• Title/Summary/Keyword: Focal distances

Search Result 25, Processing Time 0.034 seconds

A Simple Method for Determining Focal Distances Using Talbot Self-Images

  • Spires, Oliver;Sasian, Jose;Lee, Sukmock
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.638-642
    • /
    • 2015
  • We present a simple method to determine the focal distances of lenses with the Talbot self-images. This method uses only one grating, and a priori knowledge of the period of the grating is replaced with a linear relation between the (de)magnified periods of the Talbot images and the lens-to-grating distance. A thick lens whose effective focal length is 500 mm was used to validate the method, and the focal distance of the converging beam was determined with the difference of 0.15% for the nominal focal distance of 521.9 mm. The determined period of the grating with the difference of 0.2% also supports the validation.

A Study on the Focal Mechanism of the Hongsung Earthquake from the P-Wave Polarity Distributions (초동극성분포를 이용한 홍성지진의 Focal Mechanism 연구)

  • 김준경
    • The Journal of Engineering Geology
    • /
    • v.1 no.1
    • /
    • pp.121-136
    • /
    • 1991
  • The focal mechanism of the Hongsung Earthquake (1978. Oct. 7, M$_L$=5.0, Latitude 36.62N, Longitude 1 26.67E) was evaulated using the polarity distribution of the P-Waveforms. Through the non-linear computer process, the compatibility of polarity distributions of the 9 P-Waveforms observed at teleseismic distances from the Hongsung Earthquake epicenter was investigated to those of the focal mechanism determined from the varying strike, dip and rake angles. The resultant values for the strike and dip angle of the principal fault plane, which apparently matches very well the sunface lineament of the Hongsung region, are determined to be about 247 degree and 78 degree with uncertainties, respectively. However, the rake angle of the focal mechanism has wide range of 40 degree to 160 degree, which is mainly due to the poor coverage of the azimuthal angle of the observed seismic stations. Due to the consistency of principal stress axes, the resultant focal mechanism could support the current stress regime of that region, which may be caused by subduction of the Pacific Plate under the Eurasia Plate along the Japan Trench. It also provides information of seismic source characteristics of the part of the Korean Peninsula for aseismic design criteria such as Site Specific Response Spectrum and Strong Ground Motion Time History for the nuclear power plants and related nuclear waste disposal facility sites.

  • PDF

Validation Experiments for the Determination of Particle Focal Positions in Digital Particle Holography (디지털 입자 홀로그래피의 입자 초점면 결정에 관한 실험적 검증)

  • Yang, Yan;Kang, Bo-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.10
    • /
    • pp.784-790
    • /
    • 2008
  • The feasibility and the accuracy of the correlation coefficient(CC) method for the determination of particle positions along the optical axis in digital particle holography were verified by alidation experiments. A traverse system with capable of high precision was used to move the particle objects by exact known distances between several different positions. The particle positions along the optical axis were calculated by the CC method and compared with their exact values to obtain the errors of the focal plane determination. The tested particles were 2D dots in a calibration target along with different sized glass beads and droplets that reflected and caused a three-dimensional effect. The results show that the CC method can work well for both the 2D dots and the 3D particles. The effect of other particles on the focal plane determination was also investigated. The CC method can locate the focal plane of particles with a high precision, regardless of the existence of other particles.

Virtual portraits from rotating selfies

  • Yongsik Lee;Jinhyuk Jang;SeungjoonYang
    • ETRI Journal
    • /
    • v.45 no.2
    • /
    • pp.291-303
    • /
    • 2023
  • Selfies are a popular form of photography. However, due to physical constraints, the compositions of selfies are limited. We present algorithms for creating virtual portraits with interesting compositions from a set of selfies. The selfies are taken at the same location while the user spins around. The scene is analyzed using multiple selfies to determine the locations of the camera, subject, and background. Then, a view from a virtual camera is synthesized. We present two use cases. After rearranging the distances between the camera, subject, and background, we render a virtual view from a camera with a longer focal length. Following that, changes in perspective and lens characteristics caused by new compositions and focal lengths are simulated. Second, a virtual panoramic view with a larger field of view is rendered, with the user's image placed in a preferred location. In our experiments, virtual portraits with a wide range of focal lengths were obtained using a device equipped with a lens that has only one focal length. The rendered portraits included compositions that would be photographed with actual lenses. Our proposed algorithms can provide new use cases in which selfie compositions are not limited by a camera's focal length or distance from the camera.

Fabrication of holographic zone plate using dichromated gelatin hologram (Dichromated Gelatin 박막을 이용한 홀로그래픽 Zone Plate 제작 및 해석)

  • 임용석;이영락;곽종훈;최옥식
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.19-25
    • /
    • 1997
  • Holographic zone plate (HZP) is fabricated by interfering a plane wave and a spherical wave in a dichromated gelatin (DCG) film obtained from Agfa 8E75HD plates. We have developed a simple theory for HZP considering optical nonlinearity of DCG material. Analysis of our theory for HZP shows that it has infinite focal points at distances f,f/2, f/3,,…. In experiment, we observed the corresponding focal points of up to f/6 when illuminating HZP by a plane wave. It is also shown that the beam profile around the first focal point measured by using a knife-edge scanning method has a Gaussian shape.

  • PDF

Optical Analysis of Diffraction Grating and Fresnel Zone Plate Fabricated on Fused Silica Glass by a Femtosecond Laser (펨토초 레이저를 이용한 회절격자와 Fresnel Zone Plate 제작 및 광학적 분석)

  • Ryu, Jin-Chang;Kim, Jin-Tae;Sohn, Ik-Bu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.3
    • /
    • pp.18-26
    • /
    • 2010
  • Diffraction gratings with precise spatial periods of 2 ${\mu}m$ and 5 ${\mu}m$ have been fabricated by using a femtosecond laser which does not have limits on materials of micromachining and small thermal effects due to high peak power. Diffraction angle and diffraction efficiency of those were measured. Simulation results of diffraction angle and diffraction efficiency of the diffraction grating calculated with the parameters such as line width, depth, and spatial period of the fabricated gratings were compared with experimental results measured with a He-Ne laser. Besides these, Fresnel Zone Plates (FZPs) with focal distances of 50 mm and 25 mm were fabricated and focal distances of fabricated FZP were measured. Those experimental results for diffraction gratings and FZPs match well with experimental results.

Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography (복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향)

  • Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

A study for Earthquake Parameter of Uljin Earthquake (울진지진(2004/05/29)의 지진원 특성에 관한 연구)

  • Kim, Jun-Kyoung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.6
    • /
    • pp.33-39
    • /
    • 2007
  • The seismic source parameters of the Uljin earthquake on 29 May 2004, including focal depth, focal mechanism, magnitude, and moment tensor elements for source characteristics, are analysed using moment tensor seismic source inversion. The Green‘s function for 3 crust models representing the southern Korean Peninsula are used. Also 3 kinds of epicenters are used to find optimum solution for seismic source parameters. Results show that seismic source parameters have a little dependency of azimuthal distribution and epicentral distances of seismic stations. Final results show that the event, considering 6 moment tensor elements, is caused by the typical reverse fault with nearly NS strike. The focal mechanism implies that the tectonic force around epicenter area currently has compressive environment, with nearly EW principal axis. The focal depth is estimated to be about 12km. The resultant focal mechanism show fairly good agreement to those of other studies. However, focal depth is much different from that of other studies.

A study for Earthquake Parameter of Ulgin Earthquake (울진지진(2004/05/29)의 지진원상수에 관한 연구)

  • Yoo, Seong-Hwa;Kim, Jun-Kyoung;Oh, Tea-Suk
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.69-74
    • /
    • 2007
  • The source mechanism parameters of the Ulgin earthquake on 29 May 2004 are analyser using moment tensor inversion technique. The Green's function are calculated for the Kim's(1985) crust model of southern Korean Peninsula. Results derived from the Ulgin earthquake show the dependence of azimuthal station distribution and epicentral distances. final results show fairly good agreement to those of other authors. the focal mechanism for the Ulgin earthquake is found to be oblique reverse motion with NNE strike. The focal depth is estimated to be 10-12km.

  • PDF

CNT-BASED FIELD EMISSION X-RAY SOURCE

  • Kim, Hyun Suk;Lee, Choong Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.433-433
    • /
    • 2016
  • Carbon nanotubes (CNT) emitter has widely become an attractive mechanism that draws growing interests for cold cathode field emission. CNT yarns have demonstrated its potential as excellent field emitters. It was demonstrated that a small focal spot size was achieved by manipulating some electrical parameters, such as applied bias voltage at the mesh gate, and electrostatic focal lenses, geometrical parameters, such as axial distances of the anode, and the electrostatic focal lens from the cathode assembly, and the dimension of the opening of the electrostatic lens. Electrical-optics software was used to systematically investigate the behavior of the electron beam trajectory when the aforementioned variables were manipulated. The results of the experiment agree with the theoretical simulation results. Each variable has an individual effect on the electron beam focal spot size impinging on the target anode. An optimum condition of the parameters was obtained producing good quality of X-ray images. Also, MWCNT yarn was investigated for field emission characteristics and its contribution in the X-ray generation. The dry spinning method was used to fabricate MWCNT yarn from super MWCNTs, which was fabricated by MW-PECVD. The MWCNT yarn has a significant field emission capability in both diode and the triode X-ray generation structure compared to a MWCNT. The low-voltage-field emission of the MWCNT yarn can be attributed to the field enhancing effect of the yarn due to its shape and the contribution of the high-aspect-ratio nanotubes that protrude from the sides of the yarn. Observations of the use of filters on the development of X-ray images were also demonstrated. The amount of exposure time of the samples to the X-ray was also manipulated. The MWCNT yarn can be a good candidate for use in the low voltage field emission application of X-ray imaging.

  • PDF