• Title/Summary/Keyword: Frame Score

Search Result 73, Processing Time 0.037 seconds

Subjective Evaluation of Ultra-high Definition (UHD) Videos

  • Rahim, Tariq;Shin, Soo Young
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.6
    • /
    • pp.2464-2479
    • /
    • 2020
  • This paper presents a detailed subjective quality assessment for the ultra-high definition (UHD) videos having frame rates of 30fps and 60 fps. The subjective assessment is based on the ITU-R BT-500 recommendations, where double stimulus continuous quality scale (DSCQS-type II) test is performed for the evaluation of the perceived quality of the user's in terms of differential mean opinion score (DMOS). Encoding of the UHD videos by opting encoders i.e. H.264/AVC, H.265/HEVC, and VP9 at five different quantization parameter (QP) levels is done to investigate the perceived user's quality of experience (QoE) given as DMOS. Moreover, the encoding efficiency as the encoding time for each encoder and qualitative performance by employing full-reference (FR) quality metrics are presented in this work.

An algorithm for pattern recognition of multichannel ECG signals using AI (AI기법을 이용한 멀티채널 심전도신호의 패턴인식 알고리즘)

  • 신건수;이병채;황선철;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.575-579
    • /
    • 1990
  • This paper describes an algorithm that can efficiently analyze the multichannel ECG signal using the frame. The input is a set of significant features (points) which have been extracted from an original sampled signal by using the split-and-merge algorithm. A signal from each channel can be hierarchical ADN/OR graph on the basis of the priori knowledge for ECG signal. The search mechanisms with some heuristics and the mixed paradigms of data-driven hypothesis formation are used as the major control mechanisms. The mutual relations among features are also considered by evaluating a score based on the relational spectrum. For recognition of morphologies corresponding to OR nodes, an hypothesis modification strategy is used. Other techniques such as instance, priority update of prototypes, and template matching facility are also used. This algorithm exactly recognized the primary points and supporting points from the multichannel ECG signals.

  • PDF

The Effects of Velocity of Propulsion on the Degree of Hardship Performance during a Figure Skating (피겨스케이팅 활주속도가 운동수행기술 발휘에 미치는 영향)

  • Yoo, Kyoung-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.165-172
    • /
    • 2007
  • The purpose of this study was to examine the effects of the result of hardship performance of the propulsion speed on the flying carmel spins during a Figure Skating. The subjects were five the korea national representative players. Kinematic variables were analyzed 5frame of the excursion phase by the three-dimensional motion analysis system(60Hz). The obtained conclusion were as follows: In this study, during the propulsion classify two groups as "type I" the acceleration patterns S3, S4 and "type II" the uniform velocity group S1, S2, S5. The results of percentage comparative analysis between type I and type II can be summarized as below: the height of jump(24%), the height of COM(25%), the maximum speed of Roundhouse Kick(21%), the judging technical score(18%), the flight time(13%), the velocity of spins(4%), the distance of flight(-6%) Analysis of the results on performance variables, the velocity pattern of the type I showed comparatively excellence than that of type II.

Audio Stream Delivery Using AMR(Adaptive Multi-Rate) Coder with Forward Error Correction in the Internet (인터넷 환경에서 FEC 기능이 추가된 AMR음성 부호화기를 이용한 오디오 스트림 전송)

  • 김은중;이인성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.12A
    • /
    • pp.2027-2035
    • /
    • 2001
  • In this paper, we present an audio stream delivery using the AMR (Adaptive Multi-Rate) coder that was adopted by ETSI and 3GPP as a standard vocoder for next generation IMT-2000 service in which includes combined sender (FEC) and receiver reconstruction technique in the Internet. By use of the media-specific FEC scheme, the possibility to recover lost packets can be much increased due to the addition of repair data to a main data stream, by which the contents of lost packets can be recovered. The AMR codec is based on the code-excited linear predictive (CELP) coding model. So we use a frame erasure concealment for CELP-based coders. The proposed scheme is evaluated with ITU-T G.729 (CS-ACELP) coder and AMR - 12.2 kbit/s through the SNR (Signal to Noise Ratio) and the MOS (Mean Opinion Score) test. The proposed scheme provides 1.1 higher in Mean Opinion Score value and 5.61 dB higher than AMR - 12.2 kbit/s in terms of SNR in 10% packet loss, and maintains the communicab1e quality speech at frame erasure rates lop to 20%.

  • PDF

Video Quality Metric Using One-Dimensional Histograms of Motion Vectors (움직임 벡터의 1차원 히스토그램을 이용한 비디오 화질 평가 척도)

  • Han, Ho-Sung;Kim, Dong-O;Park, Bae-Hong;Sim, Dong-Gyu
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.2
    • /
    • pp.21-28
    • /
    • 2008
  • This paper proposes a novel reduced-reference assessment method for video quality assessment, in which one-dimensional (1-D) histograms of motion vectors (MVs) are used as features of videos. The proposed method is more efficient than the conventional methods in view of computation time, because the proposed quality metric decodes MVs directly from video stream in the parsing process instead of reconstructing the distorted video at the receiver. Moreover, in view of data size, the propose method is efficient because a sender transmits 1-D histograms of MVs accumulated over whole input video sequences. Here, we use 1-D histograms of MVs accumulated over the whole video sequences, which is different from the conventional methods that assessed each image independently. For testing the similarity between histograms, we use histogram intersection and histogram difference methods. We compare the proposed method with the conventional methods for 52 video clips, which are coded under varying bit rate, image size, and frame rate. Experimental results show that the proposed method is more efficient than the conventional methods and that the proposed method is more similar to the mean opinion score (MOS) than conventional algorithms.

A Study for the Development of Standardized Management Manuel in Sanhujoriwon - Centered on the Management of Women & Newborn - (산후조리원의 표준화 관리 지침을 위한 연구 - 산모와 신생아 관리현황을 중심으로 -)

  • Jung, Eun-Sil;Yoo, Eun-Kwang
    • Women's Health Nursing
    • /
    • v.8 no.2
    • /
    • pp.301-313
    • /
    • 2002
  • The purpose of this study was to develop the frame for standardized manual for Sanhujoriwon by finding out the status of the management of women & newborn in Sanhujoriwon, like postpartum care center. The subjects were 95 staffs of 22 Sanhujoriwon agreed on oral consent, in Seoul and Bundang, Korea. Data were collected from Sep. 15 to Oct. 24, 2001. The instrument used for this study was a structured questionnaire consisted of 16 items of general characteristics & educational characteristics about postpartum care, 31 items of degree of management of women's postpartum care (Cronbach's $\alpha$.93 ), 24 items of degree of management of newborn's care(Cronbach's $\alpha$.94 ), 10 items of methods of management of women's postpartum care, 8 items of methods management of newborn's care. The data were analyzed by the SPSS/PC+ program using frequency, percentage, mean, standard deviation, t-test, ANOVA and Pearson correlation coefficient. The results of the study were as follows ; 1. The mean of the degree of management for postpartum women was 4.1. The mean score for the degree of management of general postpartum care for women was 4.00 & traditional postpartum care(Sanhujori) was 4.20. The degree of management of traditional postpartum care was higher than general postpartum care for women. 2. The degree of management for newborn : The mean score for the degree of management of newborn was 4.37. 3.There was a strong positive correlation between general postpartum care and traditional postpartum care($r=.744^{**}$), and postpartum mother care and newborn care($r=.798^{**}$). 4.The basic frame for the management of the women and newborn in Sanhujoriwon. 1) For women: Integrated postpartal care Physical management : Vital sign & BP check, contraction of uterus, form and amount of lochia, management of personal hygiene, management of breast & breast-feeding, management of postpartum exercise, prevention of infection, symptom & sign of high risk and prevention & management of high risk condition; Emotional-psychological management: assessment and management of mother-baby attachment, emotional state; Educational management : education of vaccination schedule, urinary incontinence, rearing infant, breast-feeding ; and Environmental management : temperature, humidity, disinfection, cleaning, light, infection control integrated with 6 principles of Sanhujori. 2) For newborn Physical management : check of vital sign, management of umbilical cord, jaundice, prevention of infection, management of diaper rash; Emotional-psychological management : assessment of sleep, crying, activity, response of mother-baby attachment; and Environmental management : temperature, humidity, disinfection, cleaning, light, infection control integrated with 6 principles of Sanhujori. In conclusion Sanhujoriwon must be health care center for the postpartum women and newborn. Therefore, the establishment of various laws and regulations in such a way to meet the realistic needs of Sanhujoriwon as a health care center for women and infants future health should be done. The standardized management manual based on the results is absolutely required above all.

  • PDF

A COMPARISON OF PERIAPICAL RADIOGRAPHS AND THEIR DIGITAL IMAGES FOR THE DETECTION OF SIMULATED INTERPROXIMAL CARIOUS LESIONS (모의 인접면 치아우식병소의 진단을 위한 구내 표준방사선사진과 그 디지털 영상의 비교)

  • Kim Hyun;Chung Hyun-Dae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.279-290
    • /
    • 1994
  • The purpose of this study was to compare the diagnostic accuracy of periapical radiographs and their digitized images for the detection of simulated interproximal carious lesions. A total of 240 interproximal surfaces was used in this study. The case sample was composed of 80 anterior teeth, 80 bicuspids and 80 molars which were prepared in order to distribute the surfaces from carious free to those containing simulated carious lesions of varying depths (0.5㎜, 0.8㎜, and 1.2㎜). The periapical radiographs were taken by paralleling technique and film used was Kodak Ektaspeed(E group). All radiographs were evaluated by five dentist to recognize the true status of simulated carious lesion. They were asked to give a score of 0, 1, 2, or 3. Digitized images were obtained using a commercial video processor(FOTOVIX Ⅱ- XS). And the computer system was 486 DX PC with PC Vision and frame grabber. The 17' display monitor had a resolution of 1280×1024 pixels(0.26㎜ dot pitch). But the one frame of the intraoral radiograph has a resolution of 700×480 pixels and each pixel has a grey level value of 256. All the radiographs and digital images were viewed under uniform subdued lighting in the same reading room. After a week the second interpretation was performed in the same condition. The detection of lesions on the monitor was compared with the finding of simulated interproximal carious lesions on the film images. The results were as follows: 1. When the scoring criteria was dichotomous ; lesion present and not present 1) The overall sensitivity, specificity and diagnostic accuracy of periapical radiographs and their digital images showed no statistically significant difference. 2) The sensitivity and specificity according to the region of teeth and the grade of lesions showed no statistically significant difference between periapical radiographs and their digital images. 2. When estimate the grade of lesions ; score 0, 1, 2, 3 1) The overall diagnostic accuracy was 53.3% on the intraoral films and 52.9% on digital images. There was no significant difference. 2) The diagnostic accuracy according to the region of teeth showed no statistically significant difference between periapical radiographs and their digital images. 3. The degree of agreement and reliability 1) Using gamma value to show the degree of agreement, there was similarity between periapical films and digital images. 2) The reliability of each twice interpretation of periapical films and digital images showed no statistically significant difference. In all cases P value was greater than 0.05, showing that both techniques can be used to detect the incipient and moderate interproximal carious lesions with similar accuracy.

  • PDF

Efficacy of Ilizarov External Fixation and Autologous Bone Grafting for Performing Arthrodesis on the Ankle Arthropathy with Risk Factors (불유합의 위험 인자를 가진 족관절 병변에 시행한 족관절 유합술로서 Ilizarov 외고정 기구 장착술 및 자가골 이식술의 유용성)

  • Lee, Yong-Sik;Nam, Il-Hyun;Lee, Tae-Hun;Ahn, Gil-Yeong;Lee, Yeong-Hyeon;Lee, Hee-Hyung;Hwang, Sung-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.4
    • /
    • pp.189-195
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate if the Ilizarov external fixation procedure with axial compression can help to obtain fusion across the ankle joint in patients with a high risk of nonunion. Materials and Methods: From January 2006 to December 2015, the study reviewed 17 patients who underwent ankle arthropathy with a high risk of nonunion and who underwent ankle fusion using the Ilizarov external fixator with axial compression and auto bone grafting. After the lateral surface of the ankle joint was exposed through a lateral trans-fibular approach, massive removal of the articular cartilage and excision of any loose or avascular bone were done. With the cortical bone harvested from the pelvis as corticocancellous bone blocks, we inserted the two cortical blocks longitudinally into the anterior and posterior part of the free ankle space from lateral to medial to make the rectangular chamber to fill the cancellous bones. After the Ilizarov external fixator was equipped, we tightened the frame by 5 mm to compress the bone graft space. We accessed the American Orthopaedic Foot and Ankle Society (AOFAS) AnkleHindfoot score both preoperatively and postoperatively. Results: The average age at the time of operation was 63.4 years (range, 47~78 years). The mean frame time was 17.4 weeks (range, 15~23 weeks). The average follow-up period was 3.7 years (range, 2~6 years). Osseous fusion was obtained in 15 patients (88.2%). There were two stable pseudarthroses among the rheumatoid arthritis patients, and we continued their follow-up. The mean AOFAS AnkleHindfoot score improved from 48.5 to 73.7 points. Conclusion: Ankle arthrodesis using the Ilizarov external fixation with axial compression and auto bone grafting on the ankle arthropathy that had difficult conditions to achieve union is considered one of the useful methods with a correspondingly low incidence of complications.

A Novel Approach to a Robust A Priori SNR Estimator in Speech Enhancement (음성 향상에서 강인한 새로운 선행 SNR 추정 기법에 관한 연구)

  • Park, Yun-Sik;Chang, Joon-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.8
    • /
    • pp.383-388
    • /
    • 2006
  • This Paper presents a novel approach to single channel microphone speech enhancement in noisy environments. Widely used noise reduction techniques based on the spectral subtraction are generally expressed as a spectral gam depending on the signal-to-noise ratio (SNR). The well-known decision-directed(DD) estimator of Ephraim and Malah efficiently reduces musical noise under the background noise conditions, but generates the delay of the a prioiri SNR because the DD weights the speech spectrum component of the Previous frame in the speech signal. Therefore, the noise suppression gain which is affected by the delay of the a priori SNR, which is estimated by the DD matches the previous frame rather than the current one, so after noise suppression. this degrades the noise reduction performance during speech transient periods. We propose a computationally simple but effective speech enhancement technique based on the sigmoid type function for the weight Parameter of the DD. The proposed approach solves the delay problem about the main parameter, the a priori SNR of the DD while maintaining the benefits of the DD. Performances of the proposed enhancement algorithm are evaluated by ITU-T p.862 Perceptual Evaluation of Speech duality (PESQ). the Mean Opinion Score (MOS) and the speech spectrogram under various noise environments and yields better results compared with the fixed weight parameter of the DD.

Matching Pursuit Sinusoidal Modeling with Damping Factor (Damping 요소를 첨가한 매칭 퍼슈잇 정현파 모델링)

  • Jeong, Gyu-Hyeok;Kim, Jong-Hark;Lim, Joung-Woo;Joo, Gi-Ho;Lee, In-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.1
    • /
    • pp.105-113
    • /
    • 2007
  • In this paper, we propose the matching pursuit with damping factors, a new sinusoidal model improving the matching pursuit, for the codecs based on sinusoidal model. The proposed model defines damping factors by using a correlativity of parameters between the current and adjacent frame, and estimates sinusoidal parameters more accurately in analysis frame by using the matching pursuit according to damping factor, and synthesizes the final signal. Then it is possible to model efficiently without interpolation schemes. The proposed sinusoidal model shows a better speech quality without an additional delay than the conventional sinusoidal model with interpolation methods. Through the SNR(signal to noise ratio), the MOS(Mean Opinion Score), LR(Itakura-Saito likelihood ratio), and CD(cepstral distance), we compare the performance of our model with that of matching pursuit using interpolation methods.