• 제목/요약/키워드: Fracture stress

검색결과 2,427건 처리시간 0.218초

Residual Stress and Fracture Analysis of Thick Plate for Partial Penetration Multi-pass Weldment (후판 부분용입 다층용접의 잔류음력 및 파괴 해석)

  • Kim, Seok;Shim, Yong-Lae;Bae, Sung-In;Song, Jung-Il
    • Journal of Welding and Joining
    • /
    • 제19권6호
    • /
    • pp.636-642
    • /
    • 2001
  • Partial penetration welding joint defines the groove welds that applies the one side welding which does not use steel backing and both side welding without back gouging, that is, the partial penetration welding joint leaves an unwelded portion at the root of the welding area. In this study, we analyzed the residual stress and fracture on the thick metal plates that introduced the partial penetration welding method. As results of using above mentioned welding method, we could draw a conclusion that longitudinal stress and traverse stress occurred around the welding area was so minimal and did not affect any influence. We also performed the fracture behavior evaluation on the partial penetration multi-pass welding with 25.4mm thick plate by using theJ-integral, which finally led us the conclusion that the partial penetration multi -pass welding method is more applicable and effective in handling the root face with less than 6.35mm.

  • PDF

The Operative Management of Navicular Stress Fractures in Adolescence (청소년기에 발생한 주상골 피로 골절의 수술적 처치)

  • Lee, Kyung Tai;Kim, Ki Chun;Young, Ki Won;Cho, Chang Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • 제20권4호
    • /
    • pp.170-175
    • /
    • 2016
  • Purpose: The aim of this study is to evaluate the effectiveness of surgical treatment in adolescent patients suffering from navicular stress fracture. Materials and Methods: A total of 11 adolescent patients aged 14 to 19, who underwent an operation for navicular stress fracture between 2005 and 2008 were recruited. Clinical outcomes were evaluated by the American Orthopaedic Foot and Ankle Society (AOFAS) midfoot score and visual analogue scale (VAS) score. Results: The mean VAS score before the operation was 7.7. A score of 2.9 was confirmed at final follow up after the operation. The mean final follow-up period was 22.1 months. There was a statistically significant improvement in the VAS score between before and after the operation (p=0.01), and similarly, the AOFAS score also showed an improvement, from 46.5 to 80.7 (p=0.01). The pain that remained after the operation, according to the VAS score, was severe in three patients (27.3%), tolerable in seven patients (63.6%), and free of pain in one patient (9.1%). Conclusion: In navicular stress fracture in adolescents, careful selection of patients who could benefit from surgical treatment is recommended.

Critical evaluation of fracture strength testing for endodontically treated teeth: a finite element analysis study

  • Uzunoglu-Ozyurek, Emel;Eren, Selen Kucukkaya;Eraslan, Oguz;Belli, Sema
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.15.1-15.8
    • /
    • 2019
  • Objectives: The aim of this study was to investigate whether the diameter and direction of the plunger and simulation of the periodontal ligament (PDL) affected the stress distribution in endodontically treated premolars. Methods: A fracture strength test was simulated via finite element analysis. A base model was set up, and the following parameters were modified: plunger diameter (3 mm vs. 6 mm), plunger direction (vertical vs. $135^{\circ}$ angular to the central fossa), and PDL simulation. The analysis was conducted using the CosmosWorks structural analysis program, and the results are presented in terms of von Mises stresses. Results: The smaller plunger increased the stresses at the contact area of the crown, but the plunger diameter had no effect on the stress distribution within the root. An angular plunger direction increased stresses within the root, as well as at the buccal cusp of the crown, compared with the vertical direction. Simulation of the PDL caused higher stress accumulation, especially in the cervical region of the root. Conclusions: The plunger diameter had no effect on the stress distribution in the roots, whereas the plunger direction and PDL simulation did affect the stress distribution. More stringent standards can be established by taking such parameters into account when performing fracture testing in future studies.

Stress Fracture of the Proximal Clavicle after Parallel Bars Exercise in a Young Male (젊은 남성에서 평행봉 운동 중 발생한 쇄골 근위부 피로 골절)

  • Kwon, Jieun;Lee, Ye Hyun;Cho, Joon Hee
    • Journal of the Korean Orthopaedic Association
    • /
    • 제54권3호
    • /
    • pp.287-291
    • /
    • 2019
  • Although acute traumatic fractures of the clavicle are relatively common, stress fractures of the proximal clavicle are extremely rare. Stress fractures of the clavicle have often been reported after a radical neck dissection or radiation but rarely occur during excessive repetitive exercise in professional athletes. The authors report a case of a stress fracture of the proximal clavicle during exercise in a young man with no specific preceding factors, which has not been reported in the Korean literature.

Effect of Corrosion Atmosphere and Strain Rate on the Stress Corrosion Cracking of High Strength 7xxx Aluminum Alloy (고강도 7xxx 알루미늄 합금의 응력부식균열에 미치는 부식환경과 응력속도의 영향)

  • Yun, Yeo-Wan;Kim, Sang-Ha
    • Journal of the Korean institute of surface engineering
    • /
    • 제41권3호
    • /
    • pp.121-128
    • /
    • 2008
  • High strength 7xxx aluminum alloys have been applied to automotive bump back beam of the some limited model for light weight vehicle. The aluminum bump back beam is manufactured through extrusion, bending and welding. The residual stress given on these processes combines with the corrosive atmosphere on the road spreaded with corrosive chemicals to melt snow to occur the stress corrosion cracking. The composition of commercial 7xxx aluminum has Zn/Mg ratio about 3 and Cu over 2 wt% for better strength and stress corrosion cracking resistivity. But this composition isn't adequate for appling to the automotive bump back beam with high resistance to extrusion and bad weldability. In this study the composition of 7xxx aluminum alloy was modified to high Zn/Mg ratio and low Cu content for better extrusion and weldability. To estimate the resistivity against stress corrosion cracking of this aluminum alloy by slow strain rate test, the corrosion atmosphere and strain rate separate the stress corrosion cracking from conventional corrosion must be investigated. Using 0.6 Mol NaCl solution on slow strain rate test the stress corrosion cracking induced fracture was not observed. By adding 0.3% $H_2O_2$ and 0.6M $Na_2SO_4$ to 1M NaCl solution, the corrosion potential and current density of polarization curve moved to active potential and larger current density, and on the slow strain rate test the fracture energy in solution was lower than that in pre-exposure. These mean the stress corrosion cracking induced fracture can be estimated in this 1M NaCl + 0.3% $H_2O_2$ + 0.6M $Na_2SO_4$ solution. When the strain rate was below $2{\times}10^{-6}$, the stress corrosion cracking induced fracture start to be observed.

Mechanical and fracture behavior of rock mass with parallel concentrated joints with different dip angle and number based on PFC simulation

  • Zhao, Weihua;Huang, Runqiu;Yan, Ming
    • Geomechanics and Engineering
    • /
    • 제8권6호
    • /
    • pp.757-767
    • /
    • 2015
  • Rock mass is an important engineering material. In hydropower engineering, rock mass of bank slope controlled the stability of an arch dam. However, mechanical characteristics of the rock mass are not only affected by lithology, but also joints. On the basis of field geological survey, this paper built rock mass material containing parallel concentrated joints with different dip angle, different number under different stress conditions by PFC (Particle Flow Code) numerical simulation. Next, we analyzed mechanical property and fracture features of this rock mass. The following achievements have been obtained through this research. (1) When dip angle of joints is $15^{\circ}$ and $30^{\circ}$, with the increase of joints number, peak strength of rock mass has not changed much. But when dip angle increase to $45^{\circ}$, especially increase to $60^{\circ}$ and $75^{\circ}$, peak strength of rock mass decreased obviously with the increase of joints number. (2) With the increase of confining stress, peak strengths of all rock mass have different degree of improvement, especially the rock mass with dip angle of $75^{\circ}$. (3) Under the condition of no confining stress, dip angle of joints is low and joint number is small, existence of joints has little influence on fracture mode of rock mass, but when joints number increase to 5, tensile deformation firstly happened at joints zone and further resulted in tension fracture of the whole rock mass. When dip angle of joints increases to $45^{\circ}$, fracture presented as shear along joints, and with increase of joints number, strength of rock mass is weakened caused by shear-tension fracture zone along joints. When dip angle of joints increases to $60^{\circ}$ and $75^{\circ}$, deformation and fracture model presented as tension fracture zone along concentrated joints. (4) Influence of increase of confining stress on fracture modes is to weaken joints' control function and to reduce the width of fracture zone. Furthermore, increase of confining stress translated deformation mode from tension to shear.

Study on Failure Characteristics of Laminate with a Hole (원공이 있는 복합적층판의 파괴특성 연구)

  • K.H.,Song;J.W.,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • 제26권4호
    • /
    • pp.67-80
    • /
    • 1989
  • This Paper is concerned with the fracture behavoir of Unidirectional Laminate(UD) and the characteristic length of Multidirectional Laminate(MD) around hole under the Uniform Tensial Strain. Two fracture mechanical concepts of the Waddoups-Eisenman-Kaminski(WEK) model based on the Linear Elastic Fracture Mechanics(LEFM) and the Whitney-Nuismer Model based on Point and Average Stress Criteria were applied. The characteristic length of a laminate with a hole is then obtained using the coefficient of stress reduction and the experimental results, and it can be utilized in predicting the stress level at which the specimen will fracture. The results of the fracture characteristics and the strength of the specimens having a hole in the center can be used as the important experimental data in the research branch of the mechanical fastening of laminated structures. The Ultrasonic scanning and the Acoustic Emission(AE) method were utilized in order to find out the initial defects and the fracture behavior, respectively.

  • PDF

Enhancing the ability of strain energy release rate criterion for fracture assessment of orthotropic materials under mixed-mode I/II loading considering the effect of crack tip damage zone

  • Khaji, Zahra;Fakoor, Mahdi
    • Steel and Composite Structures
    • /
    • 제44권6호
    • /
    • pp.817-828
    • /
    • 2022
  • In this study, considering dissipated energy in fracture process zone (FPZ), a novel criterion based on maximum strain energy release rate (SER) for orthotropic materials is presented. General case of in-plane loading for cracks along the fibers is assumed. According to the experimental observations, crack propagation is supposed along the fibers and the reinforcement isotropic solid (RIS) concept is employed as a superior model for orthotropic materials. SER in crack initiation and propagation phases is investigated. Elastic properties of FPZ are extracted as a function of undamaged matrix media and micro-crack density. This criterion meaningfully links between dissipated energy due to toughening mechanisms of FPZ and the macroscopic fracture by defining stress intensity factors of the damaged zone. These coefficients are used in equations of maximum SER criterion. The effect of crack initiation angle and the damaged zone is considered simultaneously in this criterion and mode II stress intensity factor is extracted in terms of stress intensity factors of damage zone and crack initiation angle. This criterion can evaluate the effects of FPZ on the fracture behavior of orthotropic material. Good agreement between extracted fracture limit curves (FLC's) and available experimental data proves the ability of the new proposed criterion.

The effects of matrix aging and residual stress changes on $Avimid^{(R)}$ K3B/IM7 laminates (수지 노화와 잔류응력 변화가 $Avimid^{(R)}$ K3B/IM7 복합재 적층에 미치는 영향)

  • Kim, Hyung-Won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • 제8권3호
    • /
    • pp.124-130
    • /
    • 2005
  • In this paper, the effects of matrix hygrothermal aging and residual stress changes on $Avimid^{(R)}$ K3B/IM7 laminates in $80^{\circ}C$ water were studied. The factors causing the $80^{\circ}C$ water to degradation of the laminates could be the degradation of the matrix toughness, the change in residual stresses. After 500 hours fully saturated aging of the neat resin, the weight gain was 1.55% increase with the diffusion coefficient $7{\times}10^{-6}m^2/s$ and the fracture toughness was decreased about 41%. After 100 hours fully saturated aging of the $[+45/0/-45/90]_s$ K3B/IM7 laminates in $80^{\circ}C$ water, the weight gain was 0.41% increase with the diffusion coefficient $1{\times}10^{-6}m^2/s$ and the loss of the microcracking fracture toughness was 43.8% of the original toughness. To see whether the residual stress influenced the fracture toughness, two ply $[90^{\circ}/0^{\circ}]$ laminates were put in $80^{\circ}C$ water from 2 hours to 8 hours. The changes in residual stress in 8 hours are less than 3MPa. Because the 3MPa change is not sufficient to degrade the laminates, the main factor to degrade the microcracking fracture toughness was the degradation of the matrix fracture toughness.

Stress-strain Model of Laterally Confined High-strength Concrete with the Compressive Fracture Energy (압축파괴에너지를 도입한 횡구속 고강도 콘크리트의 응력-변형률 모델)

  • Hong, Ki-Nam;Shim, Won-Bo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제23권1호
    • /
    • pp.54-62
    • /
    • 2019
  • In this paper, a stress-strain model for high-strength confined concrete is proposed using compressive fracture energy. In the compression test performed by author in Reference [6], an acrylic bar with strain gauges was embedded in the center of the specimen to measure the local strain distribution. It was found from the test that the local strain measurement by this acrylic rod is very effective. The local fracture zone length was defined based on the local strain distribution measured by the acrylic rod. Specifically, it was defined as the length where the local strain increases more than twice of the strain corresponding to maximum stress. In addition, the stress-strain relationship of confined concrete with compressive fracture energy is proposed on the assumption that the amount of energy absorbed by the compressive members subjected to the given lateral confining pressure is constant regardless of the aspect ratio and size. The proposed model predicts even results from other researchers accurately.