• Title/Summary/Keyword: Fluoride anion detection

Search Result 4, Processing Time 0.017 seconds

A Naked Eye Detection of Fluoride with Urea Receptors Which have both an Azo Group and a Nitrophenyl Group as a Signaling Group

  • Dang, Nhat Tuan;Park, Jin-Joo;Jang, Soon-Min;Kang, Jong-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1204-1208
    • /
    • 2010
  • Anion recognition via hydrogen-bonding interactions could be monitored with changes in UV-vis absorption spectra and in some cases easily monitored with naked eye. Urea receptors 1 and 2 connected with both an azo group and a nitrophenyl group as a signaling group for color change proved to be an efficient naked eye receptor for the fluoride ion. The anion recognition phenomena of the receptors 1 and 2 via hydrogen-bonding interactions were investigated through UV-vis absorption and $^1H$ NMR spectra.

Analysis of Anions by Indirect Photometric Detection (I) (간접 분광 검출법에 의한 음이온의 분석(I))

  • Park, Man-Ki;Kim, Bak-Kwang;Park, Jeong-Hill;Kim, Kyoung-Ho;Lee, Mi-Yung;Jung, Jae-Eun
    • YAKHAK HOEJI
    • /
    • v.34 no.3
    • /
    • pp.215-218
    • /
    • 1990
  • An ion chromatographic method based on indirect photometric detection of UV transparent anions was developed. Separation of anion was accomplished on strong anion exchange column (Waters SAX) using UV detector at 254 nm. Among examined UV-active additives (Dns-H, Dns-glu, Dnsser, Dns-val), Dns-glu showed the highest sensitivity. Studies on the effects of the pH and ionic strength of eluent revealed that the increase of pH and ionic strength of the eluent decreased capacity factor. The best eluent for the separation of acetate, fluoride, chloride, nitrate and bromide was $1\;{\times}\;10^{-4}M$ Dns-glu in 5 mM phosphate buffer (pH 6.30). The detection limit of chloride ion was 2.1 ng in this condition.

  • PDF

Optimization of solid phase extraction and simultaneous determination of trace anions in concentrated hydrofluoric acid by ion chromatography (불산 중 극미량 음이온 분석을 위한 고상 추출법 및 이온크로마토그래프를 이용한 동시분석법 확립)

  • Yoon, Suk-Hwan;Jo, Dong-ho;Kim, Hyun-Ji;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.219-224
    • /
    • 2016
  • 불산 중 극미량 음이온의 고상추출과 이온크로마토그래프를 이용한 고감도 분석법이 개발되었다. 불산 중 불소이온이 고상에 의해 제거하였고 이어서 음이온 (F, CH3COO, Cl, Br, NO3, PO43−, SO42−)들이 이온크로마토그래프를 이용하여 연속적으로 분리하였다. 고상 추출법에 영향을 주는 각 인자들 (흡착제의 선택, 시료의 부피 및 pH, 용출 용액과 용출용액의 부피)을 결정하였으며 그 결과 흡착제로서 Oasis WAX 컬럼이 가장 우수하였고 1.0 mL의 시료부피, 용출용액으로 50 mM 초산암모늄염 5 mL가 분리능에서 가장 우수하였다. 개발한 방법에 의한 음이온 (Cl, Br, NO3, PO43−, SO42−)들의 방법검출한계는 25 % 불산용액 (w/w) 중에 0.04~0.30 µg/L의 범위를 보였고 정밀도는 20.0와 40.0 µg/L의 농도에서 5 % 이내를 보였다. 한 제조회사에 의한 25 % 불산 중 음이온의 4.2에서 47.5 µg/L의 범위로 모두 검출되었다. 이 방법은 시험절차가 간단하고, 재현성 및 감도가 좋아서 반도체회사에서 불산 중 음이온 불순물을 정도 관리하는데 매우 유용한 방법이 될 것으로 판단된다.