• Title/Summary/Keyword: Flux-locked loop

Search Result 24, Processing Time 0.022 seconds

YBCO step-edge junction dc SQUID magnetometers with multi-loop pickup coil fabricated on sapphire substrates (사파이어 기판을 사용한 병렬 검출코일 구조의 계단형 모서리 접합 SQUID 자력계)

  • 황태종;김인선;김동호;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.94-97
    • /
    • 2004
  • Step-edge Josephson junctions (SEJ) have been fabricated on sapphire substrates with in situ deposited films of CeO$_2$ buffer layer and YBa$_2$Cu$_3$O$_{7}$ films on the low angle steps. Direct coupled SQUID magnetometers with the SEJ were formed on 1 cm X 1 cm R-plane sapphire substrates. Typical 5-${\mu}{\textrm}{m}$-wide Josephson junctions have R$_{N}$ of 3 Ω and I$_{c}$ of 50 $mutextrm{A}$ at 77 K. The direct coupled SQUID magnetometers were designed to have pickup coils of 50-${\mu}{\textrm}{m}$-wide 16 parallel loops on the 1 cm X 1 cm substrates with outer dimension of 8.8 mm X 8.8 mm. The SEJ SQUID magnetometers exhibit relatively low 1/f noise even with dc bias control, and could be stably controlled by flux-locked loops in the magnetically disturbed environment. Field noise of the do SQUID was measured to be 200∼300 fT/Hz$^{1}$2/in the white noise region and about 2 pT/Hz$^{1}$2/ at 1 Hz when measured with dc bias method.hod.d.

  • PDF

The characteristics of DROS magnetometer and MCG measurement (DROS 자력계의 동작특성 및 심자도 측정)

  • Kang, C.S.;Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.;Park, Y.K.;Lee, S.G.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.164-168
    • /
    • 2007
  • We developed a SQUID magnetometer based on Double Relaxation Oscillation SQUID(DROS) for measuring magnetocardiography(MCG). Since DROS provides a 10 times larger flux-to-voltage transfer coefficient than the conventional DC-SQUID, simple flux-locked loop electronics could be used for SQUID operation. Especially, we adopted an external feedback to eliminate the magnetic coupling with adjacent channels. When the DROS magnetometer was operated inside a magnetically shielded room, average magnetic field noise was about 5 $fT/^{\surd}Hz$ at 100 Hz. Using the DROS magnetometer, we constructed a multichannel MCG system. The system consisted of 61 magnetometers are arranged in a hexagonal structure and measures a vertical magnetic-field component to the chest surface. The distance between adjacent channels is 26 mm and the magnetometers cover a circular area with a diameter of 208 mm. We recorded the MCG signals with this system and confirmed the magnetic field distribution and the myocardinal current distribution.

  • PDF

A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric Activity

  • Lee, Yong-Ho;Kim, Ki-Woong;Kim, Jin-Mok;Kwon, Hyuk-Chan;Yu, Kwon-Kyu;Kim, In-Seon;Park, Yong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.154-163
    • /
    • 2006
  • A 64-channel magnetocardiogram (MCG) system using low-noise superconducting quantum interference device (SQUID) planar gradiometers was developed for the measurements of cardiac magnetic fields generated by the heart electric activity. Owing to high flux-to-voltage transfers of double relaxation oscillation SQUID (DROS) sensors, the flux-locked loop electronics for SQUID operation could be made simpler than that of conventional DC SQUIDs, and the SQUID control was done automatically through a fiber-optic cable. The pickup coils are first-order planar gradiometers with a baseline of 4 em. The insert has 64 planar gradiometers as the sensing channels and were arranged to measure MCG field components tangential to the chest surface. When the 64-channel insert was in operation everyday, the average boil-off rate of the dewar was 3.6 Lid. The noise spectrum of the SQUID planar gradiometer system was about 5 fT$_{rms}$/$\checkmark$Hz at 100 Hz, operated inside a moderately shielded room. The MCG measurements were done at a sampling rate of 500 Hz or 1 kHz, and realtime display of MCG traces and heart rate were displayed. After the acquisition, magnetic field mapping and current mapping could be done. From the magnetic and current information, parameters for the diagnosis of myocardial ischemia were evaluated to be compared with other diagnostic methods.

PLL Control Method for Precise Speed Control of Slotless PM Brushless DC Motor Using 2 Hall-ICs (2 Hall-ICs를 이용한 Slotless PM Brushless DC Motor의 정밀속도제어를 위한 PLL 제어방식)

  • Yoon Y.H;Lee S.J;Kim Y.R;Won C.Y;Choe Y.Y
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.109-116
    • /
    • 2005
  • The high performance drives of the slotless Permanent Magnet Brushless DC(PM BLDC) motor can be achieved by the current control, where the currents flow according to the rotor position and the current phase is suitably controlled according to the operational condition. Rotor position information can be provided by Hall-IC or sensorless algorithm. So, the Hall-ICs are set up in this motor to detect the main flux from the rotor. Instead of using three Hall-ICs and encoder, this paper uses only two Hall-ICs for the permanent magnet rotor position and the speed feedback signals, and uses a micro-controller of 16-bit type (80C196KC). Also because of low resolution obtained by using Hall-IC even low-cost and simple structure, to improve the wide range of speed response characteristic more exactly, we propose the rotor position signal synthesizer using PLL circuit based on two Hall-ICs.