• Title/Summary/Keyword: Focal distance

Search Result 156, Processing Time 0.029 seconds

Impact of Feature Positions on Focal Length Estimation of Self-Calibration (Self-calibration의 초점 거리 추정에서 특징점 위치의 영향)

  • Hong Yoo-Jung;Lee Byung-Uk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.4C
    • /
    • pp.400-406
    • /
    • 2006
  • Knowledge of camera parameters, such as position, orientation and focal length, is essential to 3D information recovery or virtual object insertion. This paper analyzes the error sensitivity of focal length due to position error of feature points which are employed for self-calibration. We verify the dependency of the focal length on the distance from the principal point to feature points with simulations, and propose a criterion for feature selection to reduce the error sensitivity.

A Study on Determination of the Focal Plane of Particle in Digital Particle Holography (디지털 입자 홀로그래피에서 입자의 초점면 결정에 관한 연구)

  • Yang, Yan;Kang, Bo-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.5
    • /
    • pp.374-381
    • /
    • 2008
  • The correlation coefficient method, which was proposed by our research group, is applied to digital particle holography to locate the focal plane of particles. It uses the fact that the correlation coefficient is maximum at the focal plane. The factors influencing this method are discussed with a numerical simulation of holograms. For real holograms, the Wiener filter was proposed to process both recorded holograms and reconstructed images. The application results using the dot array target showed that the Wiener filter is a very effective tool for processing holography-related images. The effects of the dot size and the object distance on the errors in the determination of the focal plane by the correlation coefficient method were investigated by using the calibration target.

Parameter Estimation for Range Finding Algorithm of Equidistance Stereo Catadioptric Mirrors (등거리 스테레오 전방위 렌즈의 위치 측정 알고리듬을 위한 파라미터 측정에 관한 연구)

  • Choi, Young-Ho;Kang, Min-Goo;Zo, Moon-Shin
    • Journal of Internet Computing and Services
    • /
    • v.8 no.5
    • /
    • pp.117-123
    • /
    • 2007
  • Catadioptric mirrors are widely used in automatic surveillance system. The major drawback of catadioptric mirror is its unequal image resolution. Equidistance catadioptric mirrir can be the solution to this problem. The exact axial alignment and the exact mount of mirror are the sources that can be avoided but the focal length variation is inevitable. In this paper, the effects of focal length variation on the computation of depth and height of object' point are explained and the effective and simple focal length finding algorithm is presented. First two object's points are selected, and the counterparts on the other stereo image are to be found using MSE criterion. Using four pixel distance from the image center, the assumed focal length is calculated. If the obtained focal length is different from the exact focal length, 24mm, the focal length value is modified by the proposed method. The method is very simple and gives the comparable results with the earlier sophisticated method.

  • PDF

The Relationship between the observation distance, scale of buildings and the landscape preference by the landscape types in a suburban rural area (근교농촌의 경관유형에 따른 고층건물의 관찰거리 및 규모와 경관선호도와의 관계)

  • 심준영;김유일
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.25 no.1
    • /
    • pp.112-123
    • /
    • 1997
  • This study investigated the effect of high-rise buildings on the preference for rural landscapes. The study site was a Seoul suburban, Yong-in, which showed typical scenes of rural development. Slides used in the study were taken in Young-in along the national road 45(north-south) and national road 42(east-west). Forty slides reflecting typical characters of Young-in were selected. Among them, ten slides which were selected through factor analysis based on “ruralits”score were used as original slides. They represent ten landscape types. The simulation of original slides was based on the following aspects: a observation distance. number of buildings and landscape types. The preferences for the landscapes were tested by 200 respondents on 40 slides: Distance(2) ${\times}$ Landscape type(10) = 20 slides, Number of buildings(2) ${\times}$ Landscape type(10) = 20 slides. The following results are found: 1) When high-rise buildings are introduced into rural scenes, there are some vulnerable landscape types: the landscape with high “rurality”, the landscape with background skyline and the focal landscape. 2) The observation distance affects landscape preference. The hypothesis that the nearer the distance the lower the preferences, is accepted. However, there are some exceptions in 3 landscape types. 3) The hypothesis that the more the number of buildings, the lower the preferences, is rejected. The result is quite unexpected one. When a single building is introduced in natural scene, it draws more attention as a focal point than a group of buildings, and subsequently the visual impact is stronger.

  • PDF

The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC (자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향)

  • Yoon, Seok-Hwan;Choi, Jun-Gu;Han, Dong-Kyoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.23-30
    • /
    • 2007
  • This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detertor acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AWC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used,the dose necessary for image acquisition decreased as the grid ratio became higher and the distance became further. but detector acquisition dose was not reduced when in applied AEC. When purchasing digiral medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the equipments. Radiography error made by radiation technologist and unnenessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

  • PDF

Virtual portraits from rotating selfies

  • Yongsik Lee;Jinhyuk Jang;SeungjoonYang
    • ETRI Journal
    • /
    • v.45 no.2
    • /
    • pp.291-303
    • /
    • 2023
  • Selfies are a popular form of photography. However, due to physical constraints, the compositions of selfies are limited. We present algorithms for creating virtual portraits with interesting compositions from a set of selfies. The selfies are taken at the same location while the user spins around. The scene is analyzed using multiple selfies to determine the locations of the camera, subject, and background. Then, a view from a virtual camera is synthesized. We present two use cases. After rearranging the distances between the camera, subject, and background, we render a virtual view from a camera with a longer focal length. Following that, changes in perspective and lens characteristics caused by new compositions and focal lengths are simulated. Second, a virtual panoramic view with a larger field of view is rendered, with the user's image placed in a preferred location. In our experiments, virtual portraits with a wide range of focal lengths were obtained using a device equipped with a lens that has only one focal length. The rendered portraits included compositions that would be photographed with actual lenses. Our proposed algorithms can provide new use cases in which selfie compositions are not limited by a camera's focal length or distance from the camera.

Analytical Study of the Image Reconstruction of Fourier Holograms Using Varifocal Electric-Field-Driven Liquid Crystal Fresnel Lenses

  • Kim, Taehyeon;Lee, Seung-Chul;Park, Woo-Sang
    • Current Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.115-120
    • /
    • 2020
  • A novel method is proposed for controlling the distance of an image plane in Fourier holograms using varifocal electric-field-driven liquid-crystal (ELC) lenses. Phase Fresnel lenses are employed to reduce the thickness and response time of the ELC lenses. The voltages applied to the electrodes of the ELC Fresnel lens are adjusted so that the lens has the same retardation distribution as an ideal lens. The focal length can be controlled by changing the retardation distribution with the applied voltages. Simulations were conducted for the image reconstruction of Fourier holograms with various focal lengths of the ELC Fresnel lenses. The simulation results indicate that the distance of the image plane can be properly controlled with the varifocal ELC Fresnel lens.

Effects of the Welding Parameters on the Weld Shape in Nd:YAG Laser Welding of STS 304L (STS 304L의 Nd:YAG 레이저 용접에서 용접조건이 용접부 형상에 미치는 영향)

  • 이형근;석한길;한현수;박울재;홍순복
    • Journal of Welding and Joining
    • /
    • v.22 no.1
    • /
    • pp.58-64
    • /
    • 2004
  • The control of the weld bead shape is important in laser welding of the small parts. The effects of laser welding parameters on the weld bead shape in the pulsed Nd:YAG laser welding of STS 304L material were investigated. Shielding gas type, flow rate, pumping voltage, pulse frequency, pulse width, focal position and overlap distance were selected as laser welding parameters. Experiments were designed and conducted using the Taguchi method which was a statistical experimental method. The weld bead width, penetration, area and aspect ratio were measured and analysed as the weld bead shape properties and the welding parameters were optimized to maximize the weld aspect ratio. Weld aspect ratio were greatly affected by the pulse width, pumping voltage and pulse frequency, and somewhat by the overlap distance, and little by the shielding gas type, flow rate and focal position. A confirmation experiment were conducted using the optimized welding parameters.

An Exploratory Research on MNC Parents' Motivation to Facilitate Reverse Knowledge Transfer (다국적기업 본사의 역지식이전 동기요인에 대한 탐색적 연구)

  • Hong, Sung-Jin;Yang, Oh-Suk
    • Asia-Pacific Journal of Business
    • /
    • v.10 no.3
    • /
    • pp.53-67
    • /
    • 2019
  • Reverse knowledge transfer has been an important research theme in the literature on multinational corporations (MNCs). This paper proposes major determinants of MNC headquarters' willingness to adopt and use marketing knowledge from their subsidiaries. We argue that the willingness will be jointly determined by both the headquarter's absorptive capacity and the focal subsidiary's transfer capacity and willingness to transfer. In addition, we argue that these capability and motivation effects are moderated by (1) institutional distance between home and the focal host country, (2) the need to unlearn existing routines, and (3) types of entry modes. This paper contributes to the reverse knowledge transfer literature by proposing the argument that both motivational and capability factors are likely to determine the MNC parents' willingness to adopt and use marketing knowledge from their subsidiaries.

Camera calibration parameters estimation using perspective variation ratio of grid type line widths (격자형 선폭들의 투영변화비를 이용한 카메라 교정 파라메터 추정)

  • Jeong, Jun-Ik;Choi, Seong-Gu;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.30-32
    • /
    • 2004
  • With 3-D vision measuring, camera calibration is necessary to calculate parameters accurately. Camera calibration was developed widely in two categories. The first establishes reference points in space, and the second uses a grid type frame and statistical method. But, the former has difficulty to setup reference points and the latter has low accuracy. In this paper we present an algorithm for camera calibration using perspective ratio of the grid type frame with different line widths. It can easily estimate camera calibration parameters such as lens distortion, focal length, scale factor, pose, orientations, and distance. The advantage of this algorithm is that it can estimate the distance of the object. Also, the proposed camera calibration method is possible estimate distance in dynamic environment such as autonomous navigation. To validate proposed method, we set up the experiments with a frame on rotator at a distance of 1, 2, 3, 4[m] from camera and rotate the frame from -60 to 60 degrees. Both computer simulation and real data have been used to test the proposed method and very good results have been obtained. We have investigated the distance error affected by scale factor or different line widths and experimentally found an average scale factor that includes the least distance error with each image. The average scale factor tends to fluctuate with small variation and makes distance error decrease. Compared with classical methods that use stereo camera or two or three orthogonal planes, the proposed method is easy to use and flexible. It advances camera calibration one more step from static environments to real world such as autonomous land vehicle use.

  • PDF