• 제목/요약/키워드: Free Space Estimation

검색결과 51건 처리시간 0.025초

Thruster fault diagnosis method based on Gaussian particle filter for autonomous underwater vehicles

  • Sun, Yu-shan;Ran, Xiang-rui;Li, Yue-ming;Zhang, Guo-cheng;Zhang, Ying-hao
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권3호
    • /
    • pp.243-251
    • /
    • 2016
  • Autonomous Underwater Vehicles (AUVs) generally work in complex marine environments. Any fault in AUVs may cause significant losses. Thus, system reliability and automatic fault diagnosis are important. To address the actuator failure of AUVs, a fault diagnosis method based on the Gaussian particle filter is proposed in this study. Six free-space motion equation mathematical models are established in accordance with the actuator configuration of AUVs. The value of the control (moment) loss parameter is adopted on the basis of these models to represent underwater vehicle malfunction, and an actuator failure model is established. An improved Gaussian particle filtering algorithm is proposed and is used to estimate the AUV failure model and motion state. Bayes algorithm is employed to perform robot fault detection. The sliding window method is adopted for fault magnitude estimation. The feasibility and validity of the proposed method are verified through simulation experiments and experimental data.

Modelling and FEA-simulation of the anisotropic damping of thermoplastic composites

  • Klaerner, Matthias;Wuehrl, Mario;Kroll, Lothar;Marburg, Steffen
    • Advances in aircraft and spacecraft science
    • /
    • 제3권3호
    • /
    • pp.331-349
    • /
    • 2016
  • Stiff and light fibre reinforced composites as used in air- and space-craft applications tend to high sound emission. Therefore, the damping properties are essential for the entire structural and acoustic engineering. Viscous damping is an established and reasonably linear model of the dissipation behaviour. Commonly, it is assumed to be isotropic and constant over all modes. For anisotropic materials it depends on the fibre orientation as well as the elastic and thermal material properties. To portray the orthogonal anisotropic behaviour, a model for unidirectional fibre reinforced plastics (frp) has been developed based on the classical laminate theory by ADAMS and BACON starting in 1973. Their approach includes three damping coefficients - for longitudinal damping in fibre direction, damping transversal to the fibres and shear based dissipation. The damping of a laminate is then accumulated layer wise including the anisotropic stiffness. So far, the model has been applied mainly to thermoset matrix materials. In this study, an experimental parameter estimation for different thermoplastic frp with angle ply and cross ply layups was carried out by measuring free vibrations of cantilever beams. The results show potential and limits of the ADAMS/BACON damping criterion. In addition, a possibility of modelling the anisotropic damping is shown. The implementation in standard FEA software is used to study the influence of boundary conditions on the damping properties and numerically estimate the radiated sound power of thin-walled frp parts.

지상사진(地上寫眞)에 의한 삼차원변형측량(三次元變形測量)의 신뢰도(信賴度) 분석(分析)(기일(其一)) (Reliability Analysis of the Three-Dimensional Deformation Measurement by Terrestrial Photogrammetry)

  • 유복모;유환희;김인섭
    • 대한토목학회논문집
    • /
    • 제7권4호
    • /
    • pp.139-146
    • /
    • 1987
  • 지상사진측량(地上寫眞測量)에 의한 3차원변형해석(次元變形測量)은 표정점(標定點)에 대한 3차원좌표(次元變座標)를 계산하고 이들 좌표로부터 변위(變位)를 구하므로써 변형해석(變形測量)을 하게 된다. 지상사진측량(地上寫眞測量)에 의한 변형해석(變形測量)은 3차원좌표(次元變座標) 획득과 변위점검출(變位點檢出) 및 변형량추정(變形量推定)으로 크게 나눌 수 있다. 본(本) 연구(硏究)에서는 처음단계로 번들조정법에 의한 좌표계산에서 지상기준점수(地上基準點數)와 사진수(寫眞數)의 증가에 따른 외부표정요소(外部標定要素)의 분산(分散)-공분산행렬(共分散行列)변화를 분석하였다. 그리고 지상기준점(地上基準點)의 정확도(正確度)를 향상시키기 위한 제약조건을 주기위해 번들조정법에 자유강조정(自由鋼調整)개념을 도입하였다. 이상의 결과분석으로부터 경제성과 시간절약의 측면을 고려할때 지상기준점수(地上基準點數)는 6점(點), 사진수(寫眞數)는 3개가 적합함을 알 수 있다. 또한 번들조정에 자유강조정(自由鋼調整)개념을 적용한 경우 공간거리의 제약조건을 외곽에 분포시키는 것이 바람직함을 알 수 있었다.

  • PDF

운전재활프로그램이 노인의 인지기능에 미치는 효과 (The Effects of Driving Rehabilitation Program on Cognitive Function in Elderly)

  • 이정숙;김보라;하재영;박지민;조예슬;하진리;홍우선;김성원
    • 대한통합의학회지
    • /
    • 제2권4호
    • /
    • pp.91-100
    • /
    • 2014
  • Purpose : The purpose of this experiment is to find out the effectiveness which exert influence on cognitive skills by using the Driver Rehabilitation program for senior citizens who are over 65 years old and live in Busan. Method : From July first, 2014 to August 28th, 2014, we researched the 60 elderly people who are over 65 and go to community relief center which is in Busan. - 30 are experimental group and the other is control group. In the experimental group, we used Nintendo wii's driving simulation program and RC Car driving program in the model road. For estimation, we used MVPT-3(Motor-Free Visual Perception Test-3), Trail Making Test - 1, Trail making Test - 2 and LOTCA(Loewenstein Occupational Therapy Cognitive Assessment). Result : Nintendo wii's driving simulation program and RC Car driving program in model road results efficient visual perception ability. This programs results effectively in visual perception ability and space perception ability. This programs results effectively in motor apraxia ability. This programs results effectively in control ability for visual perception. This programs results effectively in thinking operation. Conclusion : Nintendo Wii's driving simulation program and RC Car driving program in model road positively influence improving for visual perceptual ability and cognitive function of elderly people. Also it is considered as being more efficient for improving visual perceptual ability and cognitive function to implement basic rehabilitation training with driving rehabilitation program than basic training itself.

13.56 MHz 무선 에너지 전송 시스템의 효율적인 전자파 장해(EMI) 예측 및 분석 방법 (A Method of Prediction and Analysis of Electromagnetic Interference (EMI) in Wireless Power Transfer System Operating at 13.56 MHz)

  • 심현진;박종민;남상욱
    • 한국전자파학회논문지
    • /
    • 제24권9호
    • /
    • pp.873-882
    • /
    • 2013
  • 13.56 MHz 무선 에너지 전송 시스템의 효율적인 전자파 장해(EMI) 측정 및 분석 방법을 제안한다. 두 루프 안테나가 자유 공간과 PEC면 위에 있는 두 가지 경우에 대하여 영상법과 쌍대성을 이용하여 자계 결합 시스템의 등가회로 모델링 분석을 통하여 각 루프에 흐르는 전류 및 발생하는 전자장을 수식적으로 표현한다. 여기서 완전 도체(Perfect Electric Conductor: PEC)는 완전 도체의 무한한 평면의 형태를 가지며, 이후에는 PEC면이라고 지칭한다. 원점에서 부터 관측 지점까지의 거리보다 충분히 가까운 지점에서의 최대 전자장의 크기를 이용하여 원점에서 충분히 떨어진 지점의 최대 전자장의 크기를 이론적으로 유추할 수 있다. 근거리에서의 자기장의 크기로 이론적으로 유추한 10 m 떨어진 위치에서의 최대 전자장의 크기와 상용 수치 해석 툴을 이용하여 구한 10 m 떨어진 위치의 최대 전자장의 크기를 비교, 분석하였다. 또한, 이론적으로 구한 최대 자기장의 크기를 바탕으로 방사성 장해 허용 기준을 만족하는 최대 허용 전력의 크기도 쉽게 구할 수 있다.

하이브리드형 압전 변압기의 고주파 승압 초퍼를 이용한 적응제어기법 유도전동기 속도 센서리스 벡터제어에 관한 연구 (A Study on the Speed Sensorless Vector Control for Induction Motor Adaptive Control Method using a High Frequency Boost Chopper of Hybrid Type Piezoelectric Transformer)

  • 황락훈;나승권;김영욱;최성식
    • 한국항행학회논문지
    • /
    • 제17권3호
    • /
    • pp.332-345
    • /
    • 2013
  • 본 논문에서는 최근, 압전 변압기 기술의 급속한 발전을 이용하므로 자계의 잡음이 없고, 크기가 소형화되며 고효율과 고 전력 밀도, 누설자속이 없어 노이즈 발생이 없고, 공진주파수만을 이용하므로 출력파형이 정현파에 가까워 고조파 잡음이 없는 점을 이용하여 전기적인 등가회로를 적용하여 DC-DC 컨버터를 구현 하였다. 유도전동기 회전자 속도 개념에 자속 기준 모델 적용 시스템(FMRAS)을 적용하였다. 유도전동기의 벡터제어는 회전자 속도 정의의 추정값을 이용하여 실행 할 수 있고, 부가된 변화되는 모델로 회전자 목표값 계산을 수행 할 수 있다. 이 시스템은 PWM 공간 전압기법과 DC-DC 컨버터를 이용하여 벡터전류제어와 속도제어를 위한 PI제어기로 구성되어 있다. 제어를 위한 실행과 높은 속도계산을 디지털 신호 원칩 마이크로프로세서에 의해 수행 되었고, 시뮬레이션과 실험을 통해서 다양한 제어 방법의 타당성을 제시 하였다.

저궤도 위성의 통과시간에서 관제 시스템의 수신 데이터 패킷 성능 예측 (Performance Estimation of Receiving Data Parket of TT&C System on the Pass Time of LEO Satellite)

  • 장대익;김대영
    • 한국통신학회논문지
    • /
    • 제24권8A호
    • /
    • pp.1149-1155
    • /
    • 1999
  • 저궤도위성 시스템은 지구 및 과학 관측분야(지도제작, 해양생태감시, 우주환경 관측, 기상관측, 대기관측 등)와 군사분야(군사통신, 첩보, 적군정찰 등)에서 사용되었으며, 최근에는 상업적 이용을 위해 GMPCS를 위한 이동위성통신 분야에서 개발이 진행되고 있다. 우리나라에서는 1999년 10월 발사를 목표로 다목적 실용위성 1호가 개발되고 있다. 본 논문에서는 저궤도위성 관제시스템을 위한 위성링크를 설계하고 위성의 움직임에 따른 위성의 통과시간과 지구국의 양각 관계를 계산한다. 그리고 수신데이터의 패킷오율을 확률이론에 의해 유도하고, RT모드와 PB모드 그리고 RT+RNG모드에 대한 패킷오율을 위성과 통과시간에 따라 예측한다. 패킷오율 계산결과는 RT모드, PB모드, RT+RNG모드의 순으로 좋으며 EFP의 평균도 각각 99.999999%, 99.995945%로 계산되었다. 따라서 원격측정 데이터의 전송순서는 위성의 통과시간에 따른 PER 순서로 즉, RT, PB, RT+RNG순으로 결정한다.

  • PDF

유비쿼터스 센서 네트워크 기반 지능형 교량 시스템 개발 (Development of Ubiquitous Sensor Network Intelligent Bridge System)

  • 조병완;박정훈;윤광원;김헌
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.120-130
    • /
    • 2012
  • 최근 장대 교량 및 복잡한 교량의 형상이 자주 건설됨에 따라, 교량의 안전도 및 건전성 평가에 많은 관심이 집중되고 있다. 장대교량의 경우 다양한 종류의 계측기 들이 설치되어, 측정된 센싱(Sensing)자료를 신호처리를 통해 케이블을 이용하여 장거리 전송하거나, Smart Health 모니터링 개념으로 교량 현장에서 게이트웨이(Gateway)를 통해 외부 무선통신망에 연결하여 정보를 전송하는 최신 무선통신 기술을 적용하고 있다. 하지만, 전 세계적으로 발생한 교량 관련 안전사고의 경우 위험 또는 사고인지에 따른 실시간 예방적, 지능적 조치가 미흡하여 대형사로를 유발한 것으로 보고되고 있다. 이런 문제점을 해결하고자 본 논문에서는 첨단 무선통신인 RFID(Radio Frequency Identification)/USN (Ubiquitous Sensor Network)기술의 기본 개념인 "Communication Among things" 사물 간 통신 개념을 교량 계측모니터링에 적용하여, 교량에 탑재된 다양한 계측 센서 노드로부터 내구성/안전성에 관련된 위험신호를 추출하여 긴박한 안전사고 등이 인지된 경우 사고예방개념에서 사물 간 통신개념으로, 교량의 센서노드가 바로 교량 인근의 교통신호등에 RF 무선 전파를 송신하여 교량의 교통을 차단하며, 대형 사고를 예방할 수 있는 USN기반의 지능형 교량 시스템을 구축을 위한 센서노드모듈을 설계 하였으며, TinyOS 기반 미들웨어 설계와 센서 자유공간 송수신거리 테스트를 실시하여 센서의 성능을 검증 하였다.

지대공미사일 요격 성능 분석 시뮬레이터 개발 (Development of Simulator for Analyzing Intercept Performance of Surface-to-air Missile)

  • 김기환;서윤호
    • 한국시뮬레이션학회논문지
    • /
    • 제19권1호
    • /
    • pp.63-71
    • /
    • 2010
  • 현대전에서는 정보전을 기반으로 미사일, 유도무기 등의 사정거리와 정밀도가 향상됨에 따라 지대공미사일(SAM : Surface to Air Missile)의 요격성능의 중요성이 부각되고 있다. 위협적인 공중 공격을 예측 하고 방어하기 위해 최선의 방법으로 지대공 레이더와 유도미사일을 이용한 공중방어시스템 구축이 필요하다. 지대공미사일 개발 과정에서 Modeling and Simulation (M&S)을 이용하는 것은 시간적, 공간적 제한을 극복할 수 있고 시행착오를 줄임으로 비용을 절감할 수 있는 이점이 있다. M&S는 최신 무기체계 설계 및 교육/훈련 분야에 많이 적용되고 있다. 본 연구는 지대공미사일의 요격 성능 평가를 위한 시뮬레이터를 개발하는 것에 목적이 있다. 본 연구에서는 다양한 사양의 지대공미사일 요격 성능을 고려할 수 있는 지대공미사일 요격 성능 분석 시뮬레이터의 아키텍처를 제시하고 개발하였다. 개발된 지대공미사일 요격 성능 분석 시뮬레이터는 C++와 Direct3D를 기반으로 개발되었으며, Direct3D를 이용한 3D 가시화를 통해 사용자에게 애니메이션 창에 시각적으로 시뮬레이션의 진행 경과를 보여줄 수 있도록 개발되었다. 사용자의 교전모델 설계 운영 정보는 입력창을 통해 입력되며, 이 정보는 객체 관리자, 운영 관리자, 통합 관리자로 구성된 시뮬레이션 엔진에서 자동으로 지대공미사일을 모델링 및 시뮬레이션 하여 빠른 시간 안에 시뮬레이터 사용자에게 피드백을 제공한다.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF