• Title/Summary/Keyword: Focal Element

Search Result 62, Processing Time 0.023 seconds

Realization of Focal Accent in VP-ellipsis (동사구 생략에서의 초점억양 실현양상)

  • Kim, Hee-Sung;Lee, Young-Jae;Kim, Kee-Ho
    • Speech Sciences
    • /
    • v.9 no.3
    • /
    • pp.237-250
    • /
    • 2002
  • Linguistically, 'Focus' is the element which includes new or unpresupposed information. It is usually signalled by prosodic prominence called the 'pitch accent'. The purpose of this study is to observe the realization of the focal accent in VP-ellipsis, especially, to affect the meaning recovery of elided VP. Asher (1999) gave evidence that focal stress should be on the higher verb and the AUX in order to recover the elided VP to the lower one. In this paper, the systematic patterning of focal accent to decide the elided meaning in VP-ellipsis is to be observed. The realization of focal accent by English native speakers is set as the criteria for the meaning recovery of the elided VP and is compared to Koreans'. Moreover, the focal accents of Koreans are observed and compared with respect to their English proficiency levels.

  • PDF

Property of Focal Spot of Electron Beam Depending on the Anode Angle of X-ray Tube Using a Finite Element Method (유한요소법을 이용한 X-선관 양극각도에 의존하는 전자빔 초점 특성 연구)

  • Park, Tae-Young;Noh, Young-Il;Lee, Sang-Suk;Park, Rae-Jun;Kim, Ki-Seon
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.2
    • /
    • pp.52-57
    • /
    • 2015
  • The focal spot of electron beam depending on the anode angle in the structure and major parts of the X-ray tube was investigated by the OPERA-3D/SCALAR simulation program. The simulation worked on four spaces with with two spaces, including anode and cathode of X-ray tube, by applying the finite element method analysis. The analytical model and dimension for the emission orbit of thermal electrons made from one filament of the focused X-ray cathode is affected to the penumbra of detector for the X-ray depending on any real focal spot size. The model shape of focusing cap and focusing tube with an anode target angle and a cathode filament is analyzed by the current density distribution of thermal electrons. The focusing width of thermal electrons for the X-ray tube depended on the anode angle (${\theta}$). The focusing value of electron beams at a region of anode angle having $10^{\circ}{\sim}17^{\circ}$ maintained to below value of $70{\mu}m$. The minimum focal size of the electron beam was $40{\mu}m$ at an anode angle of $15^{\circ}$. The focused X-ray tube of many variables depended on the thermionic emission of hot electrons from the target trajectory. The focusing tube will contribute to the real design of X-ray for the development of future diagnosis medical device.

Focal Length Control of Line-focus Ultrasonic Transducer Using Bimorph-type Bending Actuator (바이몰프형 밴딩 액츄에이터를 이용한 선집속형 초음파 트랜스듀서의 초점 거리 제어)

  • 채민구;하강열;김무준
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.202-207
    • /
    • 2003
  • For medical ultrasonic transducer, phase-weighting method has been used for controlling focal length with electric circuit at each vibrating element. However, the electric circuit is complex as the number of vibrating elements is increased. In this paper, we fabricated line-focus transducer with a bimorph-type piezoelectric actuator. The polyvinylidene fluoride (PVDF) piezoelectric type polymer film is used for transmitting and receiving of ultrasonic signal. Using this transducer, focal length of the transducer can be controlled mechanically by changing voltage of the actuator. It is confirmed that focal length of the transducer can be controlled in range of 1095 to radius of curvature.

Design and Experimental Demonstration of Coaxially Folded All-reflective Imaging System

  • Xiong, Yupeng;Dai, Yifan;Chen, Shanyong;Tie, Guipeng
    • Current Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.227-235
    • /
    • 2019
  • With slimmer, lighter and all-reflective imaging systems in high demand for consumer and military applications, coaxially folded optical image systems are widely considered because they can extend focal length and reduce track length. Most of these systems consist of multiple surfaces, and these surfaces are machined on one element or grouping processing on two elements. In this paper, we report and first experimentally demonstrate an all-aluminum all-reflective optical system which consists of two optical elements, with two high order aspherical surfaces in each element. The coaxially folded system is designed with Seidel aberration theory and advanced optimization with Zemax. The system is made of all-aluminum material processing by single point diamond turning (SPDT). On this basis, we completed the system integration and performed an imaging experiment. The final system has the advantages of short track length and long focal length and broad application prospects in the micro-unmanned aerial vehicle field.

Surface Topographical Cues for Regulating Differentiation of Human Neural Stem Cells

  • Yang, Kisuk;Lee, Jong Seung;Lee, Jaehong;Cheong, Eunji;Lee, Taeyoon;Im, Sung Gap;Cho, Seung-Woo
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.122.2-122.2
    • /
    • 2016
  • Surface topographical cues has been highlighted to control the fate of neural stem cells (NSCs). Herein we developed a hierarchically patterned substrate (HPS) platform for regulating NSC differentiation. The HPS induced cytoskeleton alignment and highly activated focal adhesion in hNSCs as indicated by enhanced expression of focal adhesion proteins such as focal adhesion kinase (FAK) and vinculin. hNSCs cultured on HPS exhibited enhanced neuronal differentiation compared to flat group. We also developed a graphene oxide (GO)-based hierarchically patterned substrates (GPS) that promote focal adhesion formation and neuronal differentiation of hNSCs. Enhanced focal adhesion and differentiation of hNSCs on the HPS was reversed by blocking the ${\beta}1$ integrin binding and mechanotransduction-associated signals including Rho-associated protein kinase (ROCK) and extracellular-regulated kinase (ERK) pathway, which may suggest a potential mechanism of beneficial effects of HPS. In addition, hNSCs on the HPS differentiated into functional neurons exhibiting sodium currents and action potentials as confirmed by whole cell patch-clamping analysis. The hierarchical topography can direct differentiation of NSCs towards functional neurons, and therefore would be an important element for the design of functional biomaterials for neural tissue regeneration applications.

  • PDF

A study on evaluation element of technical proposal tendering for apartment remodeling business

  • Park, Min-Young;Lim, Sooyoung
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.61-68
    • /
    • 2015
  • Method of remodeling builder selection for remodeling is competitive bidding. also metropolitan city, megalopolis city, city more than 50million have to do basic plan for remodeling before establishment of a housing cooperative. Purpose of basic plan is improvement of living conditions & the Quality of Life for resident. Technical Proposal Tendering in spite of being the a reasonable bidding system, institutional part, appraisal standard and the item part, consider procedure pard is performed in a similar way to the existing bidding system. so, technical proposal tendering is appropriate for future Method of builder selection of remodeling. therefore, the study purpose is a evaluation element of technical proposal tendering for apartment remodeling business The methods of study is understanding concept through review of precedent literature. Next, case investigation through Analysis of focal points. Lastly, evaluation element deduction of technical proposal tendering for apartment remodeling business through specialist conversation. As a result, Alteration of a right & move management is added to evaluation element's professional field. And detail item is alteration of a right & move management.

A Study on the Con-focal Microscope for the Surface Measurements (공초점 현미경을 이용한 물체표면 형상측정에 관한 연구)

  • 강영준;송대호;유원재;백성훈
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.5
    • /
    • pp.73-81
    • /
    • 2003
  • In case of hollow cylinder extrusion using porthole die, the effects of extrusion parameters-temperature, the speed of extrusion, the shape of the die and mandrel-on metal flow in porthole die extrusion of aluminum have been investigated. However, there have been few studies about condenser tube extruded by porthole die. Original metal flow of condenser tube by porthole die extrusion is similar to hollow cylinder extrusion but the estimation of metal flow for extrusion parameters is different. For example, variation of chamber length in hollow extrusion only affects the welding pressure, however, the welding chamber length in condenser tube extrusion influences to the welding pressure as well as the deflection of mandrel. This study was designed to evaluate metal flow, welding pressure, extrusion load, tendency of mandrel deflection according to angular variation in the bottom of chamber in porthole die. Estimation was carried out using finite element method in as non-steady state. Analytical results can provide useful information the optimal design of porthole die.

Focal Parts of Utterance in Busan Korean

  • Cho, Yong-Hyung
    • Speech Sciences
    • /
    • v.9 no.4
    • /
    • pp.149-163
    • /
    • 2002
  • Focal parts of utterance can be determined by new/contrastive information, a focus particle, a contrastive topic marker, or a nominative case marker in Busan Korean. Among these factors, new or contrastive information is the most important element in determining the intonational nucleus of an utterance. However, unlike Seoul Korean, when a focus particle, a topic marker, or a case marker contributes to the placement of the most prominent peak of an utterance, the peak is on the noun to which they are attached. Moreover, the case marker-ga shows more prominent pitch on the preceding noun than the noun followed by the topic marker-nun when-ga is used as emphatic or contrastive. This is one of the major problems for Busan Korean users in commanding natural and fluent Seoul Korean intonation even if they use standard written form of Seoul Korean in their speech.

  • PDF

Realization for Each Element for capturing image in Scanning Electron Microscopy (주사 전자 현미경에서 영상 획득에 필요한 구성 요소 구현)

  • Lim, Sun-Jong;Lee, Chan-Hong
    • Laser Solutions
    • /
    • v.12 no.2
    • /
    • pp.26-30
    • /
    • 2009
  • Scanning Electron Microscopy (SEM) includes high voltage generator, electron gun, column, secondary electron detector, scan coil system and image grabber. Column includes electron lenses (condenser lens and objective lens). Condenser lens generates fringe field, makes focal length and control spot size. Focal length represents property of lens. Objective lens control focus. Most of the electrons emitted from the filament, are captured by the anode. The portion of the electron current that leaves the gun through the hole in the anode is called the beam current. Electron beam probe is called the focused beam on the specimen. Because of the lens and aperture, the probe current becomes smaller than the beam current. It generate various signals(backscattered electron, secondary electron) in an interaction with the specimen atoms. In this paper, we describe the result of research to develop the core elements for low-resolution SEM.

  • PDF

Shape Error and Its Compensation in the Fabrication of Microlens Array Using Photoresist Thermal Reflow Method (Photoresist thermal reflow 방법을 이용하여 제작한 마이크로렌즈 어레이의 형상 관련 오차 및 이에 대한 보정)

  • Kim, Sin Hyeong;Hong, Seok Kwan;Lee, Kang Hee;Cho, Young Hak
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.2
    • /
    • pp.23-28
    • /
    • 2013
  • Microlens array as basic element of the optical system have been fabricated with various focal length (mainly with long focal length) depending on the purpose of application. In this paper, the microlens arrays were fabricated for observing fluorescent images within sol-gel. Though the fluorescent signal is very low, the microlens array can help obtaining clear images through extracting the fluorescent light from sol-gel. We fabricated microlens arrays with short focal length, which can extract the light using photoresist thermal reflow method. In the experiment, the diameter of microlens decreased after thermal reflow because the solvent within the photoresist was vaporized. Therefore, to compensate the shape error by this reduction, microlens diameter in photomask was altered and spin-coat recipe of photoresist were modified.