• Title/Summary/Keyword: Fluorescent Lamp

Search Result 690, Processing Time 0.041 seconds

The Research of Electrical and Optical Properties for 24″ Flat Panel-Florescent Lamp (24″평판형광램프에 관한 전기적광학적특성연구)

  • 김수용;박승곤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.527-530
    • /
    • 2001
  • In this paper, the basic characteristics of flat fluorescent lamp using ultraviolet generate from gas discharge and powder type electrolyminescent display(P-ELD) using a phenomenon of the light emission eaused by the electrical field applied to phosphor are studied. The lamp is a simple structure with insulator layer, phosphor layer, and gas gap. Current(displacement current + discharge current) in flat fluorescent lamp using.

  • PDF

The improvement of the Fluorescent Lamp is setted by frequency in the external oscillation (형광램프용 전자식 안정기 타려발진 모듈의 주파수 설정에 따른 신뢰성 향상 방안)

  • Ko, Jae-Jun;Yang, Byong-Mun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1374-1376
    • /
    • 2005
  • In driving for the electronic ballast lamp which higher quality and performance according to it's frequency which can be critically in Fluorescent Lamp in reliability to the external oscillation electronic ballast module. For the Fluorescent Lamp I cheesed the high frequency T5 lamp that is outstanding in the EU market.

  • PDF

Parameter and Brightness Characteristic of Antena according to Coil turns on Electrodeless Fluorescent Lamp (무전극 램프 안테나의 권선수에 따른 휘도와 파라미터 특성)

  • Yang, Jong-Kyung;Choi, Gi-Seung;Pack, Gwang-Hyeon;Choi, Yong-Sung;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.281-284
    • /
    • 2004
  • In Recent, it became necessary to envelope the technology about electrodeless fluorescent lamp according to demand of the electrodeless fluorescent lamp system that used higher efficiency and advantage of long-lifetime. Especially, in the electrodeless fluorescent lamp which used H-mode, efficiency of lamp is decided from matching parameter of antena and inverter So it is of the utmost importance to design antena and inverter. Therefore, this paper used a transformer principle for efficiency rising of electrodeless fluorescent lamp and interpreted an equivalent circuit, used an impedance analyzer in order to confirm a performance enhancement of lamp along design of antenna, and confirmed parameter characteristic of R, L, C, Z, Phase, Q-factor along a change of magnetic flux density. Also, this paper confirmed a luminance characteristic of electrodeless lamp along parameter change with measuring optical characteristic along a change of magnetic flux density.

  • PDF

2.5MHz Zero-Voltage-Switching Resonant Inverter for Electrodeless Fluorescent Lamp (무전극 램프 점등용 2.5MHz급 ZVS 인버터 개발에 관한 연구)

  • 박동현;김희준;조기연;계문호
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.261-265
    • /
    • 1997
  • Driving the electrodeless fluorescent lamp, the high ac voltage with high frequency is required. The linear power amplifier has been widely used as a driving circuit of electrodeless fluorescent lamp. However, the low efficiency of the power amplifier causes th driving circuit to be replaced by a PWM switching inverter. In order to use a PWM switching inverter as the driving circuit of an electrodeless fluorescent lamp, the high switching frequency is required. But due to the switching loss at switches of the inverter, the limitation of high switching frequency appears in the inverter. One solution to this limitation is to reduce the switching loss by using the zero voltage switching technique. In this paper, zero voltage switching resonant inverter for driving an electrodeless fluorescent lamp is discussed. The results of analysis about the inverter are presented and the equations for design are established. And the validity of the analyzed results are verified through the experiment.

  • PDF

A study on Electrical and Electromagnetic Properties for Driving the Ring-shaped electrodeless fluorescent lamp (환형 무전극 형광램프 구동을 위한 전기적, 자기적 특성 분석)

  • Jo, Ju-Ung;Lee, Young-Hwan;Nam, Joong-Hee;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.69-72
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, we present measurement results of electrical characteristics of a ring-shaped electrodeless fluorescent lamp as a function of frequency and number of coil turns using a highly permeable Mn-Zn ferrite. It is found that the impedance are increased while the quality factor decreases as frequency increases.

  • PDF

Impedance and Q-factor of frequence dependance accoding to ferrites on electrodeless fluorescent lamp (무전극 형광램프의 페라이트 종류에 따른 임피던스 및 Q-Factor의 주파수 의존성)

  • Kim, Hoe-Geun;You, Dae-Won;Park, Sung-Mook;Pack, Gwang-Hyeon;Choi, Young-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.3-7
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relativie property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined resistance kind, impedance, Q-factor's frequency characteristic by ferrite. Impedance, resistance and capacitance did not show difference in start frequency 2.65 [MHz] but there was difference quantity. We could know Q-factor's difference according to material, and Q-factor's is important part of antenna design.

  • PDF

Discharge Characteristics of flat fluorescent lamp with printable MgO layer (프린팅 법으로 MgO레이어를 적용한 평면 형광 램프의 방전특성)

  • Kim, Seon-Ho;Ahn, Sung-Il;Lee, S.E.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.443-443
    • /
    • 2008
  • 차세대 LCD back light 시스템으로 Xe plasma plat lamp를 주목하고 있으나 자외선 여기 효율이 떨어져 램프의 휘도 및 광 효율이 낮은 단점을 가지고 있어 이에 따른 개선이 요구되고 있다. MgO는 AC-PDP에서 방전전압의 저하, 방전의 안정성, 동작마진과 같은 특성에 영향을 미치고 있기에 이번 연구 에서는 졸겔법으로 제작한 MgO를 프린팅 방법으로 flat fluorescent lamp에 적용하였다. 실험시 사용한 flat fluorescent lamp의 경우 ITO 전극과 MgO layer 그리고 형광체층을 가진 두 장의 유리판 사이에 Ne-Xe기체를 채운 단순한 구조로 제작하였다. 실험은 압력과 방전거리에 따른 특성을 살펴보았으며, 그 결과 MgO layer 채용한 경우 방전 전압의 감소 및 static margin의 증가를 알 수 있었다.

  • PDF

A Transient Model Analysis of a Fluorescent Lamp at Startup Time (형광램프의 기동시 과도특성 모델 해석)

  • 함중걸;백수현
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.5
    • /
    • pp.52-56
    • /
    • 1996
  • Fluorescent lamps are widely accepted to energy efficient commercial lighting applications. In designing a fluorescent lamp system, a ballast design heavily relies on the characteristic of a fluorescent lamp under consideration. Especially, at startup time, the transient characteristic of a fluorescent lamp puts much tighter specification of a design. In this paper, based on the transient characteristic at the startup time, a transient behavioral model of a fluorescent lamp is presented with an equivalent circuit. The model is applicable to the wide range of fluorescent lamps provided by different manufacturers. The experimental results are compared with the results provided by PSPICE simulation. The result shows the model is effective In practice. As a result, we could identify more accurate startup constraints to decide the design of either an electro mechanical or an electronic ballast.

  • PDF

Electromagnetic Simulation of Ring-shaped Electrodeless fluorescent Lamps and its Electrical and Optical Characteristics (환형 무전극 형광램프의 전자계 시뮬레이션, 전기적 및 광학적 특성)

  • 최용성;조주웅;이영환;김광수;박대희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.552-559
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficiency replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program(Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250 KHz and some specific conditions. The optical characteristics were measured luminance and a temperature and an optical spectrum distribution for 10 min in a one minute interval at the same time. With a goal of finding alternative materials, we show measurement results of electrical characteristics of a ring-shaped electrodeless fluorescent lamp as a function of frequency and the number of coil turns using a highly permeable($\mu$$_{r}$(equation omitted) 2,000) Mn-Zn ferrite. These results are compared with those of conventional ring-shaped electrodeless fluorescent lamp. It is found that the resistance, inductance and impedance are increased while the quality factor decreases as frequency increases.s.

Effects of the Xe content on the electro-optical properties in the mercury-free Flat Fluorescent Lamp

  • Chung, Kyu-Yong;Lee, Sang-Mok;Jeong, Yoon-Chul;Sohn, Sang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1577-1579
    • /
    • 2007
  • Xe content is one of important factors related to characteristics of the mercury-free flat fluorescent lamp. The electro-optical properties of lamp were investigated for wide range of Xe content in Xe-Ne mixing gas. The maximum luminance of $9,289\;cd/m^2$ and efficacy of 3 lm/W was obtained with Xe 90 %.

  • PDF