• Title/Summary/Keyword: Free- fall

Search Result 230, Processing Time 0.03 seconds

The Lift-off and Fall-down Characteristics due to Particles in Coaxial Electrode (동축원통 전극내 금속이물의 부상 및 하강전압 특성)

  • Lee, Jae-Gul;Lee, Kon;Jin, Sang-Bum;Park, Hyun-Su;Cho, Kook-Hee;Kim, Kyong-Hwa;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1711-1713
    • /
    • 1998
  • This paper describes the insulation characteristics of GIS by the free conducting particles under alternating voltage. The particles of the GIS can cause decrease in breakdown voltages. Various materials and sizes of free conducting particles were used to study the lift-off and fall-down characteristics. The measured lift-off voltage for copper particle agreed with the calculated one.

  • PDF

Feasibility study of usage of air pressure cylinder on slamming experiment (슬래밍 현상 실험에 공기압 실린더의 사용 가능성에 관한 연구)

  • Jung, D.J.;Park, J.S.;Kwon, S.H.;Pack, S.W.;Jung, J.Y.
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.229-233
    • /
    • 2002
  • This paper presents the results of slamming experiment using air pressure cylinder to increase the repeatability of the experiment. When it comes to the slamming experiment, the traditional way of doing it has been the free fall experiment. By adopting air pressure cylinder almost equal peak pressures were obtained with that of free fall experiment. Therefore, the air pressure cylinder can be an alternative tool in slamming experiment.

  • PDF

A Piston Type Free-fall Corer(KORDI-FFC) (피스톤식 자유낙하 주상시료 채취기)

  • 지상범;어영상
    • 한국해양학회지
    • /
    • v.30 no.4
    • /
    • pp.365-370
    • /
    • 1995
  • A new piston-type Free-fall corer (FFC) was developed for the sampling of core sediments in aquatic environments. The corer, named "KORDI-FFC", is the modified sampler of the existing FFX with an open barrel gravity corer. It was rested successfully on the muddy bottom in the Chinhae Bay and on the sandy bottom (Mz=3$\phi$) in nearshore areas around the Cheju Island. Several merits found in the unstrument are; $\circled1$ operation on a small vessel without winch and cable, $\circled2$ low cost of construction, $\circled3$ little disturbance of surface sediments during the sampling, $\circled4$ short round-trip time of sampling, and $\circled5$ simultaneous performance of other research works during the lowering of FFC.

  • PDF

Comparison of the Free-Fall Impact Force Applied to a Multicopter PAV According to External Airbag Folding Method (외부 에어백 폴딩 방식에 따른 자유 낙하 충돌 시 멀티콥터형 개인용 항공기에 가해지는 충격력 비교)

  • Jang, Yoon Ho;Kim, Jeong
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.1
    • /
    • pp.28-39
    • /
    • 2022
  • With the development of small multicopter PAV (Personal Air Vehicle), it is necessary to develop safety-related devices for manned rotorcraft. In this study, we assumed that an external airbag can be installed in a small multicopter PAV, and using LS-DYNA's Airbag Folding Application, we performed a free-fall collision analysis by modeling the airbag shapes consisting or Roll, Zigzag, and Sigma. There was no significant difference in the final airbag deployment time of the three models. However, when it collides with the ground during deployment, the Sigma fold type external airbag had the fastest deployment speed, applying the most impact force to the PAV, while the Roll fold type external airbag applied the smallest impact force to the PAV.

The Effect on the Hip Muscle Activation of the Fall Direction and Knee Position During a Fall

  • Lee, Kwang Jun;Lim, Kitaek;Choi, Woochol Joseph
    • Physical Therapy Korea
    • /
    • v.28 no.1
    • /
    • pp.84-91
    • /
    • 2021
  • Background: A hip fracture may occur spontaneously prior to the hip impact, due to the muscle pulling force exceeding the strength of the femur. Objects: We conducted falling experiments with humans to measure the activity of the hip muscles, and to examine how this was affected by the fall type. Methods: Eighteen individuals fell and landed sideways on a mat, by mimicking video-captured real-life older adults' falls. Falling trials were acquired with three fall directions: forward, backward, or sideways, and with three knee positions at the time of hip impact, where the landing side knee was free of constraint, or contacted the mat or the contralateral knee. During falls, the activities of the iliopsoas (Ilio), gluteus medius (Gmed), gluteus maximus (Gmax) and adductor longus (ADDL) muscles were recorded. Outcome variables included the time to onset, activity at the time of hip impact, and timing of the peak activity with respect to the time of hip impact. Results: For Ilio, Gmed, Gmax, and ADDL, respectively, EMG onset averaged 292, 304, 350, and 248 ms after fall initiation. Timing of the peak activity averaged 106, 96, 84, and 180 ms prior to the hip impact, and activity at the time of hip impact averaged 72.3, 45.2, 64.3, and 63.4% of the peak activity. Furthermore, the outcome variables were associated with fall direction and/or knee position in all but the iliopsoas muscle. Conclusion: Our results provide insights on the hip muscle activation during a fall, which may help to understand the potential injury mechanism of the spontaneous hip fracture.

Influence of the Silver Line Dance Applied to the elderly on the Balance during Walking (라인댄스 운동이 여성노인들의 보행 균형성 요인에 미치는 영향)

  • Choi, Youn-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.109-118
    • /
    • 2013
  • The purpose of this study was to determine the effects of line dance programme on the balance ability during walking to reveal the exercise intervention for fall prevention. A 12-week line dance programme was applied to 18 elderly females who aged more than 65 years in the community. Balance ability during walking was evaluated by the range of center of pressure(cop), the velocity of cop, and free torque that calculated on the basis of ground reaction force data. The range and velocity of cop in the anterio-posterior were significantly reduced after performing(p<.01, p<.05, respectively), but change in those of cop in the medio-lateral and free torque were not found. It was demonstrates that 12-week line dance programme allows more effective in anterio-posterior stability of walking. It was suggested that the effect of fall prevention exercise should be studied more associate with fall frequency as future study.

Resistance of Cementitious Binders against a Fall in the pH at Corrosion Initiation

  • Song, Ha-Won;Jung, Min-Sun;Ann, Ki Yong;Lee, Chang-Hong
    • Corrosion Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.110-115
    • /
    • 2009
  • At the onset of corrosion of steel in concrete, hydrogen ions usually evolve in the process of electrochemical reaction, thereby decreasing the pH of the pore solution, which can be buffered by cement hydration products, as being representatively illustrated by calcium hydroxide. Hence, a fall in the pH is dependent on properties of cement hydration (i.e. hydration products and degree of hydration). The present study tested acid neutralization capacity (ANC) of cementitious binders of OPC(Ordinary Portland Cement), 30% PFA(Pulverized Fuel Ash), 60% GGBS(Ground Granulated Blast Furnace Slag), 10% SF(Silica Fume) to quantify the resistance of cement matrix to a pH fall. Cement pastes were cast at 0.4 of a free W/C ratio with 1.5% chlorides by weight of binder in cast. Powder samples obtained crushed and ground specimen after 200 days of curing were diluted in still water combined with different levels of 1M nitric acid solution, ranging from 0.5 to 20 mol/kg. Then, the pH of diluted solution was monitored until any further change in the pH did not take place. It was seen that the pH of the diluted solution gradually decreased as the molar amount of nitric acid increased. At some particular values of the pH, however, a decrease in the pH was marginal, which can be expressed in the peak resistances to a pH fall in the ANC curve. The peaks occurred at the variations in the pH, depending on binder type, but commonly at about 12.5 in the pH, indicate a resistance of precipitated calcium hydroxide. The measurement of water soluble chloride at the end of test showed that the amount of free chloride was significantly increased at the pH corresponding to the peaks in the ANC curve, which may reflect the adsorption of hydration products to chlorides.

Feature Extraction and Evaluation for Classification Models of Injurious Falls Based on Surface Electromyography

  • Lim, Kitaek;Choi, Woochol Joseph
    • Physical Therapy Korea
    • /
    • v.28 no.2
    • /
    • pp.123-131
    • /
    • 2021
  • Background: Only 2% of falls in older adults result in serious injuries (i.e., hip fracture). Therefore, it is important to differentiate injurious versus non-injurious falls, which is critical to develop effective interventions for injury prevention. Objects: The purpose of this study was to a. extract the best features of surface electromyography (sEMG) for classification of injurious falls, and b. find a best model provided by data mining techniques using the extracted features. Methods: Twenty young adults self-initiated falls and landed sideways. Falling trials were consisted of three initial fall directions (forward, sideways, or backward) and three knee positions at the time of hip impact (the impacting-side knee contacted the other knee ("knee together") or the mat ("knee on mat"), or neither the other knee nor the mat was contacted by the impacting-side knee ("free knee"). Falls involved "backward initial fall direction" or "free knee" were defined as "injurious falls" as suggested from previous studies. Nine features were extracted from sEMG signals of four hip muscles during a fall, including integral of absolute value (IAV), Wilson amplitude (WAMP), zero crossing (ZC), number of turns (NT), mean of amplitude (MA), root mean square (RMS), average amplitude change (AAC), difference absolute standard deviation value (DASDV). The decision tree and support vector machine (SVM) were used to classify the injurious falls. Results: For the initial fall direction, accuracy of the best model (SVM with a DASDV) was 48%. For the knee position, accuracy of the best model (SVM with an AAC) was 49%. Furthermore, there was no model that has sensitivity and specificity of 80% or greater. Conclusion: Our results suggest that the classification model built upon the sEMG features of the four hip muscles are not effective to classify injurious falls. Future studies should consider other data mining techniques with different muscles.

A Study on the Correlation with the Degree of Compaction and the Penetration Depth Using the Portable Penetration Meter at Field Test (휴대용 다짐도 측정기의 현장실험을 통한 다짐도와 관입깊이 상관성 연구)

  • Park, Geoun Hyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.11
    • /
    • pp.5-14
    • /
    • 2018
  • Worldwide, soil compaction work is one of the most important activities that are carried out on civil engineering works sites. Compaction work, particularly in the area of road construction, is considered to be important, as poor compaction work is closely related with poor construction even after a construction is complete. Currently, the plate bearing test or the sand cone method relative to the unit weight of soil test are commonly used to measure the degree of compaction, but as these require a great deal of time, equipment and manpower, it is difficult to secure economic efficiency. The method that is used to measure the degree of compaction according to the penetration depth achieved by free fall objects through gravity is the Free-Fall Penetration Test (FFPT), which uses a so-called "portable compaction measuring meter (PCMM)." In this study, the degree of compaction was measured and a penetration depth graph was developed after the field test using the portable compaction measuring meter. The coefficient of determination was 0.963 at a drop height of 10 cm, showing the highest level of accuracy. Both horizontal axis and longitudinal axis were developed in a decimal form of graph, and the range of allowable error was ${\pm}1.28mm$ based on the penetration depth. The portable compaction measuring meter makes it possible to measure the degree of compaction simply, quickly and accurately in the field, which will ensure economic efficiency and facilitate the process management.

Examination of Correction Factor for Manganese Nodule Abundance Using the Free Fall Grab and Box Corer (자유낙하식 시료채취기(Free Fall Grab)와 상자형 퇴적물시료 채취기(Box Corer)를 이용한 망간단괴 부존밀도 보정상수에 관한 고찰)

  • Lee, Gun-Chang;Kim, Jong-Uk;Chi, Sang-Bum;Ko, Young-Tak;Ham, Dong-Jin
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.3
    • /
    • pp.280-285
    • /
    • 2008
  • Manganese nodule abundance estimated based on operation of a Free Fall Grab(FFG) needs to be corrected to make up for its incomplete recovery of nodule, because FFGs can not recover all the nodules distributed on seabed. The correction factor for nodule abundance was proposed as 1.29 and 1.13 in 1994 and 2002, respectively, mainly based on the analyses of seabed images. In this study we collected manganese nodules using both FFG and Box Corer(BC) at same stations to examine the accuracy of the previous correction factors. It was found that the nodule recovery of the BC was 1.4 times greater than that of the FFG at the same sampling station, suggesting the necessity of re-evaluation of the previously proposed correction factor for FFG. More extensive sampling and improvement of image analysis method are required to improve the precision of nodule abundance correction factor for FFG.