• Title/Summary/Keyword: Fluorinated polymer

Search Result 92, Processing Time 0.018 seconds

Emulsion Polymerization and Surface Properties of Perfluoroalkylethyl Acrylate/Acrylate/Glycidyl Methacrylate Copolymers (퍼플로오로알킬에틸아크릴레이트/아크릴레이트/그리시딜메타크릴레이트 공중합체의 유화중합 및 그들의 표면특성)

  • Yoon, Jong-Kook;Lee, Jung-Hee;Kim, Ji-Soo;Lee, Young-Hee;Lee, Dong-Jin;Kim, Han-Do
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.170-176
    • /
    • 2012
  • A series of acrylic copolymers containing perfluoroalkyl acrylate were synthesized by 2-step emulsion polymerization of variety of acrylate monomers (ethyl acrylate, butyl acrylate or methyl methacrylate) with perfluoroalkyl ethyl acrylate (PFA) and glycidyl methacrylate (GMA) monomers. This study focused on effects of monomer compositions (the kind of acrylate monomer, contents of PFA and GMA) and composition of surfactants [(sodium dodecyl sulphate/nonylphenol 10mole ethoxylate (NP-10)] and initiator content on the contact angles and surface free energy. It was found that the copolymer having an optimum composition (BA : 87 wt%, GMA : 8.7 wt% and PFA : 4.3 wt%) was shown to be quite surface active [surface free energy : 19.89 mN/m and contact angles : $103.5^{\circ}$ (water) and $78.7^{\circ}$ (methylene iodide)] in the solid state. This result suggests that the optimal copolymer containing fluorinated monomer synthesized in this study have high potential as a low surface energy material, which may have high oil- and water-repellent surface and have been proposed as acrylic syntan for leather and also as soil-resistant/oil and water repellent coating for textiles and wood etc.

Preparation and Characterization of PVA/PSSA-MA Electrolyte Membranes Containing Silica Compounds and Surface Fluorination for Fuel Cell Applications (연료전지 응용을 위한 실리카 성분을 함유하며 표면불소화된 PVA/PSSA-MA 막의 제조 및 특성 연구)

  • Kim, Dae-Hoon;Lee, Bo-Sung;Rhim, Ji-Won
    • Polymer(Korea)
    • /
    • v.34 no.6
    • /
    • pp.540-546
    • /
    • 2010
  • In this manuscript, in order to reduce methanol permeability and, at the same time, to increase proton conductivity THS-PSA containing silica compound, responsible for methanol permeability reduction, and sulfonic acid, responsible for proton conductivity enhancement, was applied onto PVA/PSSA-MA membranes. And in order to improve durability, the resulting membranes, PVA/PSSAMA/THS-PSA, were exposed to 500ppm F2 gas at varying reaction times. The surface-fluorinated membranes were characterized through the measurement of contact angles, thermo-gravimetric analysis, and X-ray photoelectron spectroscopy to observe the physico-chemical changes. For the evaluation of the electro-chemical changes in the resulting membranes, its water contents, ion exchange capacity, proton conductivity, and methanol permeability were measured and then compared with the commercial membrane, Nafion 115. Finally, the membran electrode assembly(MEA) was prepared and the cell voltage against the current density was measured. As fluorination time increased, the contents of F2 increased up to maximum 4.3% and to depth of 50 nm. At 60 min of fluorination, the proton conductivity was 0.036 S/cm, larger than Nafion 115 at 0.024 S/cm, and the methanol permeability was $9.26E-08cm^2/s$, less than Nafion 115 at $1.17E-06cm^2/s$.

Transport Properties of Fluorinated Polyimide/PMMA-g-Silica Nanocomposite Membrane (PMMA가 그래프트된 실리카 나노입자를 포함한 불소계 폴리이미드 복합 분리막의 기체 투과 특성)

  • Kwon, Yu-Mi;Im, Hyun-Gu;Kim, Joo-Heon
    • Polymer(Korea)
    • /
    • v.34 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • To enhance the transport properties of gas separation membrane, we prepared 6FDA-6FpDA based polyimide membrane with PMMA-graft-silica nanoparticles. The silica was grafted PMMA which is miscible with 6FDA-based polyimide after surface treatment by 3-methacryloxypropyltrimethoxysilane ($\gamma$-MPS). The untreated silica/6FDA-6FpDA membrane showed greater permeability and less selectivity than PMMA-g-silica/6FDA-6FpDA due to its low dispersion. The transport properties of PMMA-g-silica/6FDA-GFpDA membrane were measured as a function of filler concentration. These membranes were evaluated using pure gases (He, $O_2$, $N_2$, $CO_2$). The increase in permeation was attributed to changes in the free volume distribution until 1 wt%. After 1 wt%, the permeability was decreased by excess silica which decreased effective area in polymer matrix. The selectivity was decreased with increasing permeability on the whole. However, the selectivity of $CO_2$ showed more enhance value.

Preparation and Characterization of Random Copolymer Electrolyte Membranes Containing PFCB (Perfluorocyclobutane) Group (PFCB (Perfluorocyclobutane) Group을 포함한 랜덤 공중합체 고분자 전해질 막 제조 및 특성연구)

  • Kim Jeong-Hoon;Kim Dong-Jin;Chang Bong-Jun;Lee Soo-Bok;Joo Hyeok-Jong
    • Membrane Journal
    • /
    • v.16 no.3
    • /
    • pp.221-229
    • /
    • 2006
  • This study is about the preparation and characterization of sulfonated random copolymer membranes containing perfluorocyclobutane (PFCB), fluorenyl, and sulfonyl units. The polymers were prepared through three synthetic steps, that is, the synthesis of a trofluorovinylether-terminated monomer, its thermal polymerization, and post-sulfonation using chlorosulfonic acid. A series of sulfonated random copolymers with different ion exchange capacity (IEC) were prepared by changing contents of fluorenyl uints in polymers with fixed molar ratio of chlorosulfonic acid during the post-sulfonation reaction. All the synthesized compounds were characterized by FT-lR, $^1H-NMR$, $^{19}F-NMR$, and Mass spectroscopy. As the content of sulfonated fluorenyl units increased, the IEC, water uptake, and ion conductivity of the sulfonated random copolymer membranes increased. The sulfonated random copolymer S-1 and S-2 showed higher values of ion conductivity than the Nafion-115 in a wide range of temperatures ($25{\sim}80^{\circ}C$).

Effect of Dispersion Solvent on Properties of Fluorinated Polymer Reinforced Composite Membrane for Fuel Cell by Solution Coating Method (용액 코팅법을 통한 연료전지용 불소계 전해질 강화복합막의 특성에 미치는 분산용매의 영향)

  • Yook, Seung Ho;Yoon, Ki Ro;Choi, Jihun;Lee, Ju Sung;Kim, Jong Min;Lee, Seung Woo;Lee, Kwan-Young;Kim, Jin Young
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.413-419
    • /
    • 2019
  • In the recent, as a world demand of energy resources has been transformed from fossil fuels to hydrogen-based clean energy resources, a huge attention has been attracted to increase the performance and decrease a production cost of core materials in fuel cell technology. The utilization of reinforced composite membranes as electrolytes in the polymer electrolyte membrane fuel cells can reduce the use of high cost perfluorosulfonic acid (PFSA), mitigate the cell impedance, and improve the dimensional stability as well as the interfacial stability, giving rise to achieve both an improved performance and a reduction of production costs of the fuel cell devices. In this study, we investigate the effects of physical characteristics and cell performances according to the various ionomer solvents in the solution based manufacturing process of reinforced composite electrolyte membrane.

Preparation and Characterization of Silicone and Fluorine-Oil-Based Ferrofluids

  • Kim, Jong-Hee;Park, Keun-Bae;Kim, Ki-Soo
    • Composites Research
    • /
    • v.30 no.1
    • /
    • pp.41-45
    • /
    • 2017
  • Magnetite nanoparticles were synthesized by adding an ammonium hydroxide to a mixed solution of iron (II) and (III) chlorides. A silicon surfactant of ${\alpha},{\omega}$-(3-aminopropyl)polydimethylsiloxane was adsorbed on the particles as dispersant and a polydimethylsiloxane polymer was used to prepare ferrofluids of silicone oil base. Fluorinated surfactants of anionic ammoniated perfluoroalkyl sulfonamide and nonionic fluoroaliphatic polymeric esters were applied to the particles and a perfluoropolyether was used to prepare ferrofluids of fluorine oil base. The experimental conditions were used for preparing the ferrofluids with concentrations of 200, 300 and 400 mg/mL, and density, magnetization and viscosity of the products were characterized. The density values increased in proportion to the concentration, indicating 1.11-1.27 g/mL for silicone-oil-based fluids and 1.95-2.10 g/mL for fluorine-oil-based fluids in the range of 200-400 mg/mL. The saturation magnetization of the silicone-oil-based and fluorine-oil-based fluids indicated 14.7, 24.4, and 30.7 mT and 15.8, 23.3, and 33.7 mT for 200, 300, and 400 mg/mL, respectively, depending on the content of magnetic particles in the fluid. The viscosity of the silicone-oil-based ferrofluids was highly stable compared to that of the fluorine-oil-based with increasing temperatures. The ferrofluids are usually applied to seals and speakers with the silicone base and to seals with the fluorine base.

Synthesis and Photovoltaic Properties of Copolymers with Fluorinated Quinoxaline and Fluorene Moiety (Fluorine이 도입된 Quinoxaline과 Fluorene 골격을 가진 고분자의 합성 및 특성분석)

  • Song, Suhee;Choi, Hyo Il;Shin, In Soo;Park, Seong Soo;Lee, Gun Dae;Park, Sung Heum;Jin, Youngeup
    • Applied Chemistry for Engineering
    • /
    • v.27 no.5
    • /
    • pp.467-471
    • /
    • 2016
  • New electron deficient moiety, 6,7-difluoro-2,3-dihexylquinoxaline, was developed for the push-pull type copolymer for organic photovoltaics (OPVs). The PFDTQxF with lower HOMO energy level was synthesized using fluorene and 6,7-difluoro- 2,3-dihexylquinoxaline by Suzuki polymerization. The PFDTQxF thin film shows two absorption peaks at 368 and 493 nm. The HOMO and LUMO energy levels of PFDTQxF are calculated -5.55 and -3.91 eV, respectively. The device comprising PFDTQxF showed a $V_{OC}$ value of 0.47 V, a $J_{SC}$ value of $4.48mA/cm^2$, and a FF of 0.32, which yielded PCE of 0.78%, under the illumination of AM 1.5.

An Experimental Study on the Fire Risk Assessment & Calculation Breakthrough Time through Permeation Test of Chemical Protective Clothing (화학보호복의 화재위험성 및 화학적 투과시험을 통한 파과시간산정에 관한 실험적 연구)

  • Ko, Jae-Sun;Park, Pyoung-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.21-30
    • /
    • 2010
  • We have test chemical resistance and flame retardant properties of chemical protective clothing Fabrics by the ASTM and ISO standard methods. The flame retardant test results show that polyethylene is poor in flame resistance but fluoroelastomer add to decabrom is excellent in flame resistance. Especially, nowadays heat protective clothing for firefighters, which is aluminized film layers laminated to aramid fabric, show the excellent flame resistance. However, the chemical resistance test results show that aluminium is high corrosive in 4M NaOH solution alone. The problem of corrosion can be overcome by employing multiple barrier film. Also, based on the result of flame retardant test, duel skin of polymer barrier film add to aluminum film and single skin of fluorinated rubber with flame retardant materials seems to be fit for the chemical protective clothing. Also the thermal protection and heat transfer test results show that TPP and HTI is increased assured that the continued study on fire risk assessment & chemical resistance of chemical protective clothing fabrics will contribute to the upgrade the performances of chemical protective clothing fabrics.

Surface Modification and Enzymatic Degradation of Microbial Polyesters by Plasma Treatments (플라즈마를 이용한 미생물합성 폴리에스테르의 표면개질과 효소분해성)

  • Kim, Jun;Lee, Won-Ki;Ryou, Jin-Ho;Ha, Chang-Sik
    • Journal of Adhesion and Interface
    • /
    • v.7 no.2
    • /
    • pp.19-25
    • /
    • 2006
  • Since the enzymatic degradation of microbial poly(hydroxylalkanoate)s (PHAs), such as poly[(R)-3-hydroxybutyrate] and poly[(R)-3-hydroxybutyrate-co-3-hydroxyvalerate] initially occurs by a surface erosion process, their degradation behaviors can be controlled by the change of surface property. In order to control the rate of enzymatic degradation, plasma modification technique was applied to change the surface property of microbial PHAs. The surface hydrophobic and hydrophilic properties of PHA films were introduced by $CF_3H$ and $O_2$ plasma exposures, respectively. The enzymatic degradation was carried out at $37^{\circ}C$ in 0.1 M potassium phosphate buffer (pH 7.4) in the presence of an extracellular PHB depolymerase purified from Alcaligenes facalis T1. The results showed that the significant retardation of initial enzymatic erosion of $CF_3H$ plasma-treated PHAs was observed due to the hydrophobicity and the enzyme inactivity of the fluorinated surface layers while the erosion rate of $O_2$ plasma-treated PHAs was not accelerated.

  • PDF

A Study on Sulfonated Fluorenyl Poly(ether sulfone)s as Catalyst Binders for Polymer Electrolyte Fuel Cells (고분자 전해질 연료전지 촉매층 바인더를 위한 Sulfonated Fluorenyl Poly(ether sulfone)에 관한 연구)

  • Cho, Won Jae;Lee, Mi Soon;Lee, Youn Sik;Yoon, Young Gi;Choi, Young Woo
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.2
    • /
    • pp.39-44
    • /
    • 2016
  • Oxygen reduction reaction in the fuel cell (ORR) plays a dominant role in the overall reaction. In addition, the low compatibility between the membrane and the binder consisted of different materials, greatly reduces the efficiency of the fuel cell performance. In view of these two problems, geometrically modified copolymers with 9.9_Bis (4-hydroxyphenyl) were synthesized via condensation reaction instead of conventional biphenol and were adopted as hydrocarbon ionomer binders. By utilizing these binders, two kinds of MEAs using fluorinated Nafion membrane and hydrocarbon based membrane were manufactured in order to electrochemical performance evaluation. With current-voltage curves, there was no significant difference in the 0.6 V when two types of membrane were applied. Also, tafel slope became considerably lower as compared to the Nafion membrane. Thus, it is determined that the new hydrocarbon binder is expected to contribute the improvement in performance of fuel cells.