• 제목/요약/키워드: Fracture Stability

검색결과 421건 처리시간 0.023초

강선의 인장력과 추가 Half pin이 혼성외고정장치 시스템의 안정성에 미치는 영향 (Effects of Pre-tension and Additional Half-pin on Fracture Stability in Hybrid External Fixator System)

  • 김윤혁;이현근;박원만;오종건
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.389-392
    • /
    • 2004
  • It is clinically well known that pre-tension of wires increases the fracture stability in ring or hybrid external fixation. In some cases, additional half pin should be necessary to increase the stability when soft tissue impalement occurs during fixation. In this paper, the fracture stability of a hybrid external fixator system with different pre-tension effects and additional half-pins was analysed using FEM to investigate the effects of these pre-tension and half pin on the system stability quantitatively. 3-D finite element models of five different fixator frames were developed using by beam elements. In axial compression analysis, the fracture stiffness was increased maximally 62% as the pre-tension increased. In torsion analysis, in the other hand, there is little variations in the fracture stiffness. Additional half pin increased the system stiffness about 200 %. From the results, proper pre-tension and additional half pin would provide good methods to increase the fracture stability of the hybrid external fixator and provide more surgical options to minimize soft tissue damage at the fracture site.

  • PDF

Effect of perioperative buccal fracture of the proximal segment on postoperative stability after sagittal split ramus osteotomy

  • Lee, Sang-Yoon;Yang, Hoon Joo;Han, Jeong-Joon;Hwang, Soon Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권5호
    • /
    • pp.217-223
    • /
    • 2013
  • Objectives: Buccal fracture of the mandibular proximal bone segment during bilateral sagittal split ramus osteotomy (SSRO) reduces the postoperative stability. The primary aim of this study is to evaluate the effect of this type of fracture on bone healing and postoperative stability after mandibular setback surgery. Materials and Methods: Ten patients who experienced buccal fracture during SSRO for mandibular setback movement were evaluated. We measured the amount of bone generation on a computed tomography scan, using an image analysis program, and compared the buccal fracture side to the opposite side in each patient. To investigate the effect on postoperative stability, we measured the postoperative relapse in lateral cephalograms, immediately following and six months after the surgery. The control group consisted of ten randomly-selected patients having a similar amount of set-back without buccal fracture. Results: Less bone generation was observed on the buccal fracture side compared with the opposite side (P<0.05). However, there was no significant difference in anterior-posterior postoperative relapse between the group with buccal fracture and the control group. The increased mandibular plane angle and anterior facial height after the surgery in the group with buccal fracture manifested as a postoperative clockwise rotation of the mandible. Conclusion: Bone generation was delayed compared to the opposite side. However, postoperative stability in the anterior-posterior direction could be maintained with rigid fixation.

콘크리트 피복재의 단면파괴에 대한 신뢰성 해석 (Reliability Analysis for Fracture of Concrete Armour Units)

  • 이철응
    • 한국해안해양공학회지
    • /
    • 제15권2호
    • /
    • pp.86-96
    • /
    • 2003
  • 방파제의 경사면에 거치된 콘크리트 피복재의 단면파괴에 대한 신뢰성 해석을 수행하였다. 신뢰함수는 피복재의 흔들림 또는 동요의 크기를 정량적으로 나타내는 회전각의 함수로 유도되었다. 방파제 단면에 거치된 피복재의 재질적 성질 및 기하학적 형상과 관련된 확률변수들의 단면파괴에 미치는 영향 정도가 자세히 해석되었다. 또한 파고의 함수로 피복재 개개의 단면파괴에 대한 파괴확률이 산정 되었다. 마지막으로 Bernoulli과정과 허용파손율의 개념을 동시에 고려하여 피복재의 단면파괴가 어떻게 방파제 제체의 파괴확률로 이어지는가가 해석되었다. 허용파손율 개념은 본 연구에서 도입된 것으로, 허용파손율을 어떻게 정의하느냐에 따라 피복재의 단면파괴에 의하여 유발되는 방파제 제체의 파괴확률이 다르게 거동되는 것을 확인할 수 있었다 따라서 상대적으로 수심이 깊은 곳에 중량이 큰 콘크리트 피복재를 사용하여 방파제를 설계할 때는 수리학적 안전성뿐만 아니라 구조적 안전성도 중요하게 고려되어야 한다.

음향 방출법에 의한 파괴 인성치 측정 및 파괴 안정성 평가를 위한 연구 (Study of Fracture Toughness Measurement and Fracture Stability Evaluation by Acoustic Emission Method)

  • 이강용;백충헌
    • 대한기계학회논문집
    • /
    • 제13권1호
    • /
    • pp.96-104
    • /
    • 1989
  • 본 연구에서는 AE법에 의해 J$_{IC}$를 결정하는 것은 Takahashi등의 방법을 따르되 AE 실험결과를 토대로 이론을 전개하여 재료의 물성 곡선인 J-R곡선의 실험식과 재료 찢어짐 계수를 계산할 수 있는 실험식을 유도하며, 이렇게 구한 실험식을 불안정 파괴 조건에 적용하여 그 타당성을 검토한다.다.

A Study on Fracture Behavior and Impact Stability of Sintered Rare-earth Permanent Magnets

  • Li, Wei;Li, Anhua;Wang, Huijie;Dong, Shengzhi;Guo, Yongquan
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.790-791
    • /
    • 2006
  • The fracture behavior and mechanical characteristics of sintered rare-earth magnets were investigated. It shows that the fracture behavior and bending strength of the magnets obviously exhibit anisotropy. Sm-Co magnets tend to cleavage fracture in the close-packed (0001) plane or in the ($10\bar{1}1$) plane. The fracture mechanism of $Nd_2Fe_{14}B$ magnet mainly appears to be intergranular fracture. The anisotropy of fracture behavior and mechanical strength of sintered rare-earth magnets is caused mainly by the strong crystal-structure anisotropy and the grain alignment texture. The effects of Nd content, and Pr, Dy substitution on the impact stability of $Nd_2Fe_{14}B$ magnets were also reported.

  • PDF

Thermal Stability and Fracture Toughness of Epoxy Resins Modified with Epoxidized Castor Oil and Al2O3 Nanoparticles

  • Zhu, Lin;Jin, Fan-Long;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권8호
    • /
    • pp.2513-2516
    • /
    • 2012
  • This study examined the effects of the epoxidized castor oil (ECO) and $Al_2O_3$ content on the thermal stability and fracture toughness of the diglycidylether of bisphenol-A (DGEBA)/ECO/$Al_2O_3$ ternary composites using a range of techniques. The thermal stability of the composites was decreased by the addition of ECO and $Al_2O_3$ nanoparticles. The fracture toughness of the composites was improved significantly by the addition of ECO and $Al_2O_3$ nanoparticles. The composite containing 3 wt % $Al_2O_3$ nanoparticles showed the maximum flexural strength. Scanning electron microscopy (SEM) revealed tortuous cracks in the DGEBA/ECO/$Al_2O_3$ composites, which prevented deformation and crack propagation.

파괴역학에 근거한 철근콘크리트 보의 휨 파괴거동 (Flexural Fracture Behavior of Reinforced Concrete Beam Based on Fracture Mechanics Approach)

  • 어석홍;최덕진;홍기호;김희성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.149-154
    • /
    • 2002
  • An analytical fracture mechanics approach was used to investigate the fracture behavior of reinforced concrete beams. By use of this approach based on fracture mechanics concepts, the crack width and length as well as the strength and cracking stability of reinforced concrete beams were investigated. The results obtained from the analytical studies were also discussed in terms of the minimum reinforcement ratio and crack width specified in design code provisions. The analytical approach based on fracture mechanics concepts are very useful to predict the fracture behavior of reinforced concrete beams.

  • PDF

후방 십자 인대 급성 손상에서 일차 복원술의 결과 (The Results of Primary Repair in Acute Injuries of the Posterior Cruciate Ligament)

  • 이동철;백승희
    • Journal of Yeungnam Medical Science
    • /
    • 제18권1호
    • /
    • pp.101-111
    • /
    • 2001
  • 후방 십자 인대 손상에서 일차 복원술이 가능한 대퇴 부착부 파열과 경골 부착부 견열 골절환자를 대상으로 손상 부위와 동반 인대 손상 유무에 따른 후방 안정성과 주관적, 객관적 기능의 평가에서 Lysholm 기능 평가상 대퇴 부착부 손상군(85.3점)이 경골 부착부 견열 골절군(96.3점)에 비해 결과가 불량하였다(p<0.05). 그러나 단독 후방 십자 인대 손상군(91.1점)은 복합 인대 손상군(86.6점)에 비해 양호하였으나 통계적인 유의성은 없었다. 후방 십자 인대의 불안정성 정도는 후방 긴장성 사진과 KT 2000 슬관절계 검사상 대퇴 부착부 손상군보다 경골 견열 골절 손상군에서 나은 경향을 보이나 통계적인 유의성은 없었다. 또한 olecranization 시행은 후방 안정성에서 시행한 군이 나은 경향을 보여 심한 후방 불안정성이 있는 경우 수술 후 초기에 일시적인 후방 안정성에 도움을 줄 수 있을 것으로 생각된다.

  • PDF

Rock mechanics and wellbore stability in Dongfang 1-1 Gas Field in South China Sea

  • Yan, Chuanliang;Deng, Jingen;Cheng, Yuanfang;Yan, Xinjiang;Yuan, Junliang;Deng, Fucheng
    • Geomechanics and Engineering
    • /
    • 제12권3호
    • /
    • pp.465-481
    • /
    • 2017
  • Thermal effect has great influence on wellbore stability in Dongfang 1-1 (DF 1-1) gas field, a reservoir with high-temperature and high-pressure. In order to analyze the wellbore stability in DF1-1 gas field, the variation of temperature field after drilling was analyzed. In addition, the effect of temperature changing on formation strength and the thermal expansion coefficients of formation were tested. On this basis, a wellbore stability model considering thermal effect was developed and the thermal effect on fracture pressure and collapse pressure was analyzed. One of the main challenges in this gas field is the decreasing temperature of the wellbore will reduce fracture pressure substantially, resulting in the drilling fluid leakage. If the drilling fluid density was reduced, kick or blowout may happen. Therefore, the key of safe drilling in DF1-1 gas field is to predict the fracture pressure accurately.

Biepicondylar Fracture of the Humerus in an Adult Female: A Case Report

  • Seong, Minkyu;Choi, Jungyun;Yum, Jaekwang
    • Clinics in Shoulder and Elbow
    • /
    • 제19권4호
    • /
    • pp.249-251
    • /
    • 2016
  • iepicondylar fracture of the humerus is very rare in adults. To date, there have been limited evidence of this injury in the English literature. We report a case of a 65-year-old female with a biepicondylar fracture of the left distal humerus without dislocation. Open reduction and internal fixation with K-wires, cannulated screw, and suture anchor were performed. We obtained stability of the elbow and a satisfactory functional outcome. Because this type of injury is associated with varus and valgus instability, operative reduction and fixation are essential in order to gain stability and early recovery of normal function.