• 제목/요약/키워드: Force loading

검색결과 1,289건 처리시간 0.034초

Performance analysis tool for reinforced concrete members

  • Esmaeily, Asad;Peterman, Robert J.
    • Computers and Concrete
    • /
    • 제4권5호
    • /
    • pp.331-346
    • /
    • 2007
  • A computer program was developed to analyze the non-linear, cyclic flexural performance of reinforced concrete structural members under various types of loading paths including non-sequential variations in axial load. This performance is significantly affected by the loading history. Different monotonic material models as well as hysteresis rules for confined and unconfined concrete and steel, some developed and calibrated against test results on material samples, were implemented in a fiber-based moment-curvature and in turn force-deflection analysis. One of the assumptions on curvature distribution along the member was based on a method developed to address the variation of the plastic hinge length as a result of loading pattern. Functionality of the program was verified by reproduction of analytical results obtained by others for several cases, and accuracy of the analytical process and the implemented models were evaluated against the experimental results from large-scale reinforced concrete columns tested under the analyzed loading cases. While the program can be used to predict the response of a member under a certain loading pattern, it can also be used to examine various analytical models and methods or refine a custom material model against test data.

이중 나선 구조 형상기억합금 스프링 거동 예측 (The Prediction of Nonlinear behavior of Double Coil Shape Memory Alloy Spring)

  • 이종구;안성민;조규진;조맹효
    • 한국전산구조공학회논문집
    • /
    • 제25권4호
    • /
    • pp.347-354
    • /
    • 2012
  • 형상기억합금의 복원력 및 복원량은 열 하중 및 기계적 하중으로 인한 마르텐사이트 상에서 오스테나이트 상으로의 상변이에 의한 상변형률 발생에 기인한다. 복원력 및 복원량은 초기 형상 및 하중 부여 방식에 따라 차이가 발생하는데 적절한 설계 전략없이 상변형률에만 의지한 경우 큰 복원력은 발생할 수 있어도 큰 복원량을 기대하기는 어렵다. 이는 형상기억합금의 큰 복원력과 작은 복원량 간의 비대칭성에 기인하며 형상기억합금의 효율적인 이용에 걸림돌이 된다. 본 연구에서는 형상기억합금의 상변이로 발생하는 복원량을 극대화하는 방안으로 형상기억합금 선이 이중으로 감겨있는 이중 나선 구조 형상기억합금 스프링을 제안한다. 그리고 열 하중에 의해 발생하는 복원량을 예측하고 단일 나선 구조 형상기억합금 스프링과 비교 분석하여 이중 나선 구조 형상기억합금 스프링이 단일 나선 구조 형상기억합금 스프링보다 성능 비대칭성을 보다 완화시킬 뿐만 아니라 복원력 대비보다 큰 복원량을 가짐을 보였다.

The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study

  • Ha, Seung-Ryong;Kim, Sung-Hun;Han, Jung-Suk;Yoo, Seung-Hyun;Jeong, Se-Chul;Lee, Jai-Bong;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.187-197
    • /
    • 2013
  • PURPOSE. The purpose of this study was to evaluate various core designs on stress distribution within zirconia crowns. MATERIALS AND METHODS. Three-dimensional finite element models, representing mandibular molars, comprising a prepared tooth, cement layer, zirconia core, and veneer porcelain were designed by computer software. The shoulder (1 mm in width) variations in core were incremental increases of 1 mm, 2 mm and 3 mm in proximal and lingual height, and buccal height respectively. To simulate masticatory force, loads of 280 N were applied from three directions (vertical, at a $45^{\circ}$ angle, and horizontal). To simulate maximum bite force, a load of 700 N was applied vertically to the crowns. Maximum principal stress (MPS) was determined for each model, loading condition, and position. RESULTS. In the maximum bite force simulation test, the MPSs on all crowns observed around the shoulder region and loading points. The compressive stresses were located in the shoulder region of the veneer-zirconia interface and at the occlusal region. In the test simulating masticatory force, the MPS was concentrated around the loading points, and the compressive stresses were located at the 3 mm height lingual shoulder region, when the load was applied horizontally. MPS increased in the shoulder region as the shoulder height increased. CONCLUSION. This study suggested that reinforced shoulder play an essential role in the success of the zirconia restoration, and veneer fracture due to occlusal loading can be prevented by proper core design, such as shoulder.

Wind tunnel investigation of correlation and coherence of wind loading on generic tall twin buildings in close proximity

  • Lim, Juntack;Bienkiewicz, Bogusz
    • Wind and Structures
    • /
    • 제18권4호
    • /
    • pp.443-456
    • /
    • 2014
  • A popular modern architectural form for tall buildings is two (or more) towers which are structurally linked through such features as a shared podium or sky-bridges. The fundamental features of the wind loading and the structural links of such buildings can be studied by measuring load components on the individual unlinked towers along with their correlations. This paper describes application of dual high frequency force balance (DHFFB) in a wind tunnel study of the base wind loading exerted on generic tall twin buildings in close proximity. Light models of two identical generic tall buildings of square plan were mounted on DHFFB and the base wind loading exerted on the buildings was simultaneously acquired. The effects of the relative positions of the buildings on the correlations and coherences involving loading components on each building and on the two buildings were investigated. For some relative positions, the effects of the building proximity on the wind loading were significant and the loading was markedly different from that exerted on single buildings. In addition, the correlations between the loadings on the two buildings were high. These effects have potential to significantly impact, for example, the modally-coupled resonant responses of the buildings to the aerodynamic excitations. The presented results were not meant to be recommended for direct application in wind resistant design of tall twin buildings. They were intended to show that wind loading on tall buildings in close proximity is significantly different from that on single buildings and that it can be conveniently mapped using DHFFB.

센서 동역학을 고려한 충격응답해석 (Analysis of Impact Responses Considering Sensor Dynamics)

  • B. J. Ryu;K. Y. Ahn;B. H. Kwon;I. S. Oh;Lee, G. S.
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.373.1-373
    • /
    • 2002
  • Impact is the most common type of dynamic loading conditions that give rise to impulsive forces and affects the vibrational characteristics of mechanical systems. Since the impact force and response are measured indirectly through the sensors, it is difficult to predict the impact force and acceleration. In this study, contact force model based on the Hertz law is proposed in order to predict the impact force correctly. (omitted)

  • PDF

E-Isolation : High-performance Dynamic Testing Installation for Seismic Isolation Bearings and Damping Devices

  • Yoshikazu Takahashi;Toru Takeuchi;Shoichi Kishiki;Yozo Shinozaki;Masako Yoneda;Koichi Kajiwara;Akira Wada
    • 국제초고층학회논문집
    • /
    • 제12권1호
    • /
    • pp.93-105
    • /
    • 2023
  • Seismic isolation and vibration control techniques have been developed and put into practical use by challenging researchers and engineers worldwide since the latter half of the 20th century, and after more than 40 years, they are now used in thousands of buildings, private residences, highways in many seismic areas in the world. Seismic isolation and vibration control structures can keep the structures undamaged even in a major earthquake and realize continuous occupancy. This performance has come to be recognized not only by engineers but also by ordinary people, becoming indispensable for the formation of a resilient society. However, the dynamic characteristics of seismically isolated bearings, the key elements, are highly dependent on the size effect and rate-of-loading, especially under extreme loading conditions. Therefore, confirming the actual properties and performance of these bearings with full-scale specimens under prescribed dynamic loading protocols is essential. The number of testing facilities with such capacity is still limited and even though the existing labs in the US, China, Taiwan, Italy, etc. are conducting these tests, their dynamic loading test setups are subjected to friction generated by the large vertical loads and inertial force of the heavy table which affect the accuracy of measured forces. To solve this problem, the authors have proposed a direct reaction force measuring system that can eliminate the effects of friction and inertia forces, and a seismic isolation testing facility with the proposed system (E-isolation) will be completed on March 2023 in Japan. This test facility is designed to conduct not only dynamic loading tests of seismic isolation bearings and dampers but also to perform hybrid simulations of seismically isolated structures. In this paper, design details and the realization of this system into an actual dynamic testing facility are presented and the outcomes are discussed.

Novel approach to assessing the primary stability of dental implants under functional cyclic loading in vitro: a biomechanical pilot study using synthetic bone

  • Jean-Pierre Fischer;Stefan Schleifenbaum;Felicitas Gelberg;Thomas Barth;Toni Wendler;Sabine Loffler
    • Journal of Periodontal and Implant Science
    • /
    • 제54권3호
    • /
    • pp.189-204
    • /
    • 2024
  • Purpose: This pilot study was conducted to develop a novel test setup for the in vitro assessment of the primary stability of dental implants. This was achieved by characterising their long-term behaviour based on the continuous recording of micromotions resulting from dynamic and cyclic loading. Methods: Twenty screw implants, each 11 mm in length and either 3.8 mm (for premolars) or 4.3 mm (for molars) in diameter, were inserted into the posterior region of 5 synthetic mandibular models. Physiological masticatory loads were simulated by superimposing cyclic buccal-lingual movement of the mandible with a vertically applied masticatory force. Using an optical 3-dimensional (3D) measuring system, the micromotions of the dental crowns relative to the alveolar bone resulting from alternating off-centre loads were concurrently determined over 10,000 test cycles. Results: The buccal-lingual deflections of the dental crowns significantly increased from cycle 10 to cycle 10,000 (P<0.05). The deflections increased sharply during the first 500 cycles before approaching a plateau. Premolars exhibited greater maximum deflections than molars. The bone regions located mesially and distally adjacent to the loaded implants demonstrated deflections that occurred synchronously and in the same direction as the applied loads. The overall spatial movement of the implants over time followed an hourglass-shaped loosening pattern with a characteristic pivot point 5.5±1.1 mm from the apical end. Conclusions: In synthetic mandibular models, the cyclic reciprocal loading of dental implants with an average masticatory force produces significant loosening. The evasive movements observed in the alveolar bone suggest that its anatomy and yielding could significantly influence the force distribution and, consequently, the mechanical behaviour of dental implants. The 3D visualisation of the overall implant movement under functional cyclic loading complements known methods and can contribute to the development of implant designs and surgical techniques by providing a more profound understanding of dynamic bone-implant interactions.

이방향 하중을 받는 모서리 보-기둥 접합부의 내진성능 평가 (Testing of RC Corner Beam-column Joints under Bidirectional Loading)

  • 한상환;장용석;이창석
    • 한국지진공학회논문집
    • /
    • 제24권4호
    • /
    • pp.189-196
    • /
    • 2020
  • In this study, two full-scale gravity load-designed reinforced concrete corner beam-column joints were tested by being subjected to uniand bi-directional cyclic lateral loading. The test variable was loading type: uni- or bi-directional loading. To investigate the effect of the loading type on the cyclic behavior of joint specimens, damage progression, force-deformation relation, contribution of joint deformation to total drift, joint stress-strain response, and cumulative energy dissipation were investigated. The test data suggest that bidirectional loading can amplify damage accumulation in the joint region.

벨트 하중에 따른 고령운전자의 흉곽 상해 예측 (Prediction of Thoracic Injury of Older Occupant from Belt Loading)

  • 한인석;김영은
    • 대한기계학회논문집A
    • /
    • 제33권8호
    • /
    • pp.799-806
    • /
    • 2009
  • Thoracic injury from restraint loading is the principle causative factor of death, which was shown to be particularly significant for older drivers. To characterize thoracic response to belt loading of older drivers, detailed finite element models of the adult and aged thorax were developed. The geometry of the 50th percentile adult male was chosen for the adult FE model. The thoracic FE model was validated against data obtained from results of PMHS pendulum impact tests. The quantified patterns of age-related shape and well-established material changes were applied to the adult model to develop the aged model. Belt force and chest deflection were applied to the developed two types of models. Rib and clavicle fracture risk obviously increased in the aged model. This finding showed that larger rib angle and reduced material properties of the ribcage produced more higher risk of injury in the older driver.

휨하중(荷重)을 받는 오이의 역학적(力學的) 특성(特性) (Mechanical Properties of Cucumber under Bending Force)

  • 김만수;송천호;박종민
    • Journal of Biosystems Engineering
    • /
    • 제18권1호
    • /
    • pp.30-36
    • /
    • 1993
  • Cucumbers being living biological materials are generally vulnerable to external forces, especially, bending force during the processes, because they have usually longish shape. Understanding the mechanical and viscoelastic properties of cucumber is important to analyze various characteristics which might be helpful in determining design parameters for the processing equipment such as sorting, packaging and transporting machine. The objectives of this study were to determine ultimate bending strength, deflections, and hysteresis losses for the cucumbers from the bending tests. Within the range of loading rate from 20 to 100mm/min, the ultimate bending strength of the cucumber samples were 525-630kPa at the Gyeousalicheongjang and the Baekdadagi, and 476~618kPa at the Cheongjangmadi, respectively, but the ultimate bending deflection ratio of the Cheongjangmadi showed the highest value among the tested samples. The effect of loading rate on the physical properties of the cucumber was relatively significant, all considered physical properties and degree of elasticity of the cucumber increased with the loading rate, but the hysteresis loss decreased with it.

  • PDF