• 제목/요약/키워드: Focusing Mode

검색결과 237건 처리시간 0.021초

Antisymmetric-Symmetric Mode Conversion of Ultrasonic Lamb Waves and Negative Refraction on Thin Steel Plate

  • Sung, Jin Woo;Kim, Young H.
    • 비파괴검사학회지
    • /
    • 제33권3호
    • /
    • pp.270-275
    • /
    • 2013
  • In this study, focusing of ultrasonic Lamb wave by negative refraction with mode conversion from antisymmetric to symmetric mode was investigated. When a wave propagates backward by negative refraction, the energy flux is antiparallel to the phase velocity. Backward propagation of Lamb wave is quite well known, but the behavior of backward Lamb wave at an interface has rarely been investigated. A pin-type transducer is used to detect Lamb wave propagating on a steel plate with a step change in thickness. Conversion from forward to backward propagating mode leads to negative refraction and thus wave focusing. By comparing the amplitudes of received Lamb waves at a specific frequency measured at different distance between transmitter and interface, the focusing of Lamb wave due to negative refraction was confirmed.

B-mode 초음파 진단장치에서 합성 집속방법에 의한 해상도 증대에 관한 연구 (A Study on the Improving the Resolution using Synthetic Focusing in B-mode Ultrasound Imaging System)

  • 배무호;정목근
    • 한국음향학회지
    • /
    • 제17권6호
    • /
    • pp.14-22
    • /
    • 1998
  • 기존의 널리 사용되는 초음파 영상진단기에서는 수신집속은 모든 점에 대해 행하는 것이 가능하지만 송신접속은 미리 정해진 수 개의 점에 대해서만 행하는 한계가 있다. 본 논문에서는 영상화할 대상이 정지해 있거나 매우 느리게 움직이는 경우에 한하여, 송신음장 의 집속은 합성집속방법(synthetic focusing)을 사용하고, 수신집속은 동적 집속(dynamic receive focusing)을 이용함으로써 모든 영상점에서 송수신 집속하여 측방향 해상도를 향상 시키는 방법을 제안하였다. 컴퓨터 시뮬레이션 결과 초점깊이에서와 같은 해상도를 유지하 는 음장거리(fields of depth)가 기존의 방법에 비하여 월등히 우수하였으며, 3.5MHz의 선형 배열변환기를 이용하여 펜텀 영상에 대한 실험 결과도 모든 영상 깊이에서 측방향 해상도가 기존의 B-mode의 영상보다 우수하였다.

  • PDF

초소형 전자 렌즈의 전자 광학적 분석 (Electro-optical analysis of a miniaturized electrostatic electron lens)

  • 김호섭;김대욱;김영철;최상국;김대용
    • 한국광학회지
    • /
    • 제14권2호
    • /
    • pp.194-199
    • /
    • 2003
  • FCM(Fast moving least square reproducing kernel point collocation method) 방식의 simulation tool을 이용하여 전기장으로 구동되는 초소형 전자 렌즈의 구동 특성을 조사·분석하였다. Einzel 렌즈의 retarding mode와 accelerating mode구동에서 포텐셜 분포는 유사하지만, electric field strength는 서로 다른 방향을 갖게 되어 서로 다른 형태의 전자 궤적을 보인다. 동일한 working distance에서 accelerating mode로 구동되는 전자렌즈는 retarding mode로 구동되는 경우보다 매우 높은focusing 전압을 필요로 한다.

수학적 전개에 의한 픽업 액추에이터의 진동 분석 (A Mathematical Approach for Vibration Analysis of an Pickup Actuator)

  • 이경택
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.792-798
    • /
    • 2012
  • This study shows the vibration characteristics of an actuator with six wire-suspensions, used in optical pickups of optical disc drives (ODDs). In this paper, the vibration characteristics of this beam structure is induced mathematically. To obtain vibration modes of focusing direction, the vibration analysis is achieved in lateral and longitudinal directions of the structure. The accuracy of induced vibration characteristics is proved by comparing mode frequencies with a finite element analysis. Finally, it is shown that mode shapes can be modified by changing design parameters in mathematical expressions.

  • PDF

위상배열 유도초음파 검사의 이론적 고찰 (The Theoretical Investigation of Phased Array Guided Waves)

  • 이재선;조윤호
    • 비파괴검사학회지
    • /
    • 제31권4호
    • /
    • pp.367-373
    • /
    • 2011
  • 유도초음파를 활용한 진단 기술은 기존의 체적파를 이용한 진단 기법과 달리 장거리 진단의 장점 때문에 널리 사용된다. 대부분의 산업현장에서는 배관이 코팅되어 있거나 땅속이 묻혀있다. 이러한 경우 감쇠의 영향으로 기존의 방식으로는 진단에 어려움이 있다. 본 연구에서는 배관에서 전파되는 유도초음파 전파 모드별 음장을 직교모드확장기법을 이용하여 계산하였다. 단일 탐촉자에 의해 전파되는 유도초음파의 음장과 다중 탐촉자 모델링을 바탕으로 배관에서 전파되는 음장 특성을 해석하기 위해 유도초음파 모드별 집속 기술이 사용되었다. 추가적으로 배관에서 전파되는 유도초음파를 가진하는 탐촉자의 개수에 따른 집속 민감도가 종형 모드와 휨형 모드를 이용하여 계산되었다. 본 연구를 통하여 단일 탐촉자에 의해 가진된 유도초음파와 집속 알고리즘을 적용한 다중 탐촉자에 의해 가진된 음장을 비교하여 높은 에너지가 접속 되는 것을 확인 하였다.

근골격계 초음파의 기판 조절 입문: B Mode와 Doppler (Introduction to Knobology Focusing on B Mode and Doppler Setting in Musculoskeletal Ultrasound)

  • 민경훈
    • Clinical Pain
    • /
    • 제20권1호
    • /
    • pp.7-14
    • /
    • 2021
  • Musculoskeletal ultrasound has evolved as the essential tool to diagnose and guide intervention procedures in people with neuromusculoskeletal conditions. Image optimization and understanding device operations are core components for ultrasound guided intervention procedure training. All ultrasound machines share the common operative features and there are various buttons for the features in the device control panel. Ultrasound "knobology" refers to the thorough understanding of imaging optimization. This review addressed basic information for the transducers, depth setting, gain and focus control, different modes focusing on brightness and doppler modes.

초소형 광드라이브용 포커싱 액츄에이터 설계 연구 (A Study on the Focusing Actuator of Ultra Small Optical Drive)

  • 손도현;홍삼열;김진아;김영중;최인호;김진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.234-238
    • /
    • 2003
  • Ultra small optical drive or PCMCIA type needs a focusing actuator because or applying Blue Laser and enhancing compatibility according to disk physical specification. Based on this need, this paper presents a novel focusing actuator adapted for ultra small optical drive of PCMCIA type. The focusing actuator using Lorenz force generated consists of coil, magnets and plate springs of pivoting. The design issues of the focusing actuator are the flexibility to focus direction, the rigidity to track direction and the higher natural mode of the moving part. For settling these Issues, this paper present mechanical design, computer simulations and test results of the realized focusing actuator. Finally, suitability and usefulness of the focusing actuator was demonstrated by the comparison of simulations and test results in a view of the possibility adapted for ultra small optical drive.

  • PDF

Impact Localization for a Composite Plate Using the Spatial Focusing Properties of Advanced Signal Processing Techniques

  • Jeong, Hyunjo;Cho, Sungjong
    • 비파괴검사학회지
    • /
    • 제32권6호
    • /
    • pp.703-710
    • /
    • 2012
  • A structural health monitoring technique for locating impact position in a composite plate is presented in this paper. The method employs a single sensor and spatial focusing properties of time reversal(TR) and inverse filtering(IF). We first examine the spatial focusing efficiency of both approaches at the impact position and its surroundings through impact experiments. The imaging results of impact localization show that the impact location can be accurately estimated in any position of the plate. Compared to existing techniques for locating impact or acoustic emission source, the proposed method has the benefits of using a single sensor and not requiring knowledge of anisotropic material properties and geometry of structures. Furthermore, it does not depend on a particular mode of dispersive Lamb waves that is frequently used in other ultrasonic testing of plate-like structures.

Nonlinear Time Reversal Focusing and Detection of Fatigue Crack

  • Jeong, Hyun-Jo;Barnard, Dan
    • 비파괴검사학회지
    • /
    • 제32권4호
    • /
    • pp.355-361
    • /
    • 2012
  • This paper presents an experimental study on the detection and location of nonlinear scattering source due to the presence of fatigue crack in a laboratory specimen. The proposed technique is based on a combination of nonlinear elastic wave spectroscopy(NEWS) and time reversal(TR) focusing approach. In order to focus on the nonlinear scattering position due to the fatigue crack, we employed only one transmitting transducer and one receiving transducer, taking advantage of long duration of reception signal that includes multiple linear scattering such as mode conversion and boundary reflections. NEWS technique was then used as a pre-treatment of TR for spatial focusing of reemitted second harmonic signal. The robustness of this approach was demonstrated on a cracked specimen and the nonlinear TR focusing behavior is observed on the crack interface from which the second harmonic signal was originated.

Kerr Medium에서의 단독 빔의 간섭에 관한 시뮬레이션 (Simulation of Solitary Beam Interaction in Kerr Media)

  • 심형관
    • 한국시뮬레이션학회논문지
    • /
    • 제12권2호
    • /
    • pp.75-89
    • /
    • 2003
  • This paper describe numerical experiments with solitary beams in a self focusing Kerr medium with fast response. Through formal analogies, it compare this results on the phase sensitivity of beam collision with known predictions about one dimensional soliton interaction. For incoherent oblique beam interaction, there occurs a non-periodic coupled-mode type transfer of energy, resulting in complete transmission each beam through the other one.

  • PDF