• Title/Summary/Keyword: Force Standards

Search Result 334, Processing Time 0.025 seconds

The Joining Quality of High Strength Bolt, Nut and Washer Set (S10T & 10.9HRC) under the Surface Treatment Conditions (표면처리별 S10T, 10.9HRC 고장력 볼트 세트의 체결 품질 연구)

  • Choi, Youn-O;Suk, Han-Gil;Hong, Hyeon-Sun
    • Journal of Surface Science and Engineering
    • /
    • v.48 no.3
    • /
    • pp.93-99
    • /
    • 2015
  • This test focuses on the correlations between joining axial force at non-room temperature and at room temperature according to the surface treatment (Geomet, Dacro, Green Kote, Armore Galv.). The quality characteristics of the fastening axial force required by the KSB 2819 and EN14399-10 standards were discussed. Surface treatment was implemented to S10T and 10.9HRC sets of bolts under the same environmental factors. Development for the stabilization of the fastening axial force required by each standard should continually be enforced, and the fastening and storage in the field should be maintained at room temperature. Managing stabilization of torque enumerated data is required after application of surface treatment. It is concluded that, by conducting the test of applying surface treatment to effectively manage, each lot-specific rate of axial force at room temperature conditions should be maintained below the maximum 4.47%. The decline rate of axial force should be maintained under 2.15% maximum, and the standard deviation of the room temperature condition should be maintained below 0.5.

ETSI의 제25차 기술총회 참가보고

  • 김형준
    • TTA Journal
    • /
    • s.48
    • /
    • pp.172-180
    • /
    • 1996
  • 지난 4월, 향후 유럽 정보사회를 겨냥한 효율적 표준화 추진을 위해 TFIG(Task Force Implementation Group)에서 제안한 ETSI(European Telecommunications Standards Institute)의 표준화 조직구조 개편 요구에 따라 기존 ETSI의 기술 총회(TA : Technical Assembly)는 지난 25차 회의를 마지막으로 그간의 기술총회 활동을 마감하고 새로이 25명으로 구성된 이사회(Board) 체계로 변경되어진다. 이에 본 고에서는 지난 96년 10월에 열렸던 마지막 기술총회 참석 결과를 정리하고, 새로운 ETSI 조직 구조 변경에 따른 변화를 살펴보고자 한다.

  • PDF

The Code of Medical Ethics for the Korean Academy of Child and Adolescent Psychiatry: Why Is It Important? (대한소아청소년정신의학회 의료윤리규정: 왜 필요한가?)

  • Koo, Young-Jin;Hwang, Jun-Won;Lee, Moon-Soo;Yang, Young-Hui;Bang, Soo-Young;Kang, Je-Wook;Lee, Dae-Hwan;Lee, Ju-Hyun;Kwack, Young-Sook;Kim, Seungtai Peter;Noh, Kyung Sun;Park, Sung-Sook;Bahn, Geon Ho;Song, Dong-Ho;Ahn, Dong Hyun;Lee, Young Sik;Lee, Jeong-Seop;Cho, Soo-Churl;Hong, Kang-E Michael
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.27 no.1
    • /
    • pp.2-30
    • /
    • 2016
  • This article provides an overview of the developmental history and rationale of medical ethics to establish the code of ethics and professional conduct of the Korean Academy of Child and Adolescent Psychiatry (KACAP). Most medical professional organizations have their own codes of ethics and conduct because they have continuous responsibility to regulate professional activities and conducts for their members. The Ethics and Award Committee of the KACAP appointed a Task-Force to establish the code of ethics and conduct in 2012. Because bioethics has become global, the Ethics Task Force examined global standards. Global standards in medical ethics and professional conduct adopted by the World Medical Association and the World Psychiatric Association have provided the basic framework for our KACAP's code of ethics and professional conduct. The Code of Ethics of the Americal Academy of Child and Adolescent Psychiatry has provided us additional specific clarifications required for child and adolescent patients. The code of ethics and professional conduct of the KACAP will be helpful to us in ethical clinical practice and will ensure our competence in recognizing ethical violations.

A Strategy for Moving mass Systems from One Point to Another without Inducing Residual Vibration (잔류진동 없이 질량계를 한 위치에서 다른 위치로 옮기기 위한 전략)

  • Yoon, Byung Ok;;Karnopp, Bruce H.
    • Journal of KSNVE
    • /
    • v.4 no.1
    • /
    • pp.83-88
    • /
    • 1994
  • In many circumstances, it is desired to move a mass from one position to another without inducing and vibration in the mass being moved. Two such problems are considered here : the motion of a mass initiated by another mass, nd the motion of a pendulum initiated by the specified motion of its support. In each case, it is dosired that the system start at rest and come to rest in the second position. A simple strategy for the specified motion is given here. The method is motivated by engine cam-follower design. The force required to move the system in question is determined as well as the maximum value of the force required(and the times at which these forces take place).

  • PDF

Fabrication of Nb SQUID on an Ultra-sensitive Cantilever (Nb SQUID가 탑재된 초고감도 캔티레버 제작)

  • Kim, Yun-Won;Lee, Soon-Gul;Choi, Jae-Hyuk
    • Progress in Superconductivity
    • /
    • v.11 no.1
    • /
    • pp.36-41
    • /
    • 2009
  • Superconducting quantum phenomena are getting attention from the field of metrology area. Following its first successful application of Josephson effect to voltage standard, piconewton force standard was suggested as a candidate for the next application of superconducting quantum effects in metrology. It is predicted that a micron-sized superconducting Nb ring in a strong magnetic field gradient generates a quantized force of the order of sub-piconewtons. In this work, we studied the design and fabrication of Nb superconducting quantum interference device (SQUID) on an ultra-thin silicon cantilever. The Nb SQUID and electrodes were structured on a silicon-on-insulator (SOI) wafer by dc magnetron sputtering and lift-off lithography. Using the resulting SOI wafer, we fabricated V-shaped and parallel-beam cantilevers, each with a $30-{\mu}m$-wide paddle; the length, width, and thickness of each cantilever arm were typically $440{\mu}m,\;4.5{\mu}m$, and $0.34{\mu}m$, respectively. However, the cantilevers underwent bending, a technical difficulty commonly encountered during the fabrication of electrical circuits on ultra-soft mechanical substrates. In order to circumvent this difficulty, we controlled the Ar pressure during Nb sputtering to minimize the intrinsic stress in the Nb film and studied the effect of residual stress on the resultant device.

  • PDF

Pitch Measurement of 150 nm 1D-grating Standards Using an Nano-metrological Atomic Force Microscope

  • Jonghan Jin;Ichiko Misumi;Satoshi Gonda;Tomizo Kurosawa
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.3
    • /
    • pp.19-25
    • /
    • 2004
  • Pitch measurements of 150 nm one-dimensional grating standards were carried out using a contact mode atomic force microscopy with a high resolution three-axis laser interferometer. This measurement technique was named as the 'nano-metrological AFM'. In the nano-metrological AFM, three laser interferometers were aligned precisely to the end of an AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$ stabilized He-Ne laser at a wavelength of 633 nm. Therefore, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM could be used to directly measure the length standard. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement (GUM). The primary source of uncertainty in the pitch-measurements was derived from the repeatability of the pitch-measurements, and its value was about 0.186 nm. The average pitch value was 146.65 nm and the combined standard uncertainty was less than 0.262 nm. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

Tribological Properties of Tungsten Oxide Nanorods (산화 텅스텐 나노막대의 트라이볼로지 특성)

  • Kim, Dae-Hyun;Hahn, Jun-Hee;Song, Jae-Yong;Ahn, Hyo-Sok
    • Tribology and Lubricants
    • /
    • v.27 no.6
    • /
    • pp.344-350
    • /
    • 2011
  • Friction and wear behavior of tungsten oxide nanorods (TONs) was investigated using friction force microscopy(FFM) employing colloidal probes instead of conventional sharp tips. Vertically well-ordered TONs with 40 nm diameter, 130 nm length and 100 nm pitch width were synthesized on an anodic aluminium oxide substrate using two step electrochemical anodizing processes. The colloidal probe (diameter 20 ${\mu}m$) attached at the free end of tipless cantilever was oscillated(scanned) against a stationary surface of vertically aligned TONs with various scan speeds (1.2 ${\mu}m/s$, 3.0 ${\mu}m/s$ and 6.0 ${\mu}m/s$) and sliding cycles (100, 200 and 400) under normal load of 800 nN. The friction force and wear depth decreased with the increase of the scan speed. Plastically deformed thin layers were formed and sparsely deposited on the worn nonorod surface. The lower wear rate of the TONs with the longer oscillating cycles was attributed to the decreased real contact pressure due to the increase of real contact area between the colloidal probe and the TONs.

Measurement of Normal Spring Constant of Colloidal Probes for Atomic Force Microscope (원자 현미경용 콜로이드 탐침 수직 스프링 상수 측정)

  • Kim, Dae-Hyun;Kim, Min-Seok;Hahn, Junhee;Ahn, Hyo-Sok
    • Tribology and Lubricants
    • /
    • v.28 no.5
    • /
    • pp.212-217
    • /
    • 2012
  • A modified thermal noise method was proposed to measure the normal spring constants of the colloidal probes for an atomic force microscope. We used commercial tipless cantilevers (length 150, width 30, nominal k 7.4 N/m) and borosilicate spheres with a diameter of 20 to fabricate colloidal probes. The inverse optical lever sensitivity of both the tipless cantilever and colloidal probes were used to measure the normal spring constant of the colloidal probes. We confirmed the accuracy and usefulness of our method by comparing the measurement results with those obtained using the nanoforce calibrator (NFC), which reportedly has an uncertainty of 1.00%. The modified thermal method showed a good agreement (~10% difference) with the NFC, allowing us to conclude that the modified thermal method could be employed for the effective measurement of the normal spring constants of colloidal probes.

Two-Axis Force Rransducer for Measuring Flange Reaction Forces in the Tape Transport of VCR (VCR 주행장치의 2축 플랜지 반력 측정장치 개발)

  • Joo, Jin-Won;Kim, Seung-Hwan;Kim, Gap-Soon;Lee, Kyeong-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.7
    • /
    • pp.2213-2222
    • /
    • 1996
  • This paper presents the design process and evaluaation results of a two-axis force transducer for measuring flange reaction forces. A double-cantilever beam structure is used as a sensing element, and its optimal configuration is determined based on the derived strain equations to maximize the sensitivity and minimize the regid body displacements. To reduce the coupling errors between two-axis forces, strain distributions by finite elemetns analysis are utilized and the Wheaststone bridge cricuits composed of strain gages are built such that the output voltage should be zero, although strains of four strain gages are not zero. Calibration test shows that the two-azxis force transducer developed in this paper is useful in measuring flange reaction forces within the coupling error of 5.53%.

Sensing method of multi-component forces and moments using a column structure (기둥을 이용한 다축 힘/모멘트 감지 방법에 관한 연구)

  • Shin, H.H.;Kang, D.I.;Park, Y.K.;Kim, J.H.;Joo, J.W.;Kim, O.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.837-841
    • /
    • 2001
  • The column-type sensing element in building and mechanical construction parts was designed as three forces and three moments sensor by attaching strain gages approximately. Compared to conventional multi-component sensor, the designed sensor can solve the problem about low stiffness and high cost. The radius of the column was designed analytically and compared with finite element analysis. The coupling errors between components were minimized by using addition and subtraction procedure of signals. The fabricated sensor was tested by using a deadweight force standard machine and a six-component force calibration machine in Korea Research Institute of Standards and Science(KRISS). The calibration showed that the multi-component force/moment sensor had coupling error less than 19.8 % between $F_x$ and $M_y$ components, and 9.0 % in case of other components.

  • PDF