• 제목/요약/키워드: Foundation scouring

검색결과 17건 처리시간 0.024초

Fill Dam의 방수로모형실험에 관한 고찰 (A Study on Model Test for Spilway of Fill Dam)

  • 강병익
    • 한국농공학회지
    • /
    • 제12권4호
    • /
    • pp.2090-2123
    • /
    • 1970
  • This paper is a report on the research of experimental model test of Andong Fill Dam, which has been planned by the Government of Korea as a project, of its over-flowing capacity in spillway, creation of minus pressure and structure of anti-water impulse in over-flow weir. Andong Fill Dam is one of the project of master development plant for water resources, locating at Nakdong River side of Korea, and is aimed to have a multi-purpose dam for flood-control, irrigation, water power, urban and industrial water supply. This dam is planned to erect in fill-dam type due to the improper soil foundation and condition for concrete dam. The refore for the proper and advantageous points, this is designed as center core fill dam. By a model minimized of Andong Fill Dam, held an experimental model test on water quentity of reservir, discharges of overflow part, low pressure and anti-water impulse of overflow part, which was conducted an experiment by flowing aspects through each section of spillway to find the changes of water pressure and that of water level, and corrected the section of each part in order to conduct a check on the creation of minus pressure not to be over acted to the allowable bundary of the section structure; and for the prevention of concentated scouring at the down stream side of flow.

  • PDF

세굴에 기인한 해상풍력터빈 펜타팟 석션버켓 지지구조물의 극한한계상태 위험도 평가 (Ultimate Limit State Risk Assessment of Penta Pod Suction Bucket Support Structures for Offshore Wind Turbine due to Scour)

  • 김영진;;김동현
    • 한국해안·해양공학회논문집
    • /
    • 제33권6호
    • /
    • pp.374-382
    • /
    • 2021
  • 5.5 MW 해상풍력터빈을 위해 새로 개발된 펜타팟 석션버켓 지지구조물의 극한한계상태 위험도 평가를 진행하였다. 유의파고, 유의파 주기, 조류속 등 해양 환경조건을 고려한 세굴확률을 위험(hazard)으로 산정하였다. 석션버켓 지지구조물 기초의 극한한계상태 파괴기준을 적용하여 세굴 깊이에 따른 취약도를 산정하였다. 극한한계상태는 기초구조물의 지지력을 이용하여 정의하였다. 해저드와 취약도를 이용하여 펜타팟 석션버켓의 위험도를 산정하였다.

교량 우물통 기초의 세굴피해 평가를 위한 고유진동수 측정 (Natural Frequency Measurement for Scour Damage Assessment of Caisson Pier)

  • ;고석준;정경자;이주형;유민택;김성렬
    • 한국지반공학회논문집
    • /
    • 제37권11호
    • /
    • pp.51-60
    • /
    • 2021
  • 하천의 세굴은 교각 주변의 흙을 침식시켜 교각의 횡방향 지지력을 저감시키고 구조물의 건전도를 저하시키게 된다. 본 연구에서는 세굴이 구조물의 건전도에 미치는 영향을 살펴보고자 주변지반의 굴착에 따른 교각의 고유진동수 측정실험을 수행하였다. 폐교예정인 만경강교의 우물통기초 교각에서 충격진동시험을 수행하였다. 교각의 상단, 중앙, 하단에 가속도계를 부착하고 세 지점을 타격하여 가속도를 계측하였다. 실험 결과, 타격위치에 따른 가속도 측정값 중 상단타격이 일관되고 합리적인 가속도 결과를 보여주었다. 계측된 가속도는 고속 푸리에 변환(FFT)을 통하여 주파수 영역으로 변환되었고, 이를 이용하여 고유진동수를 측정하였다. 또한, 세굴이 교각의 고유진동수 변화에 미치는 영향을 분석하기 위하여 교각 주변 지반을 굴착하면서 고유진동수의 변화를 측정하였다. 그 결과, 굴착 깊이에 따라 고유 진동수가 감소하는 경향을 보여주었지만, 우물통 기초형식이 큰 강성을 가지고 있어 그 감소폭은 작은 것으로 나타났다.

고립파 작용하 직립호안 주변에서 지반의 동적응답에 관한 수치시뮬레이션 (Simulation of Solitary Wave-Induced Dynamic Responses of Soil Foundation Around Vertical Revetment)

  • 이광호;육승민;김도삼;김태형;이윤두
    • 한국해안·해양공학회논문집
    • /
    • 제26권6호
    • /
    • pp.367-380
    • /
    • 2014
  • 지진해일파(tsunami)에 의한 피해로 소중한 인명손실뿐만 아니라 침수 범람에 의한 가옥과 같은 건물의 유실 및 방파제, 교량 및 항만과 같은 사회간접자본의 심각한 파괴 등을 들 수 있다. 본 연구의 대상인 연안구조물에서 피해원인으로 먼저 큰 지진해일파력을 고려할 수 있지만, 더불어 기초지반에서 세굴과 액상화와 같은 지반파괴를 고려할 수 있다. 진동성분과 잔류성분으로 구성되는 과잉간극수압의 증가에 따른 유효응력의 감소로 해저지반내에 액상화의 가능성이 나타나고, 액상화가 발생되면 그의 진행에 따라 구조물의 침하 혹은 전도에 의해 종국적으로 구조물이 파괴될 가능성이 높아지게 된다. 본 연구에서는 2D-NIT(Two-Dimensional Numerical Irregular wave Tank)모델로 부터 고립파를 조파시켜 직립호안 및 해저지반상에서 시간변동의 동파압을 산정하고, 그 결과를 지반의 동적응답과 구조물의 동적거동을 정밀하게 재현할 수 있는 유한요소법에 기초한 탄 소성해저지반응답의 수치해석프로그램인 FLIP(Finite element analysis LIquefaction Program)모델에 입력치로 적용하여 해저지반 및 직립호안의 주변에서 과잉간극수압 및 유효응력의 시 공간변화, 지반변형, 구조물의 변위 및 지반액상화 등을 정량적으로 평가하여 직립호안의 안정성을 평가한다.

단파작용에 따른 호안과 지반의 동적응답 해석 (Bore-induced Dynamic Responses of Revetment and Soil Foundation)

  • 이광호;육승민;김도삼;김태형;이윤두
    • 한국해안·해양공학회논문집
    • /
    • 제27권1호
    • /
    • pp.63-77
    • /
    • 2015
  • 지진해일파(tsunami)에 의한 피해로 소중한 인명손실뿐만 아니라 침수 범람에 의한 가옥과 같은 건물의 유실, 그리고 방파제, 교량 및 항만과 같은 사회간접자본의 심각한 파괴 등을 들 수 있다. 본 연구의 대상인 연안구조물에서 피해원인으로 먼저 큰 작용파력을 고려할 수 있지만, 또한 기초지반에서 세굴과 액상화와 같은 지반파괴를 고려할 수 있다. 진동성분과 잔류성분으로 구성되는 과잉간극수압의 증가에 따른 유효응력의 감소로 해저지반 내에 액상화의 가능성이 나타나고, 액상화가 발생되면 그의 진행에 따라 구조물의 침하 혹은 전도에 의해 종국적으로 구조물이 파괴될 가능성이 높아지게 된다. 본 연구에서는 수위차를 이용하여 단파를 발생시키고, 그의 전파 및 직립호안과의 상호작용을 2D-NIT(Two-Dimensional Numerical Irregular wave Tank)모델로부터 해석한다. 이러한 결과로부터 직립호안 및 해저지반상에서 시간변동의 동파압을 지반의 동적응답과 구조물의 동적거동을 정밀하게 재현 할 수 있는 유한요소법에 기초한 탄 소성해저지반응답의 수치해석프로그램인 FLIP(Finite element analysis LIquefaction Program)모델에 입력치로 적용하여 해저지반 및 직립호안의 주변에서 과잉간극수압비와 유효응력경로의 시 공간변화, 지반변형, 구조물의 변위 및 지반액상화 등을 정량적으로 평가하여 직립호안의 안정성을 평가한다.

Geotechnical Engineering Progress with the Incheon Bridge Project

  • Cho, Sung-Min
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.133-144
    • /
    • 2009
  • Incheon Bridge, 18.4 km long sea-crossing bridge, will be opened to the traffic in October 2009 and this will be the new landmark of the gearing up north-east Asia as well as the largest & longest bridge of Korea. Incheon Bridge is the integrated set of several special featured bridges including a magnificent cable-stayed girder bridge which has a main span of 800 m width to cross the navigation channel in and out of the Port of Incheon. Incheon Bridge is making an epoch of long-span bridge designs thanks to the fully application of the AASHTO LRFD (load & resistance factor design) to both the superstructures and the substructures. A state-of-the-art of the geotechnologies which were applied to the Incheon Bridge construction project is introduced. The most Large-diameter drilled shafts were penetrated into the bedrock to support the colossal superstructures. The bearing capacity and deformational characteristics of the foundations were verified through the world's largest static pile load test. 8 full-scale pilot piles were tested in both offshore site and onshore area prior to the commencement of constructions. Compressible load beyond 30,000 tonf pressed a single 3 m diameter foundation pile by means of bi-directional loading method including the Osterberg cell techniques. Detailed site investigation to characterize the subsurface properties had been carried out. Geotextile tubes, tied sheet pile walls, and trestles were utilized to overcome the very large tidal difference between ebb and flow at the foreshore site. 44 circular-cell type dolphins surround the piers near the navigation channel to protect the bridge against the collision with aberrant vessels. Each dolphin structure consists of the flat sheet piled wall and infilled aggregates to absorb the collision impact. Geo-centrifugal tests were performed to evaluate the behavior of the dolphin in the seabed and to verify the numerical model for the design. Rip-rap embankments on the seabed are expected to prevent the scouring of the foundation. Prefabricated vertical drains, sand compaction piles, deep cement mixings, horizontal natural-fiber drains, and other subsidiary methods were used to improve the soft ground for the site of abutments, toll plazas, and access roads. Light-weight backfill using EPS blocks helps to reduce the earth pressure behind the abutment on the soft ground. Some kinds of reinforced earth like as MSE using geosynthetics were utilized for the ring wall of the abutment. Soil steel bridges made of corrugated steel plates and engineered backfills were constructed for the open-cut tunnel and the culvert. Diverse experiences of advanced designs and constructions from the Incheon Bridge project have been propagated by relevant engineers and it is strongly expected that significant achievements in geotechnical engineering through this project will contribute to the national development of the longspan bridge technologies remarkably.

  • PDF

동적 응답 분석을 통한 철도교량 하부구조의 피해평가기법연구 (A Study on Damage Assessment Technique of Railway Bridge Substructure through Dynamic Response Analysis)

  • 이명재;이일화;유민택
    • 한국지반공학회논문집
    • /
    • 제37권11호
    • /
    • pp.61-69
    • /
    • 2021
  • 본 연구는 교각의 고유진동수를 통해 교각에 인접한 지반의 세굴 발생여부를 판단하기 위해 축소모형교각을 제작하여 충격하중을 이용해 일련의 비파괴 실험을 수행하였다. 축소모형교각은 길이별로 총 3개의 교각을 제작하였으며, 관입깊이는 0.35m로 일정하게 지반에 관입하였다. 세굴은 크게 2가지로 교각의 측면세굴과 기초바닥세굴을 모사하였으며, 0.05m씩 굴착하여 단계별로 step 0에서 step 12 까지 총 13단계의 실험을 모든 교각에 대해 수행하였다. 또한 고유진동수를 도출하기 위해 모형교각에 총 3개의 가속도계를 부착하여 충격하중을 측정하였다. 충격하중은 impact hammer를 사용하였으며, 타격방향은 모형교각 상단을 교축직각방향으로 타격하였다. 이 때 측정된 가속도 값을 바탕으로 고속 푸리에 변환(FFT)를 이용해 세굴진행도에 따른 고유진동수를 산정했다. 그 결과 세굴이 진행됨에 따라 모든 교각의 고유진동수는 감소하는 경향을 보였다. 세굴이 진행됨에 따라 최초 고유진동수의 70% 이상 수준에서는 측면세굴, 70% 미만에서는 기초바닥세굴이 발생하는 것을 판단할 수 있었다. 이 결과를 토대로 전도에 대한 안전율과 비교하여 교각기초의 피해정도를 분석할 수 있었다.