• Title/Summary/Keyword: Fluxgate

Search Result 61, Processing Time 0.026 seconds

A study on walking aids for the blind (시각장애자의 보행지원에 관한 연구)

  • Ham, K.K.;Han, S.H.;Yang, S.Y.;Kim, H.G.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.131-135
    • /
    • 1997
  • We implementated an ultrasonic wave cane for the blind. The cane detect walking obstacle and provide a walking direction. The cane used time of flight method of ultrasonic-wave for a measurement of obstacle distance and fluxgate geomagnetic sensor for guidance of walking direction. This system can detect an obstacle of upward, forward, downward and that warn to the blind with vibration, pitch sound. And the blind can know walking direction to voice output. As a result, the blind could efficiently avoid a exposed obstacle, obstacles beyond knee, an exposed street obstacle, a branch of tree person's height and it is usable search for surrounding land mark.

  • PDF

GLOBAL MAPPING OF NEAR-EARTH MAGNETIC FIELDS MEASURED BY KITSAT-1 AND KITSAT-2 (KITSAT-1과 KITSAT-2에서 관측한 지구자기장의 분포)

  • 표유선;이동훈;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.1
    • /
    • pp.81-92
    • /
    • 1994
  • The magnetic field measurements from the KitSat-1 and KitSat-2 were tested by comparing with the IGRF model. The magnetic data have been collected by a three-axis fluxgate magnetometer on each satellite at an latitude of 1,325 km and 820 km, respectively. To avoid highly variable magnetic disturbances at the polar region, the field map has been within the limits of 50 degrees in latitude. Each data is averaged over the square of $5{\times}5$ degrees in both latitude and longitude. In these results, the relatively quiet periods were selected and the sampling rate was 30 seconds. It is shown that the results from these measurements are consistent with the IGRF map over the global surface map.

  • PDF

Demagnetization Performance According to Vertical and Horizontal Magnetic Bias Fields

  • Kim, Young-Hak;Kim, Ki-Chan;Shin, Kwang-Ho;Yoon, Kwan-Seob;Yang, Chang-Seob
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.453-456
    • /
    • 2011
  • Demagnetization for a tube sample which was made of a galvanized steel sheet was performed by applying a magnetic field with a decrement to remove the remanent magnetization of the material. An orthogonal fluxgate magnetic field sensor was used to measure a magnetic field created from a ferromagnetic material. To evaluate the remanent magnetization, the measured magnetic fields were separated into two magnetic field components by the remnant magnetization and the induced one. The horizontal and the vertical bias fields should be controlled separately during demagnetization to remove the horizontal and the vertical components of the remanent magnetization of the tube sample.

Geomagnetic Disturbances by Steel Skeletons (철골에 의한 지자기 교란)

  • 송승한;이문호;배성호;신현진
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.1
    • /
    • pp.32-37
    • /
    • 2001
  • Effects of steel-skeletons on the geomagnetic distribution in building have been studied through the simulation and measurement of geomagnetic distribution at floor surface. Geomagnetic distribution was simulated by the finite element method, and the vertical component Z of geomagnetic field on the floor surface was measured with the fluxgate-type magnetometer. Horizontal steel-skeletons have a little effect on the Z distribution, but vertical skeletons disturb severely the Z distribution and result in the localized geomagnetic disturbance. This disturbance becomes weakened by the bypassing soft-magnetic plate and/or floor.

  • PDF

Magnetic Wireless Motion Capturing System and its Application for Jaw Tracking System and 3D Computer Input Device

  • Yabukami, S.;Arai, K.;Arai, K.I.;Tsuji, S.
    • Journal of Magnetics
    • /
    • v.8 no.1
    • /
    • pp.70-73
    • /
    • 2003
  • We have developed a new tracking system of jaw movement. The system consists of two permanent NdFeB magnets and 32 elements of two-axial fluxgate sensor array, The two magnets are attached to head portion and front tooth. This system does not need any attachments of the head portion or mouth such as clutch or magnetic field sensor except magnets. The proposed system is applicable for five degree of freedom. Position accuracy within 2]m was achieved. We developed a 3D computer input device by using the above mentioned technique.

Development of residual current detector for DC distribution system (직류배전용 누설전류 검출기 개발)

  • Lee, Won-Ki;Han, Byunghun;Jung, Hae-Min;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.53-54
    • /
    • 2013
  • 디지털 제품의 사용 증가로 직류를 사용하는 부하가 급증하고, 태양광발전 등 직류발전의 보급이 확대 되며 직류배전에 대한 관심이 높아지고 있다. 기존 영상변류기(ZCT; Zero phase sequence Current Transformer)를 사용하여 누설전류를 감지하는 교류배전용 차단기는 영상변류기의 특성상 직류에서 적용이 불가능하다. 이에 따라 직류배전에서 누설전류에 의한 사고를 방지하기 위해서 누설전류를 검출하고 차단할 수 있는 장치 개발이 필요하다. 본 논문에서는 직류에서 검출에 문제가 없는 Fluxgate current transducer를 이용하여 직류배전에서 사용 가능한 검출기를 개발하였다.

  • PDF

A small ocean bottom electromagnetometer and ocean bottom electrometer system with an arm-folding mechanism (Technical Report) (팔-접힘 구조를 가지는 소규모 OBEM과 OBE시스템 (기술보고서))

  • Kasaya, Takafumi;Goto, Tada-nori
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.41-48
    • /
    • 2009
  • Natural magnetic fields are attenuated by electrically conductive water. For that reason, marine magnetotelluric surveys have collected data at long periods (1000-100 000 s). The mantle structure has been the main target of seafloor magnetotelluric measurements. To ascertain crustal structure, however, electromagnetic data at shorter periods are important, e.g. in investigations of megathrust earthquake zones, or in natural resource surveys. To investigate of the former, for example, electromagnetic data for periods of less than 1000 s are necessary. Because no suitable ocean bottom electromagnetometer (OBEM) has been available, we have developed a small OBEM and ocean bottom electrometer (OBE) system with a high sample rate, which has an arm-folding mechanism to facilitate assembly and recovering operations. For magnetic observation, we used a fluxgate sensor. Field observations were undertaken to evaluate the field performance of our instruments. All instruments were recovered and their electromagnetic data were obtained. Results of the first experiment show that our system functioned well throughout operations and observations. Results of other field experiments off Tottori support the claim that the electromagnetic data obtained using the new OBEM and OBE system are of sufficient quality for the survey target. These results suggest that this device removes all instrumental obstacles to measurement of electromagnetic fields on the seafloor.

Developement of Detection system of buried Underground Utilities using Magnetic Sensor (자기 센서를 이용한 지하 매설물 탐지 시스템 개발)

  • Cheon Y.S.;Lee J.Y.;Cho C.H.;Ahn K.T.;Yang S.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1819-1823
    • /
    • 2005
  • Incorrect information on public sites can cause serious problem. One of relevant countermeasures against this problem is to detect of buried underground utilities in real time. Although there have been several method to detect of buried underground utilities, such as investigating of gravity and elastic wave and electric field, they have not been so efficient tools. Because it is too expensive and difficult to use. In this paper, magnetic sensors which could provide an easier and more efficient method are used to detect of buried underground utilities. Also fluxgate method of self detection are used. Input signal is used $1\~10kHz$ frequency. Filtering and signal processing of output signal are used labview software. After experiment, detection system of buried underground utilities which used magnetic shows possibility of precise detecting of laying object based on theorectical analysis for electromagnetic field.

  • PDF

Map-Matching Algorithm for MEMS-Based Pedestrian Dead Reckoning System in the Mobile Device (모바일 장치용 MEMS 기반 보행항법시스템을 위한 맵매칭 알고리즘)

  • Shin, Seung-Hyuck;Kim, Hyun-Wook;Park, Chan-Gook;Choi, Sang-On
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.11
    • /
    • pp.1189-1195
    • /
    • 2008
  • We introduce a MEMS-based pedestrian dead reckoning (PDR) system. A walking navigation algorithm for pedestrians is presented and map-matching algorithm for the navigation system based on dead reckoning (DR) is proposed. The PDR is equipped on the human body and provides the position information of pedestrians. And this is able to be used in ubiquitous sensor network (USN), U-hearth monitoring system, virtual reality (VR) and etc. The PDR detects a step using a novel technique and simultaneously estimates step length. Also an azimuth of the pedestrian is calculated using a fluxgate which is the one of magnetometers. Map-matching algorithm can be formulated to integrate the positioning data with the digital road network data. Map-matching algorithm not only enables the physical location to be identified from navigation system but also improves the positioning accuracy. However most of map-matching algorithms which are developed previously are for the car navigation system (CNS). Therefore they are not appropriate to implement to pedestrian navigation system based on DR system. In this paper, we propose walking navigation system and map-matching algorithm for PDR.

DEVELOPMENT OF MAGNETOMETER DIGITAL CIRCUIT FOR KSR-3 ROCKET AND ANALYTICAL STUDY ON CALIBRATION RESULT (KSR-3 과학 로켓용 자력계 디지털 회로 개발 및 검교정시험 결과 분석 연구)

  • 이은석;장민환;황승현;손대락;이동훈;김선미;이선민
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.293-304
    • /
    • 2002
  • This paper describes the re-design and the calibration results of the MAG digital circuit onboard the KSR-3. We enhanced the sampling rate of magnetometer data. Also, we reduced noise and increased authoritativeness of data. We could confirm that AIM resolution was decreased less than InT of analog calibration by a digital calibration of magnetometer. Therefore, we used numerical-program to correct this problem. As a result, we could calculate correction and error of data. These corrections will be applied to magnetometer data after the launch of KSR-3.