• 제목/요약/키워드: Fog formation

검색결과 27건 처리시간 0.017초

산성안개가 내후성강재의 녹형성 및 피로강도에 미치는 영향 (Effect of Acid Fog on Rust Formation and Fatigue Strength of Weathering Steel)

  • 김민건;구은회
    • 산업기술연구
    • /
    • 제22권B호
    • /
    • pp.13-20
    • /
    • 2002
  • The purpose of this study is to investigate the effect of acid fog on the rust formation behavior of weathering steel (SMA50) which is used in uncoated bridges. Weathering steel didn't form the passive film under the environment of acid fog(pH5,6), whereas the environment of distilled water formed the protective oxide film. Therefore, the construction of weathering steel under the environment extremely exposed to SOx and NOx which are the main compositions of acid fog is not adequate. Fatigue limits of weathering steel under acid fog environment are remarkably decreased as compared with environment of distilled water. The corrosive constituents in acid fog has piled up the corrosion products on specimen surface and generated the corrosion pits. Because of the high stress concentration arising at this corrosion pit, relatively low fatigue limits were obtained for acid fog specimens.

  • PDF

무도장 교량에 사용되는 내후성강재의 부식 및 피로거동에 미치는 산성안개의 영향 (Effect of Acid Fog on Rust Formation and Fatigue Behavior of Weathering Steel Used in Un-Coated Bridge)

  • 김민건
    • 대한기계학회논문집A
    • /
    • 제32권1호
    • /
    • pp.13-20
    • /
    • 2008
  • The purpose of this study is to investigate the effect of acid fog on the rust formation behavior of weathering steel (SMA50) which is used in un-coated bridges. Weathering steel didn't form the passive film under the environment of acid fog(pH5,6), whereas the environment of distilled water formed the protective oxide film. Therefore, the construction of weathering steel under the environment extremely exposed to SOx and NOx which are the main compositions of acid fog is not adequate. Fatigue limits of weathering steel under acid fog environment are remarkably decreased as compared with environment of distilled water. The corrosive constituents in acid fog has piled up the corrosion products on specimen surface and generated the corrosion pits. Because of the high stress concentration arising at this corrosion pit, relatively low fatigue limits were obtained for acid fog specimens.

국지풍이 내륙의 안개발생에 미치는 영향 (Influence of Local Wind on Occurrence of Fog at Inland Areas)

  • 심화남;이영희
    • 대기
    • /
    • 제27권2호
    • /
    • pp.213-224
    • /
    • 2017
  • We have examined the influence of local wind on occurrence of fog at two inland areas, Chuncheon and Andong, in Korea. The surrounding topography of two inland areas shows significant difference: Chuncheon is located in the basin surrounded by ridges with north-south axis while Andong is located in the valley between the ridges with east-west axis. Occurrence of fog shows maximum in October at both sites but high occurrence of fog at Chuncheon is also noted in the winter. Occurrence of fog at Andong in October is much larger than that at Chuncheon. High occurrence of fog in October is due to favorable synoptic condition for fog formation such as weak wind, clear day and small depression of the dew-point. Fog occurrence at Chuncheon is closely related to very weak wind condition where wind speed is less than $0.5m\;s^{-1}$. The weak wind at Chuncheon in winter is due that pressure driven channeling wind (southerly) cancels out partly downslope northerly flow during nighttime. On the other hand, fog at Andong occurs well when wind is southeasterly which is thermally forced flow during nighttime. Southeasterly provides cold, moist air from the narrow valley to Andong during nighttime, leading to favorable condition for formation of fog.

정규관측자료와 GPS 연직누적 수증기량을 이용한 안개에 대한 비교연구 (Comparative Research of Fog Using the Regular Observation and GPS Integrated Water Vapor)

  • 이재원;조정호;백정호;박종욱;박지업
    • 대기
    • /
    • 제18권4호
    • /
    • pp.417-427
    • /
    • 2008
  • In this paper, we analyzed the physical and thermodynamic characteristics of fog by using the integrated water vapor (IWV) from Global Positioning System (GPS) networks and the regular observation data of meteorological stations in GPS sites. The cases of a radiation and an advection fog were selected as samples, the conversions of water substance from the water vapor to cloud water in fog were detected by the Bulk Water-Continuity Model, and the pattern analysis is adapted on GPS IWV, temperature, wind and relative humidity. Under the specific hypothesis (saturation and stable), GPS IWV could detect quantitatively the phase changing between the water vapor and cloud water content with condensation/evaporation during the formation and dissipation of fog. After it reaches to the saturation, the relative humidity can be a limited indicator for fog. However, GPS IWV can detect the status change of fog even after the saturation. It has indicated that GPS IWV could be a new observing technique for the processes of the fog formation and the dissipation.

한국남서연안해역의 저수온 출현과 안개 형성과의 관련성에 관한 연구 (A Study on Relationship between Cold Water Appearance and Fog Formation in the Southwest Coastal Waters of Korea)

  • 윤종휘;정희동;조규대;이충일
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2004년도 추계학술발표회
    • /
    • pp.123-127
    • /
    • 2004
  • It is known that cold water appears and fog frequently forms in the southwest coastal waters of Korea in summer. The authors investigate the time and place. of cold water existence, and also whether the cold water affects the occurrence of fog formation. As a result, cold water begins to appear around Daeheugsando at the early summer. It gets colder with times and cold water area moves toward southwest of Jindo in mid-summer, then disappears in this area around mid-Oct. Fog mostly forms in April through August and most frequently occurs at Chukdo(Jindo) where sea surface temperature shows lower than that at the adjacent area. Accordingly it is taken that the cold water is considerably contributed to form the dense and frequent fog around Jindo area.

  • PDF

Development of Polymeric Water Absorbent Film(PWAF) for the Collection of Size-classified Fog Droplets

  • Ma, Chang-Jin;Mikilo-kasahara;Park, Kum-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제17권E1호
    • /
    • pp.17-24
    • /
    • 2001
  • For the purpose of collecting fog droplets as a function of size a new sampling method was developed in this study. Formation of 100$\pm$10㎛ thickness of polymeric water absorbent film (PWAF) on a nuclepore filter could be successfully realized. Also applicability of particle induced X-ray emission (PIXE) method to the chemical analysis of size-segregated fog droplets collected on PWAF was examined experimentally with synthetic fog droplets generated from a nebulizer. Absorption capacity of S-PAAS polymeric water absorbent shows marked decreases in the range less than 1 wt% and slight decrease between 1 and 3.5 wt% of every salt concentration. Dependency of absorption capacity on pH shows the maximum at pH 7. No apparent peak which can influence the quantitative analysis of elements dissolved and suspended in fog droplets was found at PIXE spectrum of PWAF blank. PWAF kept the original shape without rupture under the PIXE analytical conditions of beam intensity for 10 to 60 nA and irradiation time of 4∼5 min. It should be said that the proposed new technique in the work is helpful to get more detailed information of fog droplets, to clarify the fog formation processes, and to develop a model of acid deposition process.

남한에서의 안개 사례별 목측과 시정계 계측의 시정 특성 비교 (A Comparative Study on the Visibility Characteristics of Naked-Eye Observation and Visibility Meters of Fog over South Korea)

  • 이현경;서명석
    • 대기
    • /
    • 제28권1호
    • /
    • pp.69-83
    • /
    • 2018
  • Most of the researches on fog in South Korea have been done based on the naked-eye observation but the number of observation sites is just 22. Considering the localities of fog and various durations, it is essential to utilize more than 250 visibility meters that measure visibility every minute. In this study, the visibility characteristics of visibility meters were compared with that of the naked-eye observation using one year data, 2016, and radiation fog and advection fog cases were analyzed in detail. The concordance rate of the two data set was 0.96~0.97, but discordance rate was 0.19~0.47. In general, visibility meters observed fog more frequently than naked-eye. The correlation between two data sets is clearly dependent on the visibility and geographic locations (fog/thick fog (< 100 m) of inland: 0.86/0.61; fog/thick fog: 0.65/0.73 of island/coastal site). In both fog cases, the fog events observed by naked-eye were consistently detected by visibility meters, and visibility meters clearly well detected very short fog/thick fogs. Formation and dissipation time of fog for the fog cases were similar but fog duration by visibility meters was shorter because of exclusion of temporary dissipated time. In addition, the visibility meters showed a detailed distribution of fog events that occurred simultaneously over South Korea. It would be useful to analyze the spatial and temporal characteristics of, in particular, thick fog using visibility meters. However, more works are needed for the filtering criteria for analyzing fog using visibility meters alone.

한국 남서연안해역의 저수온 출현과 안개 형성과의 관련성에 관한 연구 (A Study on Relationship between Cold Water Appearance and Fog Formation in the Southwest Coastal Waters of Korea)

  • 윤종휘;정희동;조규대;김동선;이은방
    • 한국항해항만학회지
    • /
    • 제29권6호
    • /
    • pp.583-588
    • /
    • 2005
  • 하계 한국 남서연안 해역에는 저온수가 나타나고 안개가 자주 형성되는 것으로 알려져 있다. 본 연구에서는 저온수의 출현시기 및 장소와 이 해역에서 형성되는 안개에 미치는 저온수의 영향에 대해 조사${\cdot}$분석하였다. 그 결과, 저수온역은 초여름 대흑산도 부근해역에서 나타나기 시작하여, 이것은 점차 이동하여 7월 말${\~}$8월 초 진도 남서쪽 해역에 위치하고, 그 후 10월 중순경 이 해역에서 소멸된다. 그리고 이 해역에서는 주로 4${\~}$8월에 안개가 발생하는데, 특히 인근해역에 비해 해면온도가 현저하게 낮은 진도해역에서 안개 발생빈도가 높은 것으로 보아, 이 해역에 나타나는 저온수가 안개의 형성에 상당한 영향을 끼치는 것으로 사료된다.

안개 생성 메커니즘 기반 안개 유형 분류 및 한반도 지역내 발생 특성 분석 (Fog Type Classification and Occurrence Characteristics Based on Fog Generation Mechanism in the Korean Peninsula)

  • 김은지;박순영;유정우;이순환
    • 한국환경과학회지
    • /
    • 제32권12호
    • /
    • pp.883-898
    • /
    • 2023
  • To investigate the occurrence characteristics and types of fog on the Korean Peninsula over the past three years (2020 to 2022), data from 96 synoptic meteorological observatories and 21 ocean buoys were collected and analyzed. We included precipitation fog, which occurs after precipitation events, and cloud-base lowering fog, which is caused by the development of lower-level clouds, with a total six subtypes of fog. In the case of cloud-base lowering fog, the occurrence frequency at 2.6% was not high at 2.6%, but the duration of low visibility below 200 m was very long at 6.9 hours. The seasonal frequency of fog is low in spring and winter, high in summer over islands and coastal areas, and high in autumn over inland areas. The frequency of inland fog, which is characterized by high radiation fog and dense fog, requires attention in terms of transportation safety, with an occurrence time of 0500 LST to 1000 LST. Therefore, systematic analysis of precipitation fog and cloud-base lowering, as well as radiation and advection fog, is required in the analysis of recognizing fog as a disaster and causing transportation disorders.

낙동강 유역 안개 발생시 기상 특성: 강정고령보 사례를 중심으로 (Atmospheric Characteristics of Fog Incidents at the Nakdong River : Case Study in Gangjeong-Goryeong Weir)

  • 박준상;임윤규;김규랑;조창범;장준영;강미선;김백조
    • 한국환경과학회지
    • /
    • 제24권5호
    • /
    • pp.657-670
    • /
    • 2015
  • Visibility and Automatic Weather System(AWS) data near Nakdong river were analyzed to characterize fog formation during 2012-2013. The temperature was lower than its nearby city - Daegu, whereas the humidity was higher than the city. 157 fog events were observed in total during the 2 year period. About 65% of the events occurred in fall (September, October, and November) followed by winter, summer, and spring. 94 early morning fog events of longer than 30 minutes occurred when south westerly wind speed was lower than 2 m/s. During these events, the water temperature was highest followed by soil surface and air temperatures due to the advection of cold and humid air from nearby hill. The observed fog events were categorized using a fog-type classification algorithm, which used surface cooling, wind speed threshold, rate of change of air temperature and dew point temperature. As a result, frontal fog observed 6 times, radiation 4, advection 13, and evaporation 66. The evaporation fog in the study area lasted longer than other reports. It is due to the interactions of cold air drainage flow and warm surface in addition to the evaporation from the water surface. In particular, more than 60% of the evaporation fog events were accompanied with cold air flows over the wet and warm surface. Therefore, it is needed for the identification of the inland fog mechanism to evaluate the impacts of nearby topography and land cover as well as water body.