• Title/Summary/Keyword: Follicular Phase

Search Result 111, Processing Time 0.022 seconds

Monitoring the Reproductive Status of Dairy Cows by Urinary Pregnanediol Glucuronide

  • Yang, C.J.;Wu, L.S.;Liu, S.H.;Lin, J.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.4
    • /
    • pp.460-466
    • /
    • 2004
  • This study was undertaken with the aim to establish a reliable radioimmunoassay (RIA) system for urinary pregnanediol glucuronide (PdG) and to employ it for monitoring the reproductive status of dairy cows. Urine and blood samples were collected from the Holstein cows both pregnant and non-pregnant. The samples were then investigated for evaluating the relationship between progesterone ($P_{4}$) in blood and PdG in urine adjusted with or without urinary creatinine basis. Biweekly urine collection was employed for three cows in estrous and those artificially inseminated, while urine from pregnant cows was collected on a monthly basis. P_{4}$ and PdG levels were measured by enzymeimmunoassay (EIA) and RIA techniques, respectively. Our results indicated the sensitivity of PdG for RIA being 35 pg/tube and the recovery rate of 100%. Urinary creatinine concentrations also fluctuated within a day, but change at midday was not noteworthy. Regardless of the time of urination the change in concentrations of PdG was relatively smaller and did not vary significantly. The urinary PdG concentration showed periodic changes as that with serum P_{4}$ levels during the cow's estrus cycle. The correlation coefficient rose when creatinine level in urine was adjusted but the change was also not significant. The concentrations of PdG during the luteal phase were detected between 8.2 and 17.4 ng/ml, three to five times higher than that in the follicular phase. The concentration of PdG from pregnant cows (21 days after conception) was three to four times higher than in the nonpregnant cows. Our finding suggests that the determination of urinary PdG could be reliably employed for early pregnancy detection. The urinary PdG level continued to raise until 30 days pre-partum while the concentration reached its peak at 30 ng/ml, after which it started to fall 18 to 30 days before parturition and finally fell to its nadir value one week after parturition. As the correlation coefficient between the urinary PdG and serum P_{4}$ was higher than that corrected by urinary creatinine it can be suggested that the adjustment is not needed. The concentrations of urinary PdG could be maintained stably for 2 days in urine samples stored at room temperature and extended to 8 days when the samples were pretreated by boiling for 30 minutes. In conclusion urinary PdG concentration even without the need for creatinine basis adjustment can be used directly for monitoring the reproductive status of dairy cows.

The Effect of female Hormone on Knee Joint Laxity (여성 호르몬이 무릎의 느슨함(laxity)에 미치는 영향)

  • Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.1
    • /
    • pp.99-106
    • /
    • 2009
  • The purpose of this study was to determine whether hormone levels change knee laxity in healthy females. Twenty three healthy females were recruited for the study. Serum estradiol and progesterone levels were recorded three times during the subjects' menstrual cycles. The first measurements were taken between day 3 and 7 of the follicular phase and the second data collection coincided with ovulation, 24 to 48 hours after the estrogen surge detected by an ovulation predictor kits. Based on a 28 day cycle, the third data collection occurred approximately 7 days later during the luteal phase. Knee joint laxity was recorded at the same intervals with a KT 2000 arthometer. Hormone levels and phases were compared to passive knee joint laxity with multiple regression analysis. Estradiol and progesterone levels differed significantly across the three tests. Knee joint laxity increased during ovulation. Based on a multiple regression analysis, estradiol and progesterone levels predicts 77.9% to 80.9% of the laxity at 20lb and 30lb loads. An antagonistic relationship between estradiol and progesterone was found when testing for knee laxity. Serum hormone levels have moderate power in predicting knee joint laxity. Individual hormonal profiling in female athletes would allow researchers to access the structural properties of the ACL, such as the laxity which may provide beneficial information to understand female ACL injury mechanism in sports activity.

A Prospective Study of Premenstrual Dysphoric Disorder (월경전 불쾌기분장애에 관한 전향적인 연구)

  • Kim, Ji-Yun;Joe, Sook-Haeng;Kwak, Dong-Il;Park, Yong-Kyun
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.5 no.1
    • /
    • pp.52-62
    • /
    • 1997
  • This study was designed to determine the frequency of premenstrual dysphoric disorder in gynecological outpatients, and also attempted to compare premenstrual change characteristics, functional impairment due to premenstrual changes and frequency of risk factors reported by women with confirmed premenstrual changes$(PMC^+)$(n=17) and those without confirmed premenstrual changes$(PMC^-)$(n=23). Forty gynecological outpatients who complained of premenstrual discomforts were asked to complete questionnaires on menstrual history, obstetric-gynecological history, and premenstrual change and functional impairment. The women were also asked to complete a daily rating form based on DSM-IV diagnostic criteria for one menstrual cycle. Absolute severity method, effect size method and percent change method were used to assess changes between follicular phase and luteal phase. The results of the study were as follows: 1) The frequency of premenstrual dysphoric disorder according to each of the three methods was 5% for the absolute severity method, 15% for the effect size method, and 27.5% for the percent change method. 2) The frequently reported symptoms were as follow: physical symptoms(64.7%) : lethargy, easy fatigability, or marked lack of energy(41.2%) : decreased interest in usual activities(29.4%) ; and marked affective lability(23.5%). 3) There were no significant differences in onset ages of premenstrual changes, regularities of premenstrual changes and changes of severity and duration of premenstrual symptoms over time between women with and without confirmed premenstrual changes. However, women with confirmed premenstrual changes reported both physical and emotional symptoms as earliest symptoms most frequently, while women without confirmed premenstrual changes reported only physical symptoms most frequently. 4) functional impairment was significantly higher in women with confirmed premenstrual changes than those without confirmed premenstrual changes, but impairment was not severe. 5) No differences were found between women with and without confirmed premenstrual changes in risk factors including demographic data, menstrual and obstetric and gynecological history. These results suggest that the prevalence of premenstrual dysphoric disorder varies with scoring methods. The women with confirmed premenstrual changes reported physical symptoms most frequently(64.7%). functional impairment was significantly higher in women with confirmed premenstrual changes, but impairment was not severe.

  • PDF

The Effects of Ovarian Cysts on the Controlled Ovarian Hyperstimulation Cycles for In Vitro Fertilization and Embryo Transfer Program (난소 낭종이 체외수정시술을 위한 과배란유도 주기에 미치는 영향에 관한 연구)

  • Hwang, T.Y.;Kim, S.H.;Shin, C.J.;Kim, J.G.;Moon, S.Y.;Lee, J.Y.;Chang, Y.S.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.16 no.2
    • /
    • pp.205-210
    • /
    • 1989
  • To investigate the effects of ovarian cysts on the controlled ovarian hyper-stimulation cycles, 16 patients with 16 paired cycles for IVF-ET were analyzed. These patients had taken both type of cycles, i.e., with cyst(cyst group) and without cyst(control group). Mean diameter of ovarian cysts in cyst group was 18.2mm. There were no significant differences in hormone levels in early follicular phase between two groups. No significant differences were found in total dosage of hMG(IU) administered during the ovarian stimulation $843.8{\pm}123.0$ vs $891.0{\pm}129.8$, serum estradiol level (pg/ml) on the day of hCG administration($1542.8{\pm}1100.6$ vs $1567.5{\pm}1193.0$), the number of aspirated follicles $10.0{\pm}3.4$ vs $11.2{\pm}4.3$ and oocytes $5.3{\pm}3.3$ vs $6.2{\pm}3.1$, the fertilization rate(51.2 % vs 57.2 %) and the cleavage rate(40.5 % vs 52.0 %). Serum estradiol terminal patterns during COH in one group tended to be repeated in the other group. In conclusion, this study suggests that small ovarian cysts do not adversely impact on the controlled ovarian hyperstimulation parameters in IVF - ET program and the presence of small ovarian cyst without concomitant high basal serum estradiol level is not an indication of the cancellation of the controlled ovarian hyperstimulation for IVF-ET.

  • PDF

Assessment of DNA Ploidy Patterns in Connection with Prognostic Factors in Patients with Papillary Thyroid Carcinoma (유두상 갑상선암에서 예후인자와 DNA배수성의 상관관계)

  • Chung Woung-Youn;Lee Jong-Hoon;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.12 no.2
    • /
    • pp.153-160
    • /
    • 1996
  • Regardless of the prognostic factors in papillary thyroid cancer, such as sex, age, size of tumor, extent of disease, and distant metastasis, the prognosis of papillary thyroid cancer is sometimes difficult to predict from clinical and microscopic analysis alone and additional prognostic indicators are needed. Recent studies of thyroid cancer have indicated that DNA aneuploidy may be correlated to the biological behavior of malignancy and inversely correlated to the prognosis, but it still remains contraversal. We performed this study to assess DNA ploidy patterns in relation with the previously known prognostic factors in AMES scoring system and lateral neck node metastasis in papillary thyroid cancer. A series of 132 patients with papillary thyroid cancer and 80 patients with benign thyroid tumor(27 follicular adenomas and 53 adenomatous goiters) as a control group from October 1993 to Feburary 1995 were analyzed and their nuclear DNA content was measured with flow cytometry using fresh tissue specimens. DNA aneuploidy was found in 8(6.1%) in papillary cancer and 8(10%) in benign tumor. S-phase traction(SFP) and proliferative index(PI) were higher in thyroid cancers, being 2.18$\pm$4.24%, 6.34$\pm$4.94% in the papillary thyroid cancers and 1.97$\pm$2.93%, 4.44$\pm$3.80% in the benign tumors, respectively. However there was no significant difference of values between two groups(p>0.05). Among variable prognostic factors studied(age, sex, size of tun or, extent of disease, distant metastasis in AMES scoring system and lateral neck node metastasis), DNA aneuploidy was found to be common in distant metastasis(p<0.001) and in lateral neck node metastasis(p>0.035), but there was no significant difference between the high risk and low risk group according to the AMES scoring system(p<0.08). In our study, DNA aneuploidy was not valuable in determining the presence of malignancy and did not correlate to the AMES scoring system. However, follow-up study of more cases will be needed for accurate information about the DNA ploidy as a independent prognostic factor.

  • PDF

Establishment of Embryo Culture System using Co-incubated Collagen Matrix Gel with Porcine Endometrial Cells (돼지 자궁내막 상피세포와 공동배양된 Collagen Matrix Gel을 이용한 체외수정란 배양체계 확립)

  • Lee, Sang-Hee;Han, Hye-In;Hwangbo, Yong;Lee, Seunghyung;Cheong, Hee-Tae;Yang, Boo-Keun;Park, Choon-Keun
    • Reproductive and Developmental Biology
    • /
    • v.39 no.3
    • /
    • pp.49-57
    • /
    • 2015
  • In order to achieve successful in vitro production of embryo, it is necessary to establish intrauterine environment during in vitro culture. Thus, this study was investigated to establish embryo culture system using co-incubated collagen matrix gel (CM) with endometrial epithelial cells (EC). Endometrial epithelial cells were isolated from porcine endometrium at follicular phase, the cells seeded in insert dish for co-incubation with CM-coated culture dish. Then, culture media treated with/without 2.0 IU/ml hCG or 10 ng/ml $IL-1{\beta}$. After incubation for 24 h, the co-incubated insert dishes were removed from CM-coated culture dish before embryo culture. Embryos at 48 h after in vitro fertilization (IVF) were cultured on the dish for 120 h with porcine zygote medium. We determined PTGS-2 expression in the ECs, VEGF protein in co-incubated CM with EC and observed cleavage rate and blastocyst development of embryos at 168 h after IVF. In result, expression of PTGS-2 was higher at co-incubated EC with hCG and $IL-1{\beta}$ groups than EC without hCG and $IL-1{\beta}$. The VEGF protein was detected at co-incubated CM with EC, EC treated with hCG and $IL-1{\beta}$ groups higher than CM group. Also, cleavage rate was no significantly difference among all group, however, blastocyst development was significantly higher in co-incubated CM with EC treated with hCG group than un-treated groups (p<0.05). Therefore, we suggest that novel embryo culture system using co-incubated collagen matrix gel with endometrial epithelial cells treated with $IL-1{\beta}$ is beneficial and useful for enhancing the production of porcine blastocysts in vitro.

Serum Estradiol and Prolactin Levels During Hyperstimulated Menstrual Cycles (과배란 유도시 혈청 Estradiol 및 Prolactin치의 동태에 관한 연구)

  • Shin, Young-Kwan;Lee, Jin-Yong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.14 no.1
    • /
    • pp.7-17
    • /
    • 1987
  • It appears that a major determinant of the success of in vitro fertilization is the selection of the optimal follicle containing an oocyte capable of being fertilized and producing a normal pregnancy. However, the hormonal basis of oocyte maturation is not well substantiated by the as yet available informations. It has been suggested that prolactin(PRL) may stimulate the formation of an oocyte maturation inhibitor and thus inhibit the maturation of oocyte. During the hyperstimulated menstrual cycles serum estradiol($E_2$) levels are markedly elevated, and it seems justified to assume that serum prolactin levels may be elevated since estrogens are potent stimulators of prolactin secretion. This study was carried out to ascertain the effect of the elevated serum estradiol levels on the serum prolactin levels in women undergoing ovarian hyperstimulation with either hMG and/or clomiphene citrate. Serum estradiol and prolactin profiles were measured from third menatrual cycle day to ovulation or ovum aspiration day in 11 normal menstruating women and 30 women who underwent an in vitro fertilization procedure with ovarian hyperstimulation by hMG, clomiphene citrate/hMG, clomiphene citrate. Ovum aspiration was performed 36 hours after hCG administration. The day of ovum aspiration or ovulation was designated Day 0. Serum estradiol levels increased progressively during the follicular phase and this rise peaked on Day-1 at a mean concentration of 1,204${\pm}$189.0pg/ml in Group II(hMG), 1,194${\pm}$167.9pg/ml in Group III(clomiphene citrate/hMG), 1,035${\pm}$195.1pg/ml in Group IV(clomiphene citrate) respectively and on Day -2 of 336${\pm}$34.5pg/ml in Group I(normal control). The elevated estradiol levels fen rapidly after ovulation or ovum aspiration. Serum estradiol values of hyperstimulated groups(Group II, III, IV) were significantly higher than that of control group(Group I) from Day -6 to Day +1, but there was no significant difference of estradiol values among the hyperstimulated groups. Serum prolactin levels increased and peaked on Day +1 at a mean concentration of 60.8${\pm}$14.4ng/ml in Group II, 34.2${\pm}$7.0ng/ml in Group III, 30.1${\pm}$5.7ng/ml in Group IV respectively, but no significant elevation was observed in Group I. Levels of estradiol and prolactin can be positively and significantly correlated in the hyperstimulated groups. However, the increase of serum prolactin levels in hMG group was significantly higher than those in clomiphene citrate/hMG or clomiphene citrate group.

  • PDF

Automatic Notification System for Nuclear Medicine Blood Test (핵의학 혈액 검사의 경고치 자동통보 시스템)

  • Sim, Seong-Jae;Yoon, Pil-Young;Lim, Soo-Yeon;Cheon, Jun-Hong;Shin, Young-Kyoon;Yu, Seon-Hui;Cho, Si-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.159-164
    • /
    • 2009
  • Purpose: The automatic notification system for alarm values on blood tests conducted by this hospital is designed to immediately inform the attending physician of the result of a blood test, to help the relevant patient to promptly receive proper treatment, and furthermore, to reduce the likelihood of a fatal influence to the patient. From 2004, the clinical pathology department of this hospital has been operating an automatic notification system for blood tests, in relation to the items of WBC, Hb, Plt, PB cell morphology, Malaria, PT, aPTT, BT, fibrinogen, Ca, K, Na, Cl, Mg, Glucose, Ketone, Digoxin, PKU, Homocystinuria, 17-OHP, Neonatal TSH, and Galactosemia. Recently, the blood test room of the nuclear medicine department has been operating an automatic notification system for the alarm values of a blood test, in relation to three items of TSH, FT4, and 17-${\alpha}$-OH-PGR, and the details of its operation will be described here. Materials and Methods: The subjects were newborn babies that were receiving TSH, FT4, and $17{\alpha}$-OH-PGR prescriptions from February $19^{th}$ to May $11^{st}$, 2009, and who met with the following criteria: N2340 Thyroid-Stimulating Hormone: >$10{\mu}IU/mL$ (Reference value: 0.4~5.0). N2360 Free-Thyroxine: <$0.8{\mu}g/dL$ (Reference value: 0.8~1.9), N2444 $17{\alpha}$-OH-Progesterone: >$30\;{\mu}g/mL$ (Reference value: Male (0.6~3.42), Female follicular phase (0.19~1.8). The automatic notification system was operated by entering test items, relevant treatment departments, and standard values for reporting alarm values into the OCS program, and then transmitting results that met with the input conditions to the PDAs of the prescription and the attending physician by SMS. Results: Reporting an alarm value of the nuclear medicine blood test, which can have a fatal influence on the lives of patients, will help cure patients, improve the quality of the test, and furthermore, will increase the patient's satisfaction with the prescription and treatment of the test.

  • PDF

GnRH Antagonist Versus Agonist Flare-up Protocol in Ovarian Stimulation of Poor Responder Patients (저 반응군의 체외수정시술을 위한 과배란유도에 있어 GnRH Antagonist 요법과 GnRH Agonist Flare Up 요법의 효용성에 관한 연구)

  • Ahn, Young-Sun;Yeun, Myung-Jin;Cho, Yun-Jin;Kim, Min-Ji;Kang, Inn-Soo;Koong, Mi-Kyoung;Kim, Jin-Yeong;Yang, Kwang-Moon;Park, Chan-Woo;Kim, Hye-Ok;Cha, Sun-Hwa;Song, In-Ok
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.34 no.2
    • /
    • pp.125-131
    • /
    • 2007
  • Objective: The aim of this study was to compare GnRH antagonist and agonist flare-up treatment in the management of poor responder patients. Methods: One hundred forty-four patients from Jan. 1, 2002 to Aug. 31, 2005 undergoing IVF/ICSI treatment who responded poorly to the previous cycle (No. of oocyte retrieved$\leq$5) and had high early follicular phase follicle stimulating hormone (FSH>12 mIU/ml were selected. Seventy-five patients received agonist flare-up protocol and 71 patients received antagonist protocol. We analyzed the number of oocytes retrieved, number of good embryos (GI, GI-1), total dose of hMG administered, implantation rate, cycle cancellation rate, pregnancy rate, live birth rate. Results: The cancellation rate was high in antagonist protocol (53.5% vs. 30.1%). The number of oocyte retrieved, the number of good embyos were high in agonist flare-up group. There was no statistical difference between GnRH agonist flare up protocol and GnRH antagonist protocol in implantation rate (14.5%, 10.1%), clinical pregnancy rate per transfer (29.4%, 21.2%) and live birth rate per transfer (21.6%, 18.2%). Although the result was not statistically significant, GnRH agonist flare up group showed a nearly doubled pregnancy rate and live birth rate per initial cycle than GnRH antagonist group. Conclusions: The agonist flare-up protocol appears to be slightly more effective than the GnRH antagonist protocol in implantation rate, pregnancy rate, live birth rate but shows statistically no significance. Agonist flare-up protocol improved the ovarian response in poor responders. However, based of the result of the study, we can expect improved ovarian response in poor responders by GnRH agonist flare up protocol.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF