• Title/Summary/Keyword: Free End

Search Result 1,198, Processing Time 0.022 seconds

Effects on the Escapement of Juvenile Bastard Halibut Paralichthys olivaceus of Actively Stimulating Devices Inside a Model Cod End

  • Kim, Yong-Hae
    • Fisheries and Aquatic Sciences
    • /
    • v.14 no.1
    • /
    • pp.62-69
    • /
    • 2011
  • The effects of actively stimulating devices (ASD) on juvenile flatfish escape were studied to increase escape rates from the cod end by encouraging fish to approach the net wall. Two kinds of ASD were designed: a fluttering net panel, i.e., a free-end flag-like net panel, and a double conical rope array. Escape responses of juvenile bastard halibut were observed in a circulating water channel using two model cod ends, one made with diamond-shaped 43-mm-mesh-size polyethylene (PE) as a high-contrast cod end and the other with polyamid (PA) mono-ply as a low-contrast cod end. Retention rate was significantly lower with the double conical rope-array ASD in the PE cod end than with conventional PE cod ends only or the fluttering net-panel ASD inside the PE cod end. Mean retention rate with the low-contrast PA cod end was also significantly lower than that with the high-contrast PE conventional cod end. Therefore, active fluttering devices using a double conical rope array together with less visible low-contrast netting in the cod end could help to reduce the bycatch of juvenile flatfish by weakening their optomotor response and actively driving fish to the side net panel.

Is Robot-Assisted Surgery Really Scarless Surgery? Immediate Reconstruction with a Jejunal Free Flap for Esophageal Rupture after Robot-Assisted Thyroidectomy

  • Park, Seong Hoon;Kim, Joo Hyun;Lee, Jun Won;Jeong, Hii Sun;Lee, Dong Jin;Kim, Byung Chun;Suh, In Suck
    • Archives of Plastic Surgery
    • /
    • v.44 no.6
    • /
    • pp.550-553
    • /
    • 2017
  • Esophageal perforation is a rare but potentially fatal complication of robot-assisted thyroidectomy (RAT). Herein, we report the long-term outcome of an esophageal reconstruction with a jejunal free flap for esophageal rupture after RAT. A 33-year-old woman developed subcutaneous emphysema and hoarseness on postoperative day1 following RAT. Esophageal rupture was diagnosed by computed tomography and endoscopy, and immediate surgical exploration confirmed esophageal rupture, as well as recurrent laryngeal nerve injury. We performed a jejunal free flap repair of the 8-cm defect in the esophagus. End-to-side microvascular anastomoses were created between the right external carotid artery and the jejunal branches of the superior mesenteric artery, and end-to-end anastomosis was performed between the external jugular vein and the jejunal vein. The right recurrent laryngeal nerve injury was repaired with a 4-cm nerve graft from the right ansa cervicalis. Esophagography at 1 year after surgery confirmed that there were no leaks or structures, endoscopy at 1 year confirmed the resolution of vocal cord paralysis, and there were no residual problems with swallowing or speech at a 5-year follow-up examination. RAT requires experienced surgeons with a thorough knowledge of anatomy, as well as adequate resources to quickly and competently address potentially severe complications such as esophageal rupture.

A new CNC system for free-form body machining with a cylindrical tool

  • Urata, Eizo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.9-23
    • /
    • 1993
  • Free-form surface machining is usually performed with an NC milling machine and a ball end milling cutter. Since this conventional method is basically sculpting on a plane, it is not suitable for three dimensional body machining. This article will introduce a new machining method for three dimensional body with free-form surface and newly developed machine tool suitable for such machining.

  • PDF

Free vibration of tapered arches made of axially functionally graded materials

  • Rajasekaran, S.
    • Structural Engineering and Mechanics
    • /
    • v.45 no.4
    • /
    • pp.569-594
    • /
    • 2013
  • The free vibration of axially functionally graded tapered arches including shear deformation and rotatory inertia are studied through solving the governing differential equation of motion. Numerical results are presented for circular, parabolic, catenary, elliptic and sinusoidal arches with hinged-hinged, hinged-clamped and clamped-clamped end restraints. In this study Differential Quadrature element of lowest order (DQEL) or Lagrangian Interpolation technique is applied to solve the problems. Three general taper types for rectangular section are considered. The lowest four natural frequencies are calculated and compared with the published results.

Differential quadrature method for free vibration analysis of coupled shear walls

  • Bozdogan, K.B.
    • Structural Engineering and Mechanics
    • /
    • v.41 no.1
    • /
    • pp.67-81
    • /
    • 2012
  • Differential Quadrature Method (DQM) is a powerful method which can be used to solve numerical problems in the analysis of structural and dynamical systems. In this study the governing equation which represents the free vibration of coupled shear walls is solved using the DQM method. A one-dimensional model has been used in this study. At the end of study various examples are presented to verify the accuracy of the method.

Free Vibrations of Beams with Static Deflections due to Dead Loads (사하중에 의한 정적 처짐을 고려한 보의 자유진동)

  • 이병구;박광규;오상진;모정만
    • Journal of KSNVE
    • /
    • v.4 no.4
    • /
    • pp.451-457
    • /
    • 1994
  • A numerical method is presented to obtain natural frequencies and mode shapes of uniform elastic beams with static deflections due to dead loads. The differential equation governing the free vibration of beam taken into account the static deflection due to deal loads is derived and solved numerically. The hinged-hinged, clamped-clamped and clamped-hinged end constraints are applied in the numerical examples. As the numerical results, the lowest three nondimensional frequency parameters are reported as functions of nondimensional system parameters; the load parameters, and the slenderness rations. And some typical mode shapes of free vibrations are also presented in figures.

  • PDF

Lead-free Solder Technology and Reliability for Automotive Electronics (자동차 전장용 무연 솔더 기술)

  • Lee, Soon-Jae;Jung, Jae-Pil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.3
    • /
    • pp.1-7
    • /
    • 2015
  • In this study, properties of Pb-free solders for automotive electronics parts were discussed. Lead-free solders for electronics became important after RoHS (Restriction of the use of certain Hazardous Substances) to avoid environmental pollution. Also the growing electronic rate in automotive parts and ELV (End-of Life Vehicles) make Pb-free solder for automotive electronics to be inevitable trend. Definitely, Pb-free solder for automotive electronics should have good wettability, basic strength, but need more reliability than other solders, since it has harsh condition like high temperature, humidity and engine vibration. Thus, shear strength test, thermal shock, drop test and many others are needed to ensure the high reliability. This study describes the properties and requirements of Pb-free solders for automotive electronics.

Dynamic Stability of a Free-Free Beam with a Tip Rigid Body under a Controlled Pulsating Thrust (끝단 강체를 갖고 맥동 제어추력을 받는 양단 자유보의 동적 안정성)

  • Ryu, Bong-Jo;Lee, Gyu-Seop;Seong, Yun-Gyeong;Choe, Bong-Mun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.1 s.173
    • /
    • pp.232-239
    • /
    • 2000
  • The paper describes the parametric instability of free-free beams subjected to a controlled pulsating follower force. The beam has a tip rigid body not a mass point, and the direction of pulsating follower force is controlled by the direction control sensor. Equations of motion are derived by Hamilton's principle and the instability regions are obtained by finite element formulation. The effects of magnitude, rotary inertia, the distance between free end of the beam and the center of gravity of the rigid body on the instability types and regions are investigated by the change of the constant and periodic part of the follower force.

Adoption of the large scale free-free resonant column test (대형 공진주 시험 장비의 적용)

  • Park, In-Beom;Park, Chul-Soo;Mok, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.626-633
    • /
    • 2009
  • A large scale resonant column testing equipment is under development. The would-be equipment is aiming to test 150mm-diameter specimens, which can contain as large a grain size as 25mm. Such a large specimen is hardly excitated with the existing fixed-free end condition because the torsional force cannot be effectively coupled to the specimen. The specimen will be rather resonated with free-free condition and the scheme is implemented with a rotational bearing installed between coil-magnet exciter and base pedestal. Presently the equipment was assembled and is under calibration with a cylindrical brass specimen.

  • PDF

Continuous Sutures for Microarterial Anastomosis (미세혈관 수술시 혈관개존율 향상을 위한 연구)

  • Jung, Young-Sik;Jeong, Jae-Ho;Choi, See-Ho;Seul, Jung-Hyun
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.237-241
    • /
    • 1986
  • In clinical microsurgery, limitation of space often prohibits rotation of a double clamp in an end-to-end anastomosis, or shortage of length of the secondary vessel in an end-to-side anastomosis does not allow visualization of the back wall. In these situation, back wall repair is extremely difficult. To overcome this problem, we use continuous suture technique without rotation of double clamp for end-to-end and end-to-side anastomosis of the 40 rat femoral arteries. After continuous sutures for microarterial anastomosis, the following results were obtained: Continuous sutures are useful in anastomosis where there is unavoidable limited access to the posterior wall and for some of the larger vessels now being anastomosed in free flap and other reconstructive surgery.

  • PDF