• Title/Summary/Keyword: Fracture Characteristic

Search Result 344, Processing Time 0.026 seconds

The Effect of Hole Size on the Failure Strength and Fracture Toughness in Polymer Matrix Composite Plates (Plastic기 복합재료의 파손강도 및 파괴인성에 미치는 원공크기의 영향)

  • Kim, Jeong-Gyu;Kim, Do-Sik
    • Korean Journal of Materials Research
    • /
    • v.3 no.2
    • /
    • pp.197-204
    • /
    • 1993
  • Abstract The effects of the hole size and the specimen width on the fracture behavior of several fabric composite plates are experimentally investigated in tension. Tests are performed on plain woven glass/ epoxy, plain woven carbon/epoxy and satin woven glass/polyester specimens with a circular hole. It is shown in this paper that the characteristic length according to the point stress criterion depends on the hole size and the specimen width. An excellent agreement is found between the experimental results and the analytical predictions of the modified failure criterion. The notched strength increase with an increase in the damage ratio, which is explained by a stress relaxation due to the formation of damage zone. When the unstable fracture occurred, the critical crack length equivalent for the damage zone is about twice the characteristic length. The critical energy release rate $G_c$ is independent of hole size for the same specimen width. The variation of $G_c$ according to the material system, fiber volume fraction and specimen width relates to the notch sensitivity factor. $G_c$ increases with a decrease in the notch sensitivity factor, which can be explained by a stress relaxation due to the increase of damage zone.

  • PDF

Analysis of Characteristic Evaluation of Microdrilling for the Cemented Carbides Materials (초경합금 소재 마이크로드릴의 가공특성 평가)

  • 김건회
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.6
    • /
    • pp.52-59
    • /
    • 2002
  • Resently, reduction of industrial products in size and weight has increased by the application of micro-drill for gadgets of high precision and gave rise to a great interest in a micro-drilling. Due to the lack of tool stiffness and the chip packing, micro-drilling requires not only the robust tool structure which has not affected by the vibration, but also the effective drilling methods designed to prevent tool fracture from cutting troubles. Firstly, this paper presents a optimum characteristic evaluation method of 0.15mm microdrill in consideration of new manufacturing processes for improving the product rate and extend the tool life, and secondly suggest between microdrilling characteristic properties of tool md evaluation of workpiece quality through experiment.

Evaluation of Fatigue Life Characteristic of a Real Waterwork Pipe Using the Probability Density Function (확률밀도함수를 이용한 상수도 실 배관의 피로수명 특성 평가)

  • Choi J.H.;Park J.S.;Seok C.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1691-1694
    • /
    • 2005
  • The fatigue characteristic of a material or a structure is derived from fatigue tests of standard specimens. However test results of standard specimens are very different from those of real structures or components. Therefore, to calculate more accurate fatigue life, the geometrical effect and surface condition must be considered by comparing test results of standard specimens with those of real structures or components. Thus the object of this paper is to evaluate the fatigue characteristic of a real waterwork pipe by conducting fatigue tests with standard specimens and non-standard(plate-shaped) specimens of base metal and weld metal. Also, to evaluate fatigue characteristic based on life distribution, statistical fatigue characteristic was analyzed by the normal distribution and related data of P-S-N curve.

  • PDF

Study of Failure Criterion of Hole-Notched Plain-Weave Carbon Fiber Reinforced Plastic (CFRP) Composites (홀 노치를 포함한 평직 탄소섬유강화플라스틱의 파괴기준 연구)

  • Kim, Sang-Young;Geum, Jin-Hwa;Koo, Jae-Mean;Seok, Chang-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.4
    • /
    • pp.481-486
    • /
    • 2010
  • Recently, carbon fiber reinforced plastic (CFRP) have been used in various fields because of its high specific modulus, and chemical properties. Most products in which CFRP composites are used are manufactured by joining the product components by bolts or pins. Holes for bolts and pins decrease the strength of the components because these holes act as notches in the structures. In this study, the fracture strength of CFRP plain-weave composite plates containing holes is experimentally investigated to examine the effects of hole-size and specimen width on notched tensile strength. The results show that the characteristic length considered in the point stress criterion depends on the hole size and specimen width. There exists a certain relation between notched tensile strength and characteristic length. Fracture criterion is redefined on basis of this relation.

A Study on Friction-induced Surface Fracture Behaviors of Carboxylic Acid Modified Styrenic Thermoplastic Elastomer as Additives (첨가제에 따른 변성 스티렌계 열가소성 엘라스토머의 마찰에 의한 표면 파괴 거동 연구)

  • Jeon, Jun-Ha;Park, Sang-Min;Lee, Jin- Hyok;Um, Gi-Yong
    • Journal of Adhesion and Interface
    • /
    • v.16 no.3
    • /
    • pp.95-100
    • /
    • 2015
  • In this work, we observed the effect of silica, zinc oxide, zinc ion coated silica on carboxylic acid modified styrenic thermoplastic elastomer (m-TPS) film for friction-induced surface fracture. m-TPS film added general silica showed poor mechanical properties, anti-abrasion and friction-induced surface fracture, caused by strong filler-filler interaction of silica. In case of m-TPS films added zinc oxide or zinc ion coated silica, mechanical properties, anti-abrasion and friction-induced surface fracture were improved due to forming ionic cluster between carboxylic acid group of m-TPS and zinc ion. Ionic cluster were confirmed by FT-IR analysis that observed zinc carboxylated group stretch peak at $1550{\sim}1650cm^{-1}$.

Acoustic Emission Characteristics during fracture Process of Glass Fiber/Aluminum Hybrid Laminates (유리섬유/알루미늄 혼합 적층판의 파괴과정과 음향방출 특성)

  • Woo, Sung-Choong;Choi, Nak-Sam
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.274-286
    • /
    • 2005
  • Fracture behaviors and acoustic emission (AE) characteristics of single-edge-notched monolithic aluminum plates and glass fiber/aluminum hybrid laminate plates have been investigated under tensile loads. AE signals from monolithic aluminum could be classified into two different types: signals with low frequency band and high frequency band. High frequency signals were detected in the post stage of loading beyond displacement of 0.45mm. For glass fiber/aluminum laminates, AE signals with high amplitude and long duration were additionally confirmed on FFT frequency analysis, which corresponded to macro-crack propagation and/or delamination between A1 and fiber layers. On the basis of the above AE analysis and fracture observation with optical microscopy and ultrasonic T scan, characteristic features of AE associated with fracture processes of single-edge-notched glass fiber/aluminum laminates were elucidated according to different fiber ply orientations.

Enhancing Box Sign : Enhancement Pattern of Acute Osteoprotic Compression Fracture

  • Kim, Choong-Hyo;Park, Jae-Hyo;Chung, Sang-Ki;Kim, Ki-Jeong;Bang, Jae-Seung;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.528-531
    • /
    • 2009
  • Objective : Although gadolinium enhancement of compression fractures is well known, the enhancement pattern of the acute stage of a fracture is not completely understood. Here, we investigated the enhancement pattern of acute vertebral compression fractures (VCFs). Methods : We conducted a retrospective study of patients with acute osteoporotic VCFs admitted to hospital between January 2004 and December 2005. The demographic details, stage of the fracture, management data, and results were analyzed. There were nine men and 22 women, and the mean age was 71 years (range, 53-92 years). According to the onset of pain, patients were divided into the following four groups : Group I (less than 3 days), Group II (4-7 days), Group III (8-14 days), and Group IV (14-30 days). Results : All patients had central low-signal intensity of the nonenhancing part of vertebral bodies on T1 images. Enhancing box sign (EBS) was seen 7 days of VCF development. After 7 days of onset (Groups III and IV), patch or Kummell's enhancements occurred. EBS has been statistically correlated with stage of compression fracture (Pearson's correlation = -0.774). However, EBS had no statistically significant correlation with prognosis in our study (Pearson's correlation = 0.059). Conclusion : EBS represents a characteristic sign 7 days of VCF development.

Preliminary report of March Fractures in Infantry Soldiers of Korea - About 15 (19cases) march fracture patients - (한국 보병에서 발생한 중족골 행군골절 양상의 예비적 보고)

  • Bae, Young-Jae;Yoon, Sung-Il
    • Journal of Korean Foot and Ankle Society
    • /
    • v.2 no.2
    • /
    • pp.57-63
    • /
    • 1998
  • Stress or march fractures among military personnel, especially recruits, has been appreciated for many years. According to the classical references, the second metatarsal was one of the first sites identified as a focus for march fractures and radiological evidence of fracture appeared as late as several weeks. The purpose of this study was to document the clinical feature of march fractures in Korean infantry soldiers. From 1997 to 1998, at one infantry medical company of OO infantry corps in Korea, 15 (19cases) patients with march fracture were detected among infantry soldiers. There were some different finding in the fracture site and its clinical features from the previous foreign reports. 1. There were pain and local swelling in all cases as clinical manifestation. By physical examination, direct point tenderness on the location of the fractured metatarsal shaft was characteristic. 2. On roentgenographic examination, cortical fissuring or break was seen one week after onset of symptoms and external callus was seen from two weeks or at the least four weeks. Oblique view was more useful than AP view in the diagnosis of march fractures. 3. The third metatarsal was the most frequently involved site(7 cases, 48%). and the second metatarsal was Jess frequent(3 cases, 20%). This difference of frequent site with previous reports might be attributed to the relatively long shaft of the third metatarsal, but should be analyzed in further study. 4. The incidence of the development of march fracture was 1 per 104 infantry soldiers.

  • PDF

Diagnostic performance of stitched and non-stitched cross-sectional cone-beam computed tomography images of a non-displaced fracture of ovine mandibular bone

  • Farzane Ostovarrad;Sadra Masali Markiyeh;Zahra Dalili Kajan
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.375-381
    • /
    • 2023
  • Purpose: This study assessed the diagnostic performance of stitched and non-stitched cross-sectional cone-beam computed tomography (CBCT) images of non-displaced ovine mandibular fractures. Materials and Methods: In this ex vivo study, non-displaced fractures were artificially created in 10 ovine mandibles (20 hemi-mandibles) using a hammer. The control group comprised 8 hemi-mandibles. The non-displaced fracture lines were oblique or vertical, <0.5 mm wide, 10-20 mm long, and only in the buccal or lingual cortex. Fracture lines in the ramus and posterior mandible were created to be at the interface or borders of the 2 stitched images. CBCT images were obtained from the specimens with an 80 mm×80 mm field of view before and after fracture induction. OnDemand software (Cybermed, Seoul, Korea) was used for stitching the CBCT images. Four observers evaluated 56 (28 stitched and 28 non-stitched) images to detect fracture lines. The diagnostic performance of stitched and non-stitched images was assessed by calculating the area under the receiver operating characteristic curve (AUC). Sensitivity and specificity values were also calculated (alpha=0.05). Results: The AUC was calculated to be 0.862 and 0.825 for the stitched and non-stitched images, respectively (P=0.747). The sensitivity and specificity were 90% and 75% for the non-stitched images and 85% and 87% for the stitched images, respectively. The inter-observer reliability was shown by a Fleiss kappa coefficient of 0.79, indicating good agreement. Conclusion: No significant difference was found in the diagnostic performance of stitched and non-stitched cross-sectional CBCT images of non-displaced fractures of the ovine mandible.

Diagnostic Performance of Diffusion-Weighted Steady-State Free Precession in Differential Diagnosis of Neoplastic and Benign Osteoporotic Vertebral Compression Fractures: Comparison to Diffusion-Weighted Echo-Planar Imaging

  • Shin, Jae Ho;Jeong, Soh Yong;Lim, Jung Hyun;Park, Jeongmi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.154-161
    • /
    • 2017
  • Purpose: To evaluate the diagnostic performance of diffusion-weighted steady-state free precession (DW-SSFP) in comparison to diffusion-weighted echo-planar imaging (DW-EPI) for differentiating the neoplastic and benign osteoporotic vertebral compression fractures. Materials and Methods: The subjects were 40 patients with recent vertebral compression fractures but no history of vertebroplasty, spine operation, or chemotherapy. They had received 3-Tesla (T) spine magnetic resonance imaging (MRI), including both DW-SSFP and DW-EPI sequences. The 40 patients included 20 with neoplastic vertebral fracture and 20 with benign osteoporotic vertebral fracture. In each fracture lesion, we obtained the signal intensity normalized by the signal intensity of normal bone marrow (SI norm) on DW-SSFP and the apparent diffusion coefficient (ADC) on DW-EPI. The correlation between the SI norm and the ADC in each lesion was analyzed using linear regression. The optimal cut-off values for the diagnosis of neoplastic fracture were determined in each sequence using Youden's J statistics and receiver operating characteristic curve analyses. Results: In the neoplastic fracture, the median SI norm on DW-SSFP was higher and the median ADC on DW-EPI was lower than the benign osteoporotic fracture (5.24 vs. 1.30, P = 0.032, and 0.86 vs. 1.48, P = 0.041, respectively). Inverse linear correlations were evident between SI norm and ADC in both neoplastic and benign osteoporotic fractures (r = -0.45 and -0.61, respectively). The optimal cut-off values for diagnosis of neoplastic fracture were SI norm of 3.0 in DW-SSFP with the sensitivity and specificity of 90.4% (95% confidence interval [CI]: 81.0-99.0) and 95.3% (95% CI: 90.0-100.0), respectively, and ADC of 1.3 in DW-EPI with the sensitivity and specificity of 90.5% (95% CI: 80.0-100.0) and 70.4% (95% CI: 60.0-80.0), respectively. Conclusion: In 3-T MRI, DW-SSFP has comparable sensitivity and specificity to DW-EPI in differentiating the neoplastic vertebral fracture from the benign osteoporotic vertebral fracture.