• Title/Summary/Keyword: Force-Touch

Search Result 94, Processing Time 0.038 seconds

Flexible tactile sensor for minimally invasive surgery (최소 침습 수술을 위한 유연한 촉각 센서)

  • Lee, Junwoo;Yoo, Yong Kyoung;Han, Sung Il;Kim, Cheon Jing;Lee, Jeong Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1229-1230
    • /
    • 2015
  • Monitoring of mechanical properties of tissues as well as direction/quantities of forces is considered as an essential way for disease diagnosis and haptic feedback systems. There are extensively increasing interests for measuring normal/shear force and touch feelings, especially for surgery systems. Highly sensitive and flexible tactile sensor is needed in palpation for detecting cancer cyst as well as real time pressure monitoring in minimally invasive surgery (MIS). Importantly, MEMS technique with miniaturized fabrication technique is essential for the on-chip integration with biopsy and biomedical grasper. Here, we propose the flexible tactile sensor with high sensitivity based on piezoresistive effect. We analyzed the sensitivity according to the pressure and directions and showed the ability of discrimination of the different materials surfaces, illustrating the feasibility of the flexible tactile sensor for biomedical grasper by mimicking human skin.

  • PDF

Densification Mechanism of Warm Compaction for Iron-based Powder Materials

  • Qu, Shengguan;Li, Yuanyuan;Xia, Wei;Chen, Weiping
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.201-202
    • /
    • 2006
  • An apparatus measuring changes of various forces directly and continuously was developed by a way of direct touch between powders and transmitting force component, which can be used to study forces state of powders during warm compaction. Using the apparatus, warm compaction processes of iron-based powder materials containing different lubricants at different temperatures were studied. Results show that densification of the iron-based powder materials can be divided into four stages, in which powder movement changes from robustness to weakness, while its degree of plastic deformation changes from weakness to robustness.

  • PDF

Quantitative Analysis of Enlarged Cervical Lymph Nodes with Ultrasound Elastography

  • Zhang, Jun-Peng;Liu, Hua-Yan;Ning, Chun-Ping;Chong, Jing;Sun, Yong-Mei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7291-7294
    • /
    • 2015
  • Purpsoe: To investigate the diagnostic value of quantitative analysis of a tissue diffusion and virtual touch tissue imaging quantification (VTIQ) technique with acoustic radiation force impulse (ARFI) elastography for assessing enlarged cervical lymph nodes. Materials and Methods: Fifty-six enlarged cervical lymph nodes confirmed by pathologic diagnoses were covered in the study. According to the results of pathologic diagnosis, patients were classified into benign and malignant groups. All the patients were examined by both conventional ultrasonography and elastography. AREA% and shear wave velocity (SWV) in ROI of different groups were calculated and compared using ROC curves. Cut-off points of AREA% and SWV were determined with receiver operating characteristic curves. Results: Final histopathological results revealed 21 cases of benign and 35 cases of malignant lymph nodes. The mean values of AREA% and SWV in benign and malignant groups were $45.0{\pm}17.9%$ and $2.32{\pm}0.57m/s$, and $61.3{\pm}21.29%$ and $4.36{\pm}1.25$)m/s, respectively. For the parameters of elastography, "AREA%" and SWV demonstrated significant differences between groups (p=0.002). AREA% was positively correlated with SWV with a correlation coefficient of 0.809 (P<0.001). Conclusions: Stiffness of different lymph node diseases in patients may differ. Elastography can evaluate changes sensitively and provide valuable information to doctors. The study proved that the VTIQ elastography technique can play an important role in differential diagnosis of lymph nodes.

A Study on the Measurement of Electric Resistance of Footwear (신발의 전기저항 측정에 관한 연구)

  • Choi, Sang-Won;Lee, Seokwon
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.56-62
    • /
    • 2013
  • The occurrence of the ventricular fibrillation is directly dependent on the magnitude and duration of the current. The current which flows through the human body is proportional to the touch voltage applied across the body and is in inverse proportion to the impedances in the circuit. The circuit impedances consist of human body impedance, line impedance, equipment impedance, earth terminal impedance and impedance of shoes which a person put on. The impedance of shoes greatly affect the severity of the electric accidents. The human body impedances relevant to the contact areas, contact conditions, current paths and touch voltages are already determined in the IEC 60479-1. However, the impedance of shoes is ignored or substituted by a simple value because of the absence of the sufficient data. For example, the impedance of shoes plus ground contact resistance is postulated to be $1,000{\Omega}$ in the IEC 61200-612. In IEEE 80, the shoe resistance plus ground contact resistance is assumed to be bare foot with ${\rho}/4b{\Omega}$. In this paper, we measured and analyzed the impedance of shoes with respect to conditions such as applied weight, environment variables and voltages. The results showed that the impedance of shoes is dependent on environment variables regardless of the types of shoes. Most of shoes showed the correlation with the applied force, whereas a few shoes showed characteristics related to the applied voltage. In terms of severity of electric shock, one thirds of test samples indicated to be dangerous in saltwater conditions.

Electrical Characteristics of the Ag Past with addition of Low-melting Alloy of Bi58Sn42 for Metal Mesh Touch Sensors (저융점 합금(Bi58Sn42)을 이용한 Metal Mesh Touch Sensor용 Ag 페이스트의 전기적 특성)

  • Kim, Tae-Hyung;Heo, Young-Woo;Kim, Jeong-Joo;Lee, Joon-Hyung
    • Journal of Surface Science and Engineering
    • /
    • v.50 no.6
    • /
    • pp.510-515
    • /
    • 2017
  • In this study, a transient liquid phase sintering (TLPS) process of Ag pastes mixed with a fusible metal alloy of Bi58Sn42 with the melting temperature of $138^{\circ}C$, was examined. After screen printing of the Ag pastes with and without Bi58Sn42 powders on polyimide (PI) substrates, the electrodes were heat-treated at different temperatures in the range between 150 and $300^{\circ}C$ for 60 min in air. Comparing the electrical conductivity of the Ag pastes with and without Bi58Sn42 alloy powder after the heat treatment, it was manifested that the low melting temperature alloy definitely played a major role in an increased conductivity when it is added into the Ag pastes by providing more electrical conduction paths between Ag particles. This can be explained by the fact that capillary force of the melts of Bi58Sn42 can contribute to the rearrangement of the Ag particles during the heat-treatment inducing better connectivity between the Ag particles.

EVALUATION AND DEVELOPMENT OF DIGITAL DEVICE FOR MEASURING PROXIMAL TOOTH CONTACT TIGHTNESS (디지털 방식의 인접면 접촉강도 측정장치의 개발 및 평가)

  • Choi, Woo-Jin;Kim, Kyung-Hwa;Kim, Jin-A;Kang, Dong-Wan;Oh, Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.687-695
    • /
    • 2007
  • Statement of problem: The proper contact relation between adjacent teeth in each arch plays an important role in the stability and maintenance of the integrity of the dental arches. Proximal contact has been defined as the area of a tooth that is in close association, connection, or touch with an adjacent tooth in the same arch. Purpose: The aim of this study was to develop a digital device for measuring the proximal tooth contact tightness by pulling a thin stainless steel strip (2mm wide, 0.03mm thick) inserted between proximal tooth contact. Material and method: This device consists of measuring part, sensor part, motor part and body part. The stainless steel strip was connected to a stain gauge. The strain gauge was designed to convert the frictional force into a compressive force. This compressive force was detected as a electrical signal and the electrical signal was digitalized by a A/D converter. The digital signals were displayed by a micro-processor. The pulling speed was 8mm/s. Results: For testing reliability of the device in vivo, two healthy young adults (A, B) participated in this experiment. The tightness of proximal tooth contact between the second premolar and the first molar of mandible (subject A) and maxilla (subject B) was measured fifteen times for three days at rest. We double-checked the accuracy of the device with a Universal Testing Machine. Output signals from the Universal Testing Machine and the measuring device were compared. Regression analysis showed high linearity between these two signals. In vivo test, no significant differences were found between measurements. Conclusion: This device has shown to he capable of producing reliable and reproducible results in measuring proximal tooth contact. Therefore, it was considered that this device was appropriate to apply clinically.

A Comparative Analysis of Kinematics and Kinetics on Forehand Drive in Squash (스쿼시 Forehand 드라이브 동작 시 운동역학적 비교연구)

  • Jin, Young-Wan;Park, Yang-Hee;Park, Jae-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.17-25
    • /
    • 2007
  • The purpose of the study is to give basic data for the improvement of the skill and to show an exemplary position for squash club members or trainers thru a comparative analysis on the kinematics and kinetics variables on the forehand drive motion in playing squash. The objects of the research are divided into two sections, skilled group(n=8) and unskilled group(n=8). The skilled group is composed of professional players currently working and unskilled group is career of six month, both of lives in B city. In this research, to gather the data 3D motion analysis and test result analysis using force platform was used. The variables are duration, position, segment velocity, segment acceleration and etc. in using force platform. The results are as follows: 1. The duration per phase of the skilled is 0.18sec P1(DS) while that of unskilled is 0.32sec. in P2(FT), the duration of the skilled is 0.29sec, that of unskilled is 0.34sec. Average of the duration of the skilled is 0.48sec, while the unskilled, 0.66sec. 2. Regarding positional movements per event, the unskilled has a relatively higher position in center of gravity, shoulder joint, elbow joint compared with that of the skilled. Generally speaking, positions of the unskilled is higher than the skilled. 3. In segment velocity per event, R-shank, R-upper arm, R-forearm and racket. The skilled is faster than the unskilled. we found a big dig difference in shank. 4. In acceleration per event, there was a big difference in upper-arm and fore-arm of the impact. 5. The skilled group on the force platform shows relatively stable and regular changes while the unskilled shows unstable from the touch down to initial 20% the force value of central support period after the impact moment decreases rapidly and the center of gravity is not moved well. 6. The maximum force value of the skilled is 1019.7N. it is found 19.86% of the total duration. That of the unskilled is 639.2N, it is found 20.67% of total duration.

Intuitive Manipulation of Deformable Cloth Object Based on Augmented Reality for Mobile Game (모바일 게임을 위한 증강현실 기반 직관적 변형 직물객체 조작)

  • Kim, Sang-Joon;Hong, Min;Choi, Yoo-Joo
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.4
    • /
    • pp.159-168
    • /
    • 2018
  • In recent, mobile augmented reality game which has been attracting high attention is considered to be an good approach to increase immersion. In conventional augmented reality-based games that recognize target objects using a mobile camera and show the matching game characters, touch-based interaction is mainly used. In this paper, we propose an intuitive interaction method which manipulates a deformable game object by moving a target image of augmented reality in order to enhacne the immersion of the game. In the proposed method, the deformable object is intuitively manipulated by calculating the distance and direction between the target images and by adjusting the external force applied to the deformable object using them. In this paper, we focus on the cloth deformable object which is widely used for natural object animation in game contents and implement natural cloth simulation interacting with game objects represented by wind and rigid objects. In the experiments, we compare the previous commercial cloth model with the proposed method and show the proposed method can represent cloth animation more realistically.

Kinematical Analysis of Men's Pole Vault Event (장대높이뛰기 경기의 운동학적 분석)

  • Lim, Kyu-Chan
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.15-26
    • /
    • 2003
  • This study was conducted to investigate the performance times, CM position and CM speed, pole chord length and pole chord angle, whole body angular momentum(X axis), and grip width in pole vault event according to the event and phase; touch down, pole plant, take-off, maximum pole bending pole straight, pole release, peak height, and foot contact, pole contact, free flight. The pole vaulting of four male elite vaulters including six trial were filmed using two video digital cameras at 60 Hz at 56th national athletic match, and data were collected through the DLT method of three dimensional cinematography. In general the better jumper is, the longer the performance time is. And the greater CM speed is, and the better his transformation ability of CM horizontal speed into vertical speed is. As he uses a longer pole, his grip is higher, and it is a enough for him to rock back his body, so that he pulls and pushes the pole well keeping his hips close to. An greater maximum angular momentum and early positioning of the hips parallel to the bar makes his body far side of the bar and his bar clearance easier. Specially our national jumper needs to have more powerful braking force during foot contact phase, and take his body on the pole after maximum pole bending, and pull and push the pole strongly keeping his hips close to. Also he needs to have stronger muscular strength in order to control the longer pole and use the pole of proper tension more efficiently.

On the dynamic instability analysis of mechanical face seals (기계평면시일의 동적 불안정성에 관한 연구)

  • 김청균;서태석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1509-1514
    • /
    • 1990
  • To investigate the seal dynamic instability for a misaligned and coned mechanical face seal, the finite difference approximation was employed to solve the modified Reynolds equation for an incompressible fluid and temperature dependent viscosity. Using the solution, the results for axial force, transverse moment, restoring moment, and ratio of the transverse moment and the restoring moment are calculated for the whole range from zero to full angular misalignment. The results indicate that the transverse moment due to the angular misalignment and coning terms affects considerably the dynamic instability of face seals. It is shown that the simplified treatment of Reynolds equation using the narrow seal approximation overestimate the ratio of the transverse moment to the restoring moment especially at touch.