• 제목/요약/키워드: Forming coil

검색결과 73건 처리시간 0.028초

Anticorit Prelube oils for sheet metal forming Lubricity joined to corrosion protection for steel mill and automotive press shop application

  • LOSCH A.;KUBICKI F.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.249-254
    • /
    • 2004
  • The pressing of car body parts is one of the most important sheet metal drawing processes. The corrosion protection oil applied by the steel mills plays a part in every sheet metal forming operation and also makes up the largest proportion of lubricants used. The idea to combine the corrosion protection properties of a corrosion preventive oil with the lubricity of a drawing oil lead to the development of the Anticorit prelubes. Applied at the finishing lines of the steel mills, they finally serve as lubricant in the press shops. A prerequisite for the suitability of a prelube-type oil is the absolute compatibility with all single processes from the coil to the Body in White. The use of prelubes in steel mills reduces the number and quantity of spot lubricants for additional press shop oiling dramatically. But their true benefits can only be fully achieved if the compatibility principle is applied throughout the manufacturing chain. Therefore, modem prelubes systems are modular, even different viscosities can be part of the same concept. This results in a far-reaching multifunctionality of the Anticorit prelube system for all applications.

  • PDF

말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료시스템의 설계 및 제작 (Design and manufacture of mini loop coil magnetic curer for peripheral nervous system treatment)

  • 김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.153-155
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong.) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료기 (Mini loop coil magnetic curer for peripheral nervous system treatment)

  • 김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.49-51
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse torn and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

냉간 성형용 열연 고강도 강판의 교정 중 잔류응력 변화와 절단 후 캠버 발생 예측 (Residual Stress Evolution during Leveling of Hot Rolled High Strength Coils and Camber Prediction by Residual Stress Distribution)

  • 박기철;류재화
    • 소성∙가공
    • /
    • 제17권2호
    • /
    • pp.107-112
    • /
    • 2008
  • In order to investigate the residual stress evolution during the leveling process of hot rolled high strength coils for cold forming, the in-plane residual stress of plate sampled at SPM, rough leveler and finish leveler were measured by cutting method. Residual stress was localized near the edge of plate. As the thickness of plate was increased, the size of residual stress region was expanded. The gradient of residual stress within the plate was reduced during the leveling process. But the residual stress itself was not removed completely within the ranges of tested conditions. The exact camber of cut plate was able to be predicted by the measurement of residual stress distribution after leveling of the plate.

$\cdot$병렬 공진형컨버터를 이용한 비접촉전원 (Contact-less Power Supply Using Series-Parallel Rasonant Converter)

  • 김은수;구대현;김종무;강도현;신병철;공영수;양승철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.103-107
    • /
    • 2002
  • A contact-less power supply system (CPS) allows electrical energy to supply to mobile consumers without any electrical or mechanical contact. CPS works in the same principle as a transformer, with the track litz cable forming the primary circuit and the pickup as the secondary. The track power supply generates the high frequency alternating current in the track cable. The captured AC magnetic field generated by the track conductors produces electrical energy in the pickup coil and the pickup rectifier converts the high frequency AC power to DC while regulating the power to the load. This paper presents the theoretical analysis, simulation and experiment리 results of the series-parallel resonant converter working as contact-less power supply system.

  • PDF

집적화된 Nb DC SQUID 소자의 제작 및 특성 (Fabrication and Characteristics of Integrated Nb DC SQUID)

  • 이용호;권혁찬;김진목;박종철
    • 한국자기학회지
    • /
    • 제2권3호
    • /
    • pp.277-281
    • /
    • 1992
  • 입력코일과 변조코일이 박막 형태로 집적화된 planar DC SQUID를 제작하고 그 특성을 조사하였다. SQUID loop은 균일한 외부자장의 영향을 받지 않도록 두개의 ring이 '8'자형으로 직렬로 연결된 구조를 하고 있으며, 조셉슨 접합으로는 Pd shunt 저항을 가지는 Nb/Al-oxide/Nb 턴넬 접합을 이용하였다. 소자는 포토리소그라피 기술과 RF 마그네트론 스퍼터링 및 양극산화 방법으로 제작하였으며, 제작된 SQUID는 4.2 K에서 기본적인 특성을 측정한 결과 standard readout 시스템에 적합한 매끄러운 특성을 보였으며 전압 잡음은 측정할 수 없을 정도로 작아 white noise는 최대 $10^{-4}\;{\phi}_o/\;\sqrt{H_z}$ 이하로 나타났다. 현재 matching 코일을 사용하여 잡음 특성을 측정중에 있으며 앞으로 SQUID parameter를 최적화할 경우 매우 고감도의 자기센서로 활용될 수 있을것으로 기대된다.

  • PDF

국부가열용 고주파 유도가열 특성에 관한 연구 (A Study on Characteristic of High Frequency Induction Heating for Local Heating)

  • 진형국;이동주;신상범
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2010년도 춘계학술발표대회 초록집
    • /
    • pp.60-60
    • /
    • 2010
  • Since the curved hull plate was made by a series of manufacturing process including cold bending, manual local heating and correction work, the accuracy of curved plate strongly depends on the proficiency of worker. So the demands on the automatic local heating system for curved hull plate have continuously increased and the various researches relevant to it have been performed. Generally, the heat sources used for local heating were flame and induction heat. In terms of initial cost, flame heating is in a better favorable position than induction heating. However, from the viewpoint of the control of heat, induction heating has more advantage. So the various researches related to apply the induction heating to the automatic forming system has been performed. The purpose of this study is to establish the proper capacity of high frequency induction heating system for forming the curved hull plate. In order to do it, the proper coil shape for local heating was designed and the efficiency of induction heating system was determined by comparing of temperature results obtained by FEA and experiment. With the results, the extensive FEA was performed to identify the effect of heated plate dimension, cooling method and the capacity of induction heating system on the amount of heat loss introduced by induction heating. Based on the results, the proper capacity of high frequency induction heating system was proposed.

  • PDF

TRIP1180 판재의 냉간 스탬핑공정에서 금형강의 경도 특성에 따른 내마모성 평가 (Quantitative Evaluation of Wear Resistance of Stamping Tool with Respect to Hardness of Tool Materials in Cold Stamping of TRIP1180 Steel Sheets)

  • 방준호;배기현;송정한;김홍기;이명규
    • 소성∙가공
    • /
    • 제31권3호
    • /
    • pp.129-135
    • /
    • 2022
  • The purpose of this study was to quantitatively evaluate the influence of hardness of tool materials on wear resistance in the sheet metal forming process. Punches used in the wear test were made of STD-11 and K340 tool material, and the tempering temperature was set to 530℃ and 500℃, respectively, to control the hardness of the tool materials. The punches mimic the shape of stamping tool of automotive body component to reflect its plastic deformation, and are designed to concentrate wear on the curvature region of punches. Progressive die and coil sheet were used to save time, cost, and raw sheet materials. By quantitatively measuring the wear depth of the punches, the wear behavior and mechanism of the punches were investigated, and characteristics of hardness and wear resistance according to tool materials and tempering temperatures were evaluated. Testing results indicate that the punch made of K340 tool steel with higher hardness had better wear resistance than that of STD-11 tool steel, and the hardness and wear resistance of tool steel were significantly impacted by the tempering temperature.

MR 밸브의 전자기적 설계와 성능평가 (Electromagnetic Design and Performance Evaluation of an MR Valve)

  • 김기한;남윤주;박명관
    • 대한기계학회논문집A
    • /
    • 제32권3호
    • /
    • pp.240-249
    • /
    • 2008
  • This paper presents an electromagnetic design method for magneto-rheological (MR) valves. Since the apparent viscosity of MR fluids is adjusted by applying magnetic fields, the MR valves can control high-level fluid power without any mechanical moving parts. In order to improve the performances of the MR valve, it is important that the magnetic field is effectively supplied to the MR fluid. For the purpose, the magnetic circuit composed with the yoke for forming magnetic flux path, the electromagnetic coil and the MR fluid should be well designed. In order to improve the static characteristic of the MR valve, the length of the magnetic flux path is decreased by removing the unnecessary bulk of the yoke. Also, in order to improve its dynamic and hysteretic characteristics, the magnetic reluctance of the magnetic circuit should be increased by minimizing the cross-sectional area of the yoke through which the magnetic flux passes. After two MR valves, one is a conventional type valve and the other is the proposed one, are designed and fabricated, their performances are evaluated experimentally.

Isolation, Purification and Characterization of Polysaccharides that induce in vitro Immuno-Stimulation of Macrophases derived from Liquid Culture of Cordyceps militaris

  • Kwon, Jeong-Seok;An, Hyo-Sil;Hong, Eock-Kee
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVII)
    • /
    • pp.287-292
    • /
    • 2005
  • The crude polysaccharides(C-CPF, C-CPM, C-CPB) derived from fruiting body, mycelia and mycelia free broth of cordyceps militaris were obtained by ethanol precipitation of hot water extracts. After a batch fermentation of C. militaris was carried out in a 5 L jar vessel, endo-polysaccharide and exo-polysaccharide were obtained. They were demonstrated as the hetero polysaccharides which were composed of glucsose, galactose and mannose by performed with HPAEC(high pH anion exchange chromatography) and conformation of random coil by its complex forming ability with congo red reagent. They were purified by ion exchange (DEAE-cellulose) and gel filtration chromatography. They were monitered by phenol-sulfuric acid method and Bradford method. The NO induction activities of crude polysaccharides and purified polysaccharides derived from mycelia free broth were enhanced rather than LPS(lipo polysaccharide) which was used as a general NO inducer. These effects presumably contibute to the antitumor activities. The homogenieties and molecular weights of polysaccharides were determined by using Sepharose CL-6B. The yield, molecular weights and NO induction activities of C-CPFN Fr.III, C-CPMN Fr.III, C-CPBN Fr.II were 0.387, 0.408 and 0.153, 127 K 210 K and 36 K, 40.79%, 88.72%, and 104.17%, respectively.

  • PDF