• Title/Summary/Keyword: Focal length

Search Result 373, Processing Time 0.022 seconds

Focal Muscle Vibration Changes the Architecture of the Medial Gastrocnemius Muscle in Persons With Limited Ankle Dorsiflexion

  • Moon, Il-Young;Lim, Jin-Seok;Park, Il-Woo;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.48-53
    • /
    • 2022
  • Background: The gastrocnemius tightness can easily occur. Gastrocnemius tightness results in gait disturbance. Thus, various interventions have been used to release a tight gastrocnemius muscle and improve gait performance. Moreover, focal muscle vibration (FMV) has recently been extensively researched in terms of tight muscle release and muscle performance. However, no study has investigated the effects of FMV application on medial gastrocnemius architectural changes. Objects: In this study, we aimed to investigate the effects of FMV on medial gastrocnemius architecture in persons with limited ankle dorsiflexion. Methods: Thirty one persons with <10° of passive ankle dorsiflexion participated in this study. We excluded persons with acute ankle injury within six months prior to study onset, a history of ankle fracture, leg length discrepancy greater than 2 cm, no history of neurological dysfunction, or trauma affecting the lower limb. The specifications of the FMV motor were as follows: a fixed frequency (fast wave: 150 Hz) and low amplitude (0.3-0.5 mm peak to peak) of vibration; the motor was used to release the medial gastrocnemius for 15 minutes. Each participant completed three trials for 10 days; a 30-second rest period was provided between each trial. Medial gastrocnemius architectural parameters [muscle thickness (MT), fiber bundle length (FBL), and pennation angle (PA)] were measured via ultrasonography. Results: MT significantly decreased after FMV application (p < 0.05). FBL significantly increased from its baseline value after FMV application (p < 0.05). PA significantly decreased from its baseline value after FMV application (p < 0.05). Conclusion: FMV application may be advantageous in reducing medial gastrocnemius excitability following a decrease in the amount of contractile tissue. Furthermore, FMV application can be used as a stretching method to alter medial gastrocnemius architecture.

Optical design of three-mirror telescope system for infra-red and visible imaging (적외선 및 가시광선 결상용 3반사망원경계의 설계)

  • 이종웅;홍경희;권우근
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.183-190
    • /
    • 1996
  • To design three-mirror telescope system (F/8, 120 inch in focal length) for visible and infra-red band imaging, methods for power configuring and correction of the third order aberrations were studied. In the design of the telescope system, a three-mirror system corrected for spherical aberration, coma, and astigmatism was used for infra-red imaging, and the aberrations were corrected by using conic surfaces. For visible imaging, a singlet corrector lens was appended at the front of the focal plane to correct filed curvature. The telescope system has diffraction limited performance for 10 ${\mu}{\textrm}{m}$ in wavelength within 2.4$^{\circ}$ of field-of-view. In the visible band imaging, the rms spot size of the telescope system is less than 25 ${\mu}{\textrm}{m}$ within 3$^{\circ}$ of field-of-view for monochromatic light, and the telescope system satisfies flat field condition for CCD application.

  • PDF

Fabrication and characteristics of multilevel acoustic Fresnel lens for ultrasonic transducer for diagnostic imaging (영상진단용 초음파 트랜스듀서를 위한 멀티레벨 음향 프레넬 렌즈의 제작 및 특성)

  • Kim, Dong-Hyun;Ha, Kang-Lyeol;Kim, Moo-Joon;Kim, Jung-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.33-41
    • /
    • 2009
  • A multilevel acoustic Fresnel lens (MAFL) for the ultrasonic imaging transducer of which center frequency is approximately 5.MHz was newly designed and fabricated. The phase level of the lens was 64, and the focal length and the aperture width were 30.mm and 11.mm, respectively. The characteristics of impulse response, acoustic field and imaging performance of the transducer attached the lens were compared with the transducer attached a conventional refraction type acoustic lens (RAL). The results show that the center frequency, the loop sensitivity, and the focal depth of the MAFL transducer were higher or larger than those of the RAL transducer by approximately 0.2.MHz, 1.4.dB, and 2.mm, respectively. Consequently, it was shown that the brighter acoustic images with higher lateral resolution and the increased imaging performance for deep targets can be obtained by using the MAFL transducer.

광학렌즈 기술.시장 동향

  • 한국광학기기협회
    • The Optical Journal
    • /
    • s.154
    • /
    • pp.33-45
    • /
    • 2014
  • ■ 광통신용 렌즈는 광통신 시스템에 있어서 송신단과 수신단에 사용되는 하나의 부품으로 집광/발산의 결상 기능을 지니며, 광회로 부품과 광섬유 또는 수발광소자인 LD/PD와 광섬유를 효율 좋게 저손실로 접속하는 기능을 수행함. ■ 마이크로 렌즈는 마이크로 광학의 분야에 있어 광의 집광 및 평행 광으로의 변환에 빠질 수 없는 가장 기본적인 소자로서, 마이크로 렌즈의 종류로는 마이크로 볼 렌즈, 비구면 렌즈와 GRIN 렌즈가 대표적으로 있음. ■ 렌즈에 적용되는 사양으로서 렌즈의 유효 구경, 초점(focal point), 주점(principle point), 주점에서 초점까지의 거리인 초점 거리(focal length), 가상의 법선을 기준으로 빛이 입사되는 각도인 입사각, 빛이 다른 매질을 만나 반사되는 각도인 반사각, 서로 다른 매질을 빛이 통과할 때 굴절하는 굴절각 등이 있음. ■ 렌즈 모듈의 구조는 렌즈, 스페이서(spacer), 아리리스(Iris), 백링(back-ring), 바렐(Barrel)로 구성함. ■ LD 모듈에서 광원에 패브리 페로(FP)로 사용하는 것에는 볼 렌즈가, DFB 광원으로 사용하는 것으로는 비구면 렌즈가 사용하고 있음. 이를 위해 PON용에서는 G-PON의 OLT, ONU 측, GE-PON의 OLT측에는 비구면 렌즈가 사용되나 GE-PON의 ONU측에는 볼 렌즈가 주로 사용되고 있음. ■ 2012년 볼 렌즈 시장은 수량 기반으로 2011년 대비 9.7% 증가한 7,350만 개, 금액기반으로는 17.0% 증가한 3,125만$를 기록하였음. ■ 2012년 비구면 렌즈 시장은 수량 기반으로 2011년 대비 22.0% 증가한 2,220만 개, 금액 기반으로는 32.0% 증가한 8,900만$를 기록하였음. ■ 2012년 광통신용 렌즈 시장(볼 + 비구면)은 수량 기반으로 2011년 대비 12.3% 증가한 9,570만 개, 금액 기반으로는 27.7% 증가한 1억 2,063만$이었음.

  • PDF

Fabrication and Characterization of Polymer Microlens using Solvent-vapor-assisted Reflow (솔벤트 증기처리 Reflow를 이용한 폴리머 마이크로 렌즈 제작 및 특성고찰)

  • Yang, Seung Woo;Kim, Sin Hyeong;Kim, Bo Hyun;Cho, Young Hak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.3
    • /
    • pp.299-305
    • /
    • 2015
  • In this paper, we propose a simple and low-cost fabrication method of polymer microlens using solvent-vapor-assisted reflow (SVAR). Metal molds for replication of polymer were fabricated using micro milling and the cylindrical shape of polymer was imprinted using hot-embossing process. The cylindrical shape of polymer was changed to hemispherical lens shape by SVAR. The characteristics of fabricated microlens were evaluated according to the condition of SVAR such as temperature and time. The focal length of polymer microlens could be controlled more easily in low-temperature and long-time condition than in high-temperature and short-time condition. That is, the level of concentrated light to focal point could be improved through the control of temperature and time. Also, we confirmed that toluene was more appropriate solvent than acetone in fabrication of PMMA polymer microlens using SVAR.

The Fabrication of Microlenses by Photoresist Melting Method (Photoresist 용융법을 이용한 미세렌즈 행렬 제작)

  • 주영구;송현우;이용희;송석호
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.298-303
    • /
    • 1994
  • Microlens arrays are fabricated by melting "islands" of thick photoresist on a glass substrate. Microlenses with diameters $25\mu\textrm{m}$, $50\mu\textrm{m}$, $100\mu\textrm{m}$are made. Their surface profiles are obtained by a scanning electron microscope and a mechanical surface profilometer. The wavefront of the microlenses is measured by phase-shifting techniques using a Mach-Zehnder-like configuration. Thereby wavefront errors, focal lengths. point spread functions are obtained. The microlens with the diameter of $100\mu\textrm{m}$ has focal length of $164\mu\textrm{m}$ and spot diameter is less than $5\mu\textrm{m}$..

  • PDF

A Concept of Adaptive Focusing using a Rotman Lens for Detecting Buried Structures

  • Kim, Jae-Heung
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.536-540
    • /
    • 2003
  • A new concept of adaptive focusing, using a Rotman lens, is presented in this paper. A Rotman lens is a microwave lens which is able to focus microwave power on its focal arc or generate multiple beams. By adding the array of phase shifters between a Rotman lens and antenna elements, the wavefront can be adaptively modulated to focus objects distributed in short range rather than far-field zone. From the optical point of view, the propagations of the lens have been simplified from the Fresnel diffraction integral to the Fourier transform. Using Fourier Transform, a beam propagation method has been developed to show improvement of the resolution by controlling wavefront of wave propagating from an aperture-type antenna array. The beam width(or spot size) and intensity have been calculated for a focused beam propagating from an array having $10{\lambda}$ of its size. For the beam with $20{\lambda},\;30{\lambda}$, and $50{\lambda}$ of geometrical focal length, the half-power beamwidth (spot size) is about $1.1{\lambda},\;1.3{\lambda}$, and $1.9{\lambda}$, respectively.

  • PDF

An active stereo camera modeling (동적 스테레오 카메라 모델링)

  • Do, Kyoung-Mihn;Lee, Kwae-Hi
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.3
    • /
    • pp.297-304
    • /
    • 1997
  • In stereo vision, camera modeling is very important because the accuracy of the three dimensional locations depends considerably on it. In the existing stereo camera models, two camera planes are located in the same plane or on the optical axis. These camera models cannot be used in the active vision system where it is necessary to obtain two stereo images simultaneously. In this paper, we propose four kinds of stereo camera models for active stereo vision system where focal lengths of the two cameras are different and each camera is able to rotate independently. A single closed form solution is obtained for all models. The influence of the stereo camera model to the field of view, occlusion, and search area used for matching is shown in this paper. And errors due to inaccurate focal length are analyzed and simulation results are shown. It is expected that the three dimensional locations of objects are determined in real time by applying proposed stereo camera models to the active stereo vision system, such as a mobile robot.

  • PDF

Polarization-Dependent Microlens Array Using Reactive Mesogen Aligned by Top-Down Nanogrooves for Switchable Three-Dimensional Applications

  • Son, Ki-Beom;Kim, Mugeon;Park, Min-Kyu;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.265-271
    • /
    • 2015
  • We propose a reactive mesogen (RM) lens array to obtain good focusing behavior along with a short focal plane, where the focusing behavior is switchable according to the polarization state of incident light. Polarization-dependent focusing behavior is obtained using a planoconvex RM microlens array on a planoconcave isotropic lens template. Even though the sagitta of our RM lens is high, to obtain the short focal length, the RM layer can be aligned well by introducing a top-down alignment effect, using a nanogrooved template. The optical noise due to the $moir{\acute{e}}$ effect generated by the nanogrooves on the surface of the planoconvex RM layer can be removed simply by overcoating a thin RM layer, which is self-aligned by the geometric surface effect, without an additional alignment process. We demonstrate a hexagonal-packed RM lens array that has a very high fill factor and symmetric phase profile, for an ideal lens.

Optical Design of an Off-axis Five-mirror-anastigmatic Telescope for Near Infrared Remote Sensing

  • Li, Xing Long;Xu, Min;Pei, Yun Tian
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.343-348
    • /
    • 2012
  • This paper described an off-axis five-mirror-anastigmatic telescope. It is composed of three aspheric surfaces and one spherical surface while the third mirror and fifth mirror have the same parameters at the same place. This configuration is useful for having wide field of view. The strip full field of view for the near infrared telescope is $20^{\circ}{\times}0.2^{\circ}$. The entrance pupil is located in front of the first mirror. There is an intermediate image between the second mirror and the third mirror. The entrance pupil diameter is 100 mm and the effective focal length is 250 mm. The spectral range is $0.85-1.75{\mu}m$. The pixel pitch is $15{\mu}m$. The image quality is near the diffraction limit. Some methods were used to restrain the stray light such as a field stop near the intermediate image, the baffle, the narrow-band pass filter and a stop in front of the focal plane.