• 제목/요약/키워드: Focused ion beam (FIB) technique

검색결과 25건 처리시간 0.024초

집속이온빔에 의한 미세가공 특성 (Micro-machining Characteristics using Focused Ion Beam)

  • 이종항;박철우;이상조
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.636-639
    • /
    • 2003
  • It is difficult to machine below 10 micrometers by conventional machining methods, such as micro-EDM. However, ultra micro machining using focused ion beam(FIB) is able to machine to 50 nanometers. In addition, 3 dimensional structures can be made by a combination of FIB and CVD to the level of 10 nanometers. Die & moulds techniques are better than one-to-one machining techniques in the mass production of ultra size structures, in regards to production costs. In this case, the machining precision of die & moulds affects produced parts. Also, it is advantageous to machine die & moulds to the 10 micrometer level by FIB technique rather than other techniques. In this paper, the grooving characteristics for die & mould materials by FIB were carried out experimentally in order to compare the machining characteristics of FIB with conventional machining methods. The results showed that the machining parameters and the scanning path of FIB affects the precision. The machined width and depth of the groove varied depending on the required depth due to the redeposition of the sputtered ion material accumulating on both the bottom and the side of the wall.

  • PDF

집속이온빔(Focused Ion Beam)에 의한 단결정 다이아몬드 공구의 마이크로/나노스케일 절삭공구 형상 제작 (Fabrication of Micro/nanoscale Cutting Tool Geometry of Single Crystal Diamond Tool by Focused Ion Beam)

  • 백승엽;장성민
    • 한국정밀공학회지
    • /
    • 제31권3호
    • /
    • pp.207-213
    • /
    • 2014
  • A study was carried out to fabricate the cutting tool geometry with micro/nanoscale on the single crystal diamond tool by using the FIB. The FIB technique is an ideal tool for TEM sample preparation that allows for the fabrication of electron-transparent foils. The FIB is appropriate techniques to sample and subsequently define the chemical composition and the structural state of mineral inclusion on the micro/nanoscale. The combination of FIB with a SEM allows for 3D information to be obtained from samples including 3D imaging. Cutting strategies were demonstrated to improve the performance of cutting tool geometry and to generate high aspect ratio micro cutting tool. A finely focused beam of 30keV Ga+ ions was used to mill cutting tool shapes for various micro patterns. Therefore FIB sputtering is used to shape a variety of cutting tools with dimensions in the $1-5{\mu}m$ range and cutting edge radii of curvature of under 50nm.

Cross-Sectional Transmission Electron Microscopy Specimen Preparation Technique by Backside Ar Ion Milling

  • Yoo, Jung Ho;Yang, Jun-Mo
    • Applied Microscopy
    • /
    • 제45권4호
    • /
    • pp.189-194
    • /
    • 2015
  • Backside Ar ion milling technique for the preparation of cross-sectional transmission electron microscopy (TEM) specimens, and backside-ion milling combined with focused ion beam (FIB) operation for electron holography were introduced in this paper. The backside Ar ion milling technique offers advantages in preparing cross-sectional specimens having thin, smooth and uniform surfaces with low surface damages. The back-side ion milling combined with the FIB technique could be used to observe the two-dimensional p-n junction profiles in semiconductors with the sample quality sufficient for an electron holography study. These techniques have useful applications for accurate TEM analysis of the microstructure of materials or electronic devices such as arrayed hole patterns, three-dimensional integrated circuits, and also relatively thick layers (> $1{\mu}m$).

투과전자현미경분석용 박편 제작 시 집속이온빔에 의한 광물 손상 (Damage of Minerals in the Preparation of Thin Slice Using Focused Ion Beam for Transmission Electron Microscopy)

  • 정기영
    • 한국광물학회지
    • /
    • 제28권4호
    • /
    • pp.293-297
    • /
    • 2015
  • 집속이온빔(FIB, focused ion beam)법은 광물 및 지질시료의 분석 대상 위치로부터 투과전자현미경(TEM, transmission electron microscope) 관찰을 위한 박편을 정밀하게 제작할 수 있는 방법으로 널리 보급되고 있다. 그러나 박편 제작과정에서 Ga 이온빔에 의한 구조 손상이나 인위적 효과들이 발생하여 전자빔에 의한 손상과 함께 TEM 분석에서의 난점들 중 하나이다. 광물 시료 FIB 박편의 TEM 관찰에서 석영과 장석의 비정질화, 커튼 효과, Ga 오염 등이 확인되었으며, 특히 입자 경계 부근이나 두께가 얇은 곳에서 이들 현상이 보다 뚜렷하다. 박편 제작 시의 가속전압 및 전류 조정 등의 분석절차 개선으로 이온빔 손상을 줄일 수 있으나, 어느 정도의 손상이나 오염은 피할 수 없으므로 TEM 박편 관찰과 해석에서 유의하여야 한다.

Preparation Method of Plan-View Transmission Electron Microscopy Specimen of the Cu Thin-Film Layer on Silicon Substrate Using the Focused Ion Beam with Gas-Assisted Etch

  • Kim, Ji-Soo;Nam, Sang-Yeol;Choi, Young-Hwan;Park, Ju-Cheol
    • Applied Microscopy
    • /
    • 제45권4호
    • /
    • pp.195-198
    • /
    • 2015
  • Gas-assisted etching (GAE) with focused ion beam (FIB) was applied to prepare plan-view specimens of Cu thin-layer on a silicon substrate for transmission electron microscopy (TEM). GAE using $XeF_2$ gas selectively etched the silicon substrate without volume loss of the Cu thin-layer. The plan-view specimen of the Cu thin film prepared by FIB milling with GAE was observed by scanning electron microscopy and $C_S$-corrected high-resolution TEM to estimate the size and microstructure of the TEM specimen. The GAE with FIB technique overcame various artifacts of conventional FIB milling technique such as bending, shrinking and non-uniform thickness of the TEM specimens. The Cu thin film was uniform in thickness and relatively larger in size despite of the thickness of <200 nm.

집속 이온빔에 의한 3차원 가공 시스템 (3 Dimensional Machining System using Focused ion Beam)

  • 박철우;이종항
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.490-493
    • /
    • 2004
  • There is great difficulty in machine below 10 micrometers by conventional machining methods, such as micro-EDM. However, ultra micro machining using focused ion beam(FIB) is able to machine to 50 nanometers. Bie & moulds techniques are better than one-to-one machining techniques in regards to production costs in the mass production of ultra size structures. Also, it is advantageous to machine die & moulds to the 10 micrometers level by FIB technique rather than other techniques. It is difficult to machine the three dimensional machining, such as micro lens, using FIB system because of their machining characteristics. In this paper, three dimensional machining techniques were properly introduced, and also experiments showed effectiveness of their techniques.

  • PDF

Focused Ion Beam-Based Specimen Preparation for Atom Probe Tomography

  • Lee, Ji Yeong;Ahn, Jae-Pyoung
    • Applied Microscopy
    • /
    • 제46권1호
    • /
    • pp.14-19
    • /
    • 2016
  • Currently, focused ion beams (FIB) are widely used for specimen preparation in atom probe tomography (APT), which is a three-dimensional and atomic-scale compositional analysis tool. Specimen preparation, in which a specific region of interest is identified and a sharp needle shape created, is the first step towards successful APT analysis. The FIB technique is a powerful tool for site-specific specimen preparation because it provides a lift-out technique and a controllable manipulation function. In this paper, we demonstrate a general procedure containing the crucial points of FIB-based specimen preparation. We introduce aluminum holders with moveable pin and an axial rotation manipulator for specimen handling, which are useful for flipping and rotating the specimen to present the backside and the perpendicular direction. We also describe specimen preparation methods for nanowires and nanopowders, using a pick-up method and an embedding method by epoxy resin, respectively.

집속 이온빔 가공변수에 따른 Au 에칭 특성 연구 (The ocused Ion Beam Etching Characteristic of Au)

  • 박진주;김성동
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.129-133
    • /
    • 2007
  • Focused Ion Beam(FIB) systems is a useful tool for the fabrication of micro-nano scale structures. In this study, the effects of FIB etching on the Au microstructure are systematically investigated. As the fabrication parameters, ion dose, dwell time and beam overlap ratio are studied. First, the increases of Ga ion dose makes the milling yield higher and the sidewall of milling profile steeper. Dwell time is found to have little effects on the milling profile due to the relatively large milling area of $1\times1{\mu}m^2$ used in this study. However, beam overlap significantly affects not only milling rate but also milling profile. As the beam overlap ratio changes from positive to negative, the development of regular cross-stripe patterns at the bottom with low milling rate is observed.

Transmission Electron Microscope Specimen Preparation of Si-Based Anode Materials for Li-Ion Battery by Using Focused Ion Beam and Ultramicrotome

  • Chae, Jeong Eun;Yang, Jun Mo;Kim, Sung Soo;Park, Ju Cheol
    • Applied Microscopy
    • /
    • 제48권2호
    • /
    • pp.49-53
    • /
    • 2018
  • A successful transmission electron microscope (TEM) analysis is closely related to the preparation of the TEM specimen and should be followed by the suitable TEM specimen preparation depending on the purpose of analysis and the subject materials. In the case of the Si-based anode material, lithium atoms of formed Li silicide were removed due to ion beam and electron beam during TEM specimen preparation and TEM observation. To overcome the problem, we proposed a new technique to make a TEM specimen without the ion beam damage. In this study, two types of test specimens from the Si-based anode material of Li-ion battery were prepared by respectively adopting the only focused ion beam (FIB) method and the new FIB-ultramicrotome method. TEM analyses of two samples were conducted to compare the Ga ion damage of the test specimen.

Cross-sectional TEM Specimens Priparation of Precisely Selected Regions of Semiconductor Devices using Focused Ion Beam Milling

  • 김정태;김호정;조윤성;최수한
    • 한국재료학회지
    • /
    • 제3권2호
    • /
    • pp.193-196
    • /
    • 1993
  • A procedure for preparing cross-sectional specimens for transmission electron microscopy(TEM)by focused ion beam(FIB)milling of specific regions of semiconductor devices is outlined. This technique enables TEM specimens to be pripared at precisely preselected area. In-situ #W thin film deposition on the top surface of desired site is complementally used to secure the TEM specimens to be less wedge shaped, which is main shortcoming of previous FIB-assisted TEM sample preparation technique. This technique is quite useful for the TEM sample priparation for fault finding and the characterization of fabrication process associated with submicron contact technologies.

  • PDF