• Title/Summary/Keyword: Flux method

Search Result 2,888, Processing Time 0.042 seconds

The Distribution of ATPase and Porin in the Bovine Heart Mitochondrial Cristae (소(牛) 심근 미토콘드리아의 ATPase와 porin의 분포)

  • Kim, Tae-Keun;Min, Byoung-Hoon;Kim, Soo-Jin
    • Applied Microscopy
    • /
    • v.40 no.4
    • /
    • pp.261-266
    • /
    • 2010
  • ATP is the energy source synthesized at the electron transferase that consist of complex I, II, III, IV and V in mitochondrial cristae. The complex V functions as ATPase which composed of sub-complex $F_0$ and $F_1$. Porin or VDAC (voltagedependent anion-selective channel), is a family of small pore-forming proteins of the mitochondrial outer membrane, and play important roles in the regulated flux of anion, proton and metabolites between the cytosolic and mitochondrial compartments. The channel allows the diffusion of negatively charged solutes such as succinate, malate, and ATP in the fully open state, but of positively charged ions in subconducting state. In this study, in order to investigate the relationship of the function and localization between porin and ATPase we observed the distribution of porin and ATPase in the mitochondria of the bovine heart. Monoclonal antibodies against porin and ATPase ${\beta}$-subunit were used to detect porin and ATPase using light microscope with immunohistochemistry and immunofluorescence, and using electron microscope with immunogold-labeling. ATPase were stained in longitudinal section region in cardiac muscle, porin were stained in longitudinal section region in cardiac muscle. We viewed more specific pattern of localization and distribution of these proteins using immunofluorescence method. There were some region which were labeled with porin or ATPase respectively, and others which were labeled both proteins in cardiac muscle. The electron microscope results showed that immunogold labeled porin were labeled locally at mitochondrial outer membrane and ATPase were labeled evenly at mitochondrial cristae. But ATPase was not labeled at mitochondria cristae. These results confirmed the subcellular localizations of porin and ATPase in mitochondrial outer membrane and cristae. Also, we assumed that ATP synthesis always does not activation in all mitochondria exist in the bovine cardiac muscle.

Activation Analysis of Dual-purpose Metal Cask After the End of Design Lifetime for Decommission (설계수명 이후 해체를 위한 금속 겸용용기의 방사화 특성 평가)

  • Kim, Tae-Man;Ku, Ji-Young;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.343-356
    • /
    • 2016
  • The Korea Radioactive Waste Agency (KORAD) has developed a dual-purpose metal cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. The metal cask was designed in compliance with international and domestic technology standards, and safety was the most important consideration in developing the design. It was designed to maintain its integrity for 50 years in terms of major safety factors. The metal cask ensures the minimization of waste generated by maintenance activities during the storage period as well as the safe management of the waste. An activation evaluation of the main body, which includes internal and external components of metal casks whose design lifetime has expired, provides quantitative data on their radioactive inventory. The radioactive inventory of the main body and the components of the metal cask were calculated by applying the MCNP5 ORIGEN-2 evaluation system and by considering each component's chemical composition, neutron flux distribution, and reaction rate, as well as the duration of neutron irradiation during the storage period. The evaluation results revealed that 10 years after the end of the cask's design life, $^{60}Co$ had greater radioactivity than other nuclides among the metal materials. In the case of the neutron shield, nuclides that emit high-energy gamma rays such as $^{28}Al$ and $^{24}Na$ had greater radioactivity immediately after the design lifetime. However, their radioactivity level became negligible after six months due to their short half-life. The surface exposure dose rates of the canister and the main body of the metal cask from which the spent nuclear fuel had been removed with expiration of the design lifetime were determined to be at very low levels, and the radiation exposure doses to which radiation workers were subjected during the decommissioning process appeared to be at insignificant levels. The evaluations of this study strongly suggest that the nuclide inventory of a spent nuclear fuel metal cask can be utilized as basic data when decommissioning of a metal cask is planned, for example, for the development of a decommissioning plan, the determination of a decommissioning method, the estimation of radiation exposure to workers engaged in decommissioning operations, the management/reuse of radioactive wastes, etc.

Quality Control of Agro-meteorological Data Measured at Suwon Weather Station of Korea Meteorological Administration (기상청 수원기상대 농업기상 관측요소의 품질관리)

  • Oh, Gyu-Lim;Lee, Seung-Jae;Choi, Byoung-Choel;Kim, Joon;Kim, Kyu-Rang;Choi, Sung-Won;Lee, Byong-Lyol
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.1
    • /
    • pp.25-34
    • /
    • 2015
  • In this research, we applied a procedure of quality control (QC) to the agro-meteorological data measured at the Suwon weather station of Korea Meteorological Administration (KMA). The QC was conducted through six steps based on the KMA Real-time Quality control system for Meteorological Observation Data (RQMOD) and four steps based on the International Soil Moisture Network (ISMN) QC modules. In addition, we set up our own empirical method to remove erroneous data which could not be filtered by the RQMOD and ISMN methods. After all these QC procedures, a well-refined agro-meteorological dataset was complied at both air and soil temperatures. Our research suggests that soil moisture requires more detailed and reliable grounds to remove doubtful data, especially in winter with its abnormal variations. The raw data and the data after QC are now available at the NCAM website (http://ncam.kr/page/req/agri_weather.php).

Evaluation of Cleanness and Physical Properties of W/O Microemulsion (W/O Microemulsion 세정제의 물성 및 세정성 평가)

  • Lee, Myung Jin;Han, Ji Won;Lee, Ho Yeol;Han, Sang Won;Bae, Jae Heum;Park, Byeong Deog
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.769-777
    • /
    • 2002
  • Using four components - nonionic surfactants, water, hydrocarbon oil and an alcohol as cosurfactant, 12 types of cleaning agents were prepared, and their physical properties such as surface tension, viscosity, electroconductivity and phase stability were measured. As the formulated cleaning agents have low surface tensions(30.5-31.1 dyne/cm) and low viscosities (1.6-7.2 c.p.), they are satisfied with the general physical properties of water-in-oil(W/O) microemulsions for their industrial use. They showed a tendency that their temperature range for stable one-phase microemulsion decreased in accordance with the increase of alcohol/surfactant(A/S) ratio in the formulations. However, the temperature range of one-phase microemulsion was much more affected by hydrophilic lipophillic balance(HLB) value of the nonionic surfactant which increased its temperature range and it increased in accordance with the higher HLB value in the formulations. And the maximum content of water which can keep stable one-phase W/O microemulsion was measured at each sample. In addition, their temperature range for stable one-phase microemulsion was also measured. It was confirmed that the selection of surfactant type was very important for formulating a cleaning agent, since the W/O microemulsion system with the nonionic surfactant of the lower HLB value showed better cleaning efficacy that of the higher HLB value for abietic acid as a soil, which was used for preparing a rosin-type flux. In the formulated cleaning agents with the increase of A/S ratio in the formulations, however, there was no significant difference in cleaning efficacy. It was investigated that the differences of their cleaning efficacy was affected by the change of the condition of temperature and sonicating frequency as important factors in the industrial cleaning. That is, the higher, their cleaning temperature and the lower, their sonicating frequency, the more increased, their cleaning efficacy. Furthermore, using optical instruments like UV/Visable Spectrophotometer and FT-IR Spectrometer, their cleaning efficacy for abietic acid was measured. The removal of soil from the contaminated rinse water was measured by gravity separation method in the rinse bath. As a result, the cleaning agent system having the nonionic surfactant of HLB value 6.4 showed over 85% water-oil separation efficacy at over $25^{\circ}C$. Therefore, it was demonstrated in this work that the formulating cleaning agents were very effective for cleaning and economical in the possible introduction of water recycling system.

Control of Daily Integral PPE by the Artificial Lighting and shading screen In Greenhouse (인공광 및 차광스크린을 이용한 온실의 일일적산 광합성유효광량자속 조절)

  • 이현우
    • Journal of Bio-Environment Control
    • /
    • v.12 no.1
    • /
    • pp.45-53
    • /
    • 2003
  • The object of this study was to develop the control technology of daily integral photosynthetic photon flux (PPF) by the artificial lighting and shading screen in greenhouse. The shading time needed to get the target PPF by using two types of shading screens having shading ratio of 55% and 85% was analyzed. The results showed the shading ratio of screen to be installed in greenhouse should be different depending on the amount of target PPF to be controlled. The PPF control experiment by using the 55% shading screen in July and August showed that the maximum difference between measured and calculated value was about 5 mol$.$ $m^{-2}$ $.$ $d^{-1}$ in no shading condition. This difference is satisfactory result because the daily integral PPF is quite different depending on the weather condition. The simulation result about PPF distribution pattern shortened the time needed to find the proper arrangement of artificial lightings in greenhouse. But the further study was required to find the supplemental lighting arrangement to be able to provide the exactly uniform distribution of target light intensity. The supplemental irradiation time needed to acquire the target daily integral PPF for different supplemental light intensities, weather conditions, and months was analyzed. The result showed that the supplemental light intensity should be decided depending on the amount of target PPF to be controlled. The result of PPF control experiment conducted by using 55% shading screen and 300 $\mu$mol$.$ $m^{-2}$ $.$ $s^{-1}$ supplemental light intensity from the end of May to the beginning of June showed that the maximum difference between target and measured value was about 3 mol$.$ $d^{-1}$ $.$ $m^{-2}$ . If we consider that the difference of the daily integral PPF depending on weather condition was the maximum 30 mol$.$ $m^{-2}$ $.$ $d^{-l}$, the control effect was acceptable. Although the result of this study was the PPF control technology to grow lettuce, the data and control method obtained could be employed for other crop production.n.

The Effect of Cutting Positions and Temperature on the Rooting of Bitter Gourd (여주 삽목 시 삽수절단 위치와 온도조건이 발근에 미치는 영향)

  • Lee, Hee Ju;Lee, Sang Gyu;Kim, Sung Kyeom;Choi, Chang Sun;Kim, Sang Beom
    • Journal of Bio-Environment Control
    • /
    • v.25 no.3
    • /
    • pp.162-167
    • /
    • 2016
  • This study was carried out to investigate proper stem cutting position and air temperature to regenerate roots from cuttings of bitter gourd. 'NS454' (NS) and 'Dragon' (DR) cultivars were tested and the cutting position was cut at the 3rd node in the stem (treatment I) and cut at the central part (stem segment) between 3rd leaf and 4th leaf in the stem (treatment II). The air temperature was maintained at 18, 23, 28 and $35^{\circ}C$ in the growth chambers, respectively. The photosynthetic photon flux at the ground of a chamber was maintained in approximately $150-200{\mu}mol\;m^{-2}s^{-1}$ during the 16-hour photoperiod. The relative humidity in the chambers was maintained over 85%. After 10 days of cuttings, regardless of cutting position, DR and NS cultivars showed 100% the survival rate in the $18^{\circ}C$ or $23^{\circ}C$ treatments, however, most of plants $18^{\circ}C$ treatment had not rooting. In the $28^{\circ}C$ treatment, regardless of cutting position, DR and NS cultivars showed 100% of the rooting rate. In the $23^{\circ}C$ treatment, for DR cultivar, the node cutting showed 90% of rooting rate and the stem segment cutting showed 40% rooting rate. For NS cultivar, the node cutting showed 50% of rooting rate and the stem segment cutting showed 40% rooting rate. DR and NS cultivars have high rooting rate, while the rooting rate remarkably decreased in the $35^{\circ}C$ treatment. For DR cultivar, the stem segment cutting showed 5.3 of the highest rooting number and the node cutting showed 2.7 rooting number in the $28^{\circ}C$ treatment. NS cultivar was not significantly different the rooting regardless of cutting position. The results suggested that cutting at the stem segment cutting of bitter gourd is an effective cutting method for increasing survival rate and the air temperature should be maintained at $28^{\circ}C$.

Comparing Photosynthesis, Growth, and Yield of Paprika (Capsicum annuum L. 'Cupra') under Supplemental Sulfur Plasma and High-Pressure Sodium Lamps in Growth Chambers and Greenhouses (황 플라즈마 및 고압나트륨 램프의 보광에 따른 생육상 및 온실에서의 파프리카 광합성 및 생산성 비교)

  • Park, Kyoung Sub;Kwon, Dae Young;Lee, Joon Woo;Son, Jung Eek
    • Journal of Bio-Environment Control
    • /
    • v.27 no.4
    • /
    • pp.332-340
    • /
    • 2018
  • Supplemental lighting with artificial light sources is a practical method that enables normal growth and enhances the yield and quality of fruit vegetable in greenhouses. The objective of this study was to investigate the effect of sulfur plasma lamp (SP) and high-pressure sodium lamp (HPS) as supplemental lighting sources on the growth and yield of paprika. For investigating the effectiveness of SP and HPS lamps on paprika, the effects of primary lighting on plant growth were compared in growth chambers and those of supplemental lighting were also compared in greenhouses. In the growth chamber, plant height, leaf area, stem diameter, number of leaves, fresh weight, and dry weight were measured weekly at SP and HPS from 2 weeks after transplanting. In the greenhouse, no supplemental lighting (only sunlight) was considered as the control. The supplemental lights were turned on when outside radiation became below $100W{\cdot}m^{-2}$ from 07:00 to 21:00. From 3 weeks after supplemental lighting, the growth was measured weekly, while the number and weight of paprika fruits measured every two weeks. In the growth chamber, the growth of paprika at SP was better than at HPS due to the higher photosynthetic rate. In the greenhouse, the yield was higher under sunlight with either HPS or SP than sunlight only (control). No significant differences were observed in plant height, number of node, leaf length, and fresh and dry weights between SP and HPS. However, at harvest, the number of fruits rather than the weight of fruits were higher at SP due to the enhancement of fruiting numbers and photosynthesis. SP showed a light spectrum similar to sunlight, but higher PAR and photon flux sum of red and far-red wavelengths than HPS, which increased the photosynthesis and yield of paprika.

Comparison of Disk Tension Infiltrometer and van Genuchten-Mualem Model on Estimation of Unsaturated Hydraulic Conductivity (장력 침투계(Disk Tension Infiltrometer)와 van Genuchten-Mualem 모형 적용에 따른 불포화수리 전도도의 비교 해석)

  • Hur, Seung-Oh;Jung, Kang-Ho;Park, Chan-Won;Ha, Sang-Keun;Kim, Geong-Gyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.5
    • /
    • pp.259-267
    • /
    • 2006
  • Hydraulic conductivity is the rate of water flux on hydraulic gradient. The van Genuchten Mualem (VGM) model is frequently used for describing unsaturated state of soils, that is composed with the function of soil water potential and soil water content and requests various parameters. This study is to get the value of VGM parameters used Rosetta computer program based on neural network analysis method and to calculate VGM parameters. VGM parameters included Ko(effective saturated hydraulic conductivity), ${\theta}r$(residual soil water content), ${\theta}s$(saturated soil water content), L, n and m. The unsaturated hydraulic conductivity at 10 kPa was calculated by using Rosetta program. Unsaturated hydraulic conductivities of 17 soil series at 1, 3, 5, 7 kPa were also obtained by applying saturated hydraulic conductivity by disk tension infiltrometer based on Gardner and Wooding's equation. Water flow at the water potential of 3 kPa was very low except Namgye, Hagog, Baegsan, Sangju, Seogcheon, Yesan soil series. Unsaturated hydraulic conductivity at 1 kPa showed the highest value for Samgag soil series and was in order of Yesan, Hwabong, Hagog and Baegsan soil series. Those of Gacheon, Seocheon and Ugog soil series were very low. When the value by VGM was compared with the value by disc tension infiltrometer, there was a tendency with exponential function to soils without gravel but there was no tendency to soils including gravel. Conclusively, it would be limited that VGM model for unsaturated hydraulic conductivity analysis applies to Korean agricultural land including gravel and having steep slope, shallow soil depth.