• Title/Summary/Keyword: Fluorescent Dye

Search Result 221, Processing Time 0.03 seconds

STUDIES OF CELL COMMUNICATION BY USING GAP JUNCTION CHANNELS RECONSTITUTE IN UNILAMELLAR LIPID VESICLES

  • Joe, Cheol-O
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 1996.07a
    • /
    • pp.6-6
    • /
    • 1996
  • Gap junction channels were reconstituted into unilamellar liposomes using immunoaffinity purified connexin 32 gap junction protein from rat liver. Vesicles containing open channels and close channels were separated by means of iso-osmolar sucros density gradient sedimentation. The open channels formed in lipid vesicles were permeable to a fluorescent dye molecule, lucifer yellow of which the hydrodynamic size is similar to pore size of gap junctions in vivo. (omitted)

  • PDF

Nano-scale Proteomics Approach Using Two-dimensional Fibrin Zymography Combined with Fluorescent SYPRO Ruby Dye

  • Choi, Nack-Shick;Yoo, Ki-Hyun;Yoon, Kab-Seog;Maeng, Pil-Jae;Kim, Seung-Ho
    • BMB Reports
    • /
    • v.37 no.3
    • /
    • pp.298-303
    • /
    • 2004
  • In general, a SYPRO Ruby dye is well known as a sensitive fluorescence-based method for detecting proteins by one-or two-dimensional SDS-PAGE (1-DE or 2-DE). Based on the SYPRO Ruby dye system, the combined two-dimensional fibrin zymography (2-D FZ) with SYPRO Ruby staining was newly developed to identify the Bacillus sp. proteases. Namely, complex protein mixtures from Bacillus sp. DJ-4, which were screened from Doen-Jang (Korean traditional fermented food), showed activity on the zymogram gel. The gel spots on the SYPRO Ruby gel, which corresponded to the active spots showing on the 2-D FZ gel, were analyzed by a matrix-assisted laser desorption ionization time of flight (MALDI-TOF) mass spectrometric analysis. Five intracellular fibrinolytic enzymes of Bacillus sp. DJ-4 were detected through 2-D FZ. The gel spots on the SYPRO Ruby dye stained 2-D gel corresponding to 2-D FZ were then analyzed by MALID TOF MS. Three of the five gel spots proved to be quite similar to the ATP-dependent protease, extracellular neutral metalloprotease, and protease of Bacillus subtilis. Also, the extracellular proteases of Bacillus sp. DJ-4 employing this combined system were identified on three gels (e.g., casein, fibrin, and gelatin) and the proteolytic maps were established. This combined system of 2-D zymography and SYPRO Ruby dye should be useful for searching the specific protease from complex protein mixtures of many other sources (e.g., yeast and cancer cell lines).

Degradation and Ecotoxicity Reduction of Reactive Dye by Using Advanced Oxidation Process (고도산화공정을 이용한 반응성 염료의 제거 및 생태독성 저감)

  • Seo, Kyung Ae;Park, Jae Hong;Jung, Soo Jung;Lim, Byung Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.204-211
    • /
    • 2013
  • In this study, the deriving optimum conditions for decolorization of Acid Orange II solution was carried using $TiO_2$ advanced oxidation process. After that, on base of the deriving results, the range of dye concentration was estimated. In addition, acute toxicity test was also carried to assess toxicity unit according to decolorization and TOC removal. In case of the blockage of light, 20 mg/L of dye solution, and 0.5 g $TiO_2$, the effect of decolorization at pH 3 was larger than at pH 6 and 10, so it was shown that decolorization is dependent on pH. The use of 5 g $TiO_2$ showed best performance of decolorization, but that of 3 g $TiO_2$ was chosen to optimum condition in considering of economical aspects. Four light sources, sun, fluorescent lamp, BLB lamp, and UV-B lamp, were used and decolorization was 99.4% and 100% at 50 mg/L, 98.6% and 99.7% at 100 mg/L for sun and UV-B lamp, respectively. In spite of the optimum condition of decolorization at pH 3, the evaluation of acute toxicity test showed highly toxic. In conclusion, although the optimum treatment of dye solution is performed, water ecology can be polluted in discharging it into water system. Therefore, it is needed to study of water ecological system with dye water treatment, and it takes all the circumstances into consideration.

DETECTION OF PROXIMAL CARIES USING LASER FLUORESCENCE (레이저 형광법을 이용한 인접면 우식증 탐지효과)

  • Mo, Kyung-Hee;Yoon, Jung-Hoon;Kim, Su-Gwan;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.323-330
    • /
    • 2004
  • The purpose of this study was to evaluate the diagnostic validity of early proximal caries lesions using laser fluorescence and whether the detection could be enhanced using a fluorescent dye. Direct visual examination and bitewing radiograph were used for comparison. The subjects of this study were 30 children of $3{\sim}9$ years old. Laser fluorescence and dye-enhanced laser fluorescence(mixed wavelength of 488 and 514 nm) were used and viewed through glasses(excluding wavelength<520 nm). For dye-enhanced laser fluorescence a 0.075% sodium fluorescein dye was applied before examination. Proximal caries lesion of each subject was assessed using visual examination, bitewing radiograph, laser fluorescence, and dye-enhanced laser fluorescence. The results in the three detection methods were compared to the assessment of bitewing radiograph. The results from the present study can be summarized as follows: 1. There was highly correlation(r=0.725-0.911) between the bitewing radiograph and all three detection methods(p<0.05) 2. The reproducibility(kappa value) of the visual examination, laser fluorescence and dye-enhanced laser fluorescence comparing with bitewing radiograph of proximal caries was 0.451, 0.683, 0.772, respectively. There was highest correlation between dye-enhanced laser fluorescence and bitewing radiograph for detection of proximal caries. The results from this study indicated that the dye-enhanced laser fluorescence considered to be accurate and reliable method in detecting proximal caries.

  • PDF

The Fabrication an dCharacteristic Analysis with Novel High Efficiency Organic Polymer Green Electroluminescence (새로운 고효울 유기 폴리머 녹색발광소자의 제작 및 특성 분석)

  • Oh, Hwan-Sool
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.12
    • /
    • pp.1-7
    • /
    • 2001
  • Single-layer polymer green electroluminescent devices were fabricated with novel material synthesis by using moleculely-dispersed TTA and NIDI into the polymer PC(B79) emitter layer doped with C6 fluorescent dye which has low operating voltage and high quantum efficiency. A EL cell structure of glass substrate/indium-tin-oxide/PC:TTA:NIDI:C6/Ca/Al was employed and compared with various low work function cathode electrodes Ca and Mg metals. By adjusting the concentration of the fluorescent dye C6, low turn-on voltage of 2.4V was obtained, maximum quantum efficiency of 0.52% at 0.08mole% has been improved by about a factor of ~50 times in comparison with the undoped cell. The PL and EL colors can't be turned by changing the concentration of the C6 dopant. PL emission peaking was obtained at 495nm and EL emission peaking at 520nm with FWHM ~70nm

  • PDF

In Vivo Spinal Distribution of Cy5.5 Fluorescent Dye after Injection via the Lateral Ventricle and Cisterna Magna in Rat Model

  • Lee, Kee-Hang;Nam, Hyun;Won, Jeong-Seob;Hwang, Ji-Yoon;Jang, Hye Won;Lee, Sun-Ho;Joo, Kyeung Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.434-440
    • /
    • 2018
  • Objective : The purpose of this study was to find an optimal delivery route for clinical trials of intrathecal cell therapy for spinal cord injury in preclinical stage. Methods : We compared in vivo distribution of Cy5.5 fluorescent dye in the spinal cord region at various time points utilizing in vivo optical imaging techniques, which was injected into the lateral ventricle (LV) or cisterna magna (CM) of rats. Results : Although CM locates nearer to the spinal cord than the LV, significantly higher signal of Cy5.5 was detected in the thoracic and lumbar spinal cord region at all time points tested when Cy5.5 was injected into the LV. In the LV injection Cy5.5 signal in the thoracic and lumbar spinal cord was observed within 12 hours after injection, which was maintained until 72 hours after injection. In contrast, Cy5.5 signal was concentrated at the injection site in the CM injection at all time points. Conclusion : These data suggested that the LV might be suitable for preclinical injection route of therapeutics targeting the spinal cord to test their treatment efficacy and biosafety for spinal cord diseases in small animal models.

Analysis of the Characteristics of a White OLED using the Newly Synthesized Blue Emitting Material nitro-DPVT by Varying the Doping Concentrations of Fluorescent Dye and the Thickness of the NPB Layer (신규 합성한 청색발광재료 nitro-DPVT를 사용한 백색 유기발광다이오드의 형광색소 도핑농도 및 NPB 층의 두께 변화에 따른 특성 분석)

  • Jeon, Hyeon-Sung;Cho, Jae-Young;Oh, Hwan-Sool;Yoon, Seok-Beom
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.379-385
    • /
    • 2006
  • A stacked white organic light-emitting diode (OLED) having a blue/orange emitting layer was fabricated by synthesizing nitro-DPVT, a new derivative of the blue-emitting material DPVBi on the market. The white-emission of the two-wavelength type was successfully obtained by using both nitro-DPVT for blue~emitting material, orange emission as a host material and Rubrene for orange emission as a guest material. The basic structure of the fabricated white OLED is glass/ITO/NPB$(200{\AA})$/nitro-DPVT$(100{\AA})$/nitro-DPVT:$Rubrene(100{\AA})/BCP(70{\AA})/Alq_3(150{\AA})/Al(600{\AA})$. To evaluate the. characteristics of the devices, firstly, we varied the doping concentrations of fluorescent dye Rubrene from 0.5 % to 0.8 % to 1.3 % to 1.5 % to 3.0 % by weight. A nearly pure white-emission was obtained in CIE coordinates of (0.3259, 0.3395) when the doping concentration of Rubrene was 1.3 % at an applied voltage of 18 V. Secondly, we varied the thickness of the NPB layer from $150{\AA}\;to\;200{\AA}\;to\;250{\AA}\;to\;300{\AA}$ by fixing doping with of Rubrene at 1.3 %. A nearly pure white-emission was also obtained in CIE coordinates of (0.3304, 0.3473) when the NPB layer was $250-{\AA}$ thick at an applied voltage of 16 V. The two devices started to operate at 4 V and to emit light at 4.5 V. The external quantum efficiency was above 0.4 % when almost all of the current was injected.

THE EFFECTS OF SEALING ON THE PLASMA-SPRAYED OXIDE-BASED COATINGS

  • Kim, Hyung-Jun;Sidoine Odoul;Kweon, Young-Gak
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.53-58
    • /
    • 2002
  • Electrical insulation and mechanical properties of the plasma sprayed oxide ceramic coatings were studied before and after the sealing treatment of the ceramic coatings. Plasma sprayed A1$_2$O$_3$-TiO$_2$ coating as the reference coating was sealed using three commercial sealants based on polymer. Penetration depth of the sealants to the ceramic coating was evaluated directly from the optical microscope using a fluorescent dye. It is estimated that the penetration depth of the sealants to the ceramic coating is from 0.2 to 0.5 mm depending on the sealants used. The preliminary test results with a DC puncture tester imply that the dielectric breakdown voltage mechanism of plasma sprayed ceramic coatings has been determined to be a corona mechanism. Dielectric breakdown voltage of the as-sprayed and as-ground samples have shown a linear trend with regard to the thickness showing an average dielectric strength of 20 kV/mm for the thickness scale studied. It is also shown that grinding the coating before sealing and adding fluorescent dye do not agent the penetration depth of sealants. All of the microhardness, two-body abrasive wear resistance, bond strength, and surface roughness of the ceramic coating after the sealing treatment are improved. The extent of improvement is different from the sealants used. However, three-point bending stress of the ceramic coating after the sealing treatment is decreased. This is attributed to the reduced micro-crack toughening effect since the cracks propagate easily through the lamellar of the coating without crack deflection and/or branching after the sealing treatment.

  • PDF

A Fluorescent Sensor Film for Detecting pH of Acidic Solutions (산성 용액의 pH를 감지할 수 있는 형광 센서막)

  • Min, Jae Young;Kim, Hyung Jin
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.2
    • /
    • pp.74-78
    • /
    • 2020
  • A push-pull conjugated dye (DCMP) was covalently immobilized on a silanized glass surface to produce a high sensitivity pH sensor film for operating in the acidic region. A pH-sensitive sensor film was prepared by photo-initiating copolymerization of a modified DCMP (DCMA), 2-hydroxyethyl methacrylate (HEMA) and triethylene glycol dimethacrylate on the silanized glass surface. The absorbance of the sensor film increased with increasing pH between pH 2.0 and 5.0, and the fluorescence intensity of the film also increased about 50 times with increasing pH in the same pH range. The sensor film was reversible and reproducible under acidic conditions. The sensor film showed a relatively short response time between 20-50 seconds and high selectivity for proton in the presence of various metal ions.

Porphyra tenera induces apoptosis of oral cancer cells (구강암 세포주에서 김 추출물에 의한 세포자멸사 유도)

  • Kim, Sang Chan;Lee, Jong Rok;Park, Sook Jahr
    • The Korea Journal of Herbology
    • /
    • v.30 no.2
    • /
    • pp.25-30
    • /
    • 2015
  • Objectives : Laver (Porphyra tenera), a red algae species, is one of the most widely consumed edible seaweed in Korea. Laver contains various substances such as essential amino acid, fiber, minerals and polyphenols that benefit human health. In the present study, we prepared ethanol extracts from commercially processed product of Porphyra tenera, and evaluated the growth inhibitory effect against human oral squamous carcinoma YD-10B cells. Methods : Cell viability was measured by MTT assay. Apoptosis was confirmed by TUNEL assay and flow cytometry with the green fluorescent dye FITC annexin V entering apoptotic cells and the red fluorescent dye PI not entering. The expression of the relevant proteins was detected using Western blot. Results : Ethanol extracts of Porphyra tenera (PTE, $50-200{\mu}g/m{\ell}$) caused a significant decrease of cell viability in a dose dependant manner. The cell death occurred as a result of apoptotic process as determined by TUNEL assay and flow cytometric analysis. In line with this observation, decrease in procaspase proteins and increase in cytosolic cytochrome c were observed in cells treated with PTE. In addition, exposure to PTE decreased the expression levels of Bcl-2, and induced PARP cleavage and AIF translocation from mitochondria to nucleus. Conclusions : In conclusion, PTE exerts anti-cancer effects by inducing apoptosis via caspase activation and AIF nuclear translocation in YD-10B cells. These results provide evidence for the possible therapeutic effect of Porphyra tenera in oral cancer cells.