• 제목/요약/키워드: Flux Chamber

검색결과 257건 처리시간 0.027초

플럭스 코어드 아크 용접 중 발생하는 총 크롬 및 6가 크롬의 함량 변화 (Content Variation of Total Chromium and Hexavalent Chromium in Flux Cored Arc Welding)

  • 윤충식;백남원;김정한;박동욱;하권철;최상준;김신범;채현병
    • 한국산업보건학회지
    • /
    • 제10권1호
    • /
    • pp.32-44
    • /
    • 2000
  • The practice of welding stainless steel is known to produce various valance states of chromium. $CO_2$ flux cored arc welding on stainless was performed in fume collection chamber. Content of total chromium and hexavalent chromium in fumes, content of hexavalent chromium in total chromium, solubility of hexavalent chromium were investigated. Content of total chromium in fumes increases from 2~3% to 7~9% as a function of input energy, but hexavalent chromium, less than 1.2% in fumes, is not related to input energy. Hexavalent chromium in fumes exists as solubles up to 90%. Content of total chromium in flux cored arc welding fumes and solubility of hexavalent chromium are similar to shielded metal arc welding fumes, but content of hexavalent chromium is similar to metal inert gas welding fumes. These characteristics are relevant to flux of wires and $CO_2$ shielding gas.

  • PDF

노즐 후방부의 Radiative Heat Flux 측정 (Measurement of Radiative Heat Flux of Nozzle Exit)

  • 안원근;박희호;황수권;김유
    • 한국항공우주학회지
    • /
    • 제31권5호
    • /
    • pp.87-92
    • /
    • 2003
  • 일반적으로 연소과정에서 발생한 고온고압의 연소가스로 인하여 액체추진기관의 연소실 및 노즐 벽면 그리고 추진기관 후방부위에 대류열전달과 복사열전달이 발생하는 것으로 알려져 있으며, 액체추진기관에서 발생하는 복사열전달 현상은 재생냉각장치의 열입력랑 예측 및 발사체의 추진기관 후방부위에 탑재되는 전자장비 및 구조물의 열적 환경을 분석하는데 매우 중요하다. 이에 본 연구에서는 노즐 후방부위에서 발생하는 복사열전달량을 측정하고 연소압과 혼합비에 따른 영향을 파악하였다. 동알한 형상의 소형 액체추진기관에서 연소압(200, 300, 400 psi)과 혼합비(1.5, 2.0, 2.5)에 따른 복사열전달의 특성을 파악하기 위하여 각각 3가지 조건에 대하여 연소시험을 수행하여 복사열전달량을 측정하였다. 시험 결과로부터 연소가스에서 발생하는 복사열전달의 상대적인 크기 및 미치는 인자들을 파악할 수 있었다. 본 연구를 통하여 석영을 활용하여 복사하는 복사열전달의 크기 및 현상을 파악할 수 있었다. 또한, 연소실 및 노즐에서 발생하는 복사열전달 현상을 파악할 수 있었다

급확대관내에서 류유선회유동의 열전달에 관한 연구 (An Experimental Study of the Turbulent Swirling Flow and Heat Transfer Downstream of an Abrupt Expansion in a Circulat Pipe with Uniform Heat Flux)

  • 권기린;허종철
    • 한국해양공학회지
    • /
    • 제10권3호
    • /
    • pp.138-152
    • /
    • 1996
  • Many studies of heat transfer on the swirling flow or unswirled flow in a abrupt pipe expansion are widely carried out. The mechanism is not fully found evidently due to the instabilities of flow in a sudden change of the shape and appearance of turbulent shear layers in a recirculation region and secondary vortex near the corner. The purpose of this study is to obtain data through an experimental study of the swirling flow and heat transfer downstream of an abrupt expansion in a circular pipe with uniform heat flux. Experiments were carried out for the turbulent flow nd heat transfer downstream of an abrupt circular pipe expansion. The uniform heat flux condition was imposed to the downstream of the abrupt expansion by using an electrically heated pipe. Experimental data are presented for local heat transfer rates and local axial velocities in the tube downstream of an abrupt 3:1 & 2:1 expansion. Air was used as the working fluid in the upstream tube, the Reynolds number was varied from 60, 00 to 120, 000 and the swirl number range (based on the swirl chamber geometry, i.e. L/d ratio) in which the experiments were conducted were L/d=0, 8 and 16. Axial velocity increased rapidly at r/R=0.35 in the abrupt concentric expansion turbulent flow through the test tube in unswirled flow. It showed that with increasing axial distance the highest axial velocities move toward the tube wall in the case of the swirling flow abrupt expansion. A uniform wall heat flux boundary condition was employed, which resulted in wall-to-bulk temperatures ranging from 24.deg. C to 71.deg. C. In swirling flow, the wall temperature showed a greater increase at L/d=16 than any other L/d. The bulk temperature showed a minimum value at the pipe inlet, it also exhibited a linear increase with axial distance along the pipe. As swirl intensity increased, the location of peak Nu numbers was observed to shift from 4 to 1 step heights downstream of the expansion. This upstream movement of the maximum Nusselt number was accompanied by an increase in its magnitude from 2.2 to 8.8 times larger than fully developed tube flow values.

  • PDF

액체로켓 연소실 냉각에 관한 실험적 연구 (An experimental study on the liquid rocket combustion chamber cooling)

  • 김병훈;박희호;정용갑;김유
    • 한국추진공학회지
    • /
    • 제5권2호
    • /
    • pp.1-7
    • /
    • 2001
  • 매우 높은 연소가스로부터 연소실을 보호하기 위하여 액체로켓에서는 재생냉각방법을 폭넓게 이용하고 있다. 재생냉각을 통한 로켓엔진의 냉각을 매우 효과적인 방법이지만, 이를 개발하기 위해서는 정확한 해석과정, 제작기술 등이 필요하다. 한다. 실제 소형 로켓엔진에 재생냉각을 이용한 엔진 냉각의 가능성을 확인하기 위하여 설계, 제작된 로켓으로 연소실험을 진행하였다. 실험에 사용한 연소실은 coolant passage 3 mm, 벽 두께 1 mm, stainless 304로 제작하였다. 최대연소압과 연소시간은 각각 400 psi와 60 sec이고, coolant 유량은 2 kg/s에서 0.12 kg/s까지 감소시키면서 실험하였다. 연소시험후 육안으로 검사한 결과 연소실에서 특별한 이상은 발견되지 않았다.

  • PDF

고추의 건조(乾燥) 공정(工程)에서 적외선(赤外線) 건조법(乾燥法)의 활용(活用)에 관한 연구(硏究) (Application of an Infrared Drying to Drying Process for Red Pepper)

  • 고학균;조용진;강석원
    • Journal of Biosystems Engineering
    • /
    • 제15권3호
    • /
    • pp.230-243
    • /
    • 1990
  • This study was conducted to investigate the possibility of application of an infrared drying to drying process for red pepper. The performance of seramic heaters and the variation of temperature and moisture content of red pepper were analyzed during an infrared drying of red peppers. Also, the quality of dried red pepper was analyzed. The following results were obtained from this study. 1. The surface temperature of infrared heaters and the rising time required for steady state were mainly affected by electrical power consumed. 2. The heat energy required for heating red pepper was proposed to be calculated by the equation in terms of enthalpy of air and net heat flux by infrared heater in a drying chamber. The statistical model for net heat flux was developed. 3. The performance of the infrared heater used for heating red pepper was much affected by the distance of radiation, and the difference of temperatures appeared between the radiated surface and the inside of red pepper. 4. Electrical capacity of the infrared heater had a significant effect on the heating of red pepper. However, the effect of shape of heater on heating was not significant. 5. The variation of temperature of red pepper largely appeared in the range of 30 to 60% (db) in moisture content. The temperature of red pepper was almost constant at low moisture content. 6. The temperature of red pepper and heating time had significant effects on the quality for radiant heating. 7. When the electrical capacity of infrared heater and the distance of radiation are carefully designed in a dryer with the insulated drying chamber, infrared drying might be very effective in red pepper drying.

  • PDF

UV 챔버 내부 온도 및 체류시간이 Urethane Acrylate의 경화속도에 미치는 영향 (The Effect of Temperature and Exposure Time on UV-curing of Urethane Acrylate)

  • 문승호;김광희;김정식
    • 한국산학기술학회논문지
    • /
    • 제13권9호
    • /
    • pp.3822-3826
    • /
    • 2012
  • 소형 UV 챔버 내부온도 및 챔버 내 체류시간이 Urethane Acrylate 의 경화속도에 미치는 영향을 조사하였다. UV 램프에 가해지는 Power를 60, 80, 100% 로 조절하여 UV 조사량 (UV dose)를 변경하였고 필름이 지나가는 챔버 내부의 가이드롤 (또는 패턴롤)에 냉각수를 투입하여 롤 자체의 온도에 변화를 주었다. 또한 코팅속도를 조절하여 챔버 내부에서의 체류 시간을 변경시켰는데 이들 조건들이 Urethane Acrylate 의 경화에 어떠한 영향을 미치는지를 알아보기 위하여 경화된 필름의 gel 분율을 측정, 비교하였다. 본 연구를 통해 Power가 증가 할수록 경화기 내부의 온도는 상승 하였으며 냉각수 투입에 따라 경화기 내부의 온도는 감소하였는데 이러한 경화기 내부의 온도변화는 UV 경화에 큰 영향을 미치지 않음을 알 수 있었다. 반면에 코팅속도가 증가할수록 경화필름의 gel 분율은 감소하였는데 이는 충분한 경화를 위해서는 경화기내부에서의 체류시간이 일정 이상이 되어야 함을 의미하였다. 한편, 체류시간에 따른 UV dose 측정 및 UV 램프주변의 열유동 해석을 통하여 램프주변의 온도분포 해석을 시도하였는데 이러한 결과들을 바탕으로 UV 경화기 구조 및 운전 조건이 UV 경화된 제품의 특성에 어떠한 영향을 미치는지 알 수 있었다.

Variations of NO Concentration Released from Fertilized Japanese Upland Soil Under Different Soil Moisture Conditions

  • Kim, Deug-Soo;Haruo Tsuruta;Kazuyuki Inubushi
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제14권E호
    • /
    • pp.9-17
    • /
    • 1998
  • Oxides of nitrogen play important roles in atmospheric chemistry. Soil has been recognized as a major natural source of NO, and its emission depends on soil parameters such as soil nitrogen availability, soil moisture and temperature. It is necessary to understand effects of these controlling parameters on soil NO emission. In order to understand soil moisture effects on NO emission, variations of NO concentration and existence of its equilibrium concentration were observed from ammonium fertilized Japanese upland soil prepared for different soil moisture conditions. The closed chamber technique was employed for this study. The significant increases in NO with soil moisture were found. Maximum was occurred at sample ID4 (55% of water-filled pore space (WFPS)), but it decreased as soil moisture increased. No significant NO concentration was emitted from soil sample without fertilizer, but there was significant NO in fertilized soil samples. The magnitudes of NO from soil increased with time and reached at steady state within ten minutes approximately. These results suggest that nitrogen input from fertilizer takes charge in the first step of sharp increase in NO emission, and then soil moisture becomes important factor to control NO emission from the soils. NO concentrations from soil were compared to those one-day after the experiment. Results from the comparison analysis suggest that the soil NO flux might have been stimulated by soil disturbances like mixing, and this is much more effective in dry soils rather than in wet soils. It was found that much less NO came out from soils after a day; suggesting that most of NO was released from the soils within a day after fertilizer application during our experiment. The length of NO releasing time span may depend on the amounts of fertilizer applied, soil moisture condition, and other soil physical parameters.

  • PDF

벼논 메탄 플럭스 측정용 폐쇄형 정적 챔버법: 고찰 (Closed Static Chamber Methods for Measurement of Methane Fluxes from a Rice Paddy: A Review)

  • 주옥정;강남구;임갑준
    • 한국농림기상학회지
    • /
    • 제22권2호
    • /
    • pp.79-91
    • /
    • 2020
  • 온실가스 배출량의 정확한 평가는 모든 기후변화 대응 연구의 초석이며, 신뢰성이 높은 온실가스 배출량의 평가는 모든 기후변화 예측 및 모델링 연구의 실질적인 기초자료로서 활용된다. 온실가스 배출량 산정 기반 기술로서 온실가스 배출량 현장 모니터링 기술, 배출계수의 불확도 평가 기술, 온실가스 배출량 및 저감량 검증 기술 등이 필수적이다. 이런 기반 기술의 핵심에는 토양-식생-대기 간에 교환되는 온실가스 플럭스 산정을 위해 가장 보편적으로 많이 사용되는 폐쇄형 정적 챔버법의 모니터링 기술이 자리 잡고 있다. 본 연구에서는 농업분야 온실가스 단일 배출원으로 가장 큰 부분을 차지하는 벼논에서 발생하는 CH4 플럭스 측정용 폐쇄형 챔버법의 기술적 근간과, 수동형 챔버법에서 전 과정의 자동화 시스템으로 발전을 거듭하고 있는 자동화 챔버 모니터링 기술개발에 대한 국내·외 동향을 소개하였다. 이를 바탕으로 보편적으로 사용하고 있는 챔버법의 표준화된 방법의 고찰과 정확한 현장 자료를 얻기 위한 품질관리 방안이 마련될 수 있을 것이다. 또한 CH4 플럭스 측정방법의 신뢰성 높은 기술 발전 방향에 대해 조망하여 벼논 CH4 배출량 산정 결과들의 신뢰성 향상에 기여하게 될 것으로 전망한다.

스테인레스 강 용접중 발생하는 망간의 발생량 및 함량변화에 관한 연구 (Generation Rate and Content Variation of Manganese in Stainless Steel Welding)

  • 윤충식;김정한
    • 한국산업보건학회지
    • /
    • 제16권3호
    • /
    • pp.254-263
    • /
    • 2006
  • Manganese has a role as both toxic and essential in humans. Manganese is also an essential component in the welding because it increases the hardness and strength, prevents steel from cracking of welding part and acts as a deoxidizing agent to form a stable weld. In this study, manganese generation rate and its content was determined in flux cored arc welding on stainless steel. Domestic two products and foreign four products of flux cored wires were tested in the well designed fume generation chamber as a function of input power. Welding fume was measured by gravimetric method and metal manganese was determined by inductively coupled plasma-atomic emission spectrophotometer. The outer shell of the flux cored wire tube and inner flux were analyzed by scanning electron microscopy to determine their metal compositions. Manganese generation rate($FGR_{mn}$) was increased as the input power increased. It was 16.3 mg/min at the low input power, 38.1 mg/min at the optimal input power, and up to 55.4 mg/min at the high input power. This means that $FGR_{mn}$ is increased at the work place if welder raise the current and/or voltage for the high productivity. The slope coefficient of $FGR_{mn}$ was smaller than that of the generation rate of total fume(FGR). Also, the correlation coefficient of $FGR_{mn}$ was 0.65 whereas that of FGR is 0.91. $FGR_{mn}$ was equal or higher in the domestic products than that of the foreign products although FGR was similar. From the electron microscopic analytical data, we concluded that outer shell of the wire was composed mainly of iron, chromium, nickel and less than 1.2 % of manganese. There are many metal ingredients such as iron, silica, manganese, zirconium, titanium, nickel, potassium, and aluminum in the inner flux but they were not homogeneous. It was found that both $FGR_{mn}$ and content of manganese was higher and more varied in domestic flux cored wires than those of foreign products. To reduce worker exposure to fumes and hazardous component at the source, further research is needed to develop new welding filler materials that improve the quality of flux cored wire in respect to these points. Welder should keep in mind that the FGR, $FGR_{mn}$ and probably the generation rate of other hazardous metals were increased as the input power increase for the high productivity.

Estimation of the Number of Sampling Points Required for the Determination of Soil CO2 Efflux in Two Types of Plantation in a Temperate Region

  • Lee, Na-Yeon(Mi-Sun);Koizumi, Hiroshi
    • Journal of Ecology and Environment
    • /
    • 제32권2호
    • /
    • pp.67-73
    • /
    • 2009
  • Soil $CO_2$ efflux can vary markedly in magnitude over both time and space, and understanding this variation is crucial for the correct measurement of $CO_2$ efflux in ecological studies. Although considerable research has quantified temporal variability in this flux, comparatively little effort has focused on its spatial variability. To account for spatial heterogeneity, we must be able to determine the number of sampling points required to adequately estimate soil $CO_2$ efflux in a target ecosystem. In this paper, we report the results of a study of the number of sampling points required for estimating soil $CO_2$ efflux using a closed-dynamic chamber in young and old Japanese cedar plantations in central Japan. The spatial heterogeneity in soil $CO_2$ efflux was significantly higher in the mature plantation than in the young stand. In the young plantation, 95% of samples of 9 randomly-chosen flux measurements from a population of 16 measurements made using 72-$cm^2$ chambers produced flux estimates within 20% of the full-population mean. In the mature plantation, 20 sampling points are required to achieve means within $\pm$ 20% of the full-population mean (15 measurements) for 95% of the sample dates. Variation in soil temperature and moisture could not explain the observed spatial variation in soil $CO_2$ efflux, even though both parameters are a good predictor of temporal variation in $CO_2$ efflux. Our results and those of previous studies suggest that, on average, approximately 46 sampling points are required to estimate the mean and variance of soil $CO_2$ flux in temperate and boreal forests to a precision of $\pm$ 10% at the 95% confidence level, and 12 points are required to achieve a precision of $\pm$ 20%.