• 제목/요약/키워드: Flux2D

검색결과 852건 처리시간 0.025초

충돌수분류(衝突水噴流)에 의한 서브쿨 Burnout열류속(熱流束)에 관한 연구 (Subcooled Burnout Heat Flux on a Heated Surface with Impinging Water Jet)

  • 엄기찬;이종수;박성연
    • 설비공학논문집
    • /
    • 제8권4호
    • /
    • pp.527-536
    • /
    • 1996
  • Convective nucleate boiling and burnout heat flux have been studied on a flat, downward facing, constant heat flux surface cooled by an impinging water jet. The tests are progressed from low, nonboiling power to high, burnout heat flux power. The jet velocity and the subcooling do not affect the nucleate boiling curve of $q{\sim}{\Delta}T_{sat}$ diagram, but the supplementary water height affects the curve. For the case of dimensionless height of supplementary water S/D=1, the boiling curve shift to the heigher heat flux than that of S/D=0 or S/D=2. Burnout heat flux is enhanced with increasing jet velocity and subcooling. Also. by using the supplementary water(S/D=1 or S/D=2), burnout heat flux is larger than that of the simple water jet(S/D=0). A generalized correlation for the burnout heat flux data in the present boiling system with an impinging water jet is successfully evolved.

  • PDF

Characteristic Analysis of a Permanent Magnet Transverse Flux Linear Motor with Spiral Core

  • Lee, Ji-Young;Kim, Ji-Won;Woo, Byung-Chul;Kang, Do-Hyun
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.111-116
    • /
    • 2013
  • This paper presents a characteristic analysis method of a permanent magnet type transverse flux linear motor (TFLM) with spiral cores. The spiral cores are used as the mover cores in order to make 3-dimensional (3-D) magnetic flux paths at the TFLM which have 3-D magnetic flux flows. The 3-D Equivalent Magnetic Circuit Network Method is used to analyse the magnetic characteristics of the machine, and an imaginary part, 'flux barrier,' is introduced to consider the spiral core characteristic. Magnetic parameters such as flux, inductance, and thrust are calculated from the analysis results. The computed thrust forces are compared to measured values to confirm the accuracy of the analysis.

진동만 미더덕 양식장의 하계 및 동계 탄소 순환 특성 (Characteristics of Carbon Circulation for Ascidian Farm in Jindong Bay in Summer and Winter)

  • 박지혜;조윤식;이원찬;홍석진;김형철;김정배;박정현
    • 한국습지학회지
    • /
    • 제14권2호
    • /
    • pp.211-221
    • /
    • 2012
  • 미더덕은 우리나라에서만 식용 및 양식하는 생물종으로, 2001년 본격적인 수하식 양식이 시작되어 15,084 M/T이 생산되었지만 2011년에는 2,655 M/T으로 생산량이 크게 감소하였다. 생산량 저감의 원인분석을 위해서는 어장 환경에 관한 물질수지 산정이 필요하다고 판단된다. 진동만 미더덕 양식장에서 하계와 동계에 현장 관측 장비인 벤틱챔버(BelcI)를 이용하여 미더덕 양식장과 대조구 정점에 대한 침강 flux와 용출 flux를 산정하였다. 7월 양식장, 2월 양식장, 2월 대조구에서 유기 탄소 침강 flux는 각각 72 mmol C $m^{-2}\;d^{-1}$, 93 mmol C $m^{-2}\;d^{-1}$, 34 mmol C $m^{-2}\;d^{-1}$로 나타났고, 유기탄소 산화율은 각각 13 mmol C $m^{-2}\;d^{-1}$, 81 mmol C $m^{-2}\;d^{-1}$, 31 mmol C $m^{-2}\;d^{-1}$로 나타났다. 영양염 용출 flux는 일반적인 경향을 띄었다. 결과적으로 유기탄소 퇴적 flux는 20:4:1의 비를 나타내었다. 탄소 순환의 물질수지 산정을 통해, 양식 생물의 생산량 저감에 관한 원인 분석연구에 기초 자료로써 활용될 수 있다.

유효한 2차원 모델을 이용한 리니어 브레이크 성능 해석 (Performance Analysis of Linear Brake by Using Efficient 2-D Model)

  • 한필완;전연도;이주;이관섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.601-607
    • /
    • 1998
  • This paper presents the efficient 2-D linear brake analysis model which can compensate the lateral leakage flux by changingng the airgap length and magneto-motive force(MMF). The linkage flux of the 2-D analysis is larger than that of 3-D analysis. This is caused by the assumption in 2-D analysis that geometric and physical values are constant along the perpendicular direction(z) to the analysis region. The equivalent MMF have been calculated from the linkage flux difference between the 2-D and 3-D analyses which are performed at zero velocity. The performances of the linear brake have been analyzed effectively by using the compensated 2-D models without using 3-D FEM.

  • PDF

3차원 유한요소법에 의한 2상 8극 HB형 LPM의 가동자의 자속분포 해석 (Analysis of Flux Distribution in 2 Phase 8 Pole HB type LPM by 3D FEM)

  • 이동주;이은웅;김성헌;김성종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.34-36
    • /
    • 1999
  • 2 phase 8 pole HB type LPM(linear pulse motor) has the suitable structure for it's microstep drive. Hence, if this LPM will be drived by this method, the limited(mechanically) step resolution can be increased further and vibration and noise can be decreased considerably. But, It is difficult that this LPM was analyzed in detail because of it's complex magnetic circuits to be composed the LF(longitudinal flux) and TF(transverse flux.) path. If LPM was analyzed by the approximate 2D model, we could not be obtained satisfactory result. Therefore, It is necessary to be analyzed the 3D model in detail for the more satisfactory results. In this paper, we obtain 3D flux distribution of the mover using by 3D FEM(finite element method)

  • PDF

FLUX3D를 이용한 자기부상용 전자석의 특성 해석 (Characteristic Analysis of a Magnet for Magnetically Levitated Vehicle using FLUX3D)

  • 이재건;신판석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.127-129
    • /
    • 1996
  • A 3-dimensional analysis is desired for a magnet of magnetically levitated vehicle because the geometrical shape of the magnet is complicated and nonsymmetric. A FEM package of FLUX3D is used to analyze the characteristic of the magnet. Various quantities could be observed like levitation force, flux density distribution along the air gap, edge and fringing effect, leakage flux pattern, etc. The simulation results from FLUX3D are compared with those of 2-D analysis and test results. There are a little difference between results due to the boundary conditions and magnetized B-H curve of the core.

  • PDF

상부가열인 다공물질내의 열파이프 현상에 관한 실험적 연구 (Experimental study of the heat pipe phenomenon in porous media heated from above)

  • 이진호;김홍제;함윤영;남궁규완
    • 대한기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.825-832
    • /
    • 1988
  • 본 연구에서는 1차원 열흐름하에서 상부가 가열된 다공물질내의 열파이프 현 상과 관련하여 2상영역의 존재와 그 길이에 영향을 미치는 인자들을 실험적으로 관찰, 조사하였다.

Interlaminar Flux Density Distribution at Joints of Overlapping Stacked Electrical Steel and Amorphous Ribbons

  • Erdem, Sezer;Derebasi, Naim
    • Journal of Magnetics
    • /
    • 제15권4호
    • /
    • pp.190-193
    • /
    • 2010
  • The design of joints in a transformer core significantly affects the transformer's efficiency. Air gaps cause variations in the flux distribution at the joints of the laminations, which depend on the geometry. Two similar samples consisting of electrical steel strips and amorphous ribbons were made. The spatial flux distributions were determined using an array of search coils for each sample. 2D models of these samples were created and examined by finite element analysis. The magnetic flux distribution for each lamination in the samples was computed. The results show that the flux density in amorphous ribbons above and below the air gap starts to approach saturation at lower flux density levels than for electrical steel. The flux density measured using the search coil under the air gap is increased in amorphous ribbons and decreased in the electrical steel with increasing frequency.

Dependence of the peak fluxes of solar energetic particles on CME parameters and magnetic connectivity

  • Park, Jinhye;Moon, Yong-Jae;Lee, Harim;Kahler, S.W.
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.82.3-83
    • /
    • 2017
  • We investigate the relationships between the peak fluxes of 18 solar energetic particle (SEP) events and associated coronal mass ejection (CME) 3D parameters (speed, angular width, and separation angle) obtained from SOHO, STEREO-A and/or B for the period from 2010 August to 2013 June. We apply the STEREO CME Analysis Tool (StereoCAT) to the SEP-associated CMEs to obtain 3D speeds and 3D angular widths. The separation angles are determined as the longitudinal angle between flaring regions and magnetic footpoints of the spacecraft, which are calculated by the assumption of Parker spiral field. The main results are as follows. 1) We find that the dependence of the SEP peak fluxes on CME 3D speed from multi-spacecraft is similar to that on 2D CME speed. 2) There is a positive correlation between SEP peak flux and 3D angular width from multi-spacecraft, which is much more evident than the relationship between SEP peak flux and 2D angular width. 3) There is a noticeable anti-correlation (r=-0.62) between SEP peak flux and separation angle. 4) The multiple regression method between SEP peak fluxes and CME parameters shows that the longitudinal separation angle is the most important parameter, and the CME 3D speed is secondary on SEP peak flux.

  • PDF