• 제목/요약/키워드: Fluorography

검색결과 14건 처리시간 0.017초

Detection of Retinol-binding Protein in Bovine Yolk Sac, Chorion and Allantois by Immunoperoxidase Method

  • Liu, Kaung Huei
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제15권6호
    • /
    • pp.783-788
    • /
    • 2002
  • Bovine yolk sac at day 24 of pregnancy, and placental membranes (chorion and allantois) from days 70 and 100 of pregnancy were isolated and cultured in a modified minimum essential medium in the presence of $[^{35}S]$methionine. Proteins synthesized and secreted by isolated bovine yolk sac, chorion and allantois were analyzed by fluorography of two-dimensional polyacrylamide gel electrophoresis. Serum-like proteins,transferrin, ${\alpha}$-fetoprotein, ${\alpha}$1-antitrypsin and ${\alpha}$1-acid glycoprotein,were the major protein products of yolk sac. A 21 kDa protein produced by yolk sac was identified immunochemically as retinol-binding protein (RBP). Chorion and allantios from days 70 and 100 of pregnancy were active in protein synthesis and secretion. Both chorion and allantois did not secret serum-like proteins but secreted a number of neutral-to-acidic proteins including RBP. Secretory proteins produced by the yolk sac, chorion and allantois may play important roles in the embryonic development and the successful outcome of pregnancy. Antiserum against bovine placental RBP was employed to the immunocytochemistry by immunoperoxidase method. Immunoreactive RBP was localized in epithelial cells and island-like cell clones of yolk sac. Immunostaining for RBP was detected in simple columnar epithelium of chorion and in simple squamous epithelium of allantois. In the present study, proteins synthesized and secreted by yolk sac at day 24 of pregnancy, chorion and allantois from days 70 and 100 of pregnancy were characterized In addition, RBP was localized in yolk sac, chorion and allantois by immunoperoxidase method. The immunoperoxidase method has been proven to be a very effective technique to identify the cellular source of protein synthesis in extraembryonic membranes.

복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구 (Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy)

  • 홍선숙;강경미;성민숙;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

미국흰불나방 지방체에서 저장단백질-1의 수용체의 특성과 부분정제 (Characterization and Partial Purification of Storage Protein-i Receptor in the Fat Body of Hyphantria cunea)

  • 채권석;여성문;김학렬
    • 한국동물학회지
    • /
    • 제38권4호
    • /
    • pp.490-497
    • /
    • 1995
  • 미국흰불나방 의지방체 조직을 [35S]-메타이오닌이 포하된 배지에서 조직배양한 결과, 저장단백질-1(SP-1)의 전용기부터 용 1일 사이에 지방체로 흡수됨을 알았다. CHAPS, Triton X-100 등의 계면활성제를 농도별로 처리하여 막단백질의 용해도를 스크리닝한 뒤, anti-SP-1 polyclonal 항체를 쓴 Western blotting과 ligand blotting, 그리고 in vitro reductive methylation으로 14C을 표지한 저장단백질-1을 사용한 fluorography 등으로 1개의 수용체 밴드를 확인하였다. 1% Triton X-100으로 용해시킨 부분정제하였고, SDS-PAGE에 의해서 분자량을 측정한 결과 약 80 kDa로 나타났고 isoelectric focusing 시행 결과 등전점은 약 6.1로 계산되었다. 수용체 분자는 환원조건과 비환원조건의 차이와 전기영동 중의 온도에 따라서 SDS-PAGE상의 뚜렷한 밴드 양상의 차이를 나타내었다.

  • PDF

반도체소자를 이용한 관전압계의 개발 (The development of tube voltage meter using the semiconductor)

  • 선종률;신대철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제25권2호
    • /
    • pp.71-75
    • /
    • 2002
  • 검출능력이 우수하고 가격이 저렴하며 소형으로 제작할 수 있는 반도체검출기 중에서도 광전소지인 포토다이오드를 이용하였는데 이 소자는 특정표면이 입사광에 대하여 반응을 나타내는 소자인데 광 강도가 증가함에 따라 저항이 감소하는 특성을 이용하여 방사선 검출기를 제작하였다. 제작된 측정기는 접속식 측정기에 의해 검사치를 측정하여 기준치를 정하고 기존의 비접속형 측정기를 이용하여 제작된 비접속형 측정기와 정확성을 비교 검토하였다. 비교 결과 3가지 측정기의 모든 측정치가 기준치 범위에 속하였으며 정밀도를 분석하기 위하여 백분율 평균오차의 평균치를 구하였는데 기준측정기의 백분율평균오차의 평균치가 -0.02이고 비교측정기가 -0.22, 제작한 측정기가 0.17이었다.

  • PDF