• 제목/요약/키워드: Fluorescent dye

검색결과 221건 처리시간 0.032초

Multilayer White Organic Light-Emitting Diodes with Blue Fluorescent and Red Phosphorescent Materials

  • Seo, Ji-Hoon;Kim, Jun-Ho;Lee, Kum-Hee;Kim, You-Hyun;Kim, Woo-Young;Yoon, Seung-Soo;Kim, Young-Kwan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1067-1070
    • /
    • 2006
  • We have demonstrated highly efficient WOLED with two separated emissive layers using a blue fluorescent dye and a red phosphorescent dye. The maximum luminous efficiency of the device was 11.2 cd/A at $20\;mA/cm^2$ and $CIE_{x,y}$ coordinates varied from (x = 0.33, y = 0.37) at 6V to (x = 0.25, y = 0.33) at 14V.

  • PDF

Electroluminescence of a red fluorescent dye doped in an $Alq_{3}$:rubrene Mixed Host

  • Kang, Hee-Young;kang, Gi-Wook;Lee, Chang-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.948-951
    • /
    • 2003
  • The electroluminescence (EL) properties were studied in organic light-emitting diodes with a red fluorescent dye, 4- (dicyanomethylene)- 2- tert-butyl-6 (1,1,7,7-tetramethyljulolidyl-9-enyl)- 4H- pyran (DCJTB) doped into tris-(8-hydroxyquinoline)aluminum ($Alq_{3}$), rubrene and the mixed matrix of $Alq_3$ and rubrene. The device with DCJTB doped into the $Alq_{3}$:rubrene mixed host shows an efficient red emission from DCJTB with a negligible EL emission from $Alq_{3}$ and a lower EL onset voltage compared to the device with DCJTB doped into the $Alq_{3}$ only host. The quantum efficiency is almost temperature-independent for the device with the $Alq_3:rubrene$ mixed host. The results indicate that recombination of injected electrons and holes occurs on rubrene and subsequent energy transfer to DCJTB dominates in the device with the $Alq_{3}$:rubrene mixed host.

  • PDF

A comparative study of three different viability tests for chemically or thermally inactivated Escherichia coli

  • Park, Seon Yeong;Kim, Chang Gyun
    • Environmental Engineering Research
    • /
    • 제23권3호
    • /
    • pp.282-287
    • /
    • 2018
  • Three different methods of bacterial viability monitoring were compared to detect chemically or thermally inactivated Escherichia coli. Direct colony enumeration, live/dead bacterial cell staining with a fluorescent dye, and the dehydrogenase activity assay were compared with respect to their ease of use and time required to perform the three different tests. The green (live cell)/red (dead cell) ratio obtained from the fluorescent bacterial cell staining approach showed a linear relationship with the colony forming units; the result obtained with dehydrogenase was similar to those. The sensitivity of the monitoring methods to detect bacterial deactivation varied with different disinfection conditions. After thermal treatment, the sensitivity of the staining approach was lower, while that of the dehydrogenase activity assay was the highest. After chemical treatment, the sensitivity of detection for both methods was similar.

비외사골동수술법을 이용한 외상성 뇌척수액 비루의 치료 (Management of Traumatic Cerebrospinal Fluid Rhinorrhea using External Ethmoidectomy Approach)

  • 임상철;조재식
    • 대한기관식도과학회지
    • /
    • 제3권1호
    • /
    • pp.169-173
    • /
    • 1997
  • Cerebrospinal fluid (CSF) rhinorrhea usually occurs as a result of trauma including operation. Unheated CSF rhinorrhea may induce major morbidity such as meningitis and brain abscess, etc. This paper presents a review of four cases of traumatic CSF rhinorrhea Sites of CSF leakage were easily found out by intrathecal fluorescent dye injection. Surgery was performed by external ethmoidectomy approach and dural tear and bone defect was repaired with abdominal fat and free mucosal graft taken from amputated middle turbinates. We conclude that repair using free fat and mucosal graft via external ethmoidectomy approach could be accepted as the intial method of CSF rhinorrhea management.

  • PDF

올리고머형 음이온성계면활성제 수용액에서 안료의 분산안정성(제 3보);형광성이 큰 올리고머 계면활성제의 합성 및 그의 계면성 (Suspension Stability of Pigments in Aqueous Solution of Anionic Oligo-Type Surfactants(part 3);Synthesis of Anionic Oligo Surfactant having Fluorescent Intensity and Their Properties)

  • 이향우;이진희;주명종;남기대
    • 한국응용과학기술학회지
    • /
    • 제14권1호
    • /
    • pp.109-115
    • /
    • 1997
  • Fluorescent anionic oligo surfactants were synthesized by the condensing products of long chain alkylvinylether-maleic anhydride cooligomers and resorcinol including dye structures. Their various surface activities and dispersing action were studied on the aqueous solution. These oligo surfactants exhibited a remarkable surface tension lowering property, lower foaming and a large dispersing action for the particles of ${\alpha}-copper$ phthalocyanine blue. Further it was ascertained that the binding of oligo surfactant onto the pigment surface caused the deviation towards lower wavelengths at the maximum fluorescent intensity as compared with aqueous oligo surfactant solutions, These surface active properties of the oligo surfactants may be attributed to rigid and hydrophobic structure of dye groups, besides surface-active groups of alkylether groups and carboxylic group of the anionic oligo surfactants.

형광 나노 포러스 박막을 이용한 표면 온도 센서의 제작 및 성능 연구 II (Fabrication and Performance Investigation of Surface Temperature Sensor Using Fluorescent Nanoporous Thin Film II)

  • 김현정;유재석;박진일
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.674-678
    • /
    • 2013
  • We present a non-invasive technique to the measure temperature distribution in nano-sized porous thin films by means of the two-color laser-induced fluorescence (2-LIF) of rhodamine B. The fluorescence induced by the green line of a mercury lamp with the makeup of optical filters was measured on two separate color bands. They can be selected for their strong difference in the temperature sensitivity of the fluorescence quantum yield. This technique allows for absolute temperature measurements by determining the relative intensities on two adequate spectral bands of the same dye. To measure temperature fields, Silica (SiO2) nanoporous structure with 1-um thickness was constructed on a cover glass, and fluorescent dye was absorbed into these porous thin films. The calibration curves of the fluorescence intensity versus temperature were measured in a temperature range of $10-60^{\circ}C$, and visualization and measurement of the temperature field were performed by taking the intensity distributions from the specimen for the temperature field.

Applying Fluorescent Whitening Agent and Tinting Dye on Paper

  • Wang Li-Jun;Chen Fu-Shan;An Kook-Hun;Yoon Byung-Ho
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2004년도 추계학술발표집
    • /
    • pp.100-105
    • /
    • 2004
  • The difference of whiteness, brightness and lightness was clearly explained in this paper through the use of a tinting dye and a fluorescent whitening agent which are commercially wide]y used to make paper look whiter. Other optical properties such as tint, color shade, and color difference were also discussed. It was suggested that in comparing two tinting dyes, lightness $(L^*)$ is the most important property to be compared, while whiteness data should be used in caution in order not to surpass its significant range, and $a^*,\;b^*$ values can also be used to see the change of color shades together with ${\Delta}E$ as color difference. In comparing two fluorescent whitening agents, whiteness or brightness values are most important to be compared, but lightness values are not suitable fur this purpose; $a^*,\;b^*$ and color difference ${\Delta}E$ can also be referred, but with less significance.

  • PDF

온도 민감 형광을 이용한 마이크로 스케일 표면온도 측정 (Surface Temperature Measurement in Microscale with Temperature Sensitive Fluorescence)

  • 정운섭;김성욱;김호영;유정열
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.153-160
    • /
    • 2006
  • A technique for measuring surface temperature field in micro scale is newly proposed, which uses temperature-sensitive fluorescent (TSF) dye coated on the surface and is easily implemented with a fluorescence microscope and a CCD camera. The TSF dye is chosen among mixtures of various chemical compositions including rhodamine B as the fluorescent dye to be most sensitive to temperature change. In order to examine the effectiveness of this temperature measurement technique, numerical analysis and experiment on transient conduction heat transfer for two different substrate materials, i. e., silicon and glass, are performed. In the experiment, to accurately measure the temperature with high resolution temperature calibration curves were obtained with very fine spatial units. The experimental results agree qualitatively well with the numerical data in the silicon and glass substrate cases so that the present temperature measurement method proves to be quite reliable. In addition, it is noteworthy that the glass substrate is more appropriate to be used as thermally-insulating locally-heating heater in micro thermal devices. This fact is identified in the temperature measuring experiment on the locally-heating heaters made on the wafer of silicon and glass substrates. Accordingly, this technique is capable of accurate and non-intrusive high-resolution measurement of temperature field in microscale.

수술현미경용 다중형광 관측 시스템 연구 (Development of Indocyanine Green and 5-Aminolevulinic Acid Detection System for Surgical Microscope)

  • 김홍래;이현민;윤웅배;김영재;김석기;유헌;주재영;김광기;이승훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권1호
    • /
    • pp.16-21
    • /
    • 2015
  • Indocyanine green(ICG) and 5-aminolevulinic acid(5-ALA) have been widely used to mark blood vessels or tumors. However, fluorescent dye detection systems were designed to use one type of dyes only. In this study, we proposed a detection system capable of detecting Indocyanine green and 5-aminolevulinic acid. Multiple filters and light sources are integrated into a single system. In this study, we performed analysis of fluorescent dyes and configured a detection system. During the analysis, it was found that Indocyanine green and 5-aminolevulinic acid have the maximum intensity at $40{\mu}M$. We designed light source for fluorescent dyes and conducted compatibility test using a commercial surgical microscope. The fluorescent dye detection system was configured based on the experimental results. The developed system successfully detects Indocyanine green and 5-aminolevulinic acid. Therefore, more efficient surgical operations can be achieved using both fluorescent dyes at the same time. We expect that the developed system can increase the survival rate of patients.

A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft

  • Lim, Hyoseob;Han, Dae Hee;Lee, Il Jae;Park, Myong Chul
    • Archives of Plastic Surgery
    • /
    • 제41권2호
    • /
    • pp.126-132
    • /
    • 2014
  • Background Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to determine the viability of avulsed flaps in the operation field after intravenous injection of fluorescein dye. Methods We experienced 13 cases during 16 months. Fifteen minutes after the intravenous injection of fluorescein dye, the avulsed skin flaps were examined and non-fluorescent areas were marked under Wood's lamp illumination. The marked area was defatted for full-thickness skin grafting. The fluorescent areas were sutured directly without tension. The non-fluorescent areas were covered by defatted skin. Several days later, there was soft tissue necrosis within the flap area. We measured necrotic area and revised the flap. Results Among all the cases, necrotic area was 21.3% of the total avulsed area. However, if we exclude three cases, one of a carelessly managed patient and two cases of the flaps were inappropriately applied, good results were obtained, with a necrotic area of only 8.4%. Eight patients needed split-thickness skin grafts, and heel pad reconstruction was performed with free flap. Conclusions A full-thickness skin graft from an avulsed flap is a good method for addressing aesthetic concerns without producing donor site morbidity. Fluorescein dye is a useful, simple, and cost-effective tool for evaluating flap viability. Avulsed flap injuries can be managed well with Wood's lamp illumination and a full-thickness skin graft.