• Title/Summary/Keyword: Fluoride-Ion

Search Result 222, Processing Time 0.022 seconds

Validation of analysis of urinary fluoride by ion selective electrode method (이온선택전극법에 의한 소변 중 불소 이온 분석법 검증)

  • Lee, Mi-Young;Yoo, Kye-Mook
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.333-338
    • /
    • 2014
  • A simple and sensitive analytical method for fluoride in urine by ion selective electrode (ISE) method was presented. Traditional buffer for fluoride determination using ISE is acetate-based one. Researchers have pointed out some drawbacks of the buffer for fluoride ISE analysis, and some other buffers including citrate-ammonium buffer and MES buffer have been studied for accurate determination of fluoride in urine here. These buffers provided promising results in environmental field, and this author focused on overcoming the interference of co-existing aluminium. The results show that MES-CyDTA buffer gave the best recovery with accuracy of 95-97.5% and precision of 1.9-7.9% for reference sample of 1.8-7.8 mg/L fluoride in urine, with smaller amount of samples and shorter analysis time compared with the traditional method which used acetate buffer. The method was applied to field samples, and which showed urinary of $0.98{\pm}0.38mg/g$ creatinine for workers in electric cable manufacturing factory (n=15) and $0.59{\pm}0.30mg/g$ creatinine for non-exposed workers (n=12).

THE INFLUENCE OF FLUORIDE ON REMINERALIZATION OF ARTIFICIAL DENTAL CARIES (인공치아우식의 재광화에 미치는 불소의 영향)

  • Han, Won-Seop;Kum, Kee-Yeon;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.161-173
    • /
    • 1996
  • The cariostatic effect of fluoride had been established by many epidemiologic and experimental studies. But, there are still different views on the mechnism of cariostasis and remineralization, especially about the proper fluoride concentration. The purpose of this study is to ascertain the remineralization of caries lesion and influence of fluoride concentration which affect remineralization by a study based on dynamic mechanism. The subjects, sound permanent teeth without demineralization or crack, were immersed in lactic acid buffered demineralization solution for 4 days. Dental caries with surface zone and subsurface lesion were artificially produced. All specimens were immersed in lactic acid buffered remineralization solution which had fluoride concentrations of 1 ppm, 2 ppm, 3 ppm for 10days. Final conclusions were obtained by observing the specimens for every 10 days under polarized microscopy. 1. Remineralization of caries lesion as well as demineralization of enamel were produced by changing the degree of saturation of lactic acid buffer solution. 2. Remineralization of caries lesion was facillitated by fluoride ion in lactic acid buffer solution. but, remineralization of the entire caries lesion was not increased as fluoride ion concentration increased.

  • PDF

Effects of Alkali and Chloride ions on the Electric Conduction of ZrF4-Based Heavy Metal Fluoride Glasses (알칼리 및 염소 이온이 지르코늄 플루오르화물 유리의 전기전도에 미치는 영향)

  • 한택상;박순자;조운조;정기호;최상삼
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.5
    • /
    • pp.601-608
    • /
    • 1989
  • Electrical properties of ZrF4-based heavy metla fluoride glasses were measured by the ac complex impedance method. The effects of alkali and chloride ions addition into fluoro zirconate glasses on the electrical conductivity were examined. The electrical conductivities of fluoride glasses show Arrhenian behavior in the temperature range of the experiment and were decreased by the addition of sodium fluoride up to 15mol%. Mixed alkali substitution resulted in conductivity minimum at intermediate composition which is commonly observed as mixed alkali effect' in alkali oxide glasses. Chloride ion substituted for fluoride ion was found to lower the conductivity.

  • PDF

A STUDY ON THE FLUORIDE CONTENT OF THE COMMERCIALLY AVAILABLE BEVERAGES AND THE FLUORIDE INTAKE OF CHILDREN (시판되는 각종 음료수내 불소 함량과 소아의 불소섭취에 관한 연구)

  • Lee, Mi-Na;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.125-138
    • /
    • 1997
  • Along with recent economic prosperity, the consumption of commercially available beverages has increased dramatically. Beverages on the market are replacing tap water and constituting an increasing large proportion of the total daily fluoride intake. If such changes in the source of fluid intake are not taken into consideration, effective fluoride intake would become difficult in the fluoridated area while there would be confusion as to the basis for proper fluoride supplement prescription in the nonfluoridated area. So, dietary consultation is recommended for every pediatric patient. This study was conducted to provide the reference for dietary consultations on the subject of fluoride supplement using 72 beverages on the market. The fluoride content was measured and the fluoride intake from each age groups was calculated using fluoride ion specific electrode and HMDS-microdiffusion technique. 1. The average fluoride concentration of the 72 beverages was $0.23{\pm}0.10ppm$, from 0.0106ppm to 2.2050ppm. 2. Natural fruit juices, diluted fruit juices, carbonated beverages and mixed beverages showed average fluoride concentration of $0.15{\pm}0.66ppm$, $0.09{\pm}0.11ppm$, $0.15{\pm}0.23ppm$, $0.50{\pm}0.66ppm$, respectively. There were significant differrence between diluted friut juice drinks and mixed beverage, and between the carbonated beverages and mixed beverges(p<0.05). 3. Using available data on the daily total consumption of beverages and the relative consumption of beverages on the market according to age, daily fluoride intake for various age groups was calculated. According to the results, 2 to 3 year-old children need 0.13mgF/day, those between 4 and 6 year-old need 0.15mgF/day, and those between 7 and 10 year-old need 0.17mgF/day.

  • PDF

Superhydrophilic Surface Modification of Polyvinylidene Fluoride by Low Energy and High Flux ion Beam Irradiation (저에너지 고출력 이온빔을 이용한 polyvinylidene fluoride 표면의 초친수성화)

  • Park Jong-Yong;Jung Yeon-Sik;Choi Won-Kook
    • Korean Journal of Materials Research
    • /
    • v.15 no.6
    • /
    • pp.382-387
    • /
    • 2005
  • Polyvinylidene fluoride (PVDF) surface was irradiated and became superhydrophilic by low energy (180 eV) and high flux $(\~10^{15}/cm{\cdot}s)$ ion beam. As an ion source, a closed electron Hall drift thruster of $\phi=70mm$ outer channel size without grid was adopted. Ar, $O_2$ and $N_2O$ were used for source gases. When $N_2O^+$ and $O_2^+$ reactive gas ion beam were irradiated with the ion fluence of $5\times10^{15}/cm^2$, the wetting angle for deionized water was drastically dropped from $61^{\circ}\;to\;4^{\circ}\;and\;2^{\circ}$, respectively. Surface energy was also increased up to from 44 mN/m to 81 mN/m. Change of chemical component in PVDF surface was analyzed by x-ray photoelectron spectroscopy. Such a great increase of the surface energy was intimately related with the increase of hydrophilic group component in reactive ion irradiated PVDF surfaces. By using an atomic force microscopy, the root-mean-square of surface roughness of ion irradiated PVDF was not much altered compared to that of pristine PVDF.

Effect of Fluoride Ion in the Analysis of Tin by HG-ICP-AES (HG-ICP-AES법에 의한 Tin 분석시 플루오르화 이온의 영향에 대한 연구)

  • Lim, Heon-Sung;Cho, Sung-Il;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.416-421
    • /
    • 2001
  • The optimization of the reductant and acid concentration for stannane($SnH_4$) generation was investigated by using a continuous flow hydride generator combined with an inductively coupled plasma-atomic emission spectrometer. Several different prereductants were studied to remove the interfering effect of fluoride ion on the hydride generating of tin. The optimum acid concentration was 0.5-1.0 M for the 1-2% $NaBH_4$ and 1.0 M NaOH and the interfering effect of fluoride ion was minimized using boric acid and L-cysteine mixed solution as a prereductant. The reconveries of tin at 20 ng/mL level in the solution containing fluoride ion were 100~108 %.

  • PDF

Organic Acid Extraction of Fluoride from Antarctic Krill Euphausia superba

  • Xie, Cheng Liang;Kim, Han Soo;Shim, Kil Bo;Kim, Yeon Kye;Yoon, Na Yeong;Kim, Poong Ho;Yoon, Ho Dong
    • Fisheries and Aquatic Sciences
    • /
    • v.15 no.3
    • /
    • pp.203-207
    • /
    • 2012
  • The amount of fluoride removed from Antarctic krill via organic acid extraction depends on the extraction time, concentration, extraction volume, and the nature of the acid itself. The fluoride content in Euphausia superba was determined by measuring the concentration of fluoride ion in acidic extracts using an ion-selective electrode. The best results were obtained by adding 50 mL of 0.01 M citric acid to 0.3-0.5 g of krill and extracting for 5 min. Under these conditions, recoveries of fluoride from frozen whole krill and krill meat were 95.6-99.5% and 97.5-101.3%, respectively. The dry basis fluoride contents of krill by-product, krill meat and the boiled krill were 705, 298, and 575 ppm, respectively. These levels were significantly reduced by citric acid extraction.

A STUDY ON THE ELIMINATION OF FLUORIDE IN A HOT SPRING WATER

  • Lee, Hyeon-Ki;Kim, Hwan-Gi
    • Environmental Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.77-83
    • /
    • 2006
  • The hot spring water of the north Jeonla province such as Wanggung, Jookrim, Seokjung, and Hwasim, has fluoride concentration of 3.9 mg/L, 12.7 mg/L, 1.9 mg/L, and 6.3 mg/L, respectively. These figures fairly exceed the Korean and WHO standard for potable water, which is 1.5 mg/L. Therefore, in this study, research on elimination of fluoride in a hot spring water of Jookrim region, which has the highest level of fluoride concentration level in the north Jeonla province, was carried out. In analysis of Jookrim hot spring water according to the water quality standard for potable water, pH was very high at 9.25 and the concentration of fluoride was 10 times higher than the standard at 18.2 mg/L. Other measurements were within the standard or not detected. After injecting 10g of activated carbon for elimination of fluoride, the fluoride concentration was measured at 13.5 mg/L, and when 70mL or more of alum 10 g/L solution was injected, the concentration was measured at 2.8 mg/L, and injecting 3g of lime was measured at 9 mg/L. Alum showed the best elimination performance among all individual injections. Injection of 25 mL of activated carbon and 100 mL of alum solution together reduced the fluoride concentration down to 1.3 mg/L, which is under the potable standard. Injection of lime 1g and 75 mL of alum 10 g/L solution together reduced fluoride concentration to 4.1 mg/L. From the modifying HRT, by using ion exchange resin column, the pH was stabilized when HRT was Imin and showed range of $6.7{\sim}7.8$. The fluoride concentration reduced gradually as the HRT increased, and satisfied the potable standard when HRT passed 6 min, and after 30 min HRT, the concentration of fluoride was 0.05 mg/L: almost eliminated.

Colorimetric and Fluorescent Recognition of Fluoride by a Binaphthol Thioureido Derivative

  • Tang, Lijun;Wang, Nannan;Guo, Jiaojiao
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2145-2148
    • /
    • 2012
  • A new thiourea based receptor (1) was synthesized and applied to fluoride ion recognition in acetonitrile solution. Receptor 1 displayed dual changes in absorption and fluorescence emission intensities selectively for fluoride ions. The interaction of 1 with fluoride undergoes a deprotonation process that is confirmed by $^1H$ NMR titration.

Determination of fluoride in fluorite mine wastewater by ion chromatography with post-wash technique (후세척-이온크로마토그래피를 이용한 형석 광산 폐수 중 플루오라이드 정량)

  • Song, Kyung-Sun;Eum, Chul-Hun;Kim, Sang-Yeon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.383-388
    • /
    • 2006
  • Simple post-wash method by ion chromatography (IC) was established for the rapid and precise determination of fluoride ion in wastewater from mine in fluorite mineralized area. High sulfate in sample was retained in a pre-column and less strongly held fluoride ion was transferred to the principal separation system using modified conventional IC with switching technique. An analytical column with high capacity (AS 9 HC) was used as a pre-column to retain the amount of high sulfate. A guard column (AG 14) as a separation column was used to increase the response of fluoride and reduce the system pressure. According to the recovery of fluoride ion with one detector and the observation of sulfate peak with another conductivity detector, the optimum switching time of 10-port chromatographic injector was 4.3 min. The limit of detection (S/N = 3) of fluoride in synthetic solution containing $500mg\;L^{-1}$ sulfate was $2.4{\mu}g/L$, with $25{\mu}L$ sample volume.