• Title/Summary/Keyword: Fraction images

Search Result 216, Processing Time 0.028 seconds

Effects of Entrained Air on the Characteristics of a Small Screw-type Centrifugal Pump (공기 흡입이 소형 스크류식 원심펌프의 특성에 미치는 영향)

  • Kim, You-Taek;Tanaka, Kazuhiro;Lee, Young-Ho;Matsumoto, Yoichiro
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.37-44
    • /
    • 1999
  • In a screw-type centrifugal pump, the pump head deteriorates from single-phase flow to the choke due to an increased air entrainment at a wide tip clearance compared to that of a narrow tip clearance. Moreover, at a narrow tip clearance, the pump head became partially higher in a two-phase flow than that of a single-phase flow near the best efficiency point in low void fraction region. Therefore, we observed the internal flow pattern by using a stroboscope and we measured the mean size of bubbles from the images obtained with a high speed camera. Then, we investigated the influences of the mean size of bubbles, tip clearances and flow patterns on pump performance.

  • PDF

Test Application of KOMPSAT-2 to the Detection of Microphytobenthos in Tidal Flats

  • Won Joong-Sun;Lee Yoon-Kyung;Choi Jaewon
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.249-252
    • /
    • 2005
  • Microphytobenthos bloom from late January to early March in Korean tidal flats. KOMPSAT-2 will provide multi-spectral images with a spatial resolution of 4 m comparable with IKONOS. Using IKONOS and Landsat data, algal mat detection was tested in the Saemangeum area~ Micro-benthic diatoms are abundant and a major primary product in the tidal flats. A linear spectral unmixing (LSU) method was applied to the test data. LSU was effective to detect algal mat and the classified algal mat fraction well correlated with NDVI image. Fine grained upper tidal flats are generally known to be the best environment for algal mat. Algal mat thriving in coarse grained lower tidal flats as well as upper tidal flats were reported in this study. A high resolution multi-spectral sensor in KOMPSAT-2 will provide useful data for long-term monitoring of microphytobenthos in tidal flats.

  • PDF

Shear-induced Migration of Brownian Suspension in a Pressure-driven Microchannel Flow

  • Kim Y.W.;Jin S.W.;Kim S.W.;Yoo J.Y.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.84-85
    • /
    • 2004
  • Experimental study was conducted to characterize shear-induced lateral migration of $1.0-{\mu}m-diameter$ Brownian particles flowing through a rectangular microchannel which can be used to deliver small amount of liquids, drugs, biological agents and particles in microfluidic devices. Measurements were obtained by using a mercury lamp with a light of 532-nm wavelength, an inverted epi-fluorescence microscope, and a cooled CCD camera to record particle images. Peclet number was used as a parameter to assess the lateral distribution of the particles at a fixed volume fraction of $0.1\%$. It was shown that as Pe increased, particles were moved toward the centerline of the channel, which is in good agreement with previous studies.

  • PDF

Lane Detection Using Biased Discriminant Analysis

  • Kim, Tae Kyung;Kwak, Nojun;Choi, Sang-Il
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.3
    • /
    • pp.27-34
    • /
    • 2017
  • We propose a cascade lane detector that uses biased discriminant analysis (BDA) to work effectively even when there are various external factors on the road. The proposed cascade detector was designed with an existing lane detector and the detection module using BDA. By placing the BDA module in the latter stage of the cascade detector, the erroneously detected results by the existing detector due to sunlight or road fraction were filtered out at the final lane detection results. Experimental results on road images taken under various environmental conditions showed that the proposed method gave more robust lane detection results than conventional methods alone.

Superparamagnetic Gd- and Mn-substituted Magnetite Fluids Applied as MRI Contrast Agents

  • Kim, Jong-Hee;Lee, Chang-Hyun;Lee, Sang-Kuk
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.1305-1308
    • /
    • 2009
  • The experimental particle samples included ($Mn_{0.1}Fe_{0.9}$)O-$Fe_2O_3$ and FeO-($Gd_{0.1}Fe_{0.9}$)$_2O_3$ with $Mn^{2+}\;and\;Gd^{3+}$ substitutions in inverse spinel $Fe_3O_4$. A lecithin surfactant was adsorbed onto the magnetic particles by ultrasonication. The samples prepared showed excellent dispersibility at the mean size of 13 nm; their saturation magnetization values were 63 emu/g for the bare and Mn-substituted magnetites, and 56 emu/g for the Gd-substituted magnetite. The crystal structure of the substituted magnetites was very similar to that of the bare magnetite, due to a small amount of 0.1 mole fraction substituted in synthesizing the magnetite. The magnetite fluids, according to T2-weighted MR images, effectively diminished the signal intensity in the liver and spleen of Sprague-Dawley rats.

An Experimental Study on the Combustion Characteristics with Hydrogen Enrichment in a Dump Combustor (수소 혼합에 따른 덤프 연소기내의 연소 특성에 관한 실험적 연구)

  • Kim, Dae-Hee;Hong, Jung-Goo;Shin, Hyun-Dong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2977-2983
    • /
    • 2008
  • The combustion characteristics of a partially premixed flame in a dump combustor were studied to determine the effects of hydrogen enrichment in propane. Bluff-body was used for flame stabilization. Fuel mixtures containing a hydrogen mole fraction ranging from 0.1 to 0.5 were burnt at ambient pressure within a quartz chamber. Tests were carried out keeping the total reactant flow rate by adjusting the fuel and air flow rates. The fluctuations of pressure were measured by piezoelectric pressure sensor. The instantaneous flame structure and OH chemiluminescence images were described by High-speed Intensified Charged Coupled Device (HICCD) camera and Intensified Charged Coupled Device (ICCD) camera. The present results show that hydrogen enrichment in fuel changed the location of primary reaction zone from inner recirculation zone to turbulent shear layer and pressure signal. The reason is that chemical aspects take precedence over flow aspects in the hydrogen-enriched flame.

  • PDF

Wetting Behavior and Evaporation Characteristics of Nanofluid Droplets on Glass Surfaces (나노유체 액적의 젖음거동 및 증발 특성)

  • Shin, Dong-Hwan;Lee, Seong-Hyuk
    • Journal of ILASS-Korea
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2012
  • This study investigates experimentally evaporation characteristics of nanofluid droplets containing 50 nm alumina($Al_2O_3$) particles and the wettability changes on a hydrophilic glass surfaces. From the captured digital images by using a CMOS camera and a magnifying lens, we examined the effect of particle concentration on droplet evaporation rate which can be indirectly deduced from the measured droplet volumes varying with time. In particular, with the use of a digital image analysis technique, the present study measured droplet perimeters and the contact angles to study the wetting dynamics during evaporating process. In addition, we compared the measured total evaporation time with theoretically estimated values. It was found that as the volume fractions of nanofluid increased, the total evaporation time and the initial contact angles decreased, while the droplet perimeters increased.

Performance Characteristics of MicroPET R4 Scanner for Small Animal Imaging (소동물 영상을 위한 MicroPET R4스캐너의 특성평가)

  • Lee, Byeong-Il;Lee, Jae-Sung;Kim, Jin-Su;Lee, Dong-Soo;Choi, Chang-Un;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Purpose: Dedicated animal PET is useful equipment for the study of new PET tracer. recently, microPET R4 was installed in the Korea institute of radiology and medical science. In this study, we measured the characteristics of scanner. Materials and methods: Resolution was measured using a line source (F-18:65 ${\mu}Ci$, inner diameter: 0.5 mm). The line source was put in the axial direction and was moved from the center of field of view to outside with 1 mm interval. PET images were reconstructed using a filtered back-protection and ordered subset expectation maximization. line source (16.5 ${\mu}Ci$, 78 mm) was put on the tenter of axial direction to measure the sensitivity when the deadtime was under 1%. Images were acquired during 4 minutes respectively from center to 39 mm outward. Delayed count was subtracted from total count and then decay was corrected for the calculation of sensitivity. Noise equivalent count ratio and scatter fraction were calculated using cylindrical phantom. Results: Spatial resolution of reconstructed image using filtered back-projection was 1.86 mm(radial), 1.95 mm(tangential), 1.95 mm(axial) in the tenter of field of view, and 2.54 mm, 2.8 mm, 1.61 mm in 2 cm away from the center respectively. Sensitivity was 2.36% at the center of transaxial field of view. Scatter fraction was 20%. Maximal noise equivalent count ratio was 66.4 kcps at 242 kBq/mL. Small animal images were acquired for confirmation of performance. Conclusion: Performance characteristics of microPET R4 were similar with reported value. So this will be a useful tool for small animal imaging.

Interpretation of Receiver Operating Characteristics (ROC) (ROC(receiver operating characteristics) 해석)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.30 no.3
    • /
    • pp.155-158
    • /
    • 2000
  • The purpose of this paper is to explain the making procedure and the usage of receiver operating characteristic (ROC) curve for interpretation of radiographic images. The conventional radiograms obtained after the creation of the lesions in the acrylic plates and were enhanced in color. The observer were informed of which tooth to examine, the 'a priori' probability of a lesion present and the approximate diameter of the lesions. The two groups of films were interpreted separately by the same observer using the same rating scale. The following rating scale was used: A; definitely no lesion, B; probably no lesion, C; not sure, D; probably a lesion, and E; definitely a lesion. In analysis, for each observer the diagnostic results in terms of true positive (TP) and false positive (FP) decisions were plotted on a graph. The lowest point on the graph represents the TP and FP when only decisions designated as E according to the rating scale are included. The next point shows the TP and FP values when diagnoses designated as D are added and so forth. By connecting such plot points, a receiver operating characteristic (ROC) curves is obtained. The area under the curve represents the diagnostic accuracy resulting from a diagnostic performance at pure chance level and a value of 1.0 at perfect performance. This method has been known as an useful method to detect the minute difference for each radiographic technic, each observer and for the different lesion depths.

  • PDF

A Study on Evaporative Characteristics of Multi-component Mixed Fuels Using Mie Scattered Light and Shadowgraph Images (Mie 산란광법 및 Shadowgraph법을 이용한 다성분 혼합연료의 증발특성연구)

  • Yoon, Jun-Kyu;Myong, Kwang-Jae;Jiro Senda;Fujimoto Hajime;Cha, Kyung-Ok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.7 s.250
    • /
    • pp.682-691
    • /
    • 2006
  • This study was conducted to assess the effect of mixed fuel composition and mass fraction on spray inner structure in evaporating transient spray under the various ambient conditions. Spray structure and spatial distribution of liquid phase concentration are investigated using a thin laser sheet illumination technique on the multi-component mixed fuels. A pulsed Ar+ laser was used as a light source. The experiments were conducted in a constant volume vessel with optical access. Fuel was injected into the vessel with electronically controlled common rail injector. Used fuel contain $i-octane(C_8H_{18}),\;n-dodecane(C_{12}H_{26})$ and $n-hexadecane(C_{16}H_{34})$ that are selected as low-, middle- and high-boiling point fuel, respectively. Experimental conditions are 25Mpa, 42MPa, 72MPa and 112MPa in injection pressure, $5kg/m^3,\;15kg/m^3\;and\;20kg/m^3$ in ambient gas density, 400K, 500K, 600K and 700K in ambient gas temperature, 300K and 368K in fuel temperature, and different fuel mass fraction. Experimental results indicate that the more high-boiling point component, the longer the liquid phase it were closely related to fuel physical properties, but injection pressure had no effect on. And there was a high correlation between the liquid phase length and boiling temperature at 75% distillation point.