• Title/Summary/Keyword: Focused light array

Search Result 14, Processing Time 0.02 seconds

Super multi-view 3-D display system based on focused light Array using reflective vibrating scanner array (ViSA)

  • Ho-In Jeon;Nak-Hee Jung;Jin-San Choi;Young Jung;Young Huh
    • Broadcasting and Media Magazine
    • /
    • v.6 no.2
    • /
    • pp.84-101
    • /
    • 2001
  • In this paper, we present a primitive system design of a super multi-view(SMV) 3-D display system based on a focused light array(FLA) concept using reflective vibrating scanner array(ViSA). The parallel beam scanning using a vibrating scanner array is performed by moving left and right an array of curvature-compensated mirrors or diamond-ruled reflective grating attached to a vibrating membrane. The parallel laser beam scanner array can replace the polygon mirror scanner which has been used in the SMV 3-D display system based on the focused light array(FLA) concept proposed by Kajiki at TAO(Telecommunications) Advancement Organization). The proposed system has great advantages in the sense that it requires neither huge imaging optics nor mechanical scanning pals. Some mathematical analyses and fundamental limitations of the proposed system are presented. The proposed vibrating scanner array, after some modifications and refinements, may replace polygon mirror-based scanners in the near future.

  • PDF

Design and Lithographic Fabrication of Elliptical Zone Plate Array with High Fill Factor

  • Anh, Nguyen Nu Hoang;Rhee, Hyug-Gyo;Ghim, Young-Sik
    • Current Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 2021
  • An elliptical zone plate (EZP) array is important in off-axis optical systems because it provides two advantages. First, the residual beam and the main source are not focused in the same direction and second, the light from the observation plane is not reflected back towards the beam source. However, the fill factor of the previous EZP array was about 76% which was a little low. Hence, this EZP array could not collect the maximum amount of illumination light, which affected the overall optical performance of the lens array. In this study, we propose a new EZP array design with a 97.5% fill factor used in off-axis imaging system for enhancement of brightness and contrast. Then, direct laser lithography was used to fabricate the high fill factor EZP array by moving the XY linear stage of the system in a zigzag motion. The imaging properties of the proposed EZP array were experimentally verified at the focal plane and compared with the previous model.

Influence of Micro-Pattern Replication Ratio of Injection-Molded Light Guide Plate on Optical Aspect of LCD (도광판의 미세 패턴 사출 전사성이 LCD 광특성에 미치는 영향에 관한 해석적 연구)

  • Hong, J.P.;Joo, B.Y.
    • Transactions of Materials Processing
    • /
    • v.21 no.2
    • /
    • pp.126-130
    • /
    • 2012
  • Accurate optical texturing of light guide plate over the entire surface area is an important technical issue in LCD TV industry. Injection molding process has the potential to produce large light guide plates having highly efficient optical textures such as micro-prism array. This study is focused on the effect of the degree of replication of the micro texture of the 40" injection molded light guide plates on the overall optical performance of the display panel. Measured replication ratios of the micro-textures formed with three different types of injection molding process were considered in the modeling of prismatic micro segment array. Optical simulation was conducted and results were discussed.

Super Multi-View 3-D Display System using Vibrating Scanner Array(ViSA)

  • Jeon, Ho-In;Jung, Nak-Hee;Choi, Jin-San;Kang, Yo-Seek;Choi, Se-Ha;Shin, Sang-Hun;Son, Jung-Yung
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.37-42
    • /
    • 2000
  • In this paper, we propose a super multi-view (SMV) 3-D display system using a vibrating scanner array (ViSA). The parallel beam scanning using a vibrating scanner array is performed by moving back and forth an array of curvature-compensated mirrors attached to two vibrating membranes. The parallel laser beam scanner array can replace the polygon mirror scanner which has been used in the SMV 3-D display system based on the focused light array(FLA) concept. The proposed system has great advantages in the sense that it requires neither huge imaging optics normechanical scanning parts. Some mathematical analyses and fundamental limitations of the proposed system are presented. The proposed vibrating scanner array, after some modifications and refinements, will replace polygon mirror-based scanners in the near future.

Active Focusing of Light in Plasmonic Lens via Kerr Effect

  • Nasari, Hadiseh;Abrishamian, Mohammad Sadegh
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.305-312
    • /
    • 2012
  • We numerically demonstrate the performance of a plasmonic lens composed of an array of nanoslits perforated on thin metallic film with slanted cuts on the output surface. Embedding Kerr nonlinear material in nanoslits is employed to modulate the output beam. A two dimensional nonlinear-dispersive finite-difference time-domain (2D N-D-FDTD) method is utilized. The performance parameters of the proposed lens such as focal length, full-width half-maximum, depth of focus and the efficiency of focusing are investigated. The structure is illuminated by a TM-polarized plane wave and a Gaussian beam. The effect of the beam waist of the Gaussian beam and the incident light intensity on the focusing effect is explored. An exact formula is proposed to derive electric field E from electric flux density D in a Kerr-Dispersive medium. Surface plasmon (SPs) modes and Fabry-Perot (F-P) resonances are used to explain the physical origin of the light focusing phenomenon. Focused ion beam milling can be implemented to fabricate the proposed lens. It can find valuable potential applications in integrated optics and for tuning purposes.

Display 특성 향상을 위한 MLA 광소자 개발 연구

  • Jeong, Han-Uk;Kim, Gwang-Yeol;Lee, Gong-Su;Sin, Seong-Uk;Park, Hong-Jin;Choe, Byeong-Deok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.199-199
    • /
    • 2009
  • Recently, polymeric microlens arrays have become important elements in many applications. Microlens arrays have been used to enhance luminance efficiency and luminance power efficiency of light-emitting diodes (LEDs) and organic LEDs. Many processes for fabrication of microlens array are studied. Though the MLA has been fabricated by electroformed mold, LIGA process and reflow method, these methods were required masks, multiple process steps and post processing. In this paper, we proposed rapid and direct UV laser direct fabrication process using colorless liquid photopolymer, NOA60 for polarization activated microlens. The microlens arrays are formed on the NOA60 on glass, after the focused laser energy was irradiated to the material. The diameter of MLA was varied from 42 to 88 ${\mu}m$, and the height from 0.9 to 1.6 ${\mu}m$. The MLA fabricated using NOA60 shows more then 85% transmittance as well as good hardness for optical module.

  • PDF

Application of Three-Dimensional Light Microscopy for Thick Specimen Studies

  • Rhyu, Yeon Seung;Lee, Se Jeong;Kim, Dong Heui;Uhm, Chang-Sub
    • Applied Microscopy
    • /
    • v.46 no.2
    • /
    • pp.93-99
    • /
    • 2016
  • The thickness of specimen is an important factor in microscopic researches. Thicker specimen contains more information, but it is difficult to obtain well focused image with precise details due to optical limit of conventional microscope. Recently, a microscope unit that combines improved illumination system, which allows real time three-dimensional (3D) image and automatic z-stack merging software. In this research, we evaluated the usefulness of this unit in observing thick samples; Golgi stained nervous tissue and ground prepared bone, tooth, and non-transparent small sample; zebra fish teeth. Well focused image in thick samples was obtained by processing z-stack images with Panfocal software. A clear feature of neuronal dendrite branching pattern could be taken. 3D features were clearly observed by oblique illumination. Furthermore, 3D array and shape of zebra fish teeth was clearly distinguished. A novel combination of two channel oblique illumination and z-stack imaging process increased depth of field and optimized contrast, which has a potential to be further applied in the field of neuroscience, hard tissue biology, and analysis of small organic structures such as ear ossicles and zebra fish teeth.

An In-Process Measurement Technique for Non-contact Monitoring of Surface Roughness and form Accuracy of Ground Surfaces (연삭 가공면의 표면조도와 형상정밀도의 비접촉식 인프로세스 측정기술)

  • Yim, Dong-Yeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.4 no.2
    • /
    • pp.36-46
    • /
    • 1987
  • An optical technique using laser for non-contact measurement of surface roughness and form accuracy of ground surfaces is presented. It is found that, when a ground surface is illuminated by a beam of laser light, the roughness height and slope distribution has significant influence on the pattern of reflection and it maintains an unique Gaussian distribution relationship with the surface roughness. The principle idea of the optical measurement system is therefore monitor the radiation, and then calibrate it in process against surface roughness by means of necessary digital data processing. On the other hand, measuring the form accuracy of a ground surface is accomplished by using a triangular method, which is based on observing the movement of an image of a spot of light projected onto the surface. The image is focused, through a series of lenses for magnification, on a photodetector array lf line configur- ation. Then the relative movement of image and consequently the form accuracy of the surface can be obtained through appropriate calibration procedures. Experimental test showed that the optical roughness measurement technique suggested in this work is very efficient for most industrial applications being capable of monitoring the roughness heights ranging 0.1 to 0.6 .$\mu$m CLA values. And form accuracy can be measured in process with a resolution of 10 .$\mu$m.

  • PDF

Super Multi-view Display Method using Pin-hole Array (핀홀어레이를 이용한 슈퍼 멀티-뷰 3D 디스플레이)

  • Byeon, Jin-A;Kwon, Ki-Chul;Erdenebat, Munkh-Uchral;Park, Jae-Hyeung;Kim, Sung-Kyu;Kim, Jong-Jae;Kim, Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.1
    • /
    • pp.21-28
    • /
    • 2014
  • In this paper a Super Multi-view display method using a pinhole array with full parallax was proposed. The proposed method was simulated and its parameters analyzed. Also, the distribution and irradiance of light through each pinhole on the retina receiver, according to the change of crystalline lens focal length, were found by simulation. As a result, an image free of blurring was obtained while the crystalline lens focused on the depth plane of the three-dimensional image created by the imaging lens.

A Study of the Dependence on Incidence Angle of the Sensitivity of an Extraordinary Optical Transmission Sensor (특이 광 투과 센서에서 민감도의 입사각 의존성 연구)

  • Kwon, Yongjae;Lee, Seunghun;Kim, Taeyeon;Kim, Kyujung
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.3
    • /
    • pp.126-132
    • /
    • 2021
  • In this research, we have investigated the sensitivity of an extraordinary optical transmission sensor depending on the angle of incident light. Three types of light, including a collimated beam and focused beams (4× and 10×), were designed for the sensor system. To compare the sensitivity of the sensor, we measured transmittance spectra using deionized water (n=1.333) and refractive-index-matching oils (n=1.360 and 1.380). Those spectra were analyzed in terms of redshifting of the peak, so that we could determine the sensitivity. The sensitivity tended to increase when the collimated beam is used on the system, and we have concluded that the sensitivity could be affected by the incidence angle on an extraordinary optical transmission sensor.