• Title/Summary/Keyword: Foam Extinguishing Agents

Search Result 9, Processing Time 0.023 seconds

The Extinguishing Characteristics by Fluidity Variation of Protein Foam Extinguishing Agent (단백포소화약제의 유동성 변화에 따른 소화 특성)

  • Shin, Changsub;Jeong, Hyunjeong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.18-23
    • /
    • 2014
  • Foam extinguishing agent is widely used for extinguishing combustible liquid fires. Compared to other foam type extinguishing agents, protein foam has relatively low cost and low toxicity and produces stable foam blanket which is excellent in heat resistance and sealability, despite it has weak fluidity. Therefore the study investigated foaming characteristics followed by various factors affecting the fluidity of the protein foam extinguishing agent. The extinguishing characteristics differentiated by the changes in fluidity were also experimented. Foaming performance was compared by measuring the expansion ratio and the 25% drainage time. Moreover, the 25% drainage time and the extinguishing time was compared. The results showed that the 25% drainage time and the expansion ratio were increased as the pressure of nozzle and the concentration of hydrolyzed protein liquid enlarged. However the foaming and extinguishing performance were not improved when the condition exceeded certain level of pressure and concentration. The fastest fire extinguishing condition was the nozzle pressure 4bar with the 85wt.% of concentration of hydrolyzed protein liquid.

An Experimental Study on the Improvement of Fire Extinguishing Performance of Water Mist with Foam (포 소화약제를 혼합한 미분무수 소화시스템의 소화성능 향상 방안에 관한 실험적 연구)

  • Hwang, Won-Jun;Kim, Hwang-Jin;Oh, Kyu-Hyung;Lee, Sung-Eun;Kim, Sung-Won
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.61-66
    • /
    • 2009
  • We carried out the water mist fire extinguishing experiments with the 3 kinds of foaming agents varied on the nozzle height. Test result showed that 2% AFFF (Aqueous Film Forming Foam) and 1% synthetic foaming agent for water mist system are the faster extinguishing time than the pure water mist and 3% AFFF solution. Additionally, the best fire extinguishing performance of pure water mist was shown at 3.5m nozzle height and that of the foaming agents shown at 4m nozzle height.

A Study On The Application Of Foam Extinfuishing Agent By Using Halon 1301 And Halon Alternatives (Halon 1301과 Halon 대체 소화약제를 기포제로 이용한 포 소화약제에 대한 연구)

  • Jung, Ki-Chnag;Lim, Sung-Muk;Lee, Chang-Sub;Kang, Young-Goo;Kim, Hong
    • Fire Science and Engineering
    • /
    • v.10 no.3
    • /
    • pp.29-40
    • /
    • 1996
  • The AFFF(Aqueous Film Forming Foam : 3M Company's Light Water) agent are synthetic compounds that foams which are similar to those produced by protein based materials. The foam extinguishing agent was used In the extinguisher was the AFFF agent. We sought, however, to make other foams by using halon 1301 (CF$_3$Br) and halon alternatives, such as HCFC Blend A($CHCIF_2$ 82%, $CF_3$CHCIF 9.5%m $C_{10}$$H_{16}$ 3.75%), HFC-227ea ($CF_3$ $CHFCF_3$) We selected these alternatives instead of air in order to raise the expansion ratio of the AFFF agent. By these means we discovered that it is possible to increase the expansion ratio of the AFFF agent up to 44:1 and up to 24:1 when HFC-227ea was used as a halon alternatives. Therefore our new foam extinguishing agents can be used in a portable extinguish agents can be used in a portable extinguishers.

  • PDF

The Verify of Environmental Toxicity of Foam Extinguishing Agents by Fish-Acute Toxicity Test (포소화약제의 어류급성독성 시험을 통한 환경독성 검증)

  • Lee, Jungyun;Kang, YoungJin;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.51-55
    • /
    • 2015
  • There are various studies on the fire suppression process but the study on second pollution from fire products is not enough yet. Therefor, in this study verify that environmentally-friendly properties($LC_{50}$) of foam extinguishing agent with increases its amount used through with Fish-Acute Toxicity Test using a fish named Misgurnus anguillicaudatus that is appointed by OECD Test Guideline. In conclusion, proven that environmentally friendly properties of the agent of hoseo university through 16 times of LC50 than that of market.

A Study On The Development Of An Automatic Fire Extinguishing System For The Engine Compartment Use Of Automobiles (자동차 엔진 화재용 자동 소화 시스템 개발에 관한 연구)

  • Lim, Sung-Muk;Jung, Ki-Chang;Kim, Hong;Kang, Young-Goo;Lee, Chang-Sub
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.57-61
    • /
    • 1996
  • Our goal was to make a cost-effective automatic fire extinguishing system for the engine compartment use of automobiles. We designed this system for the engine compartment. This system consists of 1)foam extinguisher, 2)four nozzles, 3)a pipe arrangement, and 4)an extinguishing device which is equipped with a glass bulb as detector. First and foremost, the extinguishing device was carefully designed to keep the system cost to a minimum. Second, a AFFF foam extinguisher was used because no other fire-fighting agents proved effective against fire in the engine compartment. The AFFF(Aqueous Film Forming Foam) agent which was used in the extinguisher is the 3M company's Light Water. We sought, however, to make other foams by using Halon 1301 and Halon alternatives such as HCFC Blend A, HFC-227ea. We selected these alternatives instead of air in order to raise the expansion ratio of the AFFF agent. By these means we discovered that it is possible to increase the expansion ration of the AFFF agent up to 44:1. We then demonstrated that our automatic fire extinguishing system is the most effective and lowest cost-system yet devised for passenger cars.

  • PDF

An Experimental Study on the Automobile Engine Room Fire Using the Extinguishing Agents (소화약제를 이용한 자동차 엔진룸 화재 실험에 관한 연구)

  • Han, Yong-Taek;Kim, Dong-Ho;Kwon, Sung-Pil
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • Several complex devices and equipments are installed in the car's engine room, including various kind of oils or other flammable materials. So re-ignition is very likely to take place in it. In addition, it is restrictive for the driver or the occupant to open the bonnet and to spray the fire extinguisher in the engine room due to the high possibility of explosion. Therefore, a fire extinguishing system, which can detect a fire and inject the fire extinguishing agent to extinguish it, and fire extinguishing agents including HFC-227ea, which can stand the high temperature within the engine room and hold the viscosity sufficient to keep it in the kind of foam, were developed and tested. And the suffocation effect and the cooling effect come from the fire extinguishing principle of the foam fire extinguishing agent and the inhibiter catalyst effect come from the one of HFC-227ea was led simultaneously, and fire extinguishing agents without the secondary damage caused by residuals after the fire extinguishment like a case of the powder fire extinguishing agent, were developed. And experiments using a vehicle collision after the discharge is complete, foreign material can be removed without extinguishing the advantage that experimental results obtained.

The Development of an Environmental-Friendly Foam Extinguisher Using a Natural Surfactant (천연계면활성제를 이용한 친환경적 포소화약제 개발)

  • Kim, Jeong-Hun;Lee, Jung-Yun;Kim, Hong;Kim, Eung-Sik;Lee, Myoung-Bo;Kim, Dong-Hyun;Jung, Ki-Chang
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.69-73
    • /
    • 2007
  • In this research, an environmental-friendly foam extinguisher was newly developed using a natural surfactant as its composition. Two criteria were applied to verify its extinguishing performance and environmental attraction. One is unit 2 model by "Standards of Model Approval and Inspection Technology for Portable Fire Extinguishers" presented in Korea Fire Equipment Inspection Corporation. The other is Terrestrial Plants, Growth Test and Fish, Acute Toxicity Test presented in Korea Institute of Toxicology(Korea Research Institute of Chemical Technology). Test results showed that the extinguishing performance was 5 unit of general fire Class A, the $LC_{50}$ by germination was 75(g/kg) and the $EC_{50}$ by growth was 62(g/kg) through Terrestrial Plants, Growth Test, and also the toxicity was 6658 ppm in Fish, Acute Toxicity Test. The numerical values were highly evaluated than other fire extinguishing agents being commercialized in domestic. The results also showed suitably in basic physical properties and anti-corrosion properties for making use of fire extinguishing agent.

THE DEVELOPMENT OF FOAMING AGENTS USING SLES & DH-109EX

  • Hu Rui;Kim, Jeong-Hun;Kim, Min-Kyn;Kang, Young-Goo;Kim, Hong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.582-589
    • /
    • 1997
  • Experiments were conducted to develop foaming agents by using SLES and DH-l09EX as raw material. PG (Propylene glycol) and BC (Butyl cellusolve) were adopted as subsidiary material. The undiluted foam solution was produced with these materials. This solution determined the expansion ratio, viscosity, drainage time and extinguishing ability of the final product. The results indicate that the expansion ratio is over 16 and drainage time is over one minute. The extinguishing ability for SLES system was succeeded in the unit of B-0.5.

  • PDF