• Title/Summary/Keyword: Flux Observer

Search Result 222, Processing Time 0.025 seconds

Sensorless Vector Control of Induction Motors Using a New Reduced-Order Extended Luenberger Observer (새로운 축소 차원 확장 루엔버거 관측기를 이용한 유도 전동기의 센서리스 벡터제어)

  • Lee, Kyo-Beum;Song, Joo-Ho;Song, Joong-Ho;Choy, Ick
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.3
    • /
    • pp.173-179
    • /
    • 2004
  • A synthesis method of the reduced-order extended Luenberger observer (ROELO) and its design procedure for a nonlinear dynamic system are presented. This paper proposes a method to reduce the order of the observer and to ! elect the observer gain matrix. The proposed algorithm is applied for high performance induction motor drives without a speed sensor The simulation and experiment results show that the proposed ROELO provides both rotor flux and rotor speed estimation with good performance.

Study on the analysis Adaptive Observers to Control SRM Control Meathod (SRM 제어방법들에 대한 적응관측기들의 분석)

  • Shin, Jae-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.160-164
    • /
    • 2007
  • MRAS observer, which is based on adaptive control theory, estimates speed and position by using optimal observer gains on the basis of Lyapunov stability theory. However, in case of MRAS theory, position estimation error is in existence because of non-linearity for inductance variation and limit cycles for position estimation. The adaptive sliding observer based on the variable structure control theory estimates the speed and position for zero of estimation error by using the sliding surface equal to the error between speed and position estimation. The binary observer estimates the rotor speed and rotor flux with alleviation of the high-frequency chattering, and retains the benefits achieved in the conventional sliding observer, such as robustness to parameter and disturbance variations. The speed and position sensorless control of SRM under the load and inductance variation is verified by the experimental results.

  • PDF

Sensorless IPMSM Drives based on Extended Nonlinear State Observer with Parameter Inaccuracy Compensation

  • Mao, Yongle;Liu, Guiying;Chen, Yangsheng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.289-297
    • /
    • 2014
  • This paper proposed a novel high performance sensorless control scheme for IPMSM based on an extended nonlinear state observer. The gain-matrix of the observer has been derived by using state linearization method. Steady state errors in estimated rotor position and speed due to parameter inaccuracy have been analyzed, and an equivalent flux error is defined to represent the overall effect of parameter errors contributing to the wrong convergence of the estimated rotor speed as well as rotor position. Then, an online compensation strategy was proposed to limit the estimation errors in rotor position and speed. The effectiveness of the extended nonlinear state observer is validated through simulation and experimental test.

Sliding Mode Cascade Observer for Sensorless Control of Induction Motor (유도 전동기의 센서없는 속도제어를 위한 슬라이딩 모드 축차 관측기)

  • Kim, Eung-Seok;Song, Joong-Ho;Oh, Sang-Rok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2057-2059
    • /
    • 2001
  • A nonlinear adaptive speed controller is designed for induction motors. Only the measurement of the stator current is used to design the controller and the observers. The sliding mode cascade observer is introduced to estimate the stator current and its time derivatives. The open-loop observer are designed to estimate the rotor flux and its time derivatives. The adaptive observer is also designed to estimate the rotor resistance. Sequentially, the rotor speed can be calculated using these estimated values. It is shown that the estimation errors of the corresponding states and the parameter converge to the specified residual set. It is also shown that the speed controller using these estimates is performed well. The experimental results are represented to investigate the validity of the proposed observer and controller.

  • PDF

Performance Evaluation of an Integrated Starter-Alternator with an IPM Synchronous Machine under Sensor-less Operation

  • Xu, Zhuang;Rahman, M.F.;Wang, G.;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.49-57
    • /
    • 2012
  • This paper presents performance evaluation of an Integrated Starter-Alternator (ISA) prototype with an Interior Permanent Magnet (IPM) synchronous machine under sensor-less operation. To attain a high starting torque at zero speed and in subsequent extremely low speed range, a hybrid signal injection method is proposed. At higher speed, an improved stator flux observer is used for the stator flux estimation. This observer is able to produce accurately-estimated stator flux linkage for high performance Direct Torque and Flux Control (DTFC) implementation. The sensor-less DTFC IPM synchronous machine drive takes full advantage of the capacity of the power converter and fulfills the control specifications for the ISA. The trajectory control algorithm responds rapidly and in a well behaved manner over a wide range of operating conditions. The experimental results verify the feasibility and advantages of the system.

A Study on Inductance compensation of Reluctance Synchronous Motor with Neural Network (신경망을 이용한 리럭턴스 동기전동기(Reluctance Synchronous Motor)의 인덕턴스 보상에 관한 연구)

  • Kim, Min-Huei;Kim, Nam-Hun;Baik, Won-Sik;Park, Hong-Il;Kim, Dong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.151-154
    • /
    • 2002
  • This paper presents an implementation of high-dynamic performance control system of Reluctance Synchronous Motor(RSM) drives for an industrial servo drive system with direct torque control(DTC). The estimation of the stator flux and torque are obtained by using flux observer which a saturated inductance Ld and Lq of d-q axises can be compensated by using the neural network from measuring the modulus and angle of the stator current space vector. To obtain fast torque response and maximum torque/current, the reference command flux is ensured by imposing Ids=Iqs. The control strategy is proposed to fast response and optimal efficiency for RSM drive. The developed digitally high-performance control system are shown a good response characteristic of control results and high performance features using 1.0kW RSM.

  • PDF

Input-Output Feedback Linearization of Sensorless IM Drives with Stator and Rotor Resistances Estimation

  • Hajian, Masood;Soltani, Jafar;Markadeh, Gholamreza Arab;Hosseinnia, Saeed
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.654-666
    • /
    • 2009
  • Direct torque control (DTC) of induction machines (IM) is a well-known strategy of these drives control which has a fast dynamic and a good tracking response. In this paper a nonlinear DTC of speed sensorless IM drives is presented which is based on input-output feedback linearization control theory. The IM model includes iron losses using a speed dependent shunt resistance which is determined through some effective experiments. A stator flux vector is estimated through a simple integrator based on stator voltage equations in the stationary frame. A novel method is introduced for DC offset compensation which is a major problem of AC machines, especially at low speeds. Rotor speed is also determined using a rotor flux sliding-mode (SM) observer which is capable of rotor flux space vector and rotor speed simultaneous estimation. In addition, stator and rotor resistances are estimated using a simple but effective recursive least squares (RLS) method combined with the so-called SM observer. The proposed control idea is experimentally implemented in real time using a FPGA board synchronized with a personal computer (PC). Simulation and experimental results are presented to show the capability and validity of the proposed control method.

A High-Performance Position Sensorless Control System of Reluctance Synchronous Motor with Direct Torque Control (직접토크제어에 의한 위치검출기 없는 리럭턴스 동기전동기의 고성능 제어시스템)

  • 김민회;김남훈;백원식
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.81-90
    • /
    • 2002
  • This paper presents an Implementation of digital high-performance position sensorless control system of Reluctance Synchronous Motor(RSM) drives with Direct Torque Control(DTC). The system consists of stator flux observer, speed and torque estimator, two digital hysteresis controllers, an optimal switching look-up table, Insulated Gate Bipolar Transistor(IGBT) voltage source inverter, and TMS320C31 DSP board. The stator flux observer Is based on the combined voltage and current model with stator flux feedback adaptive control of which inputs are current and voltage sensed on motor terminal for wide speed range. In order to prove the suggested sensorless control algorithm for industrial field application, we have some simulation and actual experiment at low and high speed range. The developed high-performance speed control by fully digital system are shown a good response characteristic of control results and high performance features using 1.0[kW] RSM having 2.57 reluctance ratio of $L_d/L_q$.

Speed Sensorless Stator Flux-Oriented Control of Induction Motor In the Field Weakening Region Using Luenberger Observer (약계자영역에서 루엔버기관측기를 이용한 유도전동기의 속도 센서리스 고정자자속 기준제어)

  • 권태성;신명호;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.375-380
    • /
    • 2003
  • In a conventional speed sensorless stator flux-oriented (SFO) induction motor drive, when the estimated speed is transformed into the sample-data model using the first-forward difference approximation, the sampled data model has a modeling error which, in turn, produces an error in the rotor speed estimation. The error is removed by the use of a low pass filter (LPF). As a result, the delay of the estimated speed occurs in transients by the use of the LPF. This paper proposes a method to estimate exactly the speed by using Luenberger observer to solve the problem of a conventional method.

Scheme of Vector Drive System for Induction Motor without Speed Sensor (유도전동기 센서리스 벡터구동 시스템의 구현)

  • 손의식;홍순일
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.68-73
    • /
    • 2003
  • This paper describes a newly developed vector drive system without the speed sensor using theory of a flus observer and based on the field oriented vector control. The new method of speed estimation is presented to operate with the position and magnitude of the secondary flux vector which obtain to the observer md detected current. As the speed of estimation is determined to the flux and the motor constants, this method don't need to adjust the gain of the parameter and is operated simply. On basic the derived theory for vector control, sensorless speed control system for induction motor drive is design and realized. It is determined a controllers gain and observer gain by simulation and the experiment of sensorless vector drive is realized.