• Title/Summary/Keyword: Flux Leakage

Search Result 310, Processing Time 0.028 seconds

Cogging Force Verification of the Back-yoke Length of a Moving-coil-type Slotless Linear Synchronous Motor

  • Kim, Yong-Jae;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.14 no.1
    • /
    • pp.47-51
    • /
    • 2009
  • The coreless linear synchronous motor (coreless LSM) has been widely used as a driving source of semiconductor production processes for machine speeding up, positioning accuracy and simple maintenance. However, this coreless LSM suffers the disadvantage of decreased thrust force created by the leakage of magnetic flux. With the goal of increasing the generated thrust force and decreasing the cogging force, the slot of the core part was removed and a moving-coil-type slotless LSM (moving-coil-type slotless LSM) is proposed in this paper. Although this moving-coil-type slotless LSM with a back-yoke at the primary side demonstrated an increase in the generated thrust force, it remained capable of generating the cogging force when the primary side was moved due to the position between the permanent magnet and the back-yoke. Therefore, we attempted to decrease the cogging force of the moving-coil-type slotless LSM. We found that the back-yoke length at the primary side needs to be made $0.5{\tau}$ longer than the integral multiple of the magnetic pole pitch in order to decrease the cogging force created by the moving-coil-type slotless LSM.

Development of a Diagnostic Algorithm with Acoustic Emission Sensors and Neural networks for Check Valves

  • Seong, Seung-Hwan;Kim, Jung-Soo;Hur, Seop;Kim, Jung-Tak;Park, Won-Man
    • Nuclear Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.540-548
    • /
    • 2004
  • Check valve failure is one of the worst problems in nuclear power plants. Recently, many researches have been based on new technology using accelerometers and ultrasonic and magnetic flux detection have been carried out. Here, we have suggested a method that uses acoustic emission sensors for detecting the failures of check valves through measuring and analyzing backward leakage flow, a system that works without disassembling the check valve. For validating the suggested acoustic emission sensor methodology, we designed a hydraulic test loop with a check valve. We have assumed in this study that check valve failure is caused by disk wear or by the insertion of a foreign object. In addition, we have developed diagnostic algorithms by using a neural network model to identify the type and size of the failure in the check valve. Our results show that the proposed diagnostic algorithm with acoustic emission sensors is a good solution for identifying check valve failure without necessitating any disassembly work.

MEMS-based Micro Fluxgate Sensor Using Solenoid Excitation and Pick-up Coils (MEMS 공정 제작방법에 의한 솔레노이드형 여자 코일과 검출코일을 사용한 마이크로 플럭스게이트 센서)

  • 나경원;박해석;심동식;최원열;황준식;최상언
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.2
    • /
    • pp.120-124
    • /
    • 2003
  • This paper describes a MEMS-based micro-fluxgate magnetic sensing element using Ni$\_$0.8/Fe$\_$0.2/ film formed by electroplating. The micro-fluxgate magnetic sensor composed of a thin film magnetic core and micro-structure solenoids for the pick-up and the excitation coils, is developed by using MEMS technologies in order to take advantage of low-cost, small size and lower power consumption in the fabrication. A copper with 20${\mu}$m width and 3${\mu}$m thickness is electroplated on Cr (300${\AA}$) / Au (1500${\AA}$) films for the pick-up (42turn) and the excitation (24turn) coils. In order to improve the sensitivity of the sensing element, we designed the magnetic core into a rectangular-ring shape to reduce the magnetic flux leakage. An electroplated permalloy film with the thickness of 3${\mu}$m is obtained under 2000 gauss to induce magnetic anisotropy. The magnetic core has the high DC effective permeability of ~1,100 and coercive field of ~0.1 Oe. The fabricated sensing element using rectangular-ring shaped magnetic film has the sensitivity of about 150 V/T at the excitation frequency of 2 MHz and the excitation voltage of 4.4 V$\_$p p/. The power consumption is estimated to be 50mW.

New ZVZCT Bidirectional DC-DC Converter Using Coupled Inductors

  • Qian, Wei;Zhang, Xi;Li, Zhe;Jin, Wenqiang;Wiedemann, Jochen
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.11-23
    • /
    • 2019
  • In this study, a novel zero voltage zero current transition (ZVZCT) bidirectional DC-DC converter is proposed by employing coupled inductors. This converter can turn the main switch on at ZVZCT and it can turn it off with zero voltage switching (ZVS) for both the boost and buck modes. These characteristics are obtained by using a simple auxiliary sub-circuit regardless of the power flow direction. In the boost mode, the auxiliary switch achieves zero current switching (ZCS) turn-on and ZVS turn off. Due to the coupling inductors, this converter can make further efficiency improvements because the resonant energy in the capacitor or inductor can be transferred to the load. The main diode operates with ZVT turn-on and ZCS turn-off in the boost mode. For the buck mode, there is a releasing circuit to conduct the currents generated by the magnetic flux leakage to the output. The auxiliary switch turns on with ZCS and it turns off with ZVT. The main diode also turns on with ZVT and turns off with ZCS. The design method and operation principles of the converter are discussed. A 500 W experimental prototype has been built and verified by experimental results.

Recovery of Nitric Acid from Waste Solder Stripper by Diffusion Dialysis (폐솔더 박리액으로부터 확산투석법에 의한 질산의 회수)

  • Ryu, Seong-Hyung;Kim, Tae-Young;Ahn, Nak-Kyoon;Gang, Myeong-Sik;Ahn, Jae-Woo;Ahn, Jong-Gwan
    • Resources Recycling
    • /
    • v.24 no.5
    • /
    • pp.33-39
    • /
    • 2015
  • A basic study was conducted to effectively recover nitric acid from a waste solder stripper by diffusion dialysis using anion exchange membranes. The effects of flow rate, flux ratio, nitrate concentration, and metallic ion types and concentration on the recovery percentage of nitric acid were investigated. The recovery percentage of nitric acid was decreased with the increase of flow velocity. But the recovery percentage of nitric acid was increased as the increase of flux ratio(W/F) and showing a recovery percentage of nitric acid of about 99% at a flux ratio of 1.5 or more. As the increase of nitric acid concentration in feed solution, the recovery percentage of nitric acid was increased up to 3.0M, but in case of greater than 3.0M, the recovery percentage gradually was decreased. Leakage percentage of metallic ions through the membrane were in the order of Pb, Na and Cu but Fe and Sn did not leakaged. As a result of diffusion dialysis using real waste solder stripper at a flow rate of $0.9L/hr-m^2$, W/F = 1.3, a recovery percentage of nitric acid of approximately 94% was gained.

The Characteristics for BNCT facility in Hanaro Reactor

  • Soheigh Suh;Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Yoo, Seong-Yul;Rhee, Chang-Hun;Rhee, Soo-Yong;Jun, Byung-Jin
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.161-163
    • /
    • 2002
  • The BNCT(Boron Neutron Capture Therapy) facility has been developed in Hanaro(High-flux Advanced Neutron Application Reactor), a research reactor of Korea Atomic Energy Research Institute. A typical tangenial beam port is utilized with this BNCT facility. Thermal neutrons can be penetrated within the limits of the possible maximum instead of being filtered fast neutrons and gamma rays as much as possible using the silicon and bismuth single crystals. In addition to, the liquid nitrogen (LN$_2$) is used to cool down the silicon and bismuth single crystals for the increase of the penetrated thermal neutron flux. Neutron beams for BNCT are shielded using the water shutter. The water shutter was designed and manufactured not to interfere with any other subsystem of Hanaro when the BNCT facility is operated. Also, it is replaced with conventional beam port plug in order to cut off helium gas leakage in the beam port. A circular collimator, composed of $\^$6/Li$_2$CO$_3$ and polyethylene compounds, is installed at the irradiation position. The measured neutron flux with 24 MW reactor power using the Au-198 activation analysis method is 8.3${\times}$10$\^$8/ n/cm$^2$ s at the collimator, exit point of neutron beams. Flatness of neutron beams is proven to ${\pm}$ 6.8% at 97 mm collimator. According to the result of acceptance tests of the water shutter, the filling time of water is about 190 seconds and drainage time of it is about 270 seconds. The radiation leakages in the irradiation room are analyzed to near the background level for neutron and 12 mSv/hr in the maximum for gamma by using BF$_3$ proportional counter and GM counter respectively. Therefore, it is verified that the neutron beams from BNCT facility in Hanaro will be enough to utilize for the purpose of clinical and pre-clinical experiment.

  • PDF

Effects of Residual Magnetization on MEL Non-destructive Inspection of Gas Pipeline (가스관의 자속누설탐사에서 잔류자화의 영향에 관한 연구)

  • Jang, Pyung-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.4
    • /
    • pp.143-148
    • /
    • 2004
  • Effects of residual flux density M$_{res}$ and number of inspection on the detection voltage and flux density B of the gas pipeline were investigated in MFL inspection, which is widely used for the non-destructive inspection in a gas pipeline. A simulation equipment composed of the magnetizer and iron ring attached on an aluminum disc was constructed instead of a huge gas pipeline facility. With this system. the iron ring could be perfectly demagnetized and signals from the bolt screw stuck on the disc could be clearly detected so that the effects of M$_{res}$S and the inspection number on the detection voltage and B of iron ring were effectively investigated. With increasing the number of inspection, M$_{res}$, B of the iron ring and the detection voltage decreased and then kept at constant values while final M$_{res}$ increased with increasing initial M$_{res}$. If inspection condition were kept unchanged, the detection voltage was proportional to the last M$_{res}$ of the iron ring instead of B. This was probably due to magnetic hysteresis of the iron ring inherited from magnetic domain so that consideration on the magnetic hysteresis was inevitable in the analysis of MFL signal from defects of a gas pipeline. A new inspection scheme using the magnetizer with reversed magnetization in the subsequent inspection was proposed from the result that a high detection voltage could be obtained in the first inspection of gas pipeline with positive M$_{res}$.

A Study on Development of Alternative Non-aqueous Cleaning Agents to Ozone Depletion Substances and its Field Application (오존파괴물질 대체 비수계세정제 개발 및 현장 적용 연구)

  • Park, Yong-Bae;Bae, Jae-Heum;Lee, Min-Jae;Lee, Jong-Gi;Lee, Ho-Yeoul;Bae, Soo-Jung;Lee, Dong-Kee
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.306-313
    • /
    • 2011
  • Flux or solder is used in soldering process for manufacturing electronic parts such as printed circuit boards (PCB). After soldering process, residual flux and solder paste on the parts should be removed since their residuals could cause performance degradation or failure of parts due to their corrosion and electric leakage. Ozone depletion substances such as 1,1,1- trichloroethane (TCE) and HCFC-141b have widely been using for removal of residual flux and solder paste after soldering process In manufacturing of electronic parts until now. In this study, non-aqueous cleaning agents without flash point were developed and applied to industrial field for replacement of cleaning agents with ozone depletion. In order to develop non-aqueous cleaning agents without ethers, esters, fluoride- type solvents. And their physical properties and cleaning abilities were evaluated, and they were applied to industrial fields for cleaning of flux and solder on the PCB. And vacuum distillation apparatus were operated to determine their operating conditions and recycling yields for recycling of used cleaning agents formulated in this study. As a result of physical properties measurement of our formulated cleaning agents, they were expected to have good wetting and penetrating power since their surface tensions were relatively low as 18.0~20.4 dyne/$cm^2$ and their wetting indices are relatively large. And some cleaning agents holding fluoride-type solvents as their components did not have any flash point and they seemed to be safe in their handling and storage. The cleaning experimental results showed that some cleaning agents were better in their cleaning of flux and solder paste than 1,1,1-TCE and HCFC-141b. And industrial application results of the formulated cleaning agents for cleaning PCB indicated that they can be applicable to industry due to their good cleaning capability in comparison with HCFC-141b. The recycling experiments of the used formulated cleaning agents through a vacuum distillation apparatus also showed that their 91.9~97.5% could be recycled with its proper operating conditions.

Effects of Artificial CO2 Release in Soil on Chlorophyll Content and Growth of Pinus densiflora and Quercus variabilis Seedlings (토양 내 인위적인 이산화탄소 누출에 따른 소나무와 굴참나무 묘목의 엽록소 함량과 생장 반응)

  • Kim, Hyun-Jun;Han, Seung Hyun;Kim, Seongjun;Chang, Hanna;Son, Yowhan
    • Journal of Korean Society of Forest Science
    • /
    • v.107 no.4
    • /
    • pp.351-360
    • /
    • 2018
  • This study was conducted to analyze the responses of chlorophyll contents and growth of Pinus densiflora and Quercus variabilis seedlings on distance from the well and $CO_2$ flux after the artificial $CO_2$ release. From June 1 to 30, 2016, $CO_2$ gas was injected at the rate of $6L\;min^{-1}$ at the study site in Eumseong. Chlorophyll content was analyzed in the middle of July, 2016, and root collar diameter (RCD), height (H), and biomass were measured in May and December, 2016 after planting 2-year-old P. densiflora and 1-year-old Q. variabilis seedlings in May, 2015. The chlorophyll content of P. densiflora seedlings did not show a significant correlation with $CO_2$ flux, whereas the chlorophyll content of Q. variabilis seedlings showed a significant negative correlation with increasing $CO_2$ flux (P<0.05). The RCD and H growth rates of both species showed the significant difference in the distance from the well of the $CO_2$ anthropogenic release treatment. In particular, the RCD and H growth rate of P. densiflora seedlings and the RCD growth rate of Q. variabilis seedlings increased significantly as the seedlings were closer to the well, but the H growth rate of Q. variabilis seedlings decreased significantly. In addition, as the $CO_2$ concentration in the ground increases, ${\Delta}R/S$ ratio increases in both species, suggesting that the high $CO_2$ concentration in the soil promotes carbon distribution relative to the root part. The results of this study can be used as data necessary to monitor the $CO_2$ leakage and physiological and growth responses of both species to leakage of stored $CO_2$ in the future.

A Study of the Exclusive Embedded A/D Converter Using the Microprocessor and the Noise Decrease for the Magnetic Camera (마이크로프로세서를 이용한 자기카메라 전용 임베디드형 AD 변환기 및 잡음 감소에 관한 연구)

  • Lee, Jin-Yi;Hwang, Ji-Seong;Song, Ha-Ryong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.99-107
    • /
    • 2006
  • Magnetic nondestructive testing is very useful far detecting a crack on the surface or near of the surface of the ferromagnetic materials. The distribution of the magnetic flux leakage (DMFL) on a specimen has to be obtained quantitatively to evaluate the crack. The magnetic camera is proposed to obtain the DMFL at the large lift-off. The magnetic camera consists of a magnetic source, magnetic lens, analog to digital converters (ADCs), interface, and computer. The magnetic leakage fields or the distorted magnetic fields from the object, which are concentrated on the magnetic lens, are converted to analog electrical signals tv arrayed small magnetic sensors. These analog signals are converted to digital signals by the ADCs, and are stored, imaged, and processed by the interface and computer. However the magnetic camera has limitations with respect to converting and switching speed, full range and resolution, direct memory access (DMA), temporary storage speed and volume because common ADCs were used. Improved techniques, such as those that introduce the operational amplifier (OP-Amp), amplify the signal, reduce the connection line, and use the low pass filter (LPF) to increase the signal to noise ratio are necessary. This paper proposes the exclusive embedded ADC including OP-Amp, LPF, microprocessor and DMA circuit for the magnetic camera to satisfy the conditions mentioned above.