• Title/Summary/Keyword: Focused Ultrasound

Search Result 146, Processing Time 0.025 seconds

Signal-to-noise Ratio in Time- and Frequency-domain Photoacoustic Measurements by Different Frequency Filtering (주파수 필터링 함수에 따른 시간 및 주파수 영역 광음향 측정에 대한 신호 대 잡음비 분석)

  • Kang, DongYel
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.2
    • /
    • pp.48-58
    • /
    • 2019
  • We investigate the signal-to-noise ratios (SNRs) of time-domain (i.e. pulsed illumination) and frequency-domain (i.e. chirped illumination) photoacoustic signals measured by a spherically focused ultrasound transducer for spherical absorbers. The simulation results show that the time-domain photoacoustic SNR is higher than that of frequency-domain photoacoustic signals, as reported in the previous literature. We understand the reason for this SNR gap between the two measurement modes by analyzing photoacoustic-signal spectra, considering the incident beam energy controlled by the maximum permissible exposure. As the result of this approach, we find that filtering off the DC term in the chirped signal's spectrum improves frequency-domain photoacoustic SNRs by up to approximately 5 dB. In particular, it is observed that photoacoustic SNRs are highly sensitive to an upper-frequency value of frequency filtering functions, and the optimal upper-frequency values maximizing the SNR are different in time- and frequency-domain photoacoustic measurements.

A Trend Analysis of Radiological Research in Korea using Topic Modeling (토픽모델링을 이용한 국내 방사선 학술연구 트렌드 분석)

  • Hong, Dong-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.343-349
    • /
    • 2022
  • We intend to use topic modeling to identify radiation-themed papers published from 1989 to 2022 and analyze the relevance and weight between topics. This study analyzed topics derived from national subjects for 717 papers published until recently in 2022 to contribute to the revitalization of research in the field of radiation. Through text mining, overall research trends on the subject distribution of the study were analyzed, and five topics were derived through topic modeling. First, among the papers to be analyzed, a total of 1,675 words were frequency-analyzed through the preprocessing process of key words in a total of 717 papers centered on keywords. Second, as a result of analyzing topics based on the association of constituent words for five topics, it was found that studies focused on minimizing dose in the range that does not degrade image quality in the fields of radiation, image, CT clinical. In addition, it was found that various studies were mainly conducted in the MRI, and the study of ultrasound in various areas of disease analysis was actively attempted.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Response Properties of Meridians for focused variable electromagnetic stimulus (접속형 가변 전자계 자극에 대한 경락반응특성)

  • Lee, Gyoun-Jung;Cho, Dong-Guk;Kim, Soo-Byung;Kwon, Sun-Min;Shin, Tae-Min;Lee, Kyoung-Joung;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1399-1410
    • /
    • 2009
  • It is a method to treat pain using medication, neurotomy, and surgery. And acupuncture, ultrasound, electric treatment, and magnetic treatment are applied as a alternative physiotherapy. Electronic therapy is useful but it can be affected by impedance of skin or subcutaneous tissue. So, percutaneous stimulation is leading therapy, that is very randomly. We developed the system which can stimulate parts of acupuncture point noninvasively using the focused magnetic field. And we designed the magnetic stimulation electrode which is considered efficiency of the magnetic stimulation. It can make similar stimulation with manual acupuncture. To confirm the availability and reliability we compared Meridian Electronic Potential(MEP) change between manual acupuncture and magnetic stimulation. From this result, we found out the MEP changes of manual acupuncture and magnetic stimulation were similar. And there were various response properties as changes of stimulation method, intensity, and frequency. Also, the MEP change can be induced by electromagnetic stimulation. We confirmed that it is possible to use electromagnetic stimulation as a acupoint stimulation or pain treatment instrument.

Research and consideration on the evaluation of usability formation of focused ultrasonic stimulation systems (집속형 초음파 자극 시스템의 사용적합성 형성평가에 대한 연구 및 고찰)

  • Kim, Jun-tae;Kim, Ju-hee;Joo, Kyu-tai;Kim, Kyung-ah;Ryu, Ok-su;Jo, Jae-hyun;Jeong, Jin-Hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.164-177
    • /
    • 2022
  • Medical device usability evaluation refers to the evaluation of medical devices through actual users before the final prototype production is completed. IEC 62366, one of the international safety standards for electronic medical devices, is a standard that must be applied to obtain medical device licenses in major advanced countries such as Europe and the United States. In Korea, through the Ministry of Food and Drug Safety's notice, from January 2021, sequential application by grade has been implemented. In this study, 15 participant specialists were recruited through the Incheon G University Hospital Medical Device Convergence Center for formative evaluation during user suitability evaluation of the focused ultrasound stimulation system being developed by Icleo Co., Ltd., and the test was conducted through joint scenario development. . In the result of task performance, the performance rate was 90.67%, and after the completion of the performance, 86.67% of 'Easy user interface' and 94% of 'Identification/Readability/Understanding of information' questions in the participant survey results analysis by question. The response rate was above average.

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.

Clinical Outcome of Treatment for Stage IIA, IIB and III Osteosarcomas (Comparative Studies between Invasive Surgical Treatment and Non-invasive HIFU Technique) (진행된 장관골 골육종의 수술 및 비수술적 강력 집속 초음파 치료의 장기 추적 결과)

  • Wenzhi, Chen;Wei, Wang;Zhibiao, Wang;Hui, Zhu;Kequan, Li;Hao, Piao Xiang;Haibing, Su;Chengbing, Jin;Feng, Wu;Jin, Bai;Rhee, Seung-Koo;Kang, Yong-Koo;Bahk, Won-Jong;Chung, Yang-Guk;Huh, Sung-Woo;Lee, Eun-Sang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.1
    • /
    • pp.37-46
    • /
    • 2006
  • Purpose: To evaluate the end results between the surgical treatment with neo-adjuvant chemotherapy in Korea and non-invasive high intensity focused ultrasound (HIFU) technique in China for osteogenic sarcomas. Materials and Methods: The surgical treatment with neoadjuvant chemotherapy for total 67 cases (4 IIA, 58 IIB, and 5 III) in Korea since 1993 and the HIFU therapy for total 71 cases (57 II and 14 III) in China since 1997 was performed. In Korea, neo-adjuvant chemotherapy in 66 cases out of total 67 patients, but the adjuvant chemotherapy in only one case was done. On the contrary, in China, full chemotherapy for more than 9 times for 37 patients with stage II out of total 71 cases, but for less than 8 times of partial chemotherapy for 23 patients (stage II) and 14 patients (stage III) was done. The surgical treatment in total 67 Korean patients was done with wide resection and reconstruction for 56 patients, but wide resection without reconstruction for 5 patients and amputation for 6 patients. In china, total 71 patients was treated with average 1.5 times (1~4 times) of HIFU, and if there are some evidences of residual tumor after HIFU with following MRI, the second HIFU therapy was given 2~4 weeks later. After then, the bony defect was in no touch, keep bracing for long time expecting regeneration. All of them were followed for average 46 Mo (12~150 Mo) in Korea, but followed for average 22 Mo (9 years~8 months) in China. Results: The 5 year survival rate (stage II), was average 92.7% (IIA 100%, IIB 85.5%) in Korea series, and average 78.7% (full chemotherapy 91.8%, part chemotherapy 56.6%) in China series. The 3 year survival rate (stage III) was 20% in Korea and 7.1% in China. So, the final overall survival rate was 65.2% in Korea and 51.8% in China. The overall functional outcome score by ISOLS was 24.3 (81%) in Korea and 19.8 (73%) in China. There are 25.4% (17/67 cases) of complications in Korea and 31% (27 complications in 22 patients out of total 71 cases) in China after each treatment. Conclusions: The end results of Korea series which was treated with neoadjuvant chemo- and surgical methods are better than that of non-invasive thermal ablation in china. But we also believe the HIFU, as one of, was also effective to decrease the local recurrence and symptomatic releaf for stage II or even in III of osteogenic sarcomas.

  • PDF

Dynamic Contrast-Enhanced MR Imaging in Detecting Local Tumor Progression after HIFU Ablation of Localized Prostate Cancer (국소적 전립선암의 고강도 집속 초음파 치료 후 국소적 암 재발의 발견과 역동적 조영증강 자기공명영상의 역할)

  • Park, Jung Jae;Kim, Chan Kyo;Lee, Hyun Moo;Park, Byung Kwan;Park, Sung Yoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.192-199
    • /
    • 2013
  • Purpose : To retrospectively evaluate the diagnostic performance of dynamic contrast-enhanced MR imaging (DCE-MRI) in detecting recurrent prostate cancer after HIFU of clinically localized cancer, as compared with T2-weighted imaging (T2WI). Materials and Methods: Twenty-six patients with increased prostate-specific antigen levels after HIFU were included in this study. All MR examinations were performed using T2WI and DCE-MRI, followed by transrectal ultrasound-guided biopsy. MRI and biopsy results were correlated in six prostate sectors. Residual or recurrent cancer after HIFU was defined as local tumor progression if biopsy results showed any cancer foci. Two independent readers interpreted the MR images. Results: Of 156 prostate sectors, 51 (33%) were positive for cancer in 17 patients. For detecting local tumor progression, the sensitivity of DCE-MRI and T2WI was 80% and 57% for reader 1 (P < 0.001) versus 84% and 61% for reader 2 (P < 0.001), respectively. The specificity and overall accuracy between DCE-MRI and T2WI showed no statistical difference in both readers (P > 0.05). Interobserver agreement of DCE-MRI and T2WI was moderate and fair, respectively. Conclusion: For detecting local tumor progression of prostate cancer after HIFU, DCE-MRI was more sensitive than T2WI, with less interobserver variability.

Growth, Behavior, and Carcass Traits of Fattening Hanwoo (Korean Native Cattle) Steers Managed in Different Group Sizes

  • Lia, S.G.;Yang, Y.X.;Rhee, Y.J.;Jang, W.J.;Ha, J.J.;Lee, S.K.;Song, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.7
    • /
    • pp.952-959
    • /
    • 2010
  • This study was conducted to evaluate growth, behavior and carcass traits of fattening Hanwoo (Korean native cattle) steers managed in different group sizes. A total of 48 animals, 6 months of age, were allocated to one of three group sizes and the experiment was conducted from 12 to 30 months of age. Groups were balanced for weight and the group sizes consisted of 4, 8, or 12 steers which were named 4sG, 8sG and 12sG, respectively. When animals were 12 months of age, initial fasted body weight (BW, $304.51{\pm}12.40\;kg$) was measured. All animals were housed at a constant space allowance of $8.82\;m^2$ per animal, and a feeder and drinker were provided per 4 animals. The whole fattening stage was divided into three phases: phase I (from 12 to 18 month of age), phase II (from 19 to 24 month of age), and phase III (from 25 to 30 month of age). Steers managed in 12sG showed low (p<0.05) growth rate and feed conversion rate (FCR) in phase I and phase II when compared to other treatment groups. However, this difference was not observed for the whole fattening phase (p>0.05). Steers managed in 4sG had a thick (p<0.05) ultrasound back fat thickness at 15 and 18 months of age. However, group size had no effect on meat yield and quality traits of area and marbling score. Animals managed in 8sG yielded a better meat grade of "A" than the "B" grade in other treatment group sizes. Lean color, fat color, firmness and maturity scores did not differ among group sizes. Hanwoo steers housed under 12sG spent less time on eating concentrate, relevant higher eating rate, less frequency of allogrooming, and more time on walking (p<0.05). It could be concluded that a large group size retarded growth rate and back fat thickness in the fattening stage, which was mainly focused on 15 and 18 months of age.

Cavitation suppression through the modification of spectral characteristics in the field of high intensity focused ultrasound (주파수 특성 변환을 통한 고강도 집속형 초음파 공동 현상의 억제)

  • 최민주
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.449-454
    • /
    • 1998
  • 전립선 비대증 및 각종 고형암 조직을 제거하기 위해 이용되는 고강도 집속형 초음파 시스템은 초음파의 조직에 대한 열 효과를 이용한다. 이 경우 수MPa의 고 압력 초음파를 사용하기 때문에 수술시 초음파에 의한 조직내의 공동 현상이 수반되고 이로 인해 초음파의 집속 효과가 감소하게 된다. 본 논문에서는 초음파 공동 현상을 억제하기 위하여 초음파의 주파수 특성을 고려하였다. 초음파의 크기는 일정하게 유지하면서 증가하는 주파수로 변조된 초음파와 비선형 고저파 (nonlinear harmonics) 성분을 포함한 왜곡된 초음파에 대한 기포의 반응을 Gilmore 기포 모델을 이용하여 관찰하였다. 초음파의 주파수 변조는 10 $\mu\textrm{s}$ 동안 초기 주파수 1 MHz부터 시작하여 7 MHz까지 선형적으로 증가하도록 하였다. 파형을 왜곡시키는 고저파 성분의 크기는 주파수에 역 비례 하도록 하였다. 초음파의 기본 주파수는 1 MHz로 하였고, 압력은 0.1 MPa과 1 MPa의 두 경우를 고려하였다. 초기 기포의 반경은 1 $\mu\textrm{m}$으로 하였고, 기포 주위의 유체는 물로 가정하였다. 시뮬레이션 결과로부터, 주파수를 변조시키거나 파형을 왜곡시킨 초음파에 대한 기포의 진동은, 동일한 압력의 정현파에 대한 경우 보다 작은 것으로 나타났다. 주파수 변조된 초음파에 반응한 기포의 진동은 압력이 낮을 때 (0.1 MPa), 변조된 주파수가 기포의 공진 주파수인 3 MHz 부근에서 최대치를 보이다가 이후 급격히 감소하는 경향을 보였다. 반면, 압력이 높아지면 (1 MPa) 기포의 진동은 주파수의 증가와 함께 감소하다가 3 MHz 이상으로 변조 될 경우, 유의한 변화를 보이지 않는 것으로 나타났다. 이 결과는 초음파의 적절한 주파수 성분 조절로 초음파 공동 현상을 일정 수준 억제할 수 있음을 시사한다. 고려가 수반되어야 할 것으로 보인다. 다음 내용을 정리해 보고자 한다.리해 보고자 한다.rc$ 구입할 때 중점적으로 살펴보는 사항은 신선도와 순수재래종 여부, 위생상태였다. 한편 소비자가 언제나 구입할 수 없다는 의견이 85.2%나 되어 원활한 공급과 시장조성이 아직 정착되지 않고 있었다. $\bigcirc$ 현재 유통되고 있는 재래종닭은 소비자 대부분이 잡종으로 인식하고 있었으며, 재래종과 일반육계와의 구별은 깃털색, 피부색, 정강이색등 외관상으로 구별하고 있었다. 체중에 대한 반응은 너무 작다는 의견이었고, 식품으로의 인식도는 비교적 고급식품으로 인식하고 있다. $\bigcirc$ 재래종닭고기의 브랜드화에 대한 견해는 젊고 소득이 높은 계층에서 브랜드화의 필요성을 강조하고 있다. $\bigcirc$ 재래종달걀의 소비형태는 대부분의 소비자가 좋아하였으나 아직 먹어보지 못한 응답자가 많았다. 재래종달걀의 맛에 대해서는 고소하고 독특하여 차별성을 느끼고 있었다. $\bigcirc$ 재래종달걀의 구입장소는 계란판매점(축협.농협), 슈퍼, 백화점, 재래닭 사육 농장등 다양하였으며 포장단위는 10개를 가장 선호하였고, 포장재료는 종이, 플라스틱, 짚의 순으로 좋아하였다. $\bigcirc$ 달걀의 가격은 200원정도를 적정하다고 하였으며, 크기는 (평균 52g)는 가장 적당하다고 인식하고 있으며, 난각색은 대부분의 응답자가 갈색을 선호하였다. $\bigcirc$ 재래종달걀의 구입시 애로사항은 믿을수 없고, 구입장소를 몰라서, 값이 싸다 등이었고, 앞으로 신뢰할 수 있고 위생적인 생산 및 유통체계가 확립될 경우 더 많이 소비하겠다는 의견이었다. $\bigcirc$ 재래닭 판매업소(식당)의 판매형태는 66.7%인 대부분

  • PDF