• 제목/요약/키워드: Fragility Test

검색결과 47건 처리시간 0.022초

Seismic fragility of a typical bridge using extrapolated experimental damage limit states

  • Liu, Yang;Paolacci, Fabrizio;Lu, Da-Gang
    • Earthquakes and Structures
    • /
    • 제13권6호
    • /
    • pp.599-611
    • /
    • 2017
  • This paper improves seismic fragility of a typical steel-concrete composite bridge with the deck-to-pier connection joint configuration at the concrete crossbeam (CCB). Based on the quasi-static test on a typical steel-concrete composite bridge model under the SEQBRI project, the damage states for both of the critical components, the CCB and the pier, are identified. The finite element model is developed, and calibrated using the experimental data to model the damage states of the CCB and the bridge pier as observed from the experiment of the test specimen. Then the component fragility curves for both of the CCB and the pier are derived and combined to develop the system fragility curves of the bridge. The uncertainty associated with the mean system fragility has been discussed and quantified. The study reveals that the CCB is more vulnerable than the pier for certain damage states and the typical steel-concrete composite bridge with CCB exhibits desirable seismic performance.

Seismic fragility evaluation of the base-isolated nuclear power plant piping system using the failure criterion based on stress-strain

  • Kim, Sung-Wan;Jeon, Bub-Gyu;Hahm, Dae-Gi;Kim, Min-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.561-572
    • /
    • 2019
  • In the design criterion for the nuclear power plant piping system, the limit state of the piping against an earthquake is assumed to be plastic collapse. The failure of a common piping system, however, means the leakage caused by the cracks. Therefore, for the seismic fragility analysis of a nuclear power plant, a method capable of quantitatively expressing the failure of an actual piping system is required. In this study, it was conducted to propose a quantitative failure criterion for piping system, which is required for the seismic fragility analysis of nuclear power plants against critical accidents. The in-plane cyclic loading test was conducted to propose a quantitative failure criterion for steel pipe elbows in the nuclear power plant piping system. Nonlinear analysis was conducted using a finite element model, and the results were compared with the test results to verify the effectiveness of the finite element model. The collapse load point derived from the experiment and analysis results and the damage index based on the stress-strain relationship were defined as failure criteria, and seismic fragility analysis was conducted for the piping system of the BNL (Brookhaven National Laboratory) - NRC (Nuclear Regulatory Commission) benchmark model.

상사법칙이 적용된 철근콘크리트 기둥 축소모형의 지진 취약도 분석 (Fragility Analysis of A Scaled Model of Reinforced Concrete Column in Accordance with Similitude Law)

  • 박동욱;전법규;김남식;박자민;조재열
    • 한국지진공학회논문집
    • /
    • 제21권2호
    • /
    • pp.87-93
    • /
    • 2017
  • Many studies are conducted in several fields for fragility analysis of structures or elements which is a probabilistic seismic safety analysis in consideration with uncertainty of seismic loading. It is hard to directly conduct fragility analysis for an infrastructure with social importance due to its size. Therefore, a fragility analysis for an infrastructure mainly conducted in element level or conducted with scaled model built in accordance with similarity law. In this article, fragility analysis for prototype and scaled model of reinforced concrete column was conducted with numerical models which had been updated by the results of shaking table test and pseudo dynamic test. As a result, response stress from the numerical analysis result of prototype model was higher than that from scaled model due to different stiffness ratios between steel and concrete. However, the probability of failure for scaled model was higher than that for prototype model because failure criteria for scaled model was down due to similarity law. Also it was evaluated that probability of failure by using log normal standard deviation of response stresses by spectrum matched accelerograms was more reliable than probability of failure by using existing coefficient of variation normally used.

A new damage index for seismic fragility analysis of reinforced concrete columns

  • Kang, Jun Won;Lee, Jeeho
    • Structural Engineering and Mechanics
    • /
    • 제60권5호
    • /
    • pp.875-890
    • /
    • 2016
  • A new structural damage index for seismic fragility analysis of reinforced concrete columns is developed based on a local tensile damage variable of the Lee and Fenves plastic-damage model. The proposed damage index is formulated from the nonlinear regression of experimental column test data. In contrast to the response-based damage index, the proposed damage index is well-defined in the form of a single monotonically-increasing function of the volume weighted average of local damage distribution, and provides the necessary computability and objectivity. It is shown that the present damage index can be appropriately zoned to be used in seismic fragility analysis. An application example in the computational seismic fragility evaluation of reinforced concrete columns validates the effectiveness of the proposed damage index.

기와집 1/2 축소 모델의 지진 실험 (Seismic Test of a 1/2 Scale Model of Wood House with Tiled Roof)

  • 류혁;김재관;전봉희;김병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.362-367
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with tiled roof was performed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

기와집 실물크기 모델의 지진 실험 (Seismic Test of a Full Scale Model of Wood House with Tiled Roof)

  • 류혁;김재관;전봉희;김병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.368-373
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a full scale model of wood house with tiled roof was performed. Full scale model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

초가집 1/2 축소 모델의 지진 실험 (Seismic Test of a 1/2 Scale Model of Wood House with Thatched Roof)

  • 류혁;김재관;허영철;전봉희
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.247-252
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with thatched roof was peformed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

콘크리트 표면차수벽형 석괴댐의 지진 취약도 평가 (Evaluation of Seismic Fragility of Concrete Faced Rockfill Dam)

  • 백종민;박두희;윤지남;최병한
    • 한국지반신소재학회논문집
    • /
    • 제17권4호
    • /
    • pp.103-108
    • /
    • 2018
  • 본 연구에서는 지반진동 강도에 따른 콘크리트 표면차수벽 석괴댐(CFRD)의 확률론적 피해예측을 위하여 취약도 함수를 개발하였다. 댐의 손상평가에 널리 사용되는 지표인 댐마루 침하량을 손상지수로 사용하여 경미(Minor), 중간(Moderate), 심각(Severe) 손상수준을 정의하였다. 침하량은 댐 표준단면에 대한 비선형 동적 수치해석을 통하여 계산하였다. 수치해석 모델은 원심모형시험결과와 비교하여 정확성을 검증하였다. 취약도 곡선은 대수정규분포함수로 나타내어 최대지반가속도를 기준으로 도출하였다. 본 연구에서 도출된 취약도 곡선은 댐의 실시간 피해예측에 활용될 수 있을 것으로 판단된다.

지진격리된 원전배관의 지진취약도 분석 (Seismic Fragility Analysis of Base Isolated NPP Piping Systems)

  • 전법규;최형석;함대기;김남식
    • 한국지진공학회논문집
    • /
    • 제19권1호
    • /
    • pp.29-36
    • /
    • 2015
  • Base isolation is considered as a seismic protective system in the design of next generation Nuclear Power Plants (NPPs). If seismic isolation devices are installed in nuclear power plants then the safety under a seismic load of the power plant may be improved. However, with respect to some equipment, seismic risk may increase because displacement may become greater than before the installation of a seismic isolation device. Therefore, it is estimated to be necessary to select equipment in which the seismic risk increases due to an increase in the displacement by the installation of a seismic isolation device, and to perform research on the seismic performance of each piece of equipment. In this study, modified NRC-BNL benchmark models were used for seismic analysis. The numerical models include representations of isolation devices. In order to validate the numerical piping system model and to define the failure mode, a quasi-static loading test was conducted on the piping components before the analysis procedures. The fragility analysis was performed by using the results of the inelastic seismic response analysis. Inelastic seismic response analysis was carried out by using the shell finite element model of a piping system considering internal pressure. The implicit method was used for the direct integration time history analysis. In addition, the collapse load point was used for the failure mode for the fragility analysis.

전북지역 한우의 red cell fragility와 glutathione peroxidase활성에 관한 연구 (Studies on red cell fragility and glutathione peroxidase activities in Korean native cattle of Chonbuk region)

  • 조종후;이성희
    • 대한수의학회지
    • /
    • 제30권3호
    • /
    • pp.271-275
    • /
    • 1990
  • The tests related to red cell fragility were performed. Samples of blood anticoagulated with heparin were obtained from Korean native cattle in Chonbuk region abattoir, and classified by the district(Kun) with reference to breeding location. Hemolysis test for red cell fragility was performed with whole blood and glutathione peroxidase activity was measured spectrophotometrically. Blood concentration of selenium, inorganic component of glutathione peroxidase, was also determined fluorophotometrically. The results obtained were summerized as follows; 1. Percent hemolysis of erythrocytes ranged from 13.53 to 20.74%, and its mean Palue was low as $17.11{\pm}9.91%$. Means in all were not district(Kun) in Chonbuk region significantly different. 2. Glutathione peroxidase activity ranged from 2,881 to 4,000mU/ml, and high mean values, $3,352{\pm}1,872mU/ml$, reflected low percent hemolysis. 3. There was a highly negative correlation between the red cell fragility(Y) and blood glutathione peroxidase activity(X). The linear regression equation for these data was: Y=29.86-3.75X with a correlation coefficient of r=-.6886 (p<0.01) 4. Blood selenium concentration ranged from 0.16 to $0.24{\mu}g/ml$, and mean values was normal level as $0.2{\pm}0.11{\mu}g/ml$. 5. There was a highly positive correlation between blood selenium concentration(X), and blood glutathione peroxidase activity(Y). The linear regression for these data was: Y=230+15,790X, with a correlation coefficient officient of r=0. 8635.

  • PDF