• 제목/요약/키워드: Force transducer

검색결과 167건 처리시간 0.025초

A STUDY OF RELATIONSHIP BETWEEN BITE FORCE, MASSETER MUSCLE AND CRANIOFACIAL MORPHOLOGY : CEPHALOMETRIC & ULTRASONOGRAPHIC ANALYSIS (교합력, 교근과 두개안면골 형태의 관계 : 두부규격방사선사진과 초음파진단영상 분석)

  • Lee, Mi-Sook;Choi, Yeong-Chul;Choi, Sung-Chul;Kim, Gwang-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제35권3호
    • /
    • pp.399-417
    • /
    • 2008
  • The aim of this study was to investigate the relationships between bite force, masseter muscle and craniofacial morphology. 141 individuals were included. Bite forces were measured with a bite force transducer(SKT 2004). The facial morphology of the samples was evaluated on the Lateral and PA cephalometric radiographs(Asahi CX-90 SP). Ultrasonographic images were obtained for 36 individuals(Logiq 500). General status of the subjects were also measured for investigating possible relationships. Their relationships were analyzed by means of t-test, Pearson's correlation coefficients and simple regression analysis. In conclusion, bite force of molar was significantly correlated with craniofacial morphology for males and females, but not to masseter muscles. The masseter muscle for males had a significant correlation with craniofacial morphology. The unexpected negative correlations between size of masseter muscle and maxillary width was revealed for males. One possible way to arrive at a plausible explanation for the correlation between masster muscle, bite force and craniofacial morphology of males were the deep layer of masseter muscle had a great influence on males and the superficial layer of masseter muscle had a great influence on females.

  • PDF

Self-administration of an Analgesic Does Not Alleviate Pain in Beak Trimmed Chickens

  • Freire, Rafael;Glatz, Philip C.;Hinch, Geoff
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제21권3호
    • /
    • pp.443-448
    • /
    • 2008
  • Beak trimming in laying hens is a routine practice in which about 1/3-1/2 of the upper and lower beak is removed with the aim of reducing cannibalism. This experiment aimed to identify if this procedure causes pain by examining self-administration of an analgesic (carprofen) and pecking behaviour in 80 laying pullets beak-trimmed by two different methods at one day of age using hot-blade cauterisation or infra-red cauterisation. We also tested a control treatment, pullets with intact beaks, and a positive control treatment of pullets beak trimmed at 10 weeks of age which were expected to experience some pain due to recent severing of the underlying nerves in the beak. At 11 weeks of age birds trimmed at 10 weeks of age pecked more (p<0.001) gently ($0.6{\pm}0.06N$) at a disc attached to a force-displacement transducer than birds trimmed at 1 day of age with an infra-red machine ($0.9{\pm}0.1N$) or a hot blade ($1.1{\pm}0.07N$) and intact birds ($1.2{\pm}0.1N$). Maximum force of pecks recorded was also lower (p<0.001) in birds trimmed at 10 weeks of age than birds trimmed at 1 day of age with an infra-red method or a hot blade and intact birds. However, the pecking force in birds trimmed at 10 weeks of age was not increased by providing them with analgesic-treated feed, though birds that ate more carprofen had a higher maximum force of peck (p = 0.03). Pecking force in birds beak-trimmed at 1 day of age was the same as the pecking force of intact birds, and was unaffected by feeding pullets carprofen. A method of self-administration of an analgesic had previously revealed that chickens in neuromuscular pain arising from lameness consumed more of a feed containing carprofen than healthy chickens. However, we found no evidence that beak-trimmed pullets consumed more carprofen-treated feed than pullets with an intact beak. It should be noted that the three beak trimming methods resulted in an average 34% reduction in beak length, considered a light trim, and is perhaps not representative of commercial birds where greater portions of the beak are removed. We conclude that although carprofen has been reported to have an analgesic effect on neuromuscular pain in chickens, it appears to have no analgesic effect on potential neuropathic pain arising from the nerves severed by a light beak trim.

Wideband and 2D vibration energy harvester using multiple magnetoelectric transducers

  • Yang, Jin;Yu, Qiangmo;Zhao, Jiangxin;Zhao, Nian;Wen, Yumei;Li, Ping
    • Smart Structures and Systems
    • /
    • 제16권4호
    • /
    • pp.579-591
    • /
    • 2015
  • This paper investigates a magnetoelectric (ME) vibration energy harvester that can scavenge energy in arbitrary directions in a plane as well as wide working bandwidth. In this harvester, a circular cross-section cantilever rod is adopted to extract the external vibration energy due to the capability of it's free end oscillating in arbitrary in-plane directions. And permanent magnets are fixed to the free end of the cantilever rod, causing it to experience a non-linear force as it moves with respect to stationary ME transducers and magnets. The magnetically coupled cantilever rod exhibits a nonlinear and two-mode motion, and responds to vibration over a much broader frequency range than a standard cantilever. The effects of the magnetic field distribution and the magnetic force on the harvester's voltage response are investigated with the aim to obtain the optimal vibration energy harvesting performances. A prototype harvester was fabricated and experimentally tested, and the experimental results verified that the harvester can extract energy from arbitrary in-plane directions, and had maximum bandwidth of 5.5 Hz, and output power of 0.13 mW at an acceleration of 0.6 g (with $g=9.8ms^{-2}$).

Development of an Input Force Measuring Method for Vehicle Tests (실차 주행중 입력하중 계측 기법 개발)

  • Lee, Kwang Chun;Kim, Seung Han;Lee, Kang In;Bae, Byung Kook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제41권2호
    • /
    • pp.143-147
    • /
    • 2017
  • In this study, a driving load measuring method has developed without utilizing WFT. To measure the driving load, we developed a three-axis load cell with a strain gage. A method to verify the performance of load cells was developed. A system to measure the input load was proposed, and it was verified by evaluation. The measurement error of the impact road surface was found to be less than 20%. However, except under impact road surface conditions, the proposed system can be applied for actual vehicle input load measurement. The influence of tire evaluation tests were carried out through the handling verification evaluation. The input load measurement methods proposed in the present study make performance verification possible without using WFT.

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권4호
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.

Effects of Dopamine on the Contractility and Action Potential of the Rabbit Papillary Muscle (Dopamine이 토끼 유두근의 수축력과 활동전압에 미치는 영향)

  • Huh, In-Hoi;Park, Jong-Wan
    • YAKHAK HOEJI
    • /
    • 제32권6호
    • /
    • pp.402-414
    • /
    • 1988
  • In order to clarify the receptor types and mechanisms underlying the positive inotropic effect of dopamine on the mammalian ventricular myocardium, the action potential, its first derivatives and isometric contraction of the rabbit papillary muscle were recorded using a force transducer and glass capillary microelectrodes filled with 3M KCl. The results were as follows; (1) In normal Tyrode solution, the contractile force was increased and duration of action potential was shortened with increments of dopamine concentration ($10^{-6}-10^{-4}M$). (2) The dose-response curve was markedly shifted to the right by pretreatment with reserpine (5mg/kg i.p., 24hrs prior to the experiment). (3) In 19mM $K^+-Tyrode$ solution, the duration of action potential, maximum rate of rise (V_{max}) of action potential and overshoot were significantly increased with increments of dopamine concentration ($10^{-6}-10^{-4}M$). (4) The inotropic effect of dopamine on the rabbit papillary muscle pretreated with reserpine was antagonized by atenolol ($10^{-6}M$), but not by phentolamine ($3{\times}10^{-6}M$). (5) In rabbit papillary muscle partially depolarized by 19mM $K^+-Tyrode$ solution, slow electrical response (calcium mediated action potential) as well as contraction were restored by dopamine ($10^{-4}M$); this restoration was blocked by calcium antagonists ($3{\times}10^{-5}M$ $LaCl_3{\cdot}6H_2O$, $3{\times}10^{-6}M$ diltiazem) or ${\beta}-adrenoceptor$ antagonist ($3{\times}10^{-6}M$ atenolol), but not affected by ${\alpha}-adrenoceptor$ antagonist ($10^{-5}M$ phentolamine, $3{\times}10^{-6}M$ yohimbine) or vascular dopaminergic receptor antagonist ($10^{-5}M$ haloperidol). The above results may be interpreted as that the positive inotropic effect of dopamine through both direct and indirect action are caused by increase in slow inward current ($Ca^{2+}$ influx into themyocardial cell), and the direct action is mainly due to the stimulation of ${\beta}-adrenoceptors$ in the rabbit papillary muscle.

  • PDF

Force changes associated with differential activation of en-masse retraction and/or intrusion with clear aligners

  • Zhu, Ye;Hu, Wei;Li, Shuo
    • The korean journal of orthodontics
    • /
    • 제51권1호
    • /
    • pp.32-42
    • /
    • 2021
  • Objective: To investigate the three-dimensional forces created by clear aligners on mandibular teeth during differential activation with en-masse retraction and/or intrusion in vitro. Methods: Six sets of clear aligners were designed for differential en-masse retraction and/or intrusion procedures in a first premolar extraction model. Group A0 was a control group with no activation. Groups A1-5 underwent different degrees of retractions and/or intrusions. Each group consisted of 10 aligners. Aligner forces were measured on a multi-axis force/torque transducer measurement system in real-time. Results: In the en-masse retraction groups (A1 and A2), lingual and extrusive forces were observed on the incisors; the canines mainly received distal forces; intrusive forces were seen on the second premolars; and the molars received mesial forces. In the en-masse retraction and intrusion groups (A3, A4, and A5), incisors also received lingual and extrusive forces; canines received distal and intrusive forces; mesial and extrusive forces were seen on the second premolars; and the second molars received distal and intrusive forces. The vertical forces on the incisors did not differ significantly among groups A1, A3, and A5. However, the vertical forces on the second premolars reversed from intrusion in group A1 to extrusion in groups A3 and A5. Conclusions: With clear aligners, the "bowing effect" is seen during en-masse anterior teeth retraction and can be partially relieved by performing en-masse retraction accompanied by anterior teeth intrusion. Vertical control of incisors remained unsolved during en-masse retraction, even when intrusive activation was added to the anterior teeth.

THERMAL FRICTION TORQUE CHARACTERISTICS OF STAINLESS BALL BEARINGS

  • Lee, Jae-Seon;Kim, Ji-Ho;Kim, Jong-In
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.289-290
    • /
    • 2002
  • Stainless steel ball bearings are used in the control element drive mechanism and driving mechanisms such as step motor and gear boxes for the integral nuclear reactor, SMART. The bearings operate in pressurized pure water (primary coolant) at high temperature and should be lubricated with only this water because it is impossible to supply greases or any additional lubricant since the whole nuclear rector system should be perfectly sealed and the coolant cannot contain ingredients for bearing lubrication. Temperature of water changes from room temperature to about 120 degree Celsius and pressure rises up to 15MPa in the nuclear reactor. It can be anticipated that the frictional characteristics of the ball bearings changes according to the operating conditions, however little data are available in the literature. It is found that friction coefficient of 440C stainless steel itself does not change sharply according to temperature variation from the former research, and the friction coefficient is about 0.45 at low speed range. In this research frictional characteristics of the assembled ball bearings are investigated. A special tribometer is used to simulate the axial loading and the bearing operating conditions, temperature and pressure in the driving mechanism in the nuclear reactor. Highly purified water is used as lubricant ‘ and the water is heated up to 120 degree Celsius and pressurized to 15MPa. Friction force is monitored by the torque transducer.

  • PDF

Experience with an On-board Weighing System Solution for Heavy Vehicles

  • Radoicic, Goran;Jovanovic, Miomir;Arsic, Miodrag
    • ETRI Journal
    • /
    • 제38권4호
    • /
    • pp.787-797
    • /
    • 2016
  • Mining, construction, and other special vehicles for heavy use are designed to work under high-performance and off-road working conditions. The driving and executive mechanisms of the support structures and superstructures of these vehicles frequently operate under high loads. Such high loads place the equipment under constant risk of an accident and can jeopardize the dynamic stability of the machinery. An experimental investigation was conducted on a refuse collection vehicle. The aim of this research was to determine the working conditions of a real vehicle: the kinematics of the waste container, that is, a hydraulic rotate drum for waste collection; the dynamics of the load manipulator (superstructure); the vibrations of the vehicle mass; and the strain (stress) of the elements responsible for the supporting structure. For an examination of the force (weight) on the rear axle of a heavy vehicle, caused by its own weight and additional load, a universal measurement system is proposed. As a result of this investigation, we propose an alternative system for continuous vehicle weighing during waste collection while in motion, that is, an on-board weighing system, and provide suggestions for measuring equipment designs.

A Study on the Detection of the Drilled Hole State In Drilling (드릴 가공된 구멍의 상태 검출에 관한 연구)

  • 신형곤;김태영
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • 제12권3호
    • /
    • pp.8-16
    • /
    • 2003
  • Monitoring of the drill wear :md hole quality change is conducted during the drilling process. Cutting force measured by tool dynamometer is a evident feature estimating abnormal state of drilling. One major difficulty in using tool dynamometer is that the work-piece must be mounted on the dynamometer, and thus the machining process is disturbed and discontinuous. Acoustic transducer do not disturb the normal machining process and provide a relatively easy way to monitor a machining process for industrial application. for this advantage, AE signal is used to estimate the abnormal fate. In this study vision system is used to detect flank wear tendency and hole quality, there are many formal factors in hole quality decision circularity, cylindricity, straightness, and so of but these are difficult to measure in on-line monitoring. The movement of hole center and increasement of hole diameter is presented to determine hole quality. As the results of this experiment AE RMS signal and measurements by vision system are shorn the similar tendency as abnormal state of drilling.