• Title/Summary/Keyword: Focal Element

Search Result 62, Processing Time 0.025 seconds

Detector Mount Design for IGRINS

  • Oh, Jae Sok;Park, Chan;Cha, Sang-Mok;Yuk, In-Soo;Park, Kwijong;Kim, Kang-Min;Chun, Moo-Young;Ko, Kyeongyeon;Oh, Heeyoung;Jeong, Ueejeong;Nah, Jakyoung;Lee, Hanshin;Jaffe, Daniel T.
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.177-186
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG Focal Plane Array (H2RG FPA) detectors. We present the design and fabrication of the detector mount for the H2RG detector. The detector mount consists of a detector housing, an ASIC housing, a Field Flattener Lens (FFL) mount, and a support base frame. The detector and the ASIC housing should be kept at 65 K and the support base frame at 130 K. Therefore they are thermally isolated by the support made of GFRP material. The detector mount is designed so that it has features of fine adjusting the position of the detector surface in the optical axis and of fine adjusting yaw and pitch angles in order to utilize as an optical system alignment compensator. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the structural and thermal analysis, the designed detector mount meets an optical stability tolerance and system thermal requirements. Actual detector mount fabricated based on the design has been installed into the IGRINS cryostat and successfully passed a vacuum test and a cold test.

Performance Analysis for Mirrors of 30 cm Cryogenic Space Infrared Telescope

  • Park, Kwi-Jong;Moon, Bong-Kon;Lee, Dae-Hee;Jeong, Woong-Seob;Nam, Uk-Won;Park, Young-Sik;Pyo, Jeong-Hyun;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.3
    • /
    • pp.321-328
    • /
    • 2012
  • We have designed a 30 cm cryogenic space infrared telescope for astronomical observation. The telescope is designed to observe in the wavelength range of 0.5~2.1 ${\mu}m$, when it is cooled down to 77 K. The result of the preliminary design of the support structure and support method of the mirror of a 30 cm cryogenic space infrared telescope is shown in this paper. As a Cassegrain prescription, the optical system of a 30 cm cryogenic space infrared telescope has a focal ratio of f/3.1 with a 300 mm primary mirror (M-1) and 113 mm secondary mirror (M-2). The material of the whole structure including mirrors is aluminum alloy (Al6061-T6). Flexures that can withstand random vibration were designed, and it was validated through opto-mechanical analysis that both primary and secondary mirrors, which are assembled in the support structure, meet the requirement of root mean square wavefront error < ${\lambda}/8$ for all gravity direction. Additionally, when the M-1 and flexures are assembled by bolts, the effect of thermal stress occurring from a stainless steel bolt when cooled and bolt torque on the M-1 was analyzed.

A CASE REPORT OF ANEURYSMAL BONE CYST OF THE MANDIBULAR CONDYLE (하악과두에 발생한 동맥류성골낭)

  • Ko Jae-Hee;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.231-241
    • /
    • 1997
  • The aneurysmal bone cyst is a nonmalignant reactive bone lesion. Developing rarely in the craniofacial region, and more commonly affecting the long bones and the spine, the lesion has variable etiopathogenic characteristics. The authors diagnosed a 33-year-old female as aneurysmal bone cyst after undergoing clinical, radiological and histological examinations. The characteristics were as followed: 1. The patient complained of pain and swelling of the right preauricular area. 2. The conventional radiograms showed a relatively well defined radiolucent lesion with partially scalloping margin. The cortical bone of the right condyle was thinned and expanded by the lesion. 3. Bone scintigraphy with ~c demonstrated ring-like or doughnut-pattern accumulation of radioactivity. 4. On Tl-weighted imaging of MRI, the lesion on the right condyle had middle signal intensity. T2-weighted MRI demonstrated multiple high signal intensities seperated by septa which had low signal intensity. Finger in balloon appearance was seen. 5. Histologically, the lesion was composed of large sinusoidal blood spaces lined by fibroblasts and histiocytes. Its fibrous stroma consisted of fibroblstic element, multinucleated giant cells, extravasated erythrocytes and focal hemosiderin pigmentation. New bone formation was also observed around larger sinusoidal spaces.

  • PDF

Efficient Implementation of Synthetic Aperture Imaging with Virtual Source Element in B-mode Ultrasound System Based on Sparse Array (희박 어레이 기반의 효율적인 양방향 화소단위 집속 기법의 구현)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.419-430
    • /
    • 2002
  • In this paper. we propose an efficient method for implementing hi-directional pixel-based focusing(BiPBF) based on a sparse array imaging technique. The proposed method can improve spatial resolution and frame rate of ultrasound imaging with reduced hardware complexity by synthesizing transmit apertures with a small number of sparsely distributed subapertures. As the distance between adjacent subapertures increases, however. the image resolution tends to decrease due to the elevation of grating lobes. Such grating lobes can be eliminated in conventional synthetic aperture imaging techniques. On the contrary, grating lobes arisen from employing sparse synthetic transmit apertures can not be eliminated, which has been shown analytically in this paper. We also propose the condition and method for suppressing the grating lobes below -40dB, which is generally required in practical imaging. by placing the transmit focal depth at a near depth and properly selecting the subaperture distance in Proportion to receive aperture size. The results of both the Phantom and in vivo experiments show that the proposed method implements two-wav dynamic focusing using a smaller number of subapertures, resulting in reduced system complexity and increased frame rate.

A Study on the City Hotels from the Perspective of Space Marketing - Focus on the Boutique Hotels - (공간마케팅의 관점에서 본 도시호텔에 관한연구 - 부티크 호텔사례를 중심으로 -)

  • Cha, Jael-Kyung;Lim, Yeonghwan
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.3
    • /
    • pp.119-127
    • /
    • 2012
  • In correlation to the rapid growth of Korea's economy and increased international exchange, hotel architecture in Korea has likewise evolutionized in its own distinctive style. Since hotels accomodate foreign visitors, they should be representative of the local architecture in which they reside, to add to the experience of the regions culture. City hotels provide not only primary housing functions but also many different varieties of services. Furthermore, city hotels operate as a focal point for their local communities. Seoul announced special measures for the expansion of accommodations for foreign tourists, and a large number of hotel construction entities have consequently propagated. Unfortunately, the designs for most of these new hotels have failed to reflect their local cultural characteristics, with most having similar designs and programs. As Korea enters an era seeing ten million foreign tourists annually, progressive reform is especially necessary. Space marketing, which is based on strategies of cultural experience, is a crucial element to city boutique hotel planning. It must be applied to satisfy both the cultural needs of its local communities and well as to vitalize the local economy through development of cultural tourism. To date, there have been numerous studies on boutique hotels and space marketing. However, most of these studies are limited to interior designs and artistic trends rather than focusing on the unique architectural and public aspects of their respective cities. In this thesis, the overall aim and strategies of space marketing for the city boutique hotel are analyzed, and the elements of strategies are used for further case analysis. The purpose of this study is to find applicability of Korean boutique hotel development through the result of case studies. Also, this thesis aims to advocate space marketing for Korea's forthcoming boutique hotels, as a means to showcase its unique cultural assets as well as to advance its international appeal and competitiveness.

  • PDF

Synergistic anticancer effects of timosaponin AIII and ginsenosides in MG63 human osteosarcoma cells

  • Jung, Okkeun;Lee, Sang Yeol
    • Journal of Ginseng Research
    • /
    • v.43 no.3
    • /
    • pp.488-495
    • /
    • 2019
  • Background: Timosaponin AIII (TA3) is a steroidal saponin extracted from Anemarrhena asphodeloides. Here, we investigated the anticancer effects of TA3 in MG63 human osteosarcoma cells. TA3 attenuates migration and invasion of MG63 cells via regulations of two matrix metalloproteinases (MMPs), MMP-2 and MMP-9, which are involved with cancer metastasis in various cancer cells. TA3 reduced enzymatic activities and transcriptional expressions of MMP-2 and MMP-9 in MG63 cells. TA3 also inhibited Src, focal adhesion kinase, extracellular signal-regulated kinase (ERK1/2), c-Jun N-terminal kinase (JNK), p38, ${\beta}-catenin$, and cAMP response element binding signaling, which regulate migration and invasion of cells. TA3 induced apoptosis of MG63 cells via regulations of caspase-3, caspase-7, and poly(ADP-ribose) polymerase (PARP). Then, we tested several ginsenosides to be used in combination with TA3 for the synergistic anticancer effects. We found that ginsenosides Rb1 and Rc have synergistic effects on TA3-induced apoptosis in MG63 cells. Methods: We investigated the anticancer effects of TA3 and synergistic effects of various ginseng saponins on TA3-induced apoptosis in MG63 cells. To test antimetastatic effects, we performed wound healing migration assay, Boyden chamber invasion assays, gelatin zymography assay, and Western blot analysis. Annexin V/PI staining apoptosis assay was performed to determine the apoptotic effect of TA3 and ginsenosides. Results: TA3 attenuated migration and invasion of MG63 cells and induced apoptosis of MG63 cells. Ginsenosides Rb1 and Rc showed the synergistic effects on TA3-induced apoptosis in MG63 cells. Conclusions: The results strongly suggest that the combination of TA3 and the two ginsenosides Rb1 and Rc may be a strong candidate for the effective antiosteosarcoma agent.

A study on the laser surface hardening of SM 45C steel (SM 45C강의 레이저 표면경화처리에 관한 연구)

  • 나석주;김성도;이건이;김태균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.1
    • /
    • pp.53-62
    • /
    • 1987
  • High power lasers provide a controllable and precise energy source in surface transformation hardening. A careful control of the process is needed in order that the surface layer of the material reaches the austenizing temperature, but that it does not melt. In order to achieve this the results of theoretical and experimental studies on the laser surface hardening of a medium carbon steel are described. A two-dimensional computer program, which can be used generally for the determination of transient temperature distributions in welding and heat treatment, was established on the basis of the finite element method. For the confirmation of the accuracy of the numerical analysis, a medium carbon steel (SM 45C) of 5mm thickness was heat-treated with a 1kW CW CO$_{2}$ laser machine, while the traverse speed and the distance from the focal point (defocused distance) were varied. Experimental and numerical results showed a similar tendency in correlations between the hardened zone shape and the process parameters. With increasing beam spot diameter the width and depth of the hardened zone increased for relatively small beam spot diameters, but decreased rapidly after reaching the maximum value, while with increasing traverse speed the width and depth of the hardened zone decreased monotonously. Too small beam spot diameters are to be avoided, since the surface melting would lower the surface hardness and produce an uneven surface which may be unacceptable because of the possible requirement for subsequent machining. It could be observed that for a given traverse speed and laser power input there exists a optimal range of the beam spot diameter, which produce a large width of the hardened zone but no melting on the surface.

IGRINS Mirror Mount Design for Three Off-Axis Collimators and One Slit-Viewer Fold Mirror

  • Rukdee, Surangkhana;Park, Chan;Kim, Kang-Min;Lee, Sung-Ho;Chun, Moo-Young;Yuk, In-Soo;Oh, Hee-Young;Jung, Hwa-Kyoung;Lee, Chung-Uk;Lee, Han-Shin;Rafal, Marc D.;Barnes, Stuart;Jaffe, Daniel T.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.2
    • /
    • pp.233-244
    • /
    • 2012
  • The Korea Astronomy and Space Science Institute and the Department of Astronomy at the University of Texas at Austin are developing a near infrared wide-band high resolution spectrograph, immersion grating infrared spectrometer (IGRINS). The compact white-pupil design of the instrument optics uses seven cryogenic mirrors, including three aspherical off-axis collimators and four flat fold mirrors. In this study, we introduce the optomechanical mount designs of three off-axis collimating mirrors and one flat slit-viewer fold mirror. Two of the off-axis collimators are serving as H and K-band pupil transfer mirrors, and are designed as system alignment compensators in combination with the H2RG focal plane array detectors in each channel. For this reason, the mount designs include tip-tilt and parallel translation adjustment mechanisms to properly perform the precision alignment function. This means that the off-axis mirrors' optomechanical mount designs are among the most sensitive tasks in all IGRINS system hardware. The other flat fold mirror is designed within its very limitedly allowed work space. This slit-viewer fold mirror is mounted with its own version of the six-point kinematic optics mount. The design work consists of a computer-aided 3D modeling and finite element analysis (FEA) technique to optimize the structural stability and the thermal behavior of the mount models. From the structural and thermal FEA studies, we conclude that the four IGRINS mirror mounts are well designed to meet all optical stability tolerances and system thermal requirements.

The Role of F-18 Fluorodeoxyglucose Positron Emission Tomography in Patients with Malignant Mixed Mullerian Tumors of the Uterus (자궁의 악성 혼합성 뮬러리안 종양 환자에서의 FDG PET의 역할)

  • Hidayat, Basuki;Cheon, Gi-Jeong;Chae, Min-Jeong;Kim, Moon-Hong;Kim, Min-Suk;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.16-22
    • /
    • 2006
  • Purpose: Malignant Mixed Mullerian Tumor (MMMT) of the uterine corpus is one of the very uncommon and the most lethal tumors in the uterus. The aim of this study was to evaluate the role of FDG PET in detecting distant metastasis and residual and/or recurrent disease. Methods: Ten patients who underwent FDG PET for detecting distant metastasis and recurrence were included. focal FDG accumulation was regarded as abnormal. We also reviewed serum CA 125 levels, anatomical images, and histopathoiogical examination. Results: Three patients of 10 FDG PET showed abnormal FDG uptake. One had high serum CA 125 levels and high fractions of carcinomatous element on histopathologic examination. FDG PET showed metastatic lesions in unexpected locations, which could not be detected by anatomical images. Another had normal serum CA 125 levels with high sarcomatous element and CT could only detect a few lesions. The other had high serum CA 125 levels and also had high carcinomatous element. Seven patients who had no abnormal uptake on FDG PET had no clinical evidence of recurrence during the follow up period ($51.7{\pm}12.2$ months). The mean disease free intervals of these 7 patients were $36.4{\pm}6.0$ months. Two patients with abnormal findings had never become disease-free condition during the follow up period ($6.0{\pm}4.2$ months. Conclusion: FDG PET could be a useful modality for unexpected distant metastasis and follow up tool in patients with MMMT.

STSAT-3 Main Payload, MIRIS Flight Model Developments

  • Han, Won-Yong;Lee, Dae-Hee;Park, Young-Sik;Jeong, Woong-Seob;Ree, Chang-Hee;Moon, Bong-Kon;Park, Sung-Joon;Cha, Sang-Mok;Nam, Uk-Won;Park, Jang-Hyun;Lee, Duk-Hang;Ka, Nung-Hyun;Seon, Kwang-Il;Yang, Sun-Choel;Park, Jong-Oh;Rhee, Seung-Wu;Lee, Hyung-Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.40.1-40.1
    • /
    • 2010
  • The Main payload of the STSAT-3 (Korea Science & Technology Satellite-3), MIRIS (Multipurpose Infra-Red Imaging System) has been developed for last 3 years by KASI, and its Flight Model (FM) is now being developed as the final stage. All optical lenses and the opto-mechanical components of the FM have been completely fabricated with slight modifications that have been made to some components based on the Engineering Qualification Model (EQM) performances. The components of the telescope have been assembled and the test results show its optical performances are acceptable for required specifications in visual wavelength (@633 nm) at room temperature. The ensuing focal plane integration and focus test will be made soon using the vacuum chamber. The MIRIS mechanical structure of the EQM has been modified to develop FM according to the performance and environment test results. The filter-wheel module in the cryostat was newly designed with Finite Element Analysis (FEM) in order to compensate for the vibration stress in the launching conditions. Surface finishing of all components were also modified to implement the thermal model for the passive cooling technique. The FM electronics design has been completed for final fabrication process. Some minor modifications of the electronics boards were made based on EQM test performances. The ground calibration tests of MIRIS FM will be made with the science grade Teledyne PICNIC IR-array.

  • PDF