.45\times10^3 to 1.73\times10^4$ and 7.0 to 20.0 respectively, The measurements show that the flow separation influenced remarkably on the local ice formation characteristics. The location of the first ice layer and the average heat transfer at the ice surface were found be correlated as a function of the Reynolds number, the cooling temperature ratio, and the orifice height ratio.

휜이 부착된 수직(垂直) 냉각관(冷却管)에서의 열전달(熱傳達)에 관(關)한 실험적(實驗的)인 연구(硏究) (An experimental study on heat transfer of finned vertical cooling tube)

  • 송하진;이채문;임장순
    • 태양에너지
    • /
    • 제4권2호
    • /
    • pp.43-49
    • /
    • 1984
  • Experiments were performed to study freezing on a finned vertical tube when either conduction in the solid or natural convection in a liquid controls the heat transfer. Conduction is the controlling mode when the liquid is at its fusion temperature, whereas natural convection controls when the liquid temperature is above the fusion value. The liquid was housed in a cylinderical containment vessel whose surface was maintained at a uniform, time-invariment temperature during a data run, and the freezing occurred on a finned vertical tube positioned along the axis of the vessel. The phase change medium was n-octacosan, a paraffin which freezes at about $61^{\circ}C$. For conduction-controlled freezing, the enhancement of the frozen mass due to finning is greatest when the frozen layer is thin and decrease as the layer grows thicker. The degree of enhancement is generally less than the surface area ratio of the finned and unfinned tube.

  • PDF

국내 시판 방동제의 동결온도 특성 (Freezing Temperature Properties of Anti-freeze Agency in Domestic)

  • 노상균;이건철;조병영;김영근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.383-384
    • /
    • 2010
  • 본 연구에서는 방동제의 동결온도 측정방법 및 국내에서 시판되는 방동제의 동결온도 특성을 조사하였다. 방동제 종류는 아질(초)산계 방동제를 대상으로 하였으며, 방동제와 물의 희석비는 각 종류별 3개 수준으로 하였는데, 방동제와 물의 희석비가 1:3의 경우 $-4.9{\sim}-6.3^{\circ}C$, 1:5의 경우 $-3.3{\sim}-4.2^{\circ}C$, 1:7의 경우 $-2.1{\sim}-3.3^{\circ}C$의 범위를 나타내었다.

  • PDF

증기양생콘크리트의 최고양생온도변화가 콘크리트의 동결융해저항성에 미치는 영향 (An experimental Study for the Maximun Curing Temperature Effect on the Freezing and Thawing of Steam Curing Concrete)

  • 윤석;최세규;김동신;유승룡;김생빈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.170-176
    • /
    • 1997
  • The published works on steam curing effect have been generally concentrated on the subject, "compressive strength". However a practical test for durable steam curing concrete products has not been performed in domestic. In this study, the maximum temperature of steam is considered as a major variable to investigate the freezing and thawing resistance of the steam curing concrete. All of the specimen were cured for 24 hours which included presteaming 4 hour. Finally we found that the most effective curing condition is the case of one-day and 14-day specimens after the 24 hours steam curing at $74^{\cire}C$ degree curing temperature. It is also found that the durability of one-day samples are much weaker than those of 14-day samples. Consequently, we can conclude that the samples that produced immediately after a steam curing are more possible to deteriorate from the freezing and thawing environment.vironment.

  • PDF

Conditions for the disinfectant efficacy test under subzero temperatures

  • Chae, Won-Seok;Jeong, Wooseog;Lee, Hu-Jang
    • 대한수의학회지
    • /
    • 제59권1호
    • /
    • pp.43-45
    • /
    • 2019
  • To establish appropriate conditions for a disinfectant efficacy test at subzero temperatures, this study examined mixtures of frozen foot-and-mouth disease virus or avian influenza virus solutions and disinfectant diluents at $-5^{\circ}C$ and monitored temperature and freezing status of an anti-freezing diluent (AFD, 15% ethanol + 30% propylene glycol + 55% distilled water) over time at various subzero temperatures. Viral solutions and disinfectant diluents froze before the mixtures reached $-5^{\circ}C$, whereas the AFD was not frozen at $-30^{\circ}C$. The times taken for the AFD to reach -10, -20, -30, and $-40^{\circ}C$ from room temperature were 36, 39, 45, and 48 min, respectively.

실내동결시스템을 이용한 노상토의 동상 특성 (The Frost Heaving Characteristics of Subgrade Soils Using Laboratory Freezing System)

  • 신은철;류병현;박정준
    • 한국도로학회논문집
    • /
    • 제12권2호
    • /
    • pp.71-79
    • /
    • 2010
  • 겨울에는 시베리아기단의 영향으로 한랭 건조한 대륙성 고기압의 영향을 받아 춥고 건조하여 1월 평균기온이 $-6{\sim}-7^{\circ}C$의 영하의 온도로 낮아져 지반동결시 수분이동으로 동상현상이 발생하여 도로의 불균형 동결팽창을 초래하며, 결국 포장체를 파손시킨다. 동상발생시 토립자는 모관력에 의해 지하수를 흡수하여 아이스렌즈를 형성하며, 이 모관 흡수력은 토립자의 크기에 영향을 받는다. 도로는 다양한 재료와 단면으로 구성된 구조물이기 때문에 환경성과 재료 물성뿐만 아니라 포장체 각 층의 구조적 적정성 또는 지지력을 파악하는 것이 무엇보다 중요하다. 현재 기존 동상방지층 설계법에 따르면, 동상방지층은 포장체의 구조적 적정성과는 무관하게 온도 조건에 따른 동결깊이에 따라 일률적으로 결정되고 있다. 이러한 동결깊이를 포장구조설계에 적용함으로써 포장의 과다설계 우려가 있다. 따라서 본 논문에서는 도로 동상방지층의 효용성 검증 및 설치기준 확립을 위해 실내동결시스템을 활용하여 도로 노상토의 동상 특성에 대한 민감성을 판별, 도로건설 현장 노상토에 대한 역학적 특성과 실내 동결 시험을 수행하였으며, 외부 동결온도의 지속 조건에 대한 시료의 온도변화, 동상팽창압, 동상팽창량, 부동수분 등의 결과값을 통하여 동결 과정에 따른 지반공학적 특성을 평가하였다.