• Title/Summary/Keyword: Four-point flexure strength

Search Result 15, Processing Time 0.023 seconds

THE EFFECTS OF METAL SURFACE TREATMENT ON BOND STRENGTH BETWEEN RESIN AND METAL INTERFACE OF RESIN VENEERED CROWN (레진전장관의 금속면 처리방법 레진과 금속간 접착강도에 미치는 영향)

  • Choi Nak-Joon;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.4
    • /
    • pp.471-483
    • /
    • 1994
  • The purpose of this experiment was to determine the effects of various surface treatments on veneering resin to metal bond for Ni-Cr alloy. The metal surfaces were treated as follows, Group 1 : Ground with carborudum point and followed by silicoating Group 2 : Sandblasted with $50{\mu}m$ aluminum oxide and followed by silicoating Group 3. Sandblasted with $250{\mu}m$ aluminum oxide and followed by silicoating Group 4 : Beaded with $200{\mu}m$ retention structures and followed by silicoating Group 5 : Silicoated in as cast condition Group 6. Beaded with $200{\mu}m$ retention structures only All specimens were veneered with resin. Each group was consisted of 20 specimens. 10 specimens were storaged in $37^{\circ}C$ water for 3 days and the rest 10 specimens were thermocycled 1000 times at temperature of $5^{\circ}C\;to\;55^{\circ}C$. The effects of various surface treatments on the bond strength between resin and metal interface were studied by means of four-point flexure test. The specimens which bad been ground with carborundum point. sandblasted with $50{\mu}m$ and $250{\mu}m$ aluminum oxide. beaded with $200{\mu}m$ retention structures and not been treated were observed with SEM. The following results were obtained 1. The bond strength of groups 2, 3, 4 and 6 were higher than the that of groups 1 and 5 (p<0.05) in the case of being storaged in $37^{\circ}C$ water for 3 day and there was no statistically significant difference in bond strength among groups 2, 3, 4 and 6. and between groups 1 and 5 (p>0.05). 2. The bond strength of the case of being thermocycled decreased in the following orders : groups 2, group 4, group 3, group 6, group 1, group 5 and there was no statistically significant difference in bond strength among groups 2, 3 and 4, between groups 1 and 5 (p>0.05). 3. A statistical difference in bond strength of each group between storaged and being thermocycled was demonstrated for group 5 (p<0.05). 4. The treated surfaces of groups 2, 3 and 4 had more fine undercut than that of groups 1 and 5 with SEM.

  • PDF

A Study of Mode II Interlaminar Fracture for CFRP Laminate Composite using the 4-point Bending CNF Specimen (4점굽힘 CNF 시험편을 이용한 CFRP적층 복합재 모드 II 층간파괴)

  • Kwon, Oh-Heon;Kang, Ji-Woong;Tae, Hwan-Jun;Hwang, Yeong-Yeun;Yun, Yu-Seung
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.34-39
    • /
    • 2010
  • Unidirectional Carbon Fiber Reinforced Plastics (CFRP) are advanced materials which combine the characteristics of the light weight, high stiffness and strength. For those reasons, the use of the unidirectional CFRP has increased in jet fighters, aerospace structures. However, unidirectional CFRP composites have a lot of problems, especially delamination, compared with traditional materials such as steels and aluminums, and so forth. Therefore, the interlaminar fracture toughness for a laminate CFRP composite is very important. In this study, The mode II interlaminar fracture toughness was measured by using center notched flexure(CNF) test specimen. The CNF specimens using unidirectional carbon prepreg were fabricated by a hot-press with the gage pressure and temperature controller. And three kinds of a/L ratio was applied to these specimens. Here, we discuss the relations of the crack growth and the mode II interlaminar fracture under the four point bending CNF test. From the results, we shows that mode II interlaminar was occurred when the more $a_0$/L ratio, the less load. And $G_{IIC}$ also were obtained as 5.33, 2.9 and $0.58kJ/m^2$ according to $a_0$/L ratio=0.2, 0.3 and 0.4.

Structural efficiency of various strengthening schemes for cold-formed steel beams: Effect of global imperfections

  • Dar, M. Adil;Subramanian, N.;Dar, A.R.;Majid, Muheeb;Haseeb, Mohd;Tahoor, Mugees
    • Steel and Composite Structures
    • /
    • v.30 no.4
    • /
    • pp.393-403
    • /
    • 2019
  • Cold-formed steel (CFS) has a great potential to meet the global challenge of fast-track and durable construction. CFS members undergo large buckling instabilities due to their small wall thickness. CFS beams with corrugated webs have shown great resistance towards web buckling under flexure, when compared to the conventional I-sections. However, the magnitude of global imperfections significantly affects the performance of CFS members. This paper presents the first attempt made to experimentally study the effect of global imperfections on the structural efficiency of various strengthening schemes implemented in CFS beams with corrugated webs. Different strengthening schemes were adopted for two types of beams, one with large global imperfections and the other with small imperfections. Strength and stiffness characteristics of the beams were used to evaluate the structural efficiency of the various strengthening schemes adopted. Six tests were performed with simply supported end conditions, under four-point loading conditions. The load vs. mid-span displacement response, failure loads and modes of failure of the test specimens were investigated. The test results would compensate the lack of experimental data in this area of research and would help in developing numerical models for extensive studies for the development of necessary guidelines on the same. Strengthening schemes assisted in enhancing the member performance significantly, both in terms of strength and stiffness. Hence, providing an economic and time saving solution to such practical structural engineering problems.

Shear strengthening of seawater sea-sand concrete beams containing no shear reinforcement using NSM aluminum alloy bars

  • Yasin Onuralp Ozkilic;Emrah Madenci;Ahmed Badr;Walid Mansour;Sabry Fayed
    • Steel and Composite Structures
    • /
    • v.51 no.2
    • /
    • pp.153-172
    • /
    • 2024
  • Due to the fast development of constructions in recent years, there has been a rapid consumption of fresh water and river sand. In the production of concrete, alternatives such as sea water and sea sand are available. The near surface mounted (NSM) technique is one of the most important methods of strengthening. Aluminum alloy (AA) bars are non-rusting and suitable for usage with sea water and sand concrete (SSC). The goal of this study was to enhance the shear behaviour of SSC-beams strengthened with NSM AA bars. Twenty-four RC beams were cast from fresh water river sand concrete (FRC) and SSC before being tested in four-point flexure. All beams are the same size and have the same internal reinforcement. The major factors are the concrete type (FRC or SSC), the concrete degree (C25 or C50 with compressive strength = 25 and 50 MPa, respectively), the presence of AA bars for strengthening, the direction of AA bar reinforcement (vertical or diagonal), and the AA bar ratio (0, 0.5, 1, 1.25 and 2 %). The beams' failure mechanism, load-displacement response, ultimate capacity, and ductility were investigated. Maximum load and ductility of C25-FRC-specimens with vertical and diagonal AA bar ratios (1%) were 100,174 % and 140, 205.5 % greater, respectively, than a matching control specimen. The ultimate load and ductility of all SSC-beams were 16-28 % and 11.3-87 % greater, respectively, for different AA bar methods than that of FRC-beams. The ultimate load and ductility of C25-SSC-beams vertically strengthened with AA bar ratios were 66.7-172.7 % and 89.6-267.9 % higher than the unstrengthened beam, respectively. When compared to unstrengthened beams, the ultimate load and ductility of C50-SSC-beams vertically reinforced with AA bar ratios rose by 50-120 % and 45.4-336.1 %, respectively. National code proposed formulae were utilized to determine the theoretical load of tested beams and compared to matching experimental results. The predicted theoretical loads were found to be close to the experimental values.

The Flexural and Shear Behaviors of Steel-PSC Mixed Structural System with Front-Rear Plate Connection (전·후면판 공용방식 접합부를 갖는 강-PSC 혼합구조의 휨 및 전단거동)

  • Lho, Byeong-Cheol;Cho, Sung-Yong;Park, Hyun-Chul;Kim, Mun-Kyum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.201-212
    • /
    • 2007
  • This study presents experimental results of Steel-PSC mixed structural system having front-rear plate connection between Steel and Prestressed Concrete. Two kinds of Steel-PSC mixed structural system of 5.4m length were tested to evaluate flexural behaviors under four point loading, and 4 kinds of specimens with and without prestressing force at R & L type connection were tested to observe the shear behavior. Based on the test results of load-deflection curves and failure modes of specimens, it is found that the proposed L shape connection with front-rear plate connection between Steel and Prestressed Concrete has higher strength and stiffness. From the study, Steel-PSC mixed structural system with L shaped connection has a better structural performance in connection part.