영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석 (The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area)

  • 김성규;손상혁
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

X선촬영실 내에서의 공간산란선량 변동에 관한 연구 (A Study on the Behavior of the Free Space Scatter dose in X-ray Diagnostic Room)

  • 오현주;김성수;김영일;임한영;김흥태;이후민;김학성;이상석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제17권2호
    • /
    • pp.21-27
    • /
    • 1994
  • In this pauper, when the X-ray exposure condition is 70, 90, 110 kV, 10 mAs, FFD 180 cm, FSO $10{\times}10$, $35{\times}35\;cm$, toward the $36{\times}36{\times}15\;cm$ acryl phantom, the free space scatter dose rate at the 15th points in X-ray diagnostic room was measured by electrometer and 1800 co ionization chamber. Therefore, the free space scatter dose distribution profile was drown, and then, the free space scatter dose contribution percentage was Investigated. The obtained results are summarized as following. 1. The X-ray tube leakage dose rate of the experiment generator at the 1 m from focus was measured maximum 85 mR/hr, minimum 20 mR/hr, therefore, this values was appeared below the KS rules, 2. The free space scatter dose become to larger at the primary X-ray beam around area, and lower at the back ward X-ray tube. The maximum values were 3,812 mR/hr at the front Lt 1 m $45^{\circ}$ point, minimum 117 mR/hr at the back ward 1 m $180^{\circ}C$ point. 3. As the more tube voltage and field size increase, the more free space scatter dose contribution percentage become to increase, as to 90 kV from 70 kV, increase to 12 %, to 110 kV from 90 kV, increase to 18 %, and then, become to 11 % at the $10{\times}10\;cm$ and 87 % at the $35{\times}35\;cm$. 4. The 89 % of the total producted scatter ray occured from acryl phantom, at the X-ray tube housing 6 %, at the front side back wall 5 %. 5. The free space scatter dose contribution percentage at the one point build up 80 % from the phanton direction, 14 % from the X-ray tube and collimator direction, 2.2 % from the front wall, 1.8 % from the side wall, 1.7 % the back wall.

  • PDF

전산화 단층촬영실의 산란선 측정에 대한 연구 (A Study on measurement of scattery ray of Computed Tomography)

  • 조평곤;이준협;김윤식;이창엽
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권2호
    • /
    • pp.37-42
    • /
    • 2003
  • 목 적 : 전산화 단층촬영장치는 방사선을 이용한 질병의 진단에 중추적인 역할을 하는 장비이다. 시대의 흐름과 과학기술의 발달로 전산화 단층촬영장치도 그 발전을 거듭해왔고 앞으로도 전산화 단층촬영장치를 이용한 검사는 더욱더 증가하리라 생각된다. 검사의 증가와 함께 산란선에 노출될 기회가 많아질 것이라는 생각 또한 사실이다. 이에 전산화 단층촬영실의 제어실내 환자 보기창 앞과 환자 및 보호자들이 출입하는 출입문 외측 그리고 환자 검사 시 촬영실내에서의 산란선 발생률을 측정하였고 산란선의 피폭을 가장 최소화 할 수 있는 방법을 알아보고자 하였다. 대상 및 방법 : 2001년 11월부터 서울소재 13개 종합병원 및 대학병원에 설치 운용중인 전산화 단층촬영장치 25를 대상으로 하였다. 촬영조건은 피폭선량 측정시 제조업소에서 권고 하고있는 촬영조건을 사용하였고, 이때 피사체는 피폭선량 측정용 DALI CT 피폭선량 측정용 두부용 팬톰(${\phi}16\;cm$ Plexglas)과 복부용 팬톰(${\phi}32\;cm$ Plexglas)을 사용하였다. 산란선의 측정은 환경방사선 측정용 Survey Meter인 Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion chamber, S/N 21740에 Reader(Radiation Monitor Controller model 2026)과 G-M Survey를 이용하였다. 산란선의 측정위치는 전산화 단층촬영실에서 방사선 작업종사자가 주로 활동하는 제어실내 환자 보기창 앞과 환자 및 보호자들이 출입하는 출입문 외측 그리고 피사체 스캔시 등선량중심점(isocenter)으로부터 100 cm되는 지점에서 측정하였다. 결 과 : 각 병원에서 설치 운용중인 전산화 단층촬영실내 작업환경은 해당병원의 상황에 따라 많은 차이를 보이고 있었고 산란선의 발생유무는 다음과 같았다. 1) 전산화 단층촬영장치의 등선량중심점(isocenter)에서부터 제어실내 환자 보기창 사이의 거리는 평균 377 cm이였고 이때 산란선은 거의 검출되지 않은 곳에서부터 약 100 mR/week까지 다양한 분포를 보였으나 주당 허용선량인 $2.58{\times}10^{-5}\;C/kg$(100 mR/week)이내의 조건을 만족하고 있었다. 2) 전산화 단층촬영장치의 등선량중심점(isocenter)에서부터 환자 및 보호자가 출입하는 출입문 외측까지의 거리는 평균 439cm이었고, 이때 산란선은 거의 검출되지 않은 곳부터 다양한 분포를 보였으나 대부분의 병원에서 주당허용선량인 $2.58{\times}10^{-6}\;C/kg$(10 mR/week)이내의 조건을 만족하고 있었다. 3) 피사체를 스캔할 때 등선량중심점(isocenter)에서부터 100 cm되는 곳에서의 산란선량은 장비에 따라 많은 차이가 있었다. 결 론 : 진단용 방사선발생장치에서 전산화 단층촬영장치의 이용은 나날이 증가하고 있고 다른 일반 X-선 촬영과 비교했을 때 진단영역이 매우 높지만 방사선으로 인한 피폭과 산란선에 노출될 가능성이 매우 높다. 전산화 단층촬영실에서 산란선으로부터 조금이라도 자유로워지기 위해서는 설계단계에서부터 충분한 공간 확보가 우선되어야하고 모든 검사에서 방사선사는 최소의 선량으로 최상의 영상을 제공할 수 있는 다양한 기술개발에 더욱 노력을 아끼지 말아야 할 것으로 생각된다.

  • PDF