• 제목/요약/키워드: Form removal

검색결과 591건 처리시간 0.028초

Performance evaluation of TEDA impregnated activated carbon under long term operation simulated NPP operating condition

  • Lee, Hyun Chul;Lee, Doo Yong;Kim, Hak Soo;Kim, Cho Rong
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2652-2659
    • /
    • 2020
  • The methyl iodide (CH3I) removal performance of tri-ethylene-di-amine impregnated activated carbon (TEDA-AC) used in the air cleaning unit of nuclear power plants (NPPs) should be maintained at least 99% between 24 month-performance test period. In order for evaluating the effectiveness of TEDA-AC on the removal performance of CH3I in nuclear power plant during the operation of NPPs, the long-term test for up to 15 months was carried out under the simulated operating conditions (e.g., 25 ℃, RH 50%, ppb level poisoning gases injection) at nuclear power plants (NPPs). The TEDA-AC samples were analyzed with the Brunauer-Emmett-Teller (BET) specific surface area and TEDA content as well as CH3I penetration test. It is clearly evident that more than 99% of CH3I removal performance of TEDA-AC was observed in the TEDA-AC samples during 15 months of long-term operation under the simulated NPP operating conditions including the ppb level of organic and oxide form of poisoning gases. BET specific surface area and TEDA content that can affect the CH3I removal performance of TEDA-AC were also maintained as those in new TEDA-AC during 15 months of long-term operation.

오존/과산화수소공정(Peroxone AOP)을 이용한 Diazinon 제거 특성 연구 (Study on the Removal Characteristics of Diazinon Using Ozone / Hydrogen Peroxide)

  • 윤효진;한인섭;윤우현
    • 한국도시환경학회지
    • /
    • 제18권4호
    • /
    • pp.391-399
    • /
    • 2018
  • 본 연구에서 농약 중에서도 가장 널리 사용되는 유기인계 농약(OPPs)인 Diazinon을 오존/과산화수소 고도산화공정(Peroxone AOP)을 적용하여 제거하고자 하였다. Diazinon은 주로 지하수, 식수, 하천, 사용 농업지역과 가까운 지역의 연못에서 발견되어 체내에 대사체 형태로 축적되면 신경독성 및 정신착란, 어지럼증, 구토 등을 유발한다. 기존의 수처리 공정으로는 잘 제거되지 않는 Diazinon을 오존과 과산화수소를 이용하여 강한 산화력을 가지는 OH radical을 발생시켜 이에 의한 제거 특성을 검토하였다. 최적의 과산화수소/오존 주입 mole비를 도출하고, 제거효율에 영향인자로 작용하는 초기 Diazinon 농도, pH, DOC 농도에 대하여 제거 반응을 확인하였다. 국내의 환경 중 농약 제거에 대한 연구는 국외의 경우보다 매우 미진한 실정이다. 본 연구는 향후 농약물질 제거를 위한 공정 설계에 기반을 마련할 것으로 판단된다.

FeS 수용액 내 pH에 따른 5가비소의 반응 메커니즘 연구 (Mechanistic Study of FeS Reacted with Arsenate under Various pH Conditions)

  • 한영수;이무열;성혜진
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제27권1호
    • /
    • pp.25-30
    • /
    • 2022
  • Mackinawite (FeS), as a ubiquitous reduced iron mineral, is known as a key controller of redox reactions in anaerobic subsurface environment. The reaction of FeS with redox-sensitive toxic element such as arsenic is substantially affected by pH conditions of the given environments. In this study, the interaction of As(V) with FeS was studied under strict anaerobic conditions with various pH conditions. The pH-dependent arsenic removal tests were conducted under wide ranges of pH conditions and X-ray absorption spectroscopy (XAS) was applied to investigate the reaction mechanisms under pH 5, 7, and 9. The removal efficiency of FeS for As(V) showed the higher removal of As(V) under low pH conditions and its removal efficiency decreased with increasing pH, and no As(V) reduction was observed in 1 g/L FeS solution. However, XAS analysis indicated the reduction of As(V) to As(III) occurred during reaction between FeS and As(V). The reduced form of As(III) was particularly identified as an arsenic sulfide mineral (As2S3) in all pH conditions (pH 5, 7, and 9). As2S3 precipitation was more pronounced in pH 5 where the solubility of FeS is higher than in other pH conditions. The linear combination fitting results of XAS demonstrated that As(V) removal mechanism is concerted processes of As2S3 precipitation and surface complexation of both arsenic species.

The Impact of the Morphological Characteristics of Leaves on Particulate Matter Removal Efficiency of Plants

  • Son, Deokjoo;Kim, Kwang Jin;Jeong, Na Ra;Yun, Hyung Gewon;Han, Seung Won;Kim, Jeongho;Do, Gyung-Ran;Lee, Seon Hwa;Shagol, Charlotte C.
    • 인간식물환경학회지
    • /
    • 제22권6호
    • /
    • pp.551-561
    • /
    • 2019
  • This study was conducted to find out differences in the removal efficiency of particulate matter (PM) depending on the type of plants and the morphological characteristics of leaves. A total of 12 plants were used, with three plants selected for each type of leaves (big leaf, small leaf, compound leaf, needle leaf). We measured the removed amount of PM10 and PM2.5, the structure of the abaxial leaf surface, and the weight of the wax layer of each plant. Plants with the high removal efficiency of PM included Pachira aquatica Aubl., Ardisia crenata, and Dieffenbachia 'Marianne', and plants with the low removal efficiency included Nandina domestica Thunb, Schefflera arboricola, and Quercus dentata. The abaxial leaf surface having a high removal efficiency of PM had many large wrinkles, and the abaxial leaf surface having a medium removal efficiency was flat and smooth. On the other hand, there were many fine hairs on the abaxial leaf surface with a low removal efficiency. According to the plant leaf type, the PM10 removal efficiency of plants with needle leaves was about three times higher than that of other plants. In particular, the wax layer of conifers weighed 6-24 times higher than those of other plants. The stomata of conifers were evenly distributed on the adaxial and abaxial leaf surfaces; however, the stomata of Sciadopitys verticillata appeared in the form of papillae unlike general stomata. Therefore, the removal efficiency of PM varied depending on the macro-, and micro-morphological characteristics of plant leaves such as the structure of the abaxial leaf surface, and the weight of the wax layer. Based on this research, selecting plants that are effective in reducing PM in consideration of the plant type and leaf characteristics will improve indoor air quality and decrease exposure of PM to human body.

융합형여과집진장치에서의 먼지입자와 원소수은의 제거 성능 특성 (Simultaneous Removal Characteristics of Particulate and Elemental Mercury in Convergence Particulate Collector)

  • 박영옥;정주영
    • 한국입자에어로졸학회지
    • /
    • 제6권4호
    • /
    • pp.173-183
    • /
    • 2010
  • The high temperature pleated filter bags which were used during this study were made of pleated nonwoven fabric of heat and acid resistant polysulfonate fibers which can withstand the heat up to $300^{\circ}C$ and have a filtration area which is 3 to 5 times larger than the conventional round filter bags. Cartridge module packed with 3 kind of the sulfur impregnated activated-carbon based sorbents were inserted in the inner of the pleated filter bag. This type of pleated filter bag was designed to remove not only the particulate matter but also the gaseous elemental mercury. The electrostatic precipitator part can enhance the particulate removal efficiency and reduce the pressure drop of the pleated filter bag by agglomerated particles to form a more porous dust layer on the surface of the pleated bag which is increased the filter bag cleaning efficiency. In addition, the most of particles are separated from the flue gas stream through the cyclone and the electrostatic precipitator part which were installed at the lower part and main body part of the convergence particulate collector, respectively. Thus reduce particulate loading of the high temperature pleated filter bags were applied in this study to analyze the removal characteristics of particulate matter and gaseous elemental mercury.

Solvent/Detergent Inactivation and Chromatographic Removal of Human Immunodeficiency Virus During the manufacturing of a High Purity Antihemophilic Factor VIII concentrate

  • Kim, In-Seop;Park, Yong-Woon;Woo, Hang-Sang;Chong E. Chang;Lee, Soungmin
    • Journal of Microbiology
    • /
    • 제38권3호
    • /
    • pp.187-191
    • /
    • 2000
  • A validation study was conducted to determine the efficacy of solvent/Detergent (S/D) inactivation and Q-Sepharose column chromatographic removal of the human immunodeficiency virus (HIV) during the manufacturing of a high purity antihemopilic factor VIII (GreenMono) from human plasma. S/D treatment using the organic solvent, tri (n-butyl) phosphate, and the detergent, Trition X-100, was a robust and effective step in eliminating HIV-1. The HIV-1 titer was reduced from an initial titer of 8.3 log10 TCID50 to undetectable levels within one minute of S/D treatment, HIV-1 was effectively partitioned form factor VIII during Q-Sepharose column chromatography with the log reduction factor of 4.1 . These results strongly assure the safety of GreenMono From HIV.

  • PDF

Silica계 응집제를 이용한 광산폐수의 중금속 및 음이온 제거 (The Removal of Heavy Metals and Anion in Mining Wastewater by Silica Matrix Coagulation)

  • 이해승;이영신;현근우
    • 환경위생공학
    • /
    • 제16권3호
    • /
    • pp.80-86
    • /
    • 2001
  • This research was carried out to investigate the effect of microscopic silica matrix coagulation on heavy metals and anion removal in mining wastewater. pH and alkalinity played an important role to coagulate heavy metals such as Al, and Fe and an anion such as ${SO_4}^{2-}$ with silica matrix as well as NaOH. However, the efficiency to form coagulates was much greater in silica matrix-treated wastewater than NaOH-treated one. Fe in wastewater formed coagulation with both silica matrix and NaOH treatments resulting in lowering Fe content in wastewater at above pH 9. For Al removal in wastewater, silica matrix-treated wastewater at above pH 12.3 formed stable coagulate with Al, while NaOH-treated one did not. Alkalinities of 89 and 220 mg/L were required to stabilize silica matrix treated coagulate with Fe and Al, respectively. Reaction time of ten minute was required to provide enough reaction for coagulation between heavy metals and silica matrix. Heavy metals and anion leachates were much lower in coagulate with silica matrix than that with NaOH, which indicates that silica matrix could be used to remove heavy metals efficiently.

  • PDF

Application of S-HGMS and chemical coupling technology in river water treatment

  • Zhao, Xin;Li, Su-qin;Han, Shuai-shuai;Zhang, Peng;Jin, Jian-jiang;Guo, Peng-hui
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권2호
    • /
    • pp.12-16
    • /
    • 2020
  • Circulating cooling systems consume a lot of water, and most of the water from river, which contains a large amount of Ca2+, Mg2+, et al, and has the characteristics of high hardness and large turbidity. The water can form scale on the surface of the heat exchanger and the pipes, which would reduce the heat transfer efficiency and affect the heat exchanger's length of service. In this study, the Superconducting High Gradient Magnetic Separation (S-HGMS) technology was used in river water treatment and the effects of agent A, agent B, and S-HGMS on the removal of hardness and turbidity were discussed. The results showed that the hardness removal rate reached 71.3% and the turbidity was decreased to 0.5 NTU.

트리에탄올아민을 사용한 콘크리트의 현장 적용 실험 (An Experimental Application of Concrete Using TEA in Construction Field)

  • 황인성;임춘근;김성수;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.23-26
    • /
    • 2003
  • This study is intended to investigate the properties of early strength development by application of TEA to the field. According to the results, when TEA is added, fluidity is almost same to base concrete, and increases upto aimed slump after field flowing. Setting time does not differ in the case of base and TEA, but retarded after flowing. The time when compressive strength gains 5 MPa, which side form can be removed, is 23 hours, and so the removal time is shortened by I hours in comparison with plain concrete. But compressive strength is almost same to that of plain concrete at 28 days. The rebound value of P type schmidt hammer show similar tendency to compressive strength, and the rebound value of structure is higher than that of standard curing specimen due to heat capacity effect and drying by the air outside. Therefore, it is thought that if the rebound value of P type schmidt hammer is controled. by about 26 in consideration of open air environment, it is very effective to determine the removal time of side forms.

  • PDF

카드뮴 텔룰라이드 CMP 공정에서 산화제가 연마에 미치는 영향 (Effect of Oxidizer on the Polishing in Cadmium Telluride CMP)

  • 신병철;이창석;정해도
    • 한국정밀공학회지
    • /
    • 제32권1호
    • /
    • pp.69-74
    • /
    • 2015
  • Cadmium telluride (CdTe) is being developed for thin film of the X-Ray detector recently. But a rough surface of the CdTe should be improved for resolution and signal speed. This paper shows the study on the improvement of surface roughness and removal rate by applying Chemical Mechanical Polishing. The conventional potassium hydroxide (KOH) based colloidal silica slurry could not realize a mirror surface without physical defects, resulting in low material removal rate and many scratches on surface. In order to enhance chemical reaction such as form oxidized layer on the surface of cadmium telluride, we used hydrogen peroxide ($H_2O_2$) as an oxidizer. Consequently, in case of 3 wt% concentration of hydrogen peroxide, the highest MRR (938 nm/min) and the lowest surface roughness ($R_{p-v}=10.69nm$, $R_a=0.8nm$) could be obtained. EDS was also used to confirm the generated oxide of cadmium telluride surface.