• 제목/요약/키워드: Flux Leakage

검색결과 310건 처리시간 0.029초

Flat Transformer 코아의 설계와 컨버터 동작 특성 (Study on designing of Flat Transformer and operating characteristics of Converter)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.587-590
    • /
    • 2003
  • The first attention in designing a transformer for low temperature rise should be to reduce losses. Leakage inductance and temperature rise are two of the more impotent problems facing the magnetic core technology of today's high frequency transformers. Excessive leakage inductance increases the stress on the switching transistors and limits the duty-cycle, and excessive temperature rise can lead the design limitation of high frequency transformer with high current. The flat transformer technology provides a very good solution to the problems of leakage inductance and thermal management for high frequency power. The critical magnetic components and windings are optimized and packaged within a completely assembled module. The turns ratio in a flat transformer is determined as the product of the number of elements or modules times the number of primary turns. The leakage inductance increase proportionately to the number of elements, but since it is reduced as the square of the turns, the net reduction can be very significant. The flat transformer modules use cores which have no gap. This eliminates fringing fluxes and stray flux outside of the core. The secondary windings are formed of flat metal and are bonded to the inside surface of the core. The secondary winding thus surrounds the primary winding, so nearly all of the flux is captured.

  • PDF

공중욕조에서의 FLUX3D에 의한 전위분포 해석 및 인체의 전격위험성 평가 (Electric Shock Risk Assessment of the Human Body and Potential Distribution Analysis by FLUX3D in a Public Bathtub)

  • 김두현;김성철;이종호;김한상;김종민
    • 한국안전학회지
    • /
    • 제22권2호
    • /
    • pp.41-46
    • /
    • 2007
  • This paper considers the electrical shock risk of the human body due to underwater leakage current in such places of public baths. Many submerged electric facilities in a public bath may create a severe electric shock hazard for the human body, since wet body in an accidentally energized bathtub can result in low electrical resistance through the human body for leakage or fault currents. Therefore a major consideration, in the context of electrical safety underwater, is the shock risk to the bather as a result of electric current flowing through the water in bathtub. To assess the electric shock risk and to analyze the potential distribution in a bathtub, 2 different situation cases are set up, then experimental and simulation methods are adopted. The validity of 2 cases of simulation and experiment data in a bathtub for electric distribution underwater are compared and analyzed. Also electric shock risk assessment underwater in a real public bathtub by simulation program package, Flux 3D, was conducted herein, and the results are presented and discussed.

MFL 비파괴 검사 시스템에서 다중 결함에 의한 신호 왜곡과 신호 보정에 관한 연구 (A Study on the Signal Correction for Multiple Defects in MFL Type Nondestructive Testing System)

  • 박정훈;김희민;박관수
    • 한국자기학회지
    • /
    • 제26권1호
    • /
    • pp.24-30
    • /
    • 2016
  • 지하에 매설된 가스배관에 발생한 결함 유무를 판별하는 방법으로는 자기누설 신호를 탐지하는 비파괴검사 기법이 사용되어져 왔다. 지하 매설된 배관은 높은 가스 운용압력과 습기와 같은 외부환경에 노출되어 있어 금속부식과 같은 결함들이 군집하여 발생한다. 군집 결함들에 의해 발생한 자기누설 신호는 단일결함 신호와 비교하여 왜곡된 형태를 가지며, 왜곡된 결함 신호의 분포는 최종적으로 결함의 형상 추정을 어렵게 한다. 본 논문에서는 30인치 직경의 배관을 기준으로 다중 결함의 배치 형태와 거리를 달리하며 신호 패턴을 분석하고, 인접한 결함의 분리 가능 여부와 신호 보정을 고려한 개선된 결함 판정 알고리즘을 제안하였다.

자기장학 누설자속법을 응용한 직류전류계측법에 관한 연구 (A Study on Direct Current Measurement Using Magneto-Optical LMF Method)

  • 이진이
    • 비파괴검사학회지
    • /
    • 제24권6호
    • /
    • pp.566-572
    • /
    • 2004
  • 금속성 도선 뿐 아니라 기상 또는 액상의 직류전류를 계측하기 위해서는 비접촉으로 전류를 측정할 필요가 있다. 본 논문은 직류전류를 비접촉으로 계측하기 위한 방법 중 하나로써 패러데이효과와 누설자속을 이용하는 방법을 제안하고, 이론적 고찰 및 실험적 검증결과를 보고한다. 공극을 가진 강자성체 코어를 1차 코일에 의하여 자화하면, 공극 주위에는 누설자속이 발생한다. 이러한 누설자속의 수직성분에 의하여 자기광학소자의 자구는 자화되어, 공극의 중심과 자벽은 평행하게 된다. 한편, 2차 코일에 의하여 자기광학소자에 수직한 방향으로 자장을 인가하면, 누설자속분포는 공극의 중심을 기준으로 좌우 대칭이었던 자구의 분포에 편향이 발생한다. 이때 금속, 기체 또는 액체상태의 전류가 코어를 통과하면 자기광학소자의 자벽이 이동하게 된다. 이러한 원리에 의하여 자구 또는 자벽의 이동량을 측정하면, 코어를 통과하는 직류전류의 세기를 알 수 있다.

전향 축류형 홴에서의 익단 누설 유동 구조 (Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan)

  • 이공희;명환주;백제현
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.883-892
    • /
    • 2003
  • The experiment using three-dimensional laser Dopperr velocimetery (LDV) measurements and the computation using the Reynolds stress model of the commercial code, FLUENT, were conducted to give a clear understanding on the structure of tip leakage flow in a forward-swept axial-flow fan operating at the maximum efficiency condition. The tip leakage vortex was generated near the position of the minimum wall static pressure, which was located at approximately 12% chord downstream from the leading edge of blade suction side, and developed along the centerline of the pressure trough within the blade passages. A reverse flow between the blade tip region and the casing, induced by tip leakage vortex, acted as a blockage on the through-flow. As a result, high momentum flux was observed below the tip leakage vortex. As the tip leakage vortex proceeded to the aft part of the blade passage, the strength of tip leakage vortex decreased due to the strong interaction with the through-flow and casing boundary layer, and the diffusion of tip leakage vortex caused by high turbulence. In comparison with LDV measurement data, the computed results predicted the complex viscous flow patterns inside the tip region, including the locus of tip leakage vortex center, in a reliable level.

Operation Principle and Topology Structures of Axial Flux-Switching Hybrid Excitation Synchronous Machine

  • Liu, Xiping;Wang, Chen;Zheng, Aihua
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.312-319
    • /
    • 2012
  • The operation principle of an axial flux-switching hybrid excitation synchronous machine (AFHESM) is analyzed and its topology structures are proposed in this paper. After some comprehensive analysis of the operation principle to axial flux electrical machine, flux-switching electrical machine and hybrid excitation electrical machine, the operation principle of AFHESM is given. Combined with some typical topological structures of hybrid excitation electrical machine, some possible topological structures are proposed and some comprehensive comparisons are carried out. The analysis results show that the stator-separated AFHESM has some advantages such as less AM turns, less impact on the demagnetization of PM, less magnetic flux-leakage and higher efficiency compared to other topologies.

다채널 자속누설 센서를 이용한 강케이블의 국부 단면손상 검색 (Local Fault Detection Technique for Steel Cable using Multi-Channel Magnetic Flux Leakage Sensor)

  • 박승희;김주원;이창길;이종재;길흥배
    • 한국전산구조공학회논문집
    • /
    • 제25권4호
    • /
    • pp.287-292
    • /
    • 2012
  • 본 연구에서는 다채널 자속누설 센서를 이용하여 강케이블의 국부손상을 검색하였다. 먼저 자속누설 기법을 고정된 케이블 구조물에 적용하기 위해 프로토타입의 8채널 자속누설 센서헤드를 제작하였고, 국부손상이 발생한 케이블을 구현하기 위하여 PVC 파이프에 강케이블을 채워 강케이블 다발 시편을 제작하였고, 케이블 시편 외부 및 내부에 다양한 크기 및 방향을 가지는 국부손상을 단계적으로 발생시켰다. 이와 같이 제작된 강케이블 시편을 대상으로 각 손상단계에서 자속누설 센서헤드를 이용하여 자속신호를 스캔하고 출력전압으로 표현하였다. 이어서 일반극치분포를 이용해 손상유무를 판단할 수 있는 기준이 되어줄 임계값을 설정하였고, 이를 각 채널에서 계측된 자속신호와 비교하여 객관적인 손상판단을 수행하였다. 또한 케이블 모니터링에 있어 가장 중요한 정보인 손상의 길이방향 위치를 효과적으로 검색하기 위해 모든 채널의 자속값을 합하여 총합값의 형태로 임계값과 함께 나타내었다. 최종적으로 임계값을 초과한 부분의 길이방향 및 원주방향 위치를 실제 손상과 비교함으로써 본 기법의 국부손상 검색 가능성을 살펴보았다.

FLUX3D를 이용한 자기부상용 전자석의 특성 해석 (Characteristic Analysis of a Magnet for Magnetically Levitated Vehicle using FLUX3D)

  • 이재건;신판석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.127-129
    • /
    • 1996
  • A 3-dimensional analysis is desired for a magnet of magnetically levitated vehicle because the geometrical shape of the magnet is complicated and nonsymmetric. A FEM package of FLUX3D is used to analyze the characteristic of the magnet. Various quantities could be observed like levitation force, flux density distribution along the air gap, edge and fringing effect, leakage flux pattern, etc. The simulation results from FLUX3D are compared with those of 2-D analysis and test results. There are a little difference between results due to the boundary conditions and magnetized B-H curve of the core.

  • PDF

3차원 자계분포해석을 이용한 고온초전도동기모터에서의 Ag/Bi-2223 Tape 및 Flux Damper의 특성해석 (The Characteristic Analysis of the Ag/Bi-2223 Tape and the Flux damper in GTS Synchronous Motor through 3-Dimensional Magnetic Field Analysis Using F.E.M)

  • 송명곤;윤용수;이상진;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.170-172
    • /
    • 2000
  • This paper deals with the characteristic analysis of the flux damper with respect to the load, and the stability of Ag/Bi-2223 tapes in a high-Tc superconducting (HTS) synchronous motor. To find out the magnetic field distribution in a detailed model of the actual motor, the experimentally measured currents of the armature and the field windings are used as input parameters. The simulation results show that the flux damper shields the time varying field up to 10%, reduces armature reactance during the motor operation and during load changes, improving the stable motor operation. And it was observed that the flux damper generates loss by means of leakage flux, but this is not significant and it doesn't degrade the performance of the TS synchronous motor.

  • PDF